Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC Acceptance Letter | |
| 2 | L2₹34.2 L+₹1.5 L (4.57%)Rejected-Finance | L2 | Rejected-Finance being other than lowest | |
| 3 | L3₹35.9 L+₹3.2 L (9.84%)Rejected-Finance | L3 | Rejected-Finance being other than lowest | |
| 4 | L4₹37.6 L+₹4.9 L (15.1%)Rejected-Finance | L4 | Rejected-Finance being other than lowest | |
| 5 | L5₹38.2 L+₹5.5 L (16.8%)Rejected-Finance | L5 | Rejected-Finance being other than lowest |
| Sl No | Description | Qty | Unit | RISING SUN ENGG WORKS H2 | M/S TAJ DIN KHARI H6 | M/S PARVEZ AHMAD LONE H3 | M/S AIJAZ ENTERPRISES H8 | Javeed Builders H1 | GHULAM NABI GILKAR AND CO H5 | Concept Engineering & Constructions H4 | M/S BASHIR AHMAD MIR H7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface dressing n exc15 cm deep and getting out in hard/ dense soil, complete all as specified and directed . | 224 | SQUARE METRE | 30 ₹6,720 Lowest | 30 ₹6,720 Lowest | 100 ₹22,400 | 50 ₹11,200 | 50 ₹11,200 | 120 ₹26,880 | 70 ₹15,680 | 70 ₹15,680 |
| 2.00 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for fdn for shafts, cills, cesspits, manhole pier holes n.exc 10Sqm on plan and getting out in hard/dence soil, complete all as specified and directed. | 28.35 | CUBIC METRE | 210 ₹5,953.5 | 200 ₹5,670 | 150 ₹4,252.5 Lowest | 150 ₹4,252.5 Lowest | 200 ₹5,670 | 210 ₹5,953.5 | 200 ₹5,670 | 200 ₹5,670 |
| 3.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm,complete all as specified and directed. | 22.65 | CUBIC METRE | 100 ₹2,265 | 200 ₹4,530 | 200 ₹4,530 | 50 ₹1,132.5 Lowest | 50 ₹1,132.5 Lowest | 150 ₹3,397.5 | 100 ₹2,265 | 50 ₹1,132.5 Lowest |
| 4.00 | Removing excavated materials n.exc 50 m and depositing where directed at a level n exc 1.5m above the starting point, complete all as specified and directed. | 26.45 | CUBIC METRE | 100 ₹2,645 | 200 ₹5,290 | 200 ₹5,290 | 50 ₹1,322.5 | 10 ₹264.5 Lowest | 300 ₹7,935 | 150 ₹3,967.5 | 50 ₹1,322.5 |
| 5.00 | M&L for Moorum/red bajri filling in floors orpavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering , complete all as specified and directed. | 168 | CUBIC METRE | 1,000 ₹1,68,000 | 800 ₹1,34,400 | 1,500 ₹2,52,000 | 500 ₹84,000 | 1,500 ₹2,52,000 | 580 ₹97,440 | 1,200 ₹2,01,600 | 300 ₹50,400 Lowest |
| 6.00 | M&L for formwork to sides of concrete foundations, footings, bases ofcolumns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed | 125 | SQUARE METRE | 260 ₹32,500 | 250 ₹31,250 | 300 ₹37,500 | 150 ₹18,750 | 100 ₹12,500 Lowest | 220 ₹27,500 | 275 ₹34,375 | 100 ₹12,500 Lowest |
| 7.00 | M&L for Formwork to sides of pillars,posts, struts, piers, columns and stanchions fair and finished surfaces, complete all as specified and directed. | 130 | SQUARE METRE | 210 ₹27,300 | 250 ₹32,500 | 400 ₹52,000 | 150 ₹19,500 | 100 ₹13,000 Lowest | 200 ₹26,000 | 300 ₹39,000 | 150 ₹19,500 |
| 8.00 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. | 38 | SQUARE METRE | 300 ₹11,400 | 250 ₹9,500 | 500 ₹19,000 | 150 ₹5,700 Lowest | 150 ₹5,700 Lowest | 200 ₹7,600 | 300 ₹11,400 | 300 ₹11,400 |
| 9.00 | M&L for RCC (Reinforced cement concrete) type B1 1:2:4 (Nominal mix) (using 20mm graded stione aggregate) as in Foundation, including raft footings, bases for column,plinth beam, etc and mass concrete, complete all as specified and as directed. | 9 | CUBIC METRE | 7,000 ₹63,000 | 5,500 ₹49,500 | 5,000 ₹45,000 | 5,500 ₹49,500 | 4,500 ₹40,500 Lowest | 5,500 ₹49,500 | 6,500 ₹58,500 | 5,000 ₹45,000 |
| 10.00 | M&L for RCC (Reinforced cement concrete) type B1 1:2:4 (Nominal mix) (using 20mm graded stione aggregate) as in Columns, pillars, piers, posts and struts, complete all as specified and as directed. | 16 | CUBIC METRE | 7,000 ₹1,12,000 | 5,500 ₹88,000 | 5,000 ₹80,000 Lowest | 5,500 ₹88,000 | 5,000 ₹80,000 Lowest | 6,000 ₹96,000 | 7,500 ₹1,20,000 | 6,000 ₹96,000 |
Tender Value
₹42.6 L
EMD Value
₹85,120
Closing Date
21 Aug 2025, 6:00 pmClosed
GE 864 EWS
GE 864 EWS, C/o 56 APO
CONSTRUCTION OF COVERED SHED TO ACCOMMODATE WPN DISPOSAL SYS AT BB CANTT, SRINAGAR
2025_MES_723790_1
864/WS-43(T)/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE 864 EWS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹85,120
Yes
13 Sept 2025
31 Jul 2025
28 Aug 2025
31 Jul 2025
21 Aug 2025
14 Aug 2025
Amount
Surface dressing n exc15 cm deep and getting out in hard/ dense soil, complete all as specified and directed .
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for fdn for shafts, cills, cesspits, manhole pier holes n.exc 10Sqm on plan and getting out in hard/dence soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm,complete all as specified and directed.
Removing excavated materials n.exc 50 m and depositing where directed at a level n exc 1.5m above the starting point, complete all as specified and directed.
M&L for Moorum/red bajri filling in floors orpavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering , complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases ofcolumns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed
M&L for Formwork to sides of pillars,posts, struts, piers, columns and stanchions fair and finished surfaces, complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed.
M&L for RCC (Reinforced cement concrete) type B1 1:2:4 (Nominal mix) (using 20mm graded stione aggregate) as in Foundation, including raft footings, bases for column,plinth beam, etc and mass concrete, complete all as specified and as directed.
M&L for RCC (Reinforced cement concrete) type B1 1:2:4 (Nominal mix) (using 20mm graded stione aggregate) as in Columns, pillars, piers, posts and struts, complete all as specified and as directed.
M&L PCC 1:4:8 type D2 (40 mm graded Crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks, old size, straight or curved on plan to any radius in brick thick walls, built in Cement mortor 1:6, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant priming paint, complete all as specified and directed
Preparation of newly plastered wall surfaces by using necessary filling compound of Altek/ Birla white 1mm thick wall care putty to obtain smooth/even surface using sand paper and applying two coats of oil bound dismater over a coat of primer, complete all as specified and directed.
Rendering15mm thick plastering in cement mortar 1:6 on fair faces of brick or concrete surface finished even and smooth without using extra cement in patchy exc 3 Sqm each, complete all as specified and directed.
S/F for 0.63mm Pre painted Galvanised, Corrugated Mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts and washers, ISI marked,, in roofs, walls etc. with grade of zink coating 275, complete all as specified and directed.
S/F 0.63 mm thick Plain, galvanized mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) of class-2, ISI Marked, complete all as specified and as directed.
Supply and fixing roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc fixed in position,conforming to Fe-410(Gde 250), complete all as specified and as directed.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape reqd and binding with and including MS wire not less than 0.9mm dia or securing with clips in footing and RCC flooring, complete all as specified and directed.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape reqd and binding with and including MS wire not less than 0.9mm dia or securing with clips in column, complete all as specified and directed..
M&L for TMT bars 8 mm dia in stirrups and over, cut to length, bent to shape reqd and binding with and including MS wire not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Providing and fxing powder coated aluminium (mMinimum thickness of powder coating 50 micron) work for, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/appropriate Z sections/3 truck and other sections of approved make conforming to IS:733 and IS : 1285, fixing with dash fastenners of required dia and size, including necessary filling up the gaps at junction, i.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing/paneling, C. P brass/Stainless steel screws, complete all as spcified ad as directed.
M/L 75mm thick PCC 1:3:6 type C-1, as in plinth protection, laid in panels of area not exceeding 2.00 sqm with 6mm wide joints filled with mastic (using bitumen and sand mixture applied hot in the ratio of 1:3 by weight) formed at the end of each panel and change in direction of plinth protection/PCC Path and paving and finishing the top surface even and smooth without using extra cement complete all specified and as directed.
M/L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for 80 mm thick machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006, M-40 with grey cement and no pigment over 50mm thick PCC 1:2:4, type B-2 (Using 40mm graded crushed stone aggregate), complete all as specified and directed.
M&L for Sand cushioning for laying interlocking paver blocks on footpath including watering and consolidation completre all as specified and directed.
S&F Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated,complete: gear operated type with bevel gear box and crank handle, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5mtr in depth & getting out any type of soil, complete all as specified and directed.
M&L for plain cement concrete 1:2:4 Type B-1 (using 20mm graded crushed stone aggragate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughts and the like including weathering, slightly rounded or chamfered angles and thoroating, complete all as specified and directed.
Removing excavated material exceeding 250m and not exceeding 500 m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
M&L for making single phasing point wiring system used as copper conductor wire for phase and neutral wiring system the wire made out of PVC insulated Flame Proof Wire FRLS of 1100 volt grade with having multistranded copper conductor wire of size 1.5 Sq.mm (Nominal area) ISI marked drawn through wiring system surface on wall or concealed in wall with the help of heavy duty ISI mark PVC casing capping strip / PVC conduit pipe ISI mark in any lengthy wiring system and along with its all connected fittings accessories including providing of pressed steel terminal sunken boxes or heavy duty PVC box and duly fixed it concealed in wall or surface on wall and alongwith providing of back and face top covered plate frame or electro plated plastic laminated sheet for housing / mounting of any type/size switches sockets, regulators etc and including using /drawing of one run of single wire 1.5 sqmm PVC insulated FRLS wire 1100 volt grade ISI marked with multistranded copper conductor wire used as a continuous earth wire for point wiring complete system and including making the good to all disturbed surfaces of wall/ceiling area of new wiring system and to match to it as per the existing surface of wall/ceiling etc,for one light point / fan point wiring system controlled by one way switch, complete all as specified and directed.
S & F for Switch flame proof rotary type with termination box in LM6, 16 A,single pole 250 volt, complete all as specified and directed.
Supply and fixing ceiling rose three terminals type made out of polycarbonate , isolated body complete all as specified and directed.
S & F LED light fitting 1x16 watt flame proof, CMRI certificate recommended for gas/vapor group of II A & III B, Zone 1 & 2 and IP 65. protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc.Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S & F for LED light fitting LED Bulk head of sizes 30 watt flame proof cum water proof CMRI certificate recommended for gas/vapor group of II A & III B, Zone 1 & 2 and IP 65. protection including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing of sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrengment system suitable of size/type of distribution board of rating SPN 4 way type 220 volt AC supply system with IP protection rating with ISI marked and having neutral and earth link bus bar and mounting base chanel suitable for holding MCBs incommer and outgoing system complete set all as specified and directed.
Supply and fixing of MCB SP 40 to 63 Amps with breaking capacity 10KA 'C' Curve series, 220 Volts, 50 Hz AC supply complete and also making suitable size / type of electric wiring coneenection, complete all as specified and directed.
Supply and fixing of MCB SP 06 to 32 Amps with breaking capacity 10KA 'C' Curve series, 220 Volts, 50 Hz AC supply complete and also making suitable size / type of electric wiring coneenection, complete all as specified and directed.
Supply, laying and testing of LT cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volt grade laid in trenches or fixing on poles or passing through pipes, cross sectional area of size 10 sqmm 2 core , complete all as specified and directed.
Supply and fixing of GI water tubing 25 nmm bore light grade galvanised with all fittings like socket, union, elbow, bend, etc jointed and laid in trenches , complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out, complete all as specified and directed.
Material and labour for sand cushioning with a layer of sand (Locally available river sand) 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches, below and above / around UG cable for cable protection, complete all as specified and directed. Note - Punned thickness shall only be measured and paid.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other, complete all as specified and directed.
M&L for earthing work complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level and connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers of galvanised steel and to be protected by GI pipe 15 mm bore light grade & connected to earth test point/main switch board or main control board and also providing charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil all as shown in Electrical Plate No 3 of SSR part -I. and also making arrangment of 20 mm dia bore galvanised iron pipe (medium grade) for water and making funnel, wire mesh,and also including provision of concrete pit cover framing work in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and outer frame work of angle iron 25x25x6mm with top concrete pit cover and handle for lifting of cover, complete work all as specified and directed .
RISING SUN ENGG WORKS (BID ID -3401695)
M/S PARVEZ AHMAD LONE (BID ID -3401587)
Concept Engineering & Constructions (BID ID -3401163)
GHULAM NABI GILKAR AND CO (BID ID -3400006)
M/S TAJ DIN KHARI (BID ID -3398496)
M/S BASHIR AHMAD MIR (BID ID -3401455)
M/S AIJAZ ENTERPRISES (BID ID -3401196)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .