Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.8 LAccepted-AOC 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | 1 | Accepted-AOC L1 | |
| 2 | 2₹8.5 L+₹73,800.40 (9.52%)Rejected-AOC 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | 2 | Rejected-AOC L2 | |
| 3 | 3₹8.5 L+₹74,396 (9.60%)Rejected-AOC | 3 | Rejected-AOC L3 | |
| 4 | 4₹9.8 L+₹2.1 L (26.9%)Rejected-AOC | 4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹13,000
Closing Date
17 Jun 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle-II, U.P. Power Transmission Corporation Ltd. 57- George Town, Prayagraj
14/ETC-II(P)/ 2021-2022
2021_UPTCL_593719_1
14/ETC-II(P)/ 2021-2022
Open Tender
Electrical Works
Item Rate
90 days
Manjhanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE,ETD-NAINI,PRAYAGRAJ
₹13,000
18 Sept 2021
10 Jun 2021
18 Jun 2021
10 Jun 2021
17 Jun 2021
10 Jun 2021
120 days
Amount
Part "A" Supply of Hardware & fittings
Supply of 5 No. U-Bolted type Single Tension Fitting Assembly, suitable for Single ACSR Panther Conductor & 132 KV Disc Insulator String comprising of 10 No. 70 KN Disc Insulators, complete with Hardware Fittings, D-Shackle, Socket Eye, Ball Hook, Tension Clamp etc. as per Sample.
Supply of 5 No. U-Bolted type Single Tension Fitting Assembly, suitable for Single ACSR Moose Conductor & 132 KV Disc Insulator String comprising of 10 No. 120 KN Disc Insulators, complete with Hardware Fittings, D-Shackle, Socket Eye, Ball Hook, Tension Clamp etc. as per Sample.
Supply of 5 No. U-Bolted type double tension Fitting Assembly, suitable for twin ACSR moose Conductor & 33 KV Disc Insulator String comprising of 04 No. 70 KN Disc Insulators, complete with Hardware Fittings, D-Shackle, Yoke plate, Socket Eye, Ball Hook, Tension Clamp etc. as per sample.
Supply of 132 KV post insulator clamp duly made of LM-6 Aluminium alloy, suitable for 132 KV post insulator & single ACSR panther conductor, complete with G.I. Bolts, Nuts, spring & plain washer etc. as per sample.
Supply of 132 KV single suspension fitting for panther conductor duly made of LM-6 Aluminium alloy as per sample.
Supply of Spacer suitable for twin ACSR Moose conductor made of LM-6 Aluminium Alloy complete with G.I. Bolts, Nuts, & washers as per sample.
33 KV Isolator clamps suitable for twin ACSR Moose conductor duly made of LM-6 Aluminium alloy as per sample.
M.S. Earthing strip (50x6 mm)
Part "B" Work.
Sorting, Counting & loading of main and auxiliary sub station structure on the contactor,s private vehicle at E.F.U. Naini Prayagraj.
Safe carriage of Main and Auxiliary sub station structure from EFU Naini Prayagraj to 132 KV S/S Manjhanpur Kaushambi on full/Partial load Truck basis (01 Truck=01 Job )Total distance -85 Km Approx.
Unloading & proper stacking of above main and auxiliary sub station structure at 132 KV S/S Manjhanpur Kaushambi.
Safe dismantaling of 2x5 MVAR Capacitor bank unit-1 and its associated Bus, equipments, structures at 132 KV S/S Manjhanpur Kaushambi. The job includes opening of control cables, dismantaling of above capacitor bank & its associated equipment, cutting of earthing strips with the help of gas cutter and safe shifting of all equipments including earthing strips from site to sub station store or as per instruction of supervising engineer, as per details given below.
33KV VCB
Capacitor bank reactors (02 Job for each set of 5 MVAR)
Capacitor bank cell unit alongwith structure (01 Job for each set of 5 MVAR)
Single ACSR Moose conductor Bus bar of 2x5 MVAR Capacitor Bank
All jumpers of Capacitor Bank Bay
36 KV NCT
36 KV Isolators (01 LI & 02BI)
Main & auxiliary structure
Opening of control cable termination in VCB, CT, NCT, isolators and C&R Panel of Capacitor Bank feeder.
Complete taking out of following size control cables from cable trenches between control room and capacitor bank bay & its stacking in store as per detail below:-
2C x 2.5 sq. mm
4C x 2.5 sq. mm
6C x 2.5 sq. mm
Opening of control cable termination in CB, isolators and Control panel of 132 KV TBC feeder.
Complete taking out of following size control cables from cable trenches between control room and Transfer Coulper Bay & its stacking in store as per detail below:-
2C x 2.5 sq. mm
6C x 2.5 sq. mm
10C x 2.5 sq. mm
Erection of following structures & equipments including their shifting from storage place at the sub station to erection site.
Main & auxiliary structure
132 KV SF-6 C.B.
33 KV VCB
132 KV C.T Junction box
33 KV CT Junction box
132 KV P.T. Junction box
132 KV Bus Isolator with associated Post Insulator.
132 KV Tandem Isolator with Post Insulator.
132 KV Post Insulator
33 KV Bus Isolator (01 No for Capacitor Bank & 01 No For T/F & 01 No for Bus Section)
33 KV Line Isolator (for Capacitor Bank )
Capacitor bank reactors
Capacitor bank cell unit along with structure (01 Job for each set of 5 MVAR)
132 KV Transformer Control & Relay Panel
33 KV NCT for Capacitor bank
ABT Energy Meter Cubical
Laying & Stringing of 132 KV 3f Jack Bus Bar with single ACSR Panther conductor including Hoisting of Disc Insulator Strings, Tension Fittings etc. alongwith shifting of the Conductors/Materials from Storage Place at the Sub Station to Erection Site (01 job per phase per section)
Laying & Stringing of 132 KV 3f Main Bus Bar with Single ACSR Moose Conductor including Hoisting of Disc Insulator Strings, Tension Fittings etc. alongwith Shifting of the Conductors/Materials from Storage Place at the Sub Station to Erection Site. (01 job per phase per section)
Laying & Stringing of 132 KV 3f Transfer Bus Bar with Single ACSR Panther conductor including Hoisting of Disc Insulator Strings, Tension Fittings etc. alongwith Shifting of the Conductors/Materials from Storage Place at the Sub Station to Erection Site. (01 job per phase per section)
Laying & Stringing of 33 KV 3f Bus Bar with Twin Moose Conductor including Hoisting of Disc Insulator Strings, Tension Fittings, connecting spacers etc. alongwith Shifting of the Conductors/Materials from Storage Place at the Sub Station to Erection Site. (01 job per phase per section)
Laying & Stringing of 33 KV 3f Bus Bar with Panther Conductor for 33 KV Capacitor Bank including Hoisting of Disc Insulator Strings, Tension Fittings etc. alongwith Shifting of the Conductors/Materials from Storage Place at the Sub Station to Erection Site. (01 job per phase per section)
Jumpering of 132 KV TBC Bay with the Help of single ACSR Panther Conductor to Connect with diffirent Equipments and Equipments to Equipments with the Help of suitable Clamps/Connectors including fabricting of jumpers by the way of Cutting, straightening, Bending & Shaping etc. of the Conductor as per site Requirement alongwith shifting of required materials from storage place to erection site.
Jumpering in 132 KV side Bay of 63MVA Transformer with the Help of single ACSR Panther Conductor to Connect the Bus Bar Conductor of Transfer Bus & Jack Bus with Equipments and Equipments to Equipments with the Help of suitable Clamps / Connectors including, Cutting, Bending, Shaping etc. of the Conductor as per site Requirement alongwith shifting of required materials from storage place to erection site.
Jumpering in 33 KV side Bay of 63MVA Transformer with the Help of Twin ACSR Moose Conductors to Connect the Bus Bar Conductors of Main Bus with Equipments, Equipments to Equipments with the Help of suitable Clamps/Connectors including, Cutting, Bending, Shaping etc. of the Conductor as per Site Requirement.
Jumpering in 33 KV 2X5 MVAR Capacitor Bank with the Help of ACSR Panther Conductors to Connect the Bus Bar Conductors of Main Bus with Equipments, Equipments to Equipments with the Help of suitable Clamps/Connectors including, Cutting, Bending, Shaping etc. of the Conductor as per Site Requirement alongwith Shifting of required Materials from Storage Place at the Sub Station to Erection Site.
Making of Shielding Mesh for 132 KV LAs & 33 KV LAs in 63 MVA Transformer Bay by Fabrication of 3 Meter long Electrodes with 36/40 mm dia. M.S. Round Bar having 150 mm Long Conical Shape and then its Piercing Vertically in the Ground with Top 500 mm below the Ground Level, Jointing the Electrodes with 75×10 mm size M.S. Flat by Welding for Making of Mesh, Connecting the Shielding Mesh with Main Earth Mat at 2 Places and Finally, Painting of the Shielding Mesh/Earthing Strips with Anti-Corrosive Paint, with due Digging of Earth/Trench & its Back Filling etc. as per Details below :-
Making of shielding mesh with with 6 Nos electrodes for 132 KV LAs
Making of shielding mesh with with 4 Nos electrodes for 33 KV LAs
Earthing by Cutting, Straightening & Laying 500 mm below Inside Ground & above Ground of Following sizes M.S. Flats for Diagonal/Double Earthing of the Main & Aux. Structures, Equipments etc. in 132 KV & 33 KV sides of 63 MVA Transformer CB, VCB, CT, PT etc., including Welding with Main Earth Mat and with the Object to be Earthed including Excavation of Trenches & its Back Filling etc. as per Details below:-
Earthing by 75×10 mm size M.S. Flat
Earthing by 50x6 mm size M.S. Flat
Earthing of main and auxiliary structure & all equipments of 2x5 MVAR Capacitor bank by Cutting, Straightening & Laying 500 mm below Inside Ground & above Ground of Following sizes M.S. Flats for Diagonal/Double Earthing of the Main & Aux. Structures, Equipments, including Welding with Main Earth Mat and with the Object to be Earthed including Excavation of Trenches & its Back Filling etc. as per Details below:-
Earthing by 50x6 mm size M.S. Flat
Earthing of 132 KV TBC bay Including its main & auxiliary structures by Cutting, Straightening & Laying 500 mm below Inside Ground & above Ground of Following sizes M.S. Flats for Diagonal/Double Earthing of the Main & Aux. Structures, Equipments, including Welding with Main Earth Mat and with the Object to be Earthed including Excavation of Trenches & its Back Filling etc. as per Details below:-
Earthing by 50x6 mm size M.S. Flat
Earthing by 75×10 mm size M.S. Flat
Laying of Following Sizes Control Cables in Cable Trenches from Transformer Control & Relay Panel, Capacitor Bank C&R Panel and TBC control panel in Control Room to various aossciated Equipments, Junctions Boxes etc. in Switchyard as per Cable Schedule including Shifting of the Control Cable in Drums from Storage Place at the Sub Station to Erection Site and Shifting Back the Balance Control Cables/Drums to Stores at the Sub Station:-
2Cx2.5 sq. mm
4Cx2.5 sq. mm
6Cx2.5 sq. mm
Termination of various Sizes above Laid Control Cables, Extending D.C. Supply from DCDB and A.C. Supply from ACDB to Control & Relay Panel, Transformer Protection Panel and Equipments including Drilling of Holes, Providing & Fixing of Cable Glands, Ferrules & Crimping Lugs after Preparing Cable Schedule in 132 KV & 33 KV sides of the Transformer as per Details below:-
132 KV Side
33 KV Side
Termination of various Sizes above Laid Control Cables, Extending D.C. Supply from DCDB and A.C. Supply from ACDB to Control Panel and Equipments of TBC Bay including Drilling of Holes, Providing & Fixing of Cable Glands, Ferrules & Crimping Lugs after Preparing Cable Schedule.
Termination of various Sizes above Laid Control Cables, Extending D.C. Supply from DCDB and A.C. Supply from ACDB to Control Panel and Equipments of Capacitor Bank Bay including Drilling of Holes, Providing & Fixing of Cable Glands, Ferrules & Crimping Lugs after Preparing Cable Schedule.
Providing and fitting of new generation energy & environment friendly long aluminium outdoor beam street light with high power 120 watt LEDs as light source & exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 230 volt AC input supply of CGL/Havell’s/Surya/Phillips/Bajaj etc. including wiring from junction box to light fitting point and checking of healthiness of LEDs light.
Providing & fixing of junction box on round of size 100x200x150 mm of M.S. Sheet of 18 SWG duly painted with synthetic enamel paint. Box should hve one no. MCB of 06 & 10 Amp each and 04 No terminals fixed on backlight terminal strip.
Laying of 2x2.5/4x2.5 sq.mm PVC control cable as per requirement of size 60 cm below ground level in PVC conduit pipe after excavation and back filling including all labour, T&P and PVC conduit etc. PVC control cable will be provided by department free of cost.
Laying of 2x2.5/4x2.5 sq.mm PVC control cable from junction box to LED light fitting. Cable will be provided by UPPTCL free of cost.
Hi-tech power transmission
HARE KRISHNA ENERGY PROJECTS
TARUN ENGINEERING WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .