Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.1 LAccepted-AOC | ₹47.1 L Quoted ₹47.8 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹50.4 L+₹2.6 L (5.52%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹50.4 L+₹2.6 L (5.52%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Being not enlisted in b(i) category |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
30 Apr 2024, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT TO SUNKEN FLOOR TREATMENT ROOFING FALSE CEILING SANITARY FITTINGS AND INCLUDING CERTAIN ELECTRICAL REPAIR WORKS AT AFS JALAHALLI
2024_MES_649031_1
8896/E8
Open Tender
Electrical and Maintenance Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹1 L
27 Jun 2024
2 Apr 2024
2 May 2024
2 Apr 2024
30 Apr 2024
16 Apr 2024
2 Apr 2024 - 9 Apr 2024
Amount
Treatment of the sunken floor slab comprises of the following specifications and all as directed by Engr-in-Charge. Make :- Dr Fixit/ M/s Sika india Pvt Ltd/ STP Ltd/ M/s Fosroc Chemicals
(a) Demolition of cement concrete filling of any description in sunken portion in toilet and removing debris outside MD land.
(b) Cleaning the sunken/ lowered portion of RCC slab surfaces (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provinding 40mm thick avg thickness PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout (WPC shall be measured and paid separately)
(c) Rendering of uneven surfaces with 10mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured and paid separately).
(d) All junctions points of side wall spout where CI/ GI pipes are passing through shall be sealed with epoxy putty.
(e) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
(f) Material and labour for applying two coats of polymer modified cementious water proof coating as per manufacture's instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion complete all as specified and directed (This item shall be measured and paid separately).
(g) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound @3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately).
(h) Material and labour for PCC 1:5:10 type E2, using 40mm graded aggregate n exc 150mm thick, complete all as specified and directed.
(j) Material and labour for PCC 1:2:4 type B0 using 12.5mm graded aggregate, 50mm tnick, complete all as specified and directed.
Note :- Test the water proof area (ponding test) by filling water for at least 72 hours and tested for leakage, seepage to the entire satisfaction of GE. Test shall be done in presence of Reps of Engineer-in-Charge and contractor. The treatment shall be carried out by authorised applicator of chemicals. Cost of testing is included in the unit quoted rate above.
Supply Only integral water proofing compound complete all as specified and as directed. Make:-Dr. Fixit Pidi Proof and equivalent.
M&L Repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damaged portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed by Engineer-in-Charge
M&L Repair of leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damaged soil waste pipes or fittings of any shape, specification and size, making good to the damaged portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and finished the surfaces matching to existing wall, complete to avoid the leakage/ seepage at the site of work as directed and as specified.
Note for item No 13 & 14 :- (a) Find out main cause of leakage and take necessary steps to resolve / rectify. (b) Replace existing tiles in case leakage through NT/FT. (c) The rate also include provision of new NT/FT. (d) The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as directed by the manufacturer's specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit
Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down 15mm bore steel tubing galvanized and connection, complete all as specified and directed.
Supply and fixing 20 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down 20mm bore steel tubing galvanized and connection , complete all as specified and directed.
Supply and fixing 25 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down 25mm bore steel tubing galvanized and connection, complete all as specified and directed.
Petty repair to internal/external inlet water GI/CPVC pipe line of any size coming from over head tank to the quarter including socket,elbow,nipple ,with repair to water blockage , pipe line leakage, cleaning internally , removing of air/dust blockage including concealed water tubing etc n exc 3m length of any height using scaffolding and and making the water supply functional, complete all as specified and directed.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and taking out steel/plastic/CPVC water tubing and connections including cleaning for refixing 15 mm/20mm dia , all as directed..
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and taking out steel/plastic/cpvc water tubing and connections including cleaning for refixing 25mm dia,all as directed.
Supplying and fixing in repairs of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC, complete all as specified and directed.
Supplying and fixing in repairs of 25mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC, complete all as specified and directed.
Supplying and fixing in repairs 20mm outer dia CPVC brass elbow , complete all as specified and directed.
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and M&L for Joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile of size n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4), complete all as specified and directed.
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and Material and labour for Glazed ceramic coloured tiles 350x250mm/ 450 x 300 mm x 7/8 thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as skirting/ dado including 10mm thick 1:3 backing coat, complete all as specified and directed.
Material and labour for 25 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in flooring surface and smooth without using extra cement, including demolition of existing cement concrete & including disposal of demolition material upto MD land, complete all as specified and directed by Engineer- In - charge.
Complete removal of existing water proofing treatment of any description and in any position including PCC padding of any thickness and cleaning, wire brushing, watering & removal of debris outside MOD, complete all as specified and directed. NOTE :- Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight).
Roughening surfaces of old concrete floors by picking, sweeping clean and washing down with water to remove dusts etc,, complete all as specified and directed.
M&L for Brushing with neat cement slurry @ 3kg/Sqm, complete all as specified and directed.
M&L PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in concrete padding laid to required slope incl finishing the concrete surface fair and even without using extra cement, complete all as specified and as directed.
M & L for 10 mm thick screed bed or bedding layer of mortar in cement mortar (1:4) for laying roof finish as padding finished with WPC @3% by weight of total cement, complete all as specified and directed NOTE :- Integral WPC shall be measured and paid separately.
Apply oil bound bitumen primer @ 0.40 Litre / Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg / Litre at 25 degree Celsius on the prepared dry roof surface.
M&L APP polymeric membrane min weighting 3.0kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/Sqm laid on primed surfaces by torch application method complete all as specified and directed.
M&L for preparation of new roof surfaces of any description not otherwise described over 10cm width or girth and applying two coats of solar reflective aluminium paint @ 0.10 Kg/Sqm of membrane surfaces complete all as specified and directed
Supply Only water proofing compound complete all as specified and as directed.
Supply and fixing Anodized aluminium of size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with hangers of 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and 6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium/G.I./ M.S.as per specification and drawing and including dismantling old unserviceable wall and ceiling board & including frame of any type and description, complete all as specified and directed.
M&L for Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat OF oil bound distemper, complete all as specified and as directed.
S&F Plate rack of size 65 cm x 96 cm made of stainless steel fixed in repairs,, complete all as specified and directed.
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm fixed in repairs, complete all as specified and directed. Make : M/s Diamond / Nirali / Amco / TATA or equivalent.
S & F in repairs Bib taps fancy type chromium plated with crutch or butterfly handle screwed down screwed for galvanised iron pipe or for brass ferrule and fixed for 15 mm bore, complete all as specified and directed.
S&F in repairs of Push tap any colour high pressure of PTMT screwed for iron pipe and fixed, (Minimum weight 15mm-47gms), complete all as specified and directed by Engineer in Charge.
S&F in repairs of pillar tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-110gms) , complete all as specified and directed by Engineer in Charge.
S&F in repairs 15 mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe complete as directed by Engr-in-charge.
S&F in repair Brass Chromium plated wall mixer for mixing hot & cold water screwed down for 15mm bore iron pipe, complete all as specified and directed .
Dismantling wrought iron or mild steel work of any description and in any position , complete all as specified and directed.
Supply and fixing MS tubes/Square bars/Angle square bar iron using various sections such as poles, rafters, purlins ladders and cleats as directed by Engineer-in-Charge and all specified.
Material and labour for preparation of new steel surfaces and iron work of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint, complete all as specified and as directed.
S&F 32 mm bore Waste Coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed including taking down existing one, complete all as specified and directed by Engineer- In - charge.
S&F PVC connections 15mm size with PTMT nuts of length 600 mm including taking down existing one, complete all as specified and directed by Engineer- In - charge.
S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kgf/Sqcm fixed complete to walls, ceiling or laid in floors, complete all as specified and directed.
S & F in repair PVC waste pipe 32 to 40 mm dia and length n exc 2m for WHB/Sink/ Urinal up to floor trap and fixed, complete all as specified and directed.
S&F Vitreous china squatting pan 'Orissa' Pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe ) including provision of lime cement concrete bedding fixed in repairs, complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including taking down existing one, complete all as specified and as directed.
S&F Angular stop cock, valves high pressure screwed both ends iron pipe or for unioins 15mm dia, including taking down existing one, complete all as specified and directed by Engr-in-charge.
S&F Wash basin vitreous china (flat back and angle back type) size 580x400mm including taps, waste chain and plug and porceline stopper but brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe ,fixed including taking down existing one, complete all as specified and directed by Engr-in-charge.
S&F Vitreous china wash down water closet pan (pedestal pattern), white (exluding fixing bolts,flushing cistren and flushpipe) and including seat cover for pedestal pattern, complete fixed in repair, all as specified and as directed.
S&F in repair PVC flush ceramic colour cistern , low level, 10 litres capacity, star white with inlet float ball valve, PVC flush pipe and handle, making proper fixing and hanging arrangements (Make: /Parryware/Hindware/ Cera), complete all as specified and directed.
S&F in repairs of Stop Valve standard of PTMT any colour high pressure screwed foriron pipe and fixed.(Minimum weight 15mm-90gms) , complete all as specified and directed by Engineer in Charge.
S&F in repairs Overhead Shower rose ø125mm (Brass Chrome Plated), complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, chajja,ceiling, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash, complete all as specified and directed.
S & F in repair Toilet paper holder box type of vitreous china fixed to walls with chromium plated (CP) brass screws, complete all as specified and directed.
Supply and fixing in repairs plastic water closet seat cover white or tinted, closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinge device and including taking down existing one, complete all as specified and directed by Engr-in-charge.
S&F in repairs of Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-90gms) , complete all as specified and directedby Engineer in Charge.
S&F in repairs of Swivel Shower with arm of PTMT any colour and 195mm long bend of 45 degree with flange for fixed with 15mm pipe (Minimum weight15mm-90gms) , complete all as specified and directed by Engineer in Charge.
S&F 150 mm dia round/square grating of CP with or without hole including Jointed to PVC pipe, complete all as specified and directed.
M&L for Preparation of old painted wooden surface of any description and applying one coat of synthetic enamel paint using mechanical means, not otherwise described over 10 cm width or girth, complete all as specified and directed.
M&L for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paint using mechanical means over 10 cm width or girth, not other wise described, complete all as specified and as directed.
M&L for Preparation of old decorated surfaces of walls by using pressure washer, remove all dirt & dust ,applying one coat of wall care putty and then applying two coats of premium oil bound distemper over one coat of primer as per manufauture instruction of required shade, complete all as specified and directed by Engineer - in - Charge. Note:-(i) Cost of scaffolding required is deemed to be included in the quoted rate of this item and nothing extra shall be admissible on this account.
Petty repairs to refixing the existing Wash hand basin and Sinks made of stainless steel 1mm thick kitchen flat back with and including fixing cantilever CI/Angle iron brackets embedded in concrete block including connecting waste coupling 32mm bore, including bedding, waste fitting, waste pipe in cement mortar on dwarf wall and connecting union to pipe, filling gap in white cement and all necessary fittings to fixed in repair (including taking down and refixing the same position) complete all as directed.
S & F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws and including dismantling of any type of old sheets in roof coverings complete all as specified & directed.
S & F Pre- painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws & included dismantling of old any type of sheets in roof coverings complete all as specified & directed.
Supply and fixing in repairs 7 feet 4 pipes pulley operated cloths drying system consisting of aluminium pipe of outer dia 22mm, inner dia 19.80mm, made up of detrin with rope guide mounted on channel pair of length 24 feet (distance between two pipes is adjustable) locking system to hide rope knot, channel to be mounted or fixed with self taping screws provided in kit. Rope will be HDPE double core of 4mm dia fixing to ceiling as specified and directed by Engr-in-Charge and minimum weight of one pipe shall not be less than 0.20kg/, minimum weight of rope shall not be less than 7700Gms/unit .
Supply and fixing in repairs 20mm dia gun metal gate valve with iron wheel screwed both ends for iron pipe , complete all as specified and directed.D82
S & F in repair Ball valves 25mm bore high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe & fixed. (minimum weight -210 gms) complete all as specified and directed.
M&L for 75mm thick,Plain cement concrete (1:3:6) type C1 (using 20 mm graded stone aggregate), as in plinth protection courses, top surface of concrete finished even and smooth with out using extra cement, including expansion joint 10mm thick filled with mastic filling comprising of 01 part of heated blown bitumen and 3 parts of dry sand including demolition of existing cement concrete including disposal of demolition material upto MD land complete all as specified and directed by Engineer- In - charge.
Material and labour for Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet near pipes etc and applying acid treatment after removing roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150 Sqcm but n.exc 400 Sqcm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface, complete all as specified and directed.
Note for item No 79 :- (a) Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding. (b) Contractor shall provide safety gears to his workers at his own cost and safety pre caution to avoid accidents.
Material and labour for Dismantling the existing unserviceable gully trap including chamber and material and labour for provision of salt glazed stoneware gully trap, square or round mouth type "P" of size 180X150mm, including setting and jointing in cement mortar 1:1 plain cement concrete base in PCC 1:2:4 type B1, brick work in cement mortar 1:4 rendering in cement mortar 1:4 all around finished even and fair using extra cement RCC cover slab in RCC type B1, 1:2:4 with 6mm dia reinforcement etc, complete all as specified and as directed
Grinding of existing mozaic/kota stone/tiles in wall/flooring including mirror polishing, cleaning of tiles/granite and joints filling and apply white cement, including grouting of floor trap surroundings with white cement, complete all as specified and directed.
Repair, maintenance and making the continuity of supply after rectifying the defects of the electrical items such as light point, fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, batten, ceiling rose, pendent, any type of MCB's, DB's any type of light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection with S&F small pieces of elctrical cable of size upto 10 Sqmm single core and length not exceeding 0.50m, complete all as specified and as directed. Note : Any major items required to be repaired/replaced will be measured and paid under relevant items as supply only.Cost of labour for replacement will be deemed to include in the unit quoted rate.
Note for item No 83 :- (a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work.
(b) All bldg light complaints including service connection, sub main & internal electric for entire OTM and Md accn at AF Stn Jalahalli West shall be attended
(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format as directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs.
(d) All sort of petty T&P items such as PVC insulation tape, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor without any extra cost to deptt.
(j) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(k) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor shall be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(l) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply only switch piano flush type 5 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply only switch piano flush type 15 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply only shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed Make : Anchor, Havells, L&T
Supply only shuttered socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed Make : Anchor, Havells, L&T
Supply only switch socket combination out let 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply only switch socket combination out let 5 in 1, 5 pin 5 and 15 Amps, flush type, complete all as specified and directed.Make : Anchor, Havells, L&T
Supply only PVC insulated FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 Sqmm of 3 core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked, complete all as specified and directed
Supply only lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Supply only metal clad switch socket single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Legrand/ Havells/ Indoasian
Supply only rigid, non-metalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories, complete all as specified and as directed. Make : Avon plast/ supreme/ Diplast
Supply only bakelite sheet not less than 3 mm thick of suitable size, complete all as specified and as directed.
Supply only plug top 3 pin 5 Amps AC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply only electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/ cona/ Plaza
Supply only 7 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton
Supply only single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996, complete all as specified and directed.(Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 / Indoasian/ Havells.
Supply only PVC gang box 1 way 05 Amp, complete all as specified and directed . Make. Cona/L&T/Anchor
Supply only modular switch 1 way 6 Amp.1 module , complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor
Supply only modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor
Supply only modular switch 1 way 16 Amp.1 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor
Supply only modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor
Supply only plug top 3 pin 15 Amps AC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply only 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only electronic LED driver 46/47W suitable for 2' x 2' ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed by Engineer-in-Charge.
Supply only T-5 tube rod 28 watt, complete all as specified and directed.
Supply only PVC Casing & Capping of 15 mm (width), complete all as specified and directed.
Supply only PVC Casing & Capping of 20 mm (width), complete all as specified and directed.
Supply only bell push, pionotype 5/6 Amp, complete all as specified and directed. Make : Anchor/ Cona/ Havells
Supply only insulation tape 25 mm width 10m long (ISI Marked), complete all as specified and directed.
Supply only electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt , complete all as specified and directed Make : Havells / Anchor/ crabtree
Supply only 4' 20W/ 18W LED Retro bar tube rod suitable for existing fitting, complete all as specified and directed. Make : Philips, Bajaj, Havells,Crompton
Supply only 4 mfd condensor for exhaust fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only modular white cover plate with frame,3 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor
Supply only modular white cover plate with frame,4 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor
Supply only modular white cover plate with frame,6 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor
Supply only modular white cover plate with frame,08 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor
Supply only modular white cover plate with frame,12 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor
Supply only electronic fan regulator modular type 230 volts, step type socket type, hum free 100/240 watt, complete all as specified and directed. Make : Havells / Anchor/ Crabtree.
Supply only TPN, MCB 20 to 32 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified (Make/Model : Indoasian/Schneider/ L&T/Havells.
Supply only rigid, non-metalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories, complete all as specified and as directed. Make : Avon plast/ Supreme/ Diplast
Supply only 10 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ crompton
Supply only modular switch 1 way 32 Amp.2 module, complete all as specified and directed. Make : Legrand /Crabtree/ Anchor
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 6 Sqmm 3 core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only T-5 tube rod 14 watt, complete all as specified and directed.
Supply only PVC Casing & Capping of 25 mm (width), complete all as specified and directed.
Supply only switch socket combination outlet 3 in 1/ 3 pin 3 and 5 Amps flush type with box, complete all as specified and directed.
Supply only switch socket combination outlet 5 in 1/ 5 pin 5 and 15 Amps flush type with box, complete all as specified and directed.
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5 Sqmm of 3 core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only TPN, MCB 40 to 63 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified (Make/Model : Indoasian/ Havells/ Legrand.
Supply only SPN MCB 40 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified and directed. (Make/Model : Indoasian/ Havells/ Legrand.
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm 3 core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
Supply & fix in repair decorative recessed mounted ultra slim square profile 1X1 feet 20 W LED lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 20 Watt and including cosidering material & labour for fixing ceiling hight upto 15 Mtr, complete all as per site requirement and directed by Engr-in-Charge .
S&F in replacement factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623, all as specified. Make/Model : Legrand/Indoasian/ Standard
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor for over head service connection suspended by insulating hangers not more than one meter apart including 4 mm dia GI suspension wire, complete all as specified and directed.
S&F Surface & wall mounted LED fitting including 5 watt LED tube rod complete with all accessories internally, pre-wired, connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down old light fitting. Make : Bajaj /Philips /Havells.
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed.
M&L in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 Sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through surface PVC conduit/ existing concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 Sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch.
All as per item No. 148 here in before but for one 3 pin socket out 5 Amp on the same board
All as per item No. 148 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 148 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently.
M&L in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 Sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn PVC through Casing Capping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 Sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly, complete all as specified and as directed. Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely.
One light point/fan/bell point controlled by one switch.
All as per item No. 153 here in before but for One 3 pin socket out let 5 Amp on the same board
All as per item No. 153 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 153 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size, complete all as specified and directed. Note: (a) 4 runs of 6 Sqmm cable along with two run of 6 Sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. Make:- Havells/ Polycab/ Plaza
S&F in replacement factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623, all as specified. Make/Model : Indoasian/ Havells/ Legrand.
S& F replacement of conventional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make : CG Cat No. LPTO-40-CDL/Bajaj Cat Part No. BRIL 45 W LED NW or equivalent in philips.
S&F in replacement on distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1, complete all as specified and directed. Make : Indoasian/ L&T/ Havells
S&F in repairs Electronic energy meter single Phase 5 to 30Amps range capacity, complete all as specified. Make : BENTEC / L&T/ABB Note :- Old unserviceable meter shall be deposited to E/M store yard.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Casing Capping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 Sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch
All as per item No. 163 here in before but for One 3 pin socket out 5 Amp on the same board
All as per item No. 163 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 163 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L in repairs for point wiring complete with 1.5 Sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor drawn through and incl surface PVC Conduit/ existing concealed conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 Sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Supreme/ Diplast/ Avon Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch.
All as per item No. 168 here in before but for One 3 pin socket out 5 Amp on the same board
All as per item No. 168 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 168 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply and Fix switch piano flush type 15 Amps 240 volts single pole one way, complete all as specified and directed.. Make : Anchor, Havells, L&T
Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply and Fix modular switch 1 way 6 Amp.1 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor
Supply and Fix modular switch 1 way 16 Amp.1 module, complete all as specified and directed.. Make :Legrand/ Crabtree/ Anchor
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor
Supply and fix LED spot light focus light fitting 9W,surface mounted,tiltable type AC 230 volts, complete all as specified and directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
Supply and fixing road lighting/ building security luminaire of watt 20 LED 2000 lumens street light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings all as specified and directed, Make : Philips Cat No BRP022 LED 20 CW MR S1 PSU GR or equivalent incrompton/Bajaj. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply and Fixing in repairs of 2 feet surface mounted battern type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white Aluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . Test Report to be submitted from any govt of India approved lab , The luminaire and driver shall be BIS approved with "R" number mentioned will submitted at time of delivery . 5 year Company warrenty certificate to be submitted at the time of delivery , complete all as specified and directed. Make : Make : Philips/ Bajaj / CG/Havells..
M&L for wiring for circuit complete submain wiring with 2 X1.5 Sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 Sqmm single core wire PVC insulated, unsheathed FRLS 1100V grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size , complete all as specified and directed. Note :- Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F as in repair PVC casing capping medium grade of size 25 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Bajaj / Philips / Wipro.
S&F as in repair PVC casing capping medium grade of size 32 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Bajaj / Philips / Wipro.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 10 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 10 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 10 Sqmm cable along with one run of 10 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one all as directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM will be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xvii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
Supply and Fixing in repairs of 4 feet surface mounted battern type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white Aluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . Test Report to be submitted from any govt of India approved lab , The luminaire and driver shall be BIS approved with "R" number mentioned will submitted at time of delivery,. 5 year Company warrenty certificate to be submitted at the time of delivery, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
Supply and Fixing in repairs of 1 feet surface mounted batten type luminaire , lumen output of 500 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operanting voltage range from 140V-270V. The luminaire shall have a white Alluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . Test Report to be submitted from any govt of India approved lab , The luminaire and driver shall be BIS approved with "R" number mentioned will submitted at time of delivery . 5 year Company warrenty certificate to be submitted at the time of delivery and complete all as directed Make : Make : Philips/ Bajaj / CG/Havells.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
S&F in repairs 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro.
S&F in repair of new PVC conduit medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast
S&F in repair of new PVC conduit medium grade of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast
S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1, complete all as specified and directed.. Make : Havells/ L&T/ Indoasian
Supply and fixed in repairs Sheet metal enclosure with distribution board TPN 415 Volts 8 ways Double door with suitable bus bar for provn for MCBs/ Isolators, fixed to wall and making all connections , complete all as specified and directed. Make: Havells/ Indoasian/Legrand
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thromoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one no of 16 A 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 300 A current carrying capacity of Alluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and remove from site reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps, 10 KA - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps, 25 KA - 01 No. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The Contractor Shall submit the drawing for approval before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thromoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one no of 16 A 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 A current carrying capacity of Alluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and remove from site reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amps 36 KA - 01 No (Incomer). (b) On Load Change over front operated of capacity 250 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps 25 KA - 02 Nos. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps 10 KA - 02 Nos. (e) MCB SPN of 240 V of capacity 40 Amps 10 KA - 04 Nos. (f) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (g) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (h) Space for spare feeder - 01 No. Note :- (i) The Contractor Shall submit the drawing for approval before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note:- (a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
M&L in repairs Galvanised Earth strip of size 25 x 6 mm fixed on proper post insulator at the instrument end, complete all as per specified and as directed.
M/S SRI BALAJI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .