Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹34.1 L+₹5.7 L (20.1%)Rejected-AOC BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹28.4 LSame as L1Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹33.4 L
EMD Value
₹66,780
Closing Date
18 May 2019, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Military Station Bikaner
OUTSOURCING OF SERVICES FOR 1.0 MLD STP AT LONGEWALA COMPLEX AND 1.2 MLD STP AT UMRAO COMPLEX WITH ALLIED WORKS AT MIL STN BIKANER
2019_MES_242609_3
GE (N) BKN/Token-81/18-19
Open Tender
Miscellaneous Works
Item Rate
330 days
under AGE E/M
Class D Category d (v)
8 documents required · 8 mandatory
₹500
GE (N) Bikaner
₹66,780
Yes
20 Mar 2020
4 May 2019
20 May 2019
4 May 2019
18 May 2019
7 May 2019
Amount
Schedule 'A' Section I (Note: The rate quoted shall not be less than minimum wages as notified by Government of India/State Government/Local body whichever is higher . In case the rates quoted are less than the minimum wages as notified by the Government of India/State Government/Local body whichever is higher his tender will be treated as NON BONAFIDE and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonofied bids only) Outsourcing of services for 1.0 MLD STP at longewala complex with 01 FGM in each shift for 3 shifts round the clock and one helper for one shift only will be employed by the contractor (each shift for 08 hours) all as directed by Engineer-in-Charge.
Outsourcing of services for 1.2 MLD STP at Umrao complex(KLP-II) with 01 FGM in each shift for 3 shifts round the clock and one helper for one shift only will be employed by the contractor (each shift for 08 hours) all as directed by Engineer-in-Charge. Notes : For Item No 01 & 02 (i) Daily, weekly, monthly, quarterly, half yearly and annual maint to be carried out and keeping records thereof. (ii) Daily log sheet attendance register for persons employed by the contractor to be maintained. (iii) All types of T&P required for day to day maintenance shall be provided by the contractor. (iv) All types of transportation if reqd for handling materials/eqpts etc shall be provided by the contractor. (v) All types of fire eqpts provided in all the installations shall be maintained and operated properly. (vi) All electrical fitting and fixtures installed at STP installation to be maintained and contractor shall be responsible for any damage. (vii) All types of water tanks shall be maintained. (viii) All installations to be kept neat and clean all the time. (ix) In case of any damage, misuse, mishandling of Govt property, contractor will be held responsible for the same. (x) Chlorination of sewage water are to be carried out from the recognized lab i.e., C.O.D, B.O.D etc and record to be maintained. (xi) Treated water to be tested monthly from recognized lab and record to be maintained. (xii) Medical needs to be provided by the contractor to the employees as and when required. (xiii) First Aid Box with basic medicines to be kept in installation by the contractor. (xiv) Misuse of electricity and water to be penalised and effective recovery will be made by the department. (xv) Outsourcing of services shall start immediately after acceptance of work. (xvi) All garden, lawns, trees etc being planted in all the installations shall be maintained regularly and to be developed further as directed. (xvii) FGM should be ITI qualified or 02 years experience in the particular field. (xviii) Fuel for running of DG Sets of both STP's shall be supplied by the department and contractor shall responsible to collect the fuel from the department by his own arrangement. (xix) Entire area inside and outside of STPs shall be cleaned properly by the contractor and cost shall be deemed included in the quoted rate. (xx) All the FGMs & Helper shall be in proper dress code and shoes as approved by the GE.
Schedule 'A' Section II M & L for taking up incl dismantling, reassembling, transporting and lowering of submersible pump of capacity 13 Mtr head and 42 Mtr Cubic per hours discharge single stage all as specified and directed by Engineer-in-Charge. Make of pump: CALAMA/SABAR/KSB/BED FORD GARVIN/ KIRLOSKAR. Note :- Crane for taking up & lowering of submersible pump set while repairing/rewinding will be arranged by the contractor and the rent for the same is included in the item rate.
Supply & fixing in replacement of the following unserviceable spare parts of submersible pump as per existing make and size against item No 3 above :- (a) S/S Impeller.
(b) S/S Pump shaft (single stage)
(c) Hook bolt (Upper & lower)
(d) S/S neck ring
(e) Key for pump shaft (Each stage)
(f) Distance sleeve
(g) Suction chamber
Dismantling, transporting and reassembling of submersible motor after rewinding & replacement of worn out parts mentioned below incl rewinding of submersible motor 7.5 HP of 03 Phase, 415 volts with PVC insulated solid copper conductor (wire) superior quality of approved make , size & number of wire as per existing complete.
Supply & fix in replacement of the following unserviceable spare parts of submersible motor as per existing make and size against item No 3 above :- (a) GM Bearing Bush
(b) Rotor sleeve
(c) Water seal (KSB only)
(d) Cable seal
Dismantling of existing defective induction motor of 7.5 HP capacity, 03 phase, 415 volts 50 HZ and make from the foundation, disconnecting the electric connecting coupling pulley, and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor ( winding wire)as existing size and gauge complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge.
Dismantling opening and reassembling after repair /replacement of U/S under mentioned parts of centrifugal pump of capacity 7.5 HP. Job includes disconnection from base foundation frame disconnecting electrically, reconnection, re-fixing in position transportation to work shop & back make of pump :- Kirlosker/Crompton Greaves.
Supply & fix in replacement of the following unserviceable spare parts of centrifugal pump as per existing make and size against item No 8 above :- (a) Gland Bush
(b) Gland Cap CI with nut bolt
(c) Ball bearing for 7.5 HP. Make - SKF. NBC.
(d) Shaft sleeve Bronze
(e) Shaft sleeve nut bronze
(f) Set of gasket
(g) Bearing housing DE
(h) Bearing housing NDE
(j) Flexible Tyres cupling
Painting of existing pipe lines at STP with decided colour of paint including arrow mark in the direction of flow all as directed by Engineer-in-Charge.
Cleaning of sewage water tank by de-sludging,scraping the bottom wall with the help of scrapper/wire iron brush removing all scales, craked earth, dirt, mud/slit algi, fungus and other foreign deposited materials and dewatering the left over water and taking them out complete and painting of one coat by liquid bleaching powder complete all as specified and directed Engineer-in-Charge. (Note:- Periodicity of cleaining 6 months)
Cleaning of sewage water well carefully by removing wire mess and lifting the deposited material over the well and taking them out away from well on weekly basis all as specified and directed Engineer-in-Charge.
Cleaning of filter media chambers (04 Nos) by removing deposited material inside the chamber including lifting the material from the chamber and getting out from the chamber without any damage to the chamber on weekly basis including cleaning of filter media all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of NRV CI flanged ends ISI marked size 100mm bore with rubber or fibre board gasket including necessary nuts, bolts and washer complete all as specified and directed . Make : LEADER/ KIRLOSKAR/BIR
Taking out/dismantling of unserviceable compressor cap 30 HP including replacement of wornout components such as bearing as per existing size, compressor oil, rubber seal, repair to pump including reassembling installation, connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
(a) Supply and fixing in replacement. Bearing No. 6205 of Make :SKF/NBC
(b) Supply and fixing in replacement. Bearing No 22308 of make : SKF/NBC
(c ) Supply and fixing in replacement. Rubber Seal for 30 HP compressor
(d) Supply and fixing in replacement fen belt for air blower induction motor suitable for 30 HP comperser motor as per sample all as specified and directed by Engineer-in-Charge
Supply, hoisting and fixing of Rotational moulded polyethylene water storage tanks of capacity 200 Ltrs complete all as specified.
Supply and fixing in replacement of float valves of size 20 mm brass complete all as specified and directed by Engineer-in-Charge.
S&F ih replacement PVC Insulated sheathed 3 core sumersable flate cable for sumserable pumps copper conductor cable (stranded) 1100 Volts grade of size 10 Sqmm Make : havells/Plaza/Finolex
Supply and fixing in replacement of butter fly valve of size 100 mm bore. Make : AUDCO/India/KSB/ Advance.
Supply and fixing in replacement of butter fly valve of size 150 mm bore. Make : AUDCO/India/KSB/ Advance.
Supply and fixing in replacement of butter fly valve of size 80 mm bore. Make : AUDCO/India/KSB/ Advance.
Supply and fixing in replacement of butter fly valve of size 50 mm bore. Make : AUDCO/India/KSB/ Advance.
Supply and fixing in replacement cast iron double end flanged end drilled sluice valve type PN-1.0 ISI marked with CI hand wheel and stainless sprindle including jointing material i.e. nut, bolts,washers,rubbers, gasket all as specified and directed by Engineer -in-charge for 100 mm bore
Supply and fixing in replacement cast iron double end flanged end drilled sluice valve type PN-1.0 ISI marked with CI hand wheel and stainless sprindle including jointing material i.e. nut, bolts,washers,rubbers, gasket all as specified and directed by Engineer -in-charge for 150 mm bore
M & L in replacement MS pipe medium grade of size 200mm bore in tank of STP's complete all as specified and directed by Eng-in-charge.
M & L in replacement MS pipe medium grade of size 80mm bore in tank of STP's complete all as specified and directed by Eng-in-charge.
S& F in replacement fully automatic star delta starter ML-2 or equvalant sutbale for 7.5 HP to 10 HP Motor pump set connection by using Lugs/Thimbles make L&T, Siemans and C&S
Supply & fix in replacement MCCB 100 Amp capacity 4 pole breaking capacity 25 KA , thermal magnetic Fix type 415 volts ,AC ,50Hz including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge. Make: -C&S cat No CS263 L&T/Havells/Crompton greaves
Supply & fix in replacement MCCB 200 Amp capacity 4 pole breaking capacity 25 KA at 415 volts including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge. Make: - L&T/Havells/Crompton greaves
Supply & fix in replacement MCCB 63 Amp capacity 4 pole breaking capacity 16 KA , thermal magnetic Fix type 415 volts ,AC ,50Hz including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge. Make: -C&S cat No CS263 L&T/Havells/Crompton greaves
S&F in replacement MCB single pole, 240 volts of rating 6-32 Amps, breaking capacity of 10 KA of C-series, complete all as specified and as directed by Engineer-in-Charge Make :- Schneider/ HPL/Legrand/ GE/ Seimens/L&T/Indo sian/C&S/Havells/BCH/ABB
S&F in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA of C-series, complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH
S&F in replacement MCB suitable for 32 Amps, 415 Volt AC supply triple pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KAof C-series complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH
Excavation in trenches in soft/loose not exc. 1.5m wide and not exc. 1.5m in depth and getting out complete all as specified.
Returning filling including spreading, leveling watering and well ramming in soft/loose soil in layers not exc. 25cm thick complete all as specified.
Removing surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed
M&L in replacement air pressure gauge round type 0-150 Kg/cm2 make : Guru/ equivenlant
Taking out Bio careers media from STP tanks and replaced unservicable/unuseable in to new Bio careers media ( Material : Organic polymer high density polyethylene, mix into nano sized in organic in gradients(cokes powder zeolite etc.)) for proper airation for sewage water specification as under :- (a) Product : Thermak/equivalent (b) Colour : Black (c) Shape : conical furstum / Tube chip shape (d) Avg. Dia : 10mm (e) Length : 17 mm (f) Thickness : 0.3mm (g) Density : 0.97 to 0.98 Gm/Cm² (h) Surface area : 700-800 Sqm/cum (j) detention time : 5 to 12 hrs Note :- Dissolved oxygen concentration in the reacter to be maintained above 4Mg/ltr
Supply only liquid chlorine (Sodium Hypochlorite at 12% to 16% ) all as directed by Engineer-in-Charge. Note :- (i) Sealed packed liquid chlorine container shall be supplied by the contractor on requirement basis at STP. (ii) Transportation incl labour charge will deemed in the item. (iii) The contractor ensure that liquid chlorine shall be kept for one month in advance at STP.
M&L in replacement of GI Pipe medium grade in trenches complete with fittings all as specified and directed by Engr-in-charge. Make : Jindal/TATA/Surya. (a) 150mm bore
(b) 100mm bore
(c) 80mm bore
39 Supply and fixing in replacement following gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipe complete all as specified (a) size 80mm
(b) size 50mm
(c) size 25mm
(d) size 20 mm
Dismantling joints of flanged pipes in position including removing old rubber or fiber board from gaskets , nuts, bolts etc and S&F detachable joint complete with rubber ring and necessary nut,bolts and washers suitable for CI/GI pipe line complete all as specified and directed by Engr-in-charge (a) 150mm bore
(b) 100mm bore
Cutting of existing CI/GI line of size 100mm dia bore in position for insertion of new CI fittings complete all as specified and directed by Engr-in-charge
Cutting of existing CI/GI line of size150mm dia bore in position for insertion of new CI fittings complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of liquid chlorine pump set of capacity 1.0 HP single phase including all necessary connection, testing complete all as specified and directed by Engineer-in-Charge. Make: Kirlosker/Milton Roy India (P) Ltd/equivalent
Supply and fixing in replacement of the following spare parts of panels (a)contactor MNX 18 - 25 Amp (Make : L&T/C&F/Lergrand)
(b) Relay MN-2 as per sample
(e) Single phase preventor (Make : Minilec/L&T/Siemens)
(f) Front mounting on panel electronic Timer ( delay 0.1-30 Sec) (Make : Minilec/L&T/Siemens)
(g) slector Switch
(h) Push button ON/Off
Taking out carefully, after disconnecting electrical connections, complete assembly of non clog dry motor submersible pump set of Umrao Map STP of capacity 20.8 KLH , 3 phase,of make Kirloskar from sewage tank (about 10m deep); transporting the complete assembly to work shop, opening unserviceable parts, winding etc. and carrying out repairs/replacement mentioned in the items here-in-below including replacement of oil, Reconnecting all the parts and transporting back to the site of work, reconnecting with electrical connections, installing testing & re-commissioning of the complete assembly. Note : 1. Quoted rates are inclusive of minor spares like bolts, nuts, washers etc. 2. Major spares & Oil will be measured and paid separately under respective items of Sch.
(a) Rewinding the complete motor with super enamelled copper winding wire including varnishing for `F' class insulation, baking etc as directed .
(b) Supply only in replacement, the defective upper mechanical seal of make Kirloska Pumps.
(c) Supply only in replacement, the defective lower mechanical seal of make Kirloskar Pumps.
(d) Supply only in replacement, a set of defective upper and lower oil seals of make Kirloskar Pumps.
(e) Replacing the defective angular ball bearing of make SKF / TATA (3308 A/C-3) or equivalent as directed by Engr-in-Charge
Supply and fix in replacement gland packing graphite and grease coated suitable for pump sets of size 4mm / 6mm
S&F in replacement of battery lugs of brass heavy duty bolt/eye type
Dismantling, opening complete Duel media filter installed at sewage treatment plant including taking out carefully filter media completely of different sizes , cleaning the filter walls, pipes and other accessories with wire brush, painting with one coat of red oxide paint and two coats of Bituminous black water proof paint inside duel media filter and with Synthetic Enamel Paint on external surface of existing colour shade, replace the media as per existing shape /size or as directed by Engr-in-Charge , assemble complete unit and testing, commissioning complete all as directed. (Note : Filter sand media ie pebbles and filter sand will be measured and paid separately under relevent items)
Supply only multi grade sand / pebbles for Duel media filter comprising of sizes as under :- (a) Anthracite upto (480mm) - 02 Qtl (b) Filtering sand 16/32 (800mm) - 3.18 Cum (c) Fine Silex (160mm) - 0.65 Cum (d) Coarse Silex (160 mm) - 0.65 Cum (e) 6-2 Crushed Gravels (160mm) - 0.65 Cum (f) 20-12 Pebbles (160mm) - 0.65Cum (g) 40-25 pebbles (160mm) - 0.65 Cum
Dismantling, opening complete Activated Carbon filter installed at sewage treatment plant including taking out carefully filter media completely of different sizes , cleaning the filter walls, pipes and other accessories with wire brush, painting with one coat of red oxide paint and two coats of Bituminous black water proof paint inside duel media filter and with Synthetic Enamel Paint on external surface of existing colour shade, replace the media as per existing shape /size or as directed by Engr-in-Charge , assemble complete unit and testing, commissioning complete all as directed. (Note: filter media i.e. pebbles and filter sand will b emeasured and paid seperately under relevent items)
Supply only multi grade sand / pebbles for Duel media filter comprising of sizes as under :- (a) Activated cobon (900mm) - 02 tones (b) Fine Silex (100mm) - 1 tones (c) Coarse Silex (100mm) - 13 tones (d) 6-2 Crushed Gravels (100mm) - 01 tones (e) 20-12 Pebbles (160mm) - 01 tones (f) 40-25 pebbles (160mm) - 01 tones
Labour only for taking out as directed and filling new sand, graavels, and otthrer filter media from dry sludge bed of sewage treatment plants complete all as specified and directed. (Note- Complete set of 6 beds)
Pumping out and removing of sewage water / mud from the aeration tank, and maturation tank and wet well using suitable dewatering pump / non clog sewage pump or manually and disposed off out side the MD land by means of closed portable tanks etc complete all as directed by the Engineer-in-charge
BIDAWAT ENTERPRISES
M/s Chopra Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .