| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.7 LAccepted-AOC | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹15.1 L+₹11,849 (0.79%)Rejected-Finance | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹15.6 L+₹63,165 (4.22%)Rejected-Finance | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹16.8 L+₹1.8 L (11.9%)Rejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹17.3 L+₹2.3 L (15.6%)Rejected-Finance | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
16 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Srinagar
Garrison Engineer (AF) Air Force Station Srinagar 190 007
REPAIR /REPLACEMENT OF INTERNAL WIRINGS, SOCKETS, SWITCHES, ETC AND ALLIED WORKS AT DOMESTIC AND MES OTM ACCN UNDER GE (AF) SRINAGAR
2024_MES_661757_1
GE (AF)/SGR-04/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE AF Srinagar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹58,000
Yes
2 Sept 2024
24 Jun 2024
18 Jul 2024
24 Jun 2024
16 Jul 2024
9 Jul 2024
Amount
Taking down point wiring with aluminum/copper conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator DB boxes with all fixtures service wire etc, and making good to the disturbed surfaces of walls/ floor etc to match with existing surfaces including white washing/colour washing/ distemper to match with existing wall/floor/ceiling finishes, complete all as specified and directed.
M&L point wiring 1100 volt grade single coreFRLS/ FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed type including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel sunken box thickness not less than 1.8 mm on wall for mounting of piano/flush type switches, switch sockets, fan regulator etc any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly, complete all as specified and directed.
As per Ser item No 2.00 here in above but One light point controlled by one switch.
As per Ser item No 2.00 here in above but one ceiling /exhaust fan point controlled by one switch and regulator.
As per Ser item No 2.00 here in above but one 3 pin 5 Amp socket out point on the same board with other switches.
As per Ser item No 2.00 here in above but one 3 pin 5 Amps socket outlet point on independent board.
As per Ser item No 2.00 here in above but two way point wiring.
As per Ser item No 2.00 here in above but one bell/buzzer point controlled by one bell push.
As per Ser item No 2.00 here in above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 Amps power point.
M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit/casing caping on surface of wall not less than 20mm dia/25mm width with IS 9537 (Part-III) 1983 marked medium grade on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel sunken box thickness not less than 1.8 mm on wall for mounting of piano/flush type switches, switch sockets, fan regulator etc any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
As per Ser item No 10.00 her in above but one lihgt point controlled by one switch.
As per Ser item No 10.00 her in above but one ceiling /exhaust fan point controlled by one switch and regulator.
As per Ser item No 10.00 her in above but one 3 pin 5 Amp socket out point on the same board with other switches.
As per Ser item No 10.00 her in above but one 3 pin 5 Amps socket outlet point on independent board.
As per Ser item No 10.00 her in above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point.
As per Ser item No 10.00 her in above but one bell/buzzer point controlled by one bell push.
S&F in repairs modular one way switch 6 Amp 240 volts suitable for one module, complete all as specified and directed.
S&F in repairs modular two way switch 6 Amp 240 volts suitable for one module, complete all as specified and directed.
S&F in repairs modular one way bell push 6 Amp 240 volts suitable for one module, complete all as specified and directed.
S&F in repairs modular one way switch 16 Amp 240 volts suitable for one module, complete all as specified and directed.
S&F in repairs modular 6 Amp socket suitable for two module 240 volts, complete all as specified and directed.
S&F in repairs modular 16 Amp socket suitable for two module 240 volts, complete all as specified and directed.
S&F in repairs modular step type fan regulator suitable for 120 watt 250 volts, complete all as specified and directed.
S&F in repairs lamp holder/batten holder Polycorbonate type with back plate suitable for batten fitting, complete all as specified and directed.
S&F in repairs ceiling rose with three terminal as per relevant IS, complete all as specified and directed.
Supply only 10 watt LED bulb, complete all as specified and directed.
S&F in repairs LED baton fitting 4' length including drivers having energy consumption, 18/20W (White/warm white), 230 V ,50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
S&F in repairs light fitting 9W/ 10W bulk head luminaries with lamp holders etc complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ, complete all as specified and directed.
S&F in repairs fittings with surface mount LED down lighters 12 W including driver with rated voltage 240 V, 50 Hz, complete all as specified and directed.
S&F in repairs Energy efficient surface mounted 2'X2' grid Ceiling LED fitting 36/40 W rated voltage 240 V, 50Hz combination with profiled and flat diffuse, complete all as specified and directed.
S&F in repairs LED baton fitting 2' length including drivers having energy consumption, 10/11W (White/warm white) ,230 V, 50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
S&F in repairs building security light LED 25 W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc., complete all as specified and directed.
S&F in repairs call bell ding dong type 230 Volts 50 Hz, complete all as specified and directed.
S&F in repairs sheet metal enclosure epoxy powder coated or polysterene insulated material double door type, vertical triple pole & neutral (VTPN) with MCCB 100 amps ICs=ICu,for 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door, complete all as specified and directed.
S&F in repairs epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door), 8 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit, complete all as specified andas directed.
S&F in repairs epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door), 12 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit, complete all as specified and directed.
S&F in repairs MCB triple pole and neutral ISI marked, C series, working on 415 volts 50HZ AC supply for incoming and outgoing controlling system capacity 63 Amps, 10 KA breaking capacity, complete all as specified and directed.
S&F in repairs MCCB three pole ISI marked working on 415 Volts 50Hz supply for incoming and outgoing controlling system of capacity 100 Amps, 16 KA breaking capacity, complete all as specified and directed.
S&F MCB single pole 240 volt 6 to 32 Amps, 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F in repairs MCB single pole and neutral, 40 Amp, 240 volt, 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F in repairs MCB single pole and neutral 63 Amp, 240 volt amps 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F in repairs metal clad plug & socket board SP&N enclosure with 2 pole and earth metal plug and socket complete 20 Amp MCB SP, C curve, complete all as specified and directed.
S&F in repairs metal clad plug & socket board triple pole and neutral enclosure with 3 pin and earth plugs and socket complete with one triple pole MCB 32 Amps, 415 Volts, C type, complete all as specified and directed.
M&L for submain wiring with three run of single core multistranded copper conductor cable, of size 6.0 sqmm PVC insulated, unsheathed conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor thed fire retardant low smoke drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.0 sqmm, PVC insulated, unsheathed fire retardant low smoke earth wire, fixed on wall/ceiling, including taking down old, complete all as specified and directed. Note:- 3 Runs of main cable and one run earth wire with conduit will be measured as one unit for payment purpose.
M&L for submain wiring with two run of single core multistranded copper conductor cable, of size 4.0 sqmm PVC insulated, unshea conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor thed fire retardant low smoke drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 2.50 sqmm, PVC insulated, unsheathed fire retardant low smoke earth wire, fixed on wall/ceiling, including taking down old, complete all as specified and directed. Note:- 2 Runs of main cable and one run earth wire with conduit will be measured as one unit for payment purpose.
Renewal of Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (.c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion, complete all as specified and directed.
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 sqmm, 4.0 core including testing after laid and jointed, complete all as specified and directed.
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured,electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sqmm, 4.0 core including testing after laid and jointed, complete all as specified and directed.
S&F in repairs LED post top light fitting 40W with all fixing accessories fitted on pilar or poles including making suitable PCC 1:2:4, complete all as specified and directed.
S&F in repairs LED bollard lightlight fitting 10W with all fixing accessories fitted on including making suitable pcc foundation/anchoring, PCC 1:2:4, complete all as specified and directed.
S&F in repairs thermoplastic cable junction boxes IP 55/IP65 with metric knockout for cable entry of size 200 x 160 x98 mm fixing on pole with 30 x 5 mm MS clamps, nut bolts, washers, terminal block and glands suitable for 16 Sq mm core cable including 6 amps MCB SPN, complete all as specified and directed.
S&F in repairs adjustable focus light LED type 05 W warm white, complete all as specfied and directed.
S&F in repairs LED driver for flood lights, post top lights and bollard lights etc suitable for 20 to 80 W LED as specified with protection from short circuit, over load, over voltage with input voltage 180-260 volts, 50 Hz , IP65 protection, complete all as specified and directed.
S&F in repairs GI bracket 32/40 mm dia suitable for mounting the building security light, complete all as specified and directed.
Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismentling/taking down items) worth 1,29,064.00 during AOC. Note :- Tenderers shall not quote for this Schedule.
M/S MIR SAJAD ENTERPRISES
M/S GULAM AHMAD ABDUL SAMAD
M/S RATHER CONSTRUCTION CO
M/S NEW FAROOQ TRADERS
M/S LATIF AHMED MIR
M/S NAIK CONSTRUCTION COMPANY
M/S ZAHOOR ENTERPRISES
M/s Bashir Enterprises
M/S Abdul Ahad Rather
M/s Jaipal Associates
M/S M.Y Enterprises
M/S GHULAM MOHAMMAD AND CO.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .