Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 64 ANURADHA APARTMENT LBS ROAD NAVI PETH PUNE 411 030 | PUNE | PUNE | MAHARASHTRA | 411030 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
20 Mar 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CGM PPD
JNPA Administration Building,sheva
Quotation for E Quotation For Proposed Development and Modernization, Face Uplift, Internal Re arrangement, Waterproofing, Plumbing etc. Work for Existing VIP Guest House I at JNPA.
2024_JNPT_800966_1
PPD/DGM/Quotation/Guest House-I/2024/555
Open Tender
Civil Works
Item Rate
Jawaharlal Nehru Port Authority, sheva
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
21 Mar 2024
15 Mar 2024
21 Mar 2024
15 Mar 2024
20 Mar 2024
15 Mar 2024
Amount
Extra Item
Civil and Interior (Extra Item)
Providinng and fixing Rubber Flooring 25 mm thick for Gym area as per Design & Drawing or as per Direction by Engineer Incharge.
Providinng and Laying of aluminium ladder 9m Height for mentainance purpose as per site Requirment or as per Direction by Engineer In Charge.
Supply & Installation of DORMA or Equivalent SG System100 Door 1500 - 2100 mm on provided door Frames & Glass Shutter of size 100mm x 30/45mm & Style 70mm x 45mm for door of size 1500 x 2100. It includes supply of 10mm Thick Toughened glass for Door. Hardware as below. FLUSH HINGE 127x78x3mm, SS304, SATIN FIN, Dorma Narrow Style Lever handle and Lock, TS70 OPEN Door Closer with Slide channel arm and hold open unit, Half Dome Door Stopper. as per Desing & Drawing or as per Direction by Engineer In Charge.
Application of DR FIXIT HIGH PERFORMANCE FASTFLEX TWO COATS AS PER TECHNICAL SPECIFICATIONS.After Complition Chemical Coating, then Application of Protection Screed with SBR
Providing & Laying of Pathway kurbstone 200mm width & 300 mm Height as per Detail Drawing or as per Direction by Engineer Incharge
Providing and applying a suitable bond coat of specified and suitable Polymer Compound wherever necessary and as instructed by the Consultant using appropriate combination of "POLYALK-EP" of M/s.Sunanda Chemicals or "VERSABOND'" of M/s. Zupa Chemicals or other approved equivalent, all as per detailed specifications of manufacturers, including Providing and applying Polymer Mortar of required thickness (not exceeding 25mm for one layer) for spot repair of isolated or small spalled areas of R.C.C. Members using approved clean quartz sand and Polymer compounds including necessary bond coats between layers for multilayer application as per detailed specifications of manufacturers and instructions of the Consultant.
Making of Core Cutting 150 mm dia & 12 inch Depth with all Lead & Lift and Removing the Debris or as per Direction by Enginer In Charge.
Making of Core Cutting 100 mm dia & 12 inch Depth with all Lead & Lift and Removing the Debris or as per Direction by Enginer In Charge
Making of Core Cutting 75 mm dia & 12 inch Depth with all Lead & Lift and Removing the Debris or as per Direction by Enginer In Charge
Making of Core Cutting 50 mm dia & 12 inch Depth with all Lead & Lift and Removing the Debris or as per Direction by Enginer In Charge
Supply & Installation of Modular Gypsum Trap door 600 mm x 600 mm as per Detail Design & Drawing or as per Diretion by Engineer In Charge.
Supply & Installation of Modular Gypsum Trap door 450 mm x 450 mm as per Detail Design & Drawing or as per Diretion by Engineer In Charge.
Providing and Fixing of GI Lay in Perforated metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.
Supply & Installation of Antistatic flooring 4 mm thick as per Desing & Drawing or as per Direction by Engineer In Charge.
Providing fixing laminate finishing Study Table Size 1200 mm x 600 mm as per Detail Design & Drawing or as per Ditrection by Engineer In Charge.
Providing fixing Veneer finishing Study Table Size 1200 mm x 600 mm as per Detail Design & Drawing or as per Ditrection by Engineer In Charge.
Providing & Fixing of Aluminium Cornar Guard Size (15 mm x 15 mm ) for protect the Corner as per Detail Design & Drawing or as per Direction by Engineer In Charge.
Plumbing System (Extra Item)
MANHOLE CHAMBERS
Constructing brick masonry man hole chambers for electrical & LV Services with bricks of class designation 75 in cement mortar 1:5 (1 cement : 5 coarse sand) with RCC top slab of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), 200 mm thick foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside and outside plastering 12mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement inside and rough plaster on outside and making channel in cement concrete 1:2:4 mix, (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete.(1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) neatly finished complete M.S s, complete as per standard design and approved drawings, including the cost of excavation, back filling, disposal of surplus earth foot rests and other associated civil works with S.F.R.C cover and frame (heavy duty, HD- 20 grade designation) conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement
Providing and Fixing of Brass Y Strainer 50mm Dia Zoloto Make as per Drawing or as per Direction by Engineer In Charge.
Supply Installation Testing & Commissioning of heat Pump 18 Kw with accessories. For Solare water heating System, with one Year Warranty as per site Requirment or as per Direction by Engineer In Charge.
Electrical Work (Extra Item)
Supply and laying of 1C X 300 Sqmm. YY Cable Make- polycab or Equivalent or as per Direction by Engineer In Charge.
Supply and installation of End Termination 1C X 300 Sqmm. YY Cable or as per Direction by Engineer In Charge.
Supply and Laying of 1C X 16 Sqmm. YY Cable Make- polycab or Equivalent or as per Direction by Engineer In Charge.
Supply and installation of End Termination 1C X 16 Sqmm. YY Cable or as per Direction by Engineer In Charge.
Supply, Installation, Testing & commissioning of 1-Ph Power Sockets for Kitchen with 32A, 5Pin, Socket & Plug (3P+N+E) - 1no; 32A, FP MCB+ELCB (100mA) - 1no etc complete mounted in IP65 Box. Plug & Socket must be of IP65 Type. (Make- Legrand or equivalent ) or as per Direction by Engineer In Charge.
Supply & Installation of Rubber Mats of 1000mm width & thickness of 10mm. 1.1 KV Voltage grade.Make - ISI Mark.
Electrical Inspector Charges to approve entire Electrical Installation of Floor for relevnt project execution area. The job involves submission of application, test report & other relevant documents as may be required to EI, follow up with EI, collection of FQ, making necessary application payment to EI (DD for the same shall be MSven by client), coordination with EI project team & getting the relevant work done from EI at site for obtaining power supply. This being a time bound job, the EI approval & meter connection work should be carried out within the time frame mentioned in tender. (This is to be noted that this work include liasoning with EB & Electrical Inspector charges to approve entire Electrical installation Work). The job involves submission of drawings, test report, arranMSng visit of electrical Inspector at site, Approval of Electrical Inspector on drawing Layout.
Supply, Installation, Testing & commissioning of guest room key card Make - legrand, Anchor or Equivalent or as per Direction by Engineer In Charge.
1010 KVA DG Shifting work Reinstalling, testing and commissioning of Diesel Generating set of capacity 1010 KVA at 1500 RPM, 0.8 lagging power factor at 415 Volts suitable for 50 Hz, 3 phase system (Make- Kirloskar ) or as per Direction by Engineer In Charge.
1010 KVA DG Shifting work Loding,Unloading & Transportation of 1010 KVA DG or as per Direction by Engineer In Charge.
CHANGEOVER PANEL Deisgning, Supplying, Transporting to project site, Installing the Main Panel on a suitable MS fabricated stand 300mm above the floor level in approved manner, fixing of all the switchgear, controlgear and instrumentation using all the accessoires, proper termination, wiring with suitable size lugs, testing and successful commisioning. The components and the protection type are as below as per SLD- 1. IP43, 16SWG - Overall, 14SWG - Gland plates, Top entry 2. Powder coated - RAL7310 3. Base frame - 100mm C channel 4. Incomer - ATS - __A 5. Outgoing - feeders 6. SPD for the Main Incomer and AC Feeder 7. Please refer the SLD
Supply, Installation, Testing & commissioning of Meter Panel Designing, Supplying, Transporting to project site, Installing the Meter Panel on the floor level in approved manner, fixing of all the switchgear, controlgear and instrumentation using all the accessoires, proper termination, wiring with suitable size lugs, testing and successful commisioning. The components and the protection type are as below as per SLD- 1. IP43, 16SWG - Overall, 14SWG - Gland plates, Top entry 2. Powder coated - RAL7310 3. Base frame - 100mm C channel 4. Incomer -400A 36KA MCCB 5. Outgoing - VIP guest house & poilet guest house feeders 6. SPD for the Main Incomer and AC Feeder 7. Please refer the SLD 8. Cu Busbar
Labling of Switch Board, Cable, DB & Panel or as per Direction by Engineer In Charge.
Supply, Installation of Aviation LED lamps or as per Direction by Engineer In Charge. Make - ISI Mark.
Supply, Installation, Testing & commissioning of Occupancy / ultrasonic Sensor Make - Wipro, Havells 0r Equivalent or as per Direction by Engineer In Charge.
Supply and Installation of Floor mounted Decorative light Make - Wipro, Havells 0r Equivalent or as per Direction by Engineer In Charge.
Supply and Installation of Suspended Decorative light Make - Wipro, Havells 0r Equivalent or as per Direction by Engineer In Charge.
Supply and Installation of Wall light 2x12W Make - Wipro, Havells 0r Equivalent or as per Direction by Engineer In Charge.
Supply & Installation of wall Light 2 x 18 Watt Make - Wipro, Havells 0r Equivalent or as per Direction by Engineer In Charge.
Supply & Installation of Recess Mounted led COB Downlight 24 Watt Make - Wipro, Havells 0r Equivalent or as per Direction by Engineer In Charge.
Providing and applying 350mmOD 5mm thick GI Piping with Rockwool insilation with GI Sheet coting. For Stag. or as per Direction by Engineer In Charge.
Providing & fixing of RGB Light 10 watt. Make - Wipro, Havells 0r Equivalent or as per Direction by Engineer In Charge.
HVAC Work (Extra Item)
Supply of Outdoor unit (18HP & 20 HP) Zone -2 (18*4=72 HP) + (20*3=60 Hp)
Supply of Round Flow Type Indoor Cassette Units 2.56 TR Make - Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supply of Round Flow Type Indoor Cassette Units 1.28 TR Make Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supply of One way Type Cassette Unit 1.28 TR Make Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supplu of High Static Pressure Ceiling Mounted Duct Type Units 1.28 TR Make Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supply of High Static Pressure Ceiling Mounted Duct Type Units 3.98 TR Make Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supply of High Static Pressure Ceiling Mounted Duct Type Units 1.59 TR Make Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supply of High Static Pressure Ceiling Mounted Duct Type Units 2.56 TR Make Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supply of High Static Pressure Ceiling Mounted Duct Type Units 3.18 TR Make Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supply of Customized Ceiling Suspended Duct Type unit 2950 CFM/ 8.43 TR Make Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supply of Hi-Wall Unit 2.02 TR Make Daikin/Toshiba/Hitachi or Equivalent. Or as per Direction By Engineer In Charge.
Supplu Inatallation Testing & Commissioning of Cabinet type Exhaust air fan 1950 cfm for ground floor Kitchen as per Design & Drawing or as per Direction by Engineer In cHarge.
Supply Installation testing & Commissioning of Cabinet type fresh air fan 910 cfm for Ground floor Kitchen (additional 2 filters) as per Design & Drawing or as per Dirction by Engineer In Charge.
Supply Installation testing & Commissioning of Cabinet type fresh air fan 900 cfm for Ground floor Kitchen (additional 2 filters) as per Design & Drawing or as per Dirction by Engineer In Charge.
Supply Installation testing & Commissioning of Inline type Exhaust air fan 60 cfm for ground floor Kitchen, as per Design & Drawing or as per Dirction by Engineer In Charge.
Supply Installation testing & Commissioning of cabinet type Exhaust air fan 650 cfm / 20mm static as per Design & Drawing or as per Dirction by Engineer In Charge.
Supply Installation testing & Commissioning of Propeller Type Exhaust air fan 100 cfm for Toilets as per Design & Drawing or as per Dirction by Engineer In Charge.
Supply Installation testing & Commissioning of Inline type Exhaust air fan 200 cfm for Toilet as per Design & Drawing or as per Dirction by Engineer In Charge
Supply Installation testing & Commissioning of Inline type Exhaust air fan 150 cfm for ground floor café handwash area as per Design & Drawing or as per Dirction by Engineer In Charge
Supply Installation testing & Commissioning of Inline type Exhaust air fan 150 cfm for first floor Gym Area as per Design & Drawing or as per Dirction by Engineer In Charge
Supply Installation testing & Commissioning of Smoke pill type type Exhaust air fan 200 cfm for Battery area as per Design & Drawing or as per Dirction by Engineer In Charge
Supply Installation testing & Commissioning of Inline type fresh air fan 200 cfm for ground floor entrance lobby as per Design & Drawing or as per Dirction by Engineer In Charge
Supply Installation testing & Commissioning of Inline type fresh air fan 200 cfm for ground floor café as per Design & Drawing or as per Dirction by Engineer In Charge
Supply Installation testing & Commissioning of Inline type fresh air fan 150 cfm for all guest rooms as per Design & Drawing or as per Dirction by Engineer In Charge
Supply Installation testing & Commissioning of Inline type fresh air fan 300 cfm for Gym Area
Supply Installation testing & Commissioning of Inline type fresh air fan 150 cfm for Management Room
Supply Installation testing & Commissioning of GI DUCTING 22 Guage ducting
Supply Installation testing & Commissioning of Cable tray with cover (150 mm x 75 mm)
Supply Installation testing & Commissioning of Flexible Ducts:
Supply Installation testing & Commissioning of Fire dampers
Supply Installation testing & Commissioning of Motorized Modulating type actuators rated for fire dampers.
Supply Installation testing & Commissioning of Control cabling
Supply Installation testing & Commissioning of Volume Control Damper
Supply Installation testing & Commissioning of Motorized Non Return Air dampers
Supply Installation testing & Commissioning of Motorized Modulating type actuators
Supply Installation testing & Commissioning of Collar Damper / Grill Damper :
Supply Installation testing & Commissioning of Fresh Air Control Damper
Supply & Installation of Dry Scrubber Fan 2010CFM cabinet Tyape
SITC of Wireless Remote
SITC of timeer for electrical room Indoor
Supply Installation testing & Commissioning of Building Flush Out as per LEED Specifications
Indoor Air Quality Assessment: It is required to establish better quality indoor air in the building after construction and during occupancy. *Flush-out with 14,000 cu.ft. of outdoor air per sq.ft. prior to occupancy - Maintain temperature between 60 F to 80 F (15 C to 27 C) - Keep relative humidity no higher than 60% - Occupancy can begin after 3,500 cu.ft/sq.ft. * Perform air quality testing to show airborne contaminants do not exceed maximum levels of Formaldehyde, Particulates (PM10), Total volatile organic compounds (TVOCs), Target chemicals from CDPH Standard Method v1.1, Carbon monoxide, Ozone (only in EPA nonattainment areas), and Particulates (PM2.5) (only in EPA nonattainment areas) For office general IAQ readings are taken for the following parameters CO2 TVOC PM2.5/10 HCHO For a typical 10000 SFT office following is good qty of readings to establish IAQ results. Gases - 10 readings Dust Track - 10 reading HCHO - 4 readings
Air balancing with all necessary tools & tackles for project
Fire Fighting Work (Extra Item)
Supply, installation, Testing & commissioning of Butterfly Valve 80 mm dia with matching flange, nut & bolt etc. Make Marc/Turbo/ Normex /Equvt or as per direction by Engineer In Charge.
Supply, Installation, testing and commisioning of Upright Sprinkler or as per direction by Engineer In Charge. Make- HD, Tyco or Equivalent
Supply, installation, Testing & commissioning of 150NB Alarm valve os per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning 9L K Type Fire extingusher ISI Mark or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of Strainer 150NB os per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of 150 mm Ductile Iron Wheel Operated Sluice Valve os per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of 100 mm Ductile Iron Wheel Operated Sluice Valve os per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of 80 mm Ductile Iron Wheel Operated Sluice Valve os per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of Air vessel os per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of Evacation map A3 Size os per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of autoglow Sinages os per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of LED Fire exit sinages os per design & Drawing or as per direction by Engineer In Charge Make - Prolight or Equivalent
Supply, installation, Testing & commissioning 80 mm Nb Flow Switch os per design & Drawing or as per direction by Engineer In Charge Make - Honywell or Equivalent
Supply Erection testing & Commissioning of Diesel Engine Driven main Pump of Horizontal centrifugal end suction backpull out type with gland packing capable to deliver 1600LPM at 56 MWC the pump shall coupled to TEFC motor of 40-HP (Contractor need to specify pump hp Based frame or as per direction by Engineer In Charge
Fire Alarm System Work (Extra Item)
Networking & CCTV System Work (Extra Item)
Supply Installation testing & Commissioning of WIFI indoor access point TP LINK Access device EAP245 or Equivalemnt as per Direction by Engineer Incharge.
Supply Installation Testing & Commissioning of Network Switches HP JL828A or Equivalent or as per Direction by Engineer In Charge.
AV System (Additional Item)
Supply & installation testing & Commessioning of of NVS WALL MOUNT SPEAKER 30W Make - Norden/Bosch/Honeywell . or As per Direction by Engineer Incharge.
Supply & installation testing & commissioning of NVS 250W Amplifier Make Norden/Bosch/Honeywell. or As per Direction by Engineer Incharge.
Supply & installation testing & Commissioning of Analog Mixing Console,10-channel Stereo Mixer Make - Yamaha /Bosch/ahuja .or As per Direction by Engineer Incharge.
Supply & installation testing & Commissioning of wireless Handled Cardioid Microphone Sennheiser Make or As per Direction by Engineer Incharge.
Supply Installation testing & Commissioning of wireless lavalier microphone Sennheiser Make .
Supply Installation testing & Commissioning of 16 Gauge Standard High Recusation Speaker cable 100 Mtr Policab or equivalent. or As per Direction by Engineer Incharge.
Supply Installation testing & Commissioning of Audio Cable 3.5 to phono cable 10 Mtr Policab or equivalent. or As per Direction by Engineer Incharge.
Supply Installation testing & Commissioning of 85 inch Smart Signeges Commercial Display TV Make - LG, Samsung. Or As per Direction by Engineer Incharge.
Supply & Installation of Sennheiser Modal No- MEG 14-40-XLR Unidirectional Goosneck Microphone, or As per Direction by Engineer Incharge.
Supply Installation testing & Commessioning of HDMI Cable 5 Rmt Kramer Ultra–Slim Flexible High–Speed HDMI Cable with Ethernet,Supports Ultra–HD 4K or As per Direction by Engineer Incharge.
Supply Installation testing & Commessioning of HDMI Cable 20 Rmt Kramer Ultra–Slim Flexible High–Speed HDMI Cable with Ethernet,Supports Ultra–HD 4K or As per Direction by Engineer Incharge.
Supply Installation testing & Commessioning of HDMI Switcher for tv Oprating or as per Requiremnt of As per Direction by Engineer Incharge.
Design Edge Studio
Tathastu Infrastructure
stage.html
html • 0.02 MB
finance_841956.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .