Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance MADINA CHOWK MAISUMA GOW KADAL SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Finance |
Tender Value
₹7.2 L
EMD Value
₹14,300
Closing Date
18 Nov 2023, 4:00 pmClosed
Executive Engineer, ED-3rd srinagar
Office of Executive Engineer, ED-3rd srinagar
HT-LT improvement works at various sites falling under the jurisdiction of Electric Division-3rd under Capex Budget 2023-24 (Partial Turnkey Basis)
2023_PDD_233499_1
ED-III/17 of 2023-24, Dated - 16/10/2023
Open Tender
Electrical Works
Turn-key
20 days
Office of Executive Engineer, ED-3rd srinagar
Refer SBD, Specifications, Drawing
7 documents required · 7 mandatory
₹500
Executive Engineer, ED-3rd srinagar
₹14,300
23 Nov 2023
16 Oct 2023
20 Nov 2023
16 Oct 2023
18 Nov 2023
20 Oct 2023
20 Oct 2023 - 18 Nov 2023
Amount
HT-LT improvement works at various sites falling under the jurisdiction of Electric Division-3rd under Capex Budget 2023-24 (Partial Turnkey Basis)
Installation, testing and commissioning (Including Transportation, loading and unloading from Divisional store to various sites) of S.T. poles 9.0 Meter long swaged Type conforming to ST 410 SP-33, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded (Material to be provided departmentally) 1. ESD Watalkadal- 5 no. 2. ESD Nawakadal-0 3. ESD Pather Masjid- 5 No. 4. ESD M.R Gunj- 3 no. 5. ESD Zainakote- 0
Installation, testing and commissioning (Including Transportation, loading and unloading from Divisional store to various sites) of S.T. poles 8.0 Meter long swaged Type conforming to ST 410 SP-15, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 15). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded. (Material to be provided departmentally) 1. ESD Watalkadal- 1 no. 2. ESD Nawakadal - 0 3. ESD Pather Masjid- 3 no. 4. ESD M.R Gunj- 3 no. 5. ESD Zainakote- 5 no.
Installation, testing and commissioning (Including Transportation, loading and unloading from Divisional store to various sites) of 8 mtr. Long Pole- PCC WL-250Kg (Material to be provided departmentally). 1. ESD Watalkadal- 0 2. ESD Nawakadal-100 no. 3. ESD Pather Masjid-0 4. ESD M.R Gunj-0 5. ESD Zainakote-0
Laying, installation, testing and commissioning (Including Transportation, loading and unloading from Divisional store to various sites) of 30 mm² ACSR Conductor (Material to be provided departmentally). 1. ESD Watalkadal-0 2. ESD Nawakadal- 0 3. ESD Pather Masjid- 0 4. ESD M.R Gunj- 0 5. ESD Zainakote-600 Mtr
Laying, installation, testing and commissioning (Including Transportation, loading and unloading from Divisional store to various sites) of 50 mm² ACSR Conductor (Material to be provided departmentally). 1. ESD Watalkadal- 100 Mtr 2. ESD Nawakadal- 600 Mtr 3. ESD Pather Masjid- 500 Mtr 4. ESD M.R Gunj- 300 Mtr 5. ESD Zainakote-600 Mtr
Laying, installation, testing and commissioning (Including Transportation, loading and unloading from Divisional store to various sites) of100 mm² ACSR Conductor (Material to be provided departmentally). 1. ESD Watalkadal- 100 Mtr 2. ESD Nawakadal- 0 3. ESD Pather Masjid-0 4. ESD M.R Gunj- 600 Mtr 5. ESD Zainakote- 1000 Mtr
Laying, installation, testing and commissioning (Including Transportation, loading and unloading from Divisional store to the site) of 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 mm²) XLPE (1.1kV, 3+1 C, Al) including lugs/clamps, if required. (Material to be provided departmentally). 1. ESD Watalkadal- 120 Mtr 2. ESD Nawakadal- 0 3. ESD Pather Masjid-0 4. ESD M.R Gunj- 0 5. ESD Zainakote- 0
Supply and fixing of GI Channel/Angle/Flat of sizes including clamps /Collars (As per KPDCL drawings) 1. ESD Watalkadal- 115 Kg 2. ESD Nawakadal- 0 3. ESD Pather Masjid-115 Kg 4. ESD M.R Gunj- 69 Kg 5. ESD Zainakote- 60 Kg
Suppy, laying, installation, testing & commissioning of 120 mm² AB (HT) Cable (3x120 + 1x95 mm²) XLPE(11 kV, 3C + Earth) 1. ESD Watalkadal- 15 Mtr 2. ESD Nawakadal- 0 3. ESD Pather Masjid-0 4. ESD M.R Gunj- 0 5. ESD Zainakote- 0
Suppy, laying, installation, testing & commissioning of Heat Shrinkable Outdoor Cable Termination Kit 1. ESD Watalkadal- 2 set 2. ESD Nawakadal- 0 3. ESD Pather Masjid-0 4. ESD M.R Gunj- 0 5. ESD Zainakote-0
Suppy, laying, installation, testing & commissioning of Suspension/Tension Clamp with eye hook 1. ESD Watalkadal- 5 set 2. ESD Nawakadal- 0 3. ESD Pather Masjid-0 4. ESD M.R Gunj- 0 5. ESD Zainakote- 0
Supply, installation, testing and commissioning of 11kV Polymeric composite Pin Insulator with pins 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 1. ESD Watalkadal- 15 no. 2. ESD Nawakadal- 0 3. ESD Pather Masjid-15 no. 4. ESD M.R Gunj- 9 no. 5. ESD Zainakote- 12 no.
Supply and fixing of Galvanized Nuts and Bolts of sizes as per KPDCL drawings 1. ESD Watalkadal- 6 Kg 2. ESD Nawakadal- 100 Kg 3. ESD Pather Masjid-8 Kg 4. ESD M.R Gunj- 6 Kg 5. ESD Zainakote- 5 Kg
Providing and fixing of Pole Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip 25x3 mm 1. ESD Watalkadal- 6 No. 2. ESD Nawakadal- 0 3. ESD Pather Masjid-8 No. 4. ESD M.R Gunj- 6 No. 5. ESD Zainakote- 5 No.
Providing and painting of poles with single coat of red oxide an two coats of Aluminum Paint 1. ESD Watalkadal- 6 No. 2. ESD Nawakadal- 0 3. ESD Pather Masjid-8 No. 4. ESD M.R Gunj- 6 No. 5. ESD Zainakote- 5 No.
Supply and Fixing of 16 KN Polymer Shackle Insulators including GI U-Clamps for Shackle Insulators 1. ESD Watalkadal- 4 set 2. ESD Nawakadal- 400 set 3. ESD Pather Masjid-12 set 4. ESD M.R Gunj- 12 set 5. ESD Zainakote- 20 set
Supply and fixing of Insulating Piercing Connectors 1. ESD Watalkadal- 12 Mtr 2. ESD Nawakadal- 0 3. ESD Pather Masjid-0 4. ESD M.R Gunj- 0 5. ESD Zainakote- 0
Supply, Installation, testing and commissioning of Main Service Distribution Box Along with back clamp & mounting clamp with nuts and bolts as per KPDCL drawing. 1. ESD Watalkadal- 3 No. 2. ESD Nawakadal- 0 3. ESD Pather Masjid-0 4. ESD M.R Gunj- 0 5. ESD Zainakote- 0
Supply, Installation, laying, testing and commissioning of Stone Pad (300 mm x 300 mm x 75 mm) 1. ESD Watalkadal- 0 2. ESD Nawakadal- 100 No. 3. ESD Pather Masjid-0 4. ESD M.R Gunj- 0 5. ESD Zainakote- 0
Supply, installation, testing and commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type as per KPDCL drawing. 1. ESD Watalkadal- 0 2. ESD Nawakadal- 0 3. ESD Pather Masjid-0 4. ESD M.R Gunj- 0 5. ESD Zainakote- 2 set
Supply and fixing of Danger Plates with Clamps 1. ESD Watalkadal- 5 No. 2. ESD Nawakadal- 0 3. ESD Pather Masjid-5 No. 4. ESD M.R Gunj- 3 No. 5. ESD Zainakote- 0
Supply and fixing of Anti-Climbing Device with Clamps 1. ESD Watalkadal- 5 No. 2. ESD Nawakadal- 0 3. ESD Pather Masjid-5 No. 4. ESD M.R Gunj- 3 No. 5. ESD Zainakote- 0
Providing of material and laying of Cement bottoming of poles (1:2:4 Mix as per REC Standards 0.45 M3 per Pole) 1. ESD Watalkadal- 1 No. 2. ESD Nawakadal- 0 3. ESD Pather Masjid-3 No. 4. ESD M.R Gunj- 3 No. 5. ESD Zainakote- 5 No.
Providing of material and laying of Cement bottoming of poles (1:2:4 Mix as per REC Standards 0.5 M3 per Pole) 1. ESD Watalkadal- 5 No. 2. ESD Nawakadal- 0 3. ESD Pather Masjid-5 No. 4. ESD M.R Gunj- 3 No. 5. ESD Zainakote- 0 No.
M/S TOP TECH ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .