Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹19.0 L+₹91,759 (5.06%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
1 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF ADM GWALIOR
AF STATION GWALIOR
REPAIR REPLACEMENT OF LT CABLES JOINTS SERVICE CONNECTION AND OTHER CONNECTED WORKS AT AF STATION GWALIOR
2020_MES_372471_2
8953/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AF STATION GWALIOR
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE AF ADM GWALIOR
₹40,000
Yes
24 Dec 2020
2 Nov 2020
3 Dec 2020
2 Nov 2020
1 Dec 2020
17 Nov 2020
2 Nov 2020 - 12 Nov 2020
60 days
Amount
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed.
Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed by Engineer-in-Charge.
Laying only old retrieved serviceable bricks for cable protection with axis of the bricks perpendicular to the axis of the cable of any description as obtained from dismantling of the cable complete all as specified and directed by the Engineer-in-Charge.
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking down protection pipe etc all as specified and directed for the following sizes:
(a) 10 Sqmm to 25 Sqmm any core
(b) 35 Sqmm to 70 Sqmm, 3½ core
(c) 95 Sqmm to 150 Sqmm, 3½ core
(d) 185 Sqmm to 300 sqmm, 3½ core
Laying, jointing and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-.
(a) 10 Sqmm to 25 Sqmm any core
(b) 35 Sqmm to 70 Sqmm, 3½ core
(c) 95 Sqmm to 150 Sqmm, 3½ core
(d) 185 Sqmm to 300 sqmm, 3½ core
(NOTE : (i) Old retrieved cables received in serviceable condition from taking down shall be used in the work. (ii) Additional quantity of LT cable, if any required, for replacing the defective portion of cable retrieved from dismantling /taking out, shall be measerd and paid under relevent item of sch.
Supply, laying, jointing and testing XLPE/ P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-Make:-HAVELLS/ Gloster/Polycab/CCI.
(a) 16 Sqmm, 4 core
(b) 25 Sqmm, 4 core
(c) 35 Sqmm, 4 core
(d) 50 Sqmm, 3.5 core
(e) 70 Sqmm, 3.5 core
(f) 95 Sqmm, 3.5 core
(g) 120 Sqmm, 3.5 core
(h) 150 Sqmm 3.5 Core
(j) 185 Sqmm 3.5 Core
(k) 240 Sqmm 3.5 Core
(l) 300 Sqmm 3.50 Core
Disconnecting & Taking out old U/S joints and Supplying, Fixing, jointing and testing for provision of straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables all as specified and directed by the Engineer-in-Charge. (MAKE : M.SEAL/DENSON/ MAHINDRA CHEMICALS/3M,)
(a) 10 Sqmm to 16 Sqmm any core
(b) 25 Sqmm to 50 Sqmm, 3½ core
(c) 70 Sqmm to 120 Sqmm, 3½ core
(d) 150 Sqmm to 185 Sqmm, 3½ core
(e) 240 Sqmm to 300 Sqmm, 3½ core
Supply, Fabrication and fixing of mild steel work as in Cross Arm, Support, Bracing, Clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed.
S&F in replacement PVC insulated, served with inner sheathed PVC tape, weather proof, twin core stranded Aluminium conductor cable of size 6 Sqmm complete all as specified and directed. Make:-HAVELLS/ Gloster/Polycab/CCI
S&F in replacement PVC insulated, served with inner sheathed PVC tape, weather proof, twin core stranded Aluminium conductor cable of size 10 Sqmm complete all as specified and directed. Make:-HAVELLS/ Gloster/Polycab/CCI
S&F in replacement PVC insulated, served with inner sheathed PVC tape, weather proof, twin core stranded Aluminium conductor cable of size 16 Sqmm complete all as specified and directed. Make:-HAVELLS/ Gloster/Polycab/CCI
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified
M & L for 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, while concrete is green over 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) with and including to make the road surface making good as per existing surface etc complete all as specified and directed by the Engineer in Charge.
M&L for Boring of hole under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia sutable for 0.4 mpa working pressure. all as specified and directed by Engineer-in-Charge. (NOTE : Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/taxi track / apron /floors etc)
Dismantling and Taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 40 mm bore,light grade (ISI marked) as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge. (MAKE : TATA/JINDAL/TT SWASTIK)
Ditto as per item no. 18 above but GI tubing 50 mm bore.
Ditto as per item no. 18 above but GI tubing 80 mm bore.
Ditto as per item no. 18 above but GI tubing 100 mm bore.
Disconnecting existing LT over heated or burnt cable terminal at existing panel/ board/feeder pillar box etc., cutting out over heated / burnt / unserviceable and portion of cable, stretching / opening cable to suitable required length from available rings incluiding necessary excavation and earth work all as required at site etc. and fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers etc. all as directed by the Engineer-in-Charge for the following sizes of cable :-
(a) 10 Sqmm to 25 Sqmm cable of any core
(b) 35 Sqmm to 70 Sqmm cable of any core
(c) 95 Sqmm to 150 Sqmm cable of any core
(d) 185 Sqmm to 400 Sqmm cable of any core
M/s Yashika Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .