Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAccepted-Finance | ₹4.3 Cr | L1 | Accepted-Finance Responsive |
| 2 | L2₹4.3 Cr+₹3.3 L (0.77%)Rejected-Finance | ₹4.3 Cr+₹3.3 L (0.77%) | L2 | Rejected-Finance Non-Responsive |
Tender Value
Refer Docs
EMD Value
₹8.7 L
Closing Date
17 Nov 2023, 12:00 pmClosed
Executive Engineer
Office of the Executive Engineer Engineering Wing Department of Education Itanagar
Up-gradation of Work of Eklavya Model Residential School (EMRS) at Medo, Lohit District
2023_ARED_1467_1
EDN(EW)/Plg-015/2021/110
Open Tender
Civil Works
Item Rate
720 days
Medo
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
Payable To Executive
₹8.7 L
Itanagar
18 Dec 2023
7 Nov 2023
17 Nov 2023
7 Nov 2023
17 Nov 2023
7 Nov 2023
9 Nov 2023
Amount
(Sh: Boys Hostel) Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock),liftupto1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soi lin15cm layers,when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying Boulder pitching in foundation and floor as per drawing.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth
b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level.
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1: 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smoothand even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm togive a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete.
b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level.
c) Column, pillars, posts and struts etc.
d) Lintels, beams, girders, bressumers and cantilevers etc.
e) Suspended floors, roofs, landings shelves and their supports, balconies and Chajjas
f) Stairs (excluding landings) except spiral stair cases.
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. a) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basic item):. b) With float glass panes of 5.5 mm thickness.
Providing and fixing flush door shutters, decorativetype, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters a) 40 mm thick including anodized aluminum butt hinges with necessary screws.
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixingto frame with 10 mm dia bolts, nuts and wooden plugs and embedding incement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hardstone chips 40 mm nominal size).
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts andnuts or by screws. b) Ornamental grill.
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm
Providing and fixing MS Hooks and Eyes. b) 250
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. a ) M.S. tube
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete c) Size of Tile 800 x 800 mm
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
12 mm cement plaster 1 : 6 (1 cement : 6 fine sand).
6 mm cement plaster to ceiling 1 : 4 (1 cement : 4 fine sand).
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Applying one coat of cement primer of approved brand and manufacture on wall surface
Finishing walls with water proofing cement paint of approved brand and manufacture required shade on new work (three or more coats) to give an even shade.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 finesand) including shuttering complete.
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore
b) 20 mm nominal bore
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore
Providing and fixing brass stop cock of approved quality. b) 20 mm nominal bore
Providing and fixing PVC connection pipe with brass union B) 45 cm length a) 15 mm nominal bore
Painting GI pipes and fitting with two coats of anti corrosive bitumastic paint of approved qualtiy. a) 15 mm dia pipe
b) 20 mm dia pipe
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipewith specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. b) Orissa Pattern WC Pan
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). a) 750 x 20 mm size
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia
c) 50 mm dia
Add Carriage of Materials
(SH: Girls Hostel) Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock),liftupto1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soi lin15cm layers,when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying Boulder pitching in foundation and floor as per drawing.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth
b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level.
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1: 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smoothand even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm togive a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc and removal of form work for: a) Foundation, footings, bases of columns etc. and mass concrete.
b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level.
c) Column, pillars, posts and struts etc.
d) Lintels, beams, girders, bressumers and cantilevers etc.
e) Suspended floors, roofs, landings shelves and their supports, balconies and Chajjas
f) Stairs (excluding landings) except spiral stair cases.
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. a) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basic item):. b) With float glass panes of 5.5 mm thickness.
Providing and fixing flush door shutters, decorativetype, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodized aluminum butt hinges with necessary screws.
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixingto frame with 10 mm dia bolts, nuts and wooden plugs and embedding incement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hardstone chips 40 mm nominal size).
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts andnuts or by screws. b) Ornamental grill.
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm
Providing and fixing MS Hooks and Eyes. b) 250
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. a ) M.S. tube
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. c) Size of Tile 800 x 800 mm
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
12 mm cement plaster 1 : 6 (1 cement : 6 fine sand).
6 mm cement plaster to ceiling 1 : 4 (1 cement : 4 fine sand).
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Applying one coat of cement primer of approved brand and manufacture on wall surface
Finishing walls with water proofing cement paint of approved brand and manufacture required shade on new work (three or more coats) to give an even shade.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 finesand) including shuttering complete.
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore
b) 20 mm nominal bore
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore
Providing and fixing brass stop cock of approved quality. b) 20 mm nominal bore
Providing and fixing PVC connection pipe with brass union B) 45 cm length a) 15 mm nominal bore
Painting GI pipes and fitting with two coats of anti corrosive bitumastic paint of approved qualtiy. a) 15 mm dia pipe
b) 20 mm dia pipe
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipewith specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. b) Orissa Pattern WC Pan
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). a) 750 x 20 mm size
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia
c) 50 mm dia
Add Carriage of Materials
(SH: Septic Tank (4 Nos) Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth
Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : Foundation and plinth a) M 20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth an
Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design..
Providing of C.I Terminal Guard
Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW vent pipes
Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. a) 100 mm dia SW pipes
Providing and fixing sand cast iron single equal plain junction of required degree a) 100 x 100 x 100 mm
(SH: Type-III Qrtr (1 Block of 4 Units) Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock),liftupto1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soi lin15cm layers,when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1: 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smoothand even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm togive a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc and removal of form work for. a) Foundation, footings, bases of columns etc. and mass concrete.
b) Column, pillars, posts and struts etc.
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :1.1) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade SC 15)
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixingto frame with 10 mm dia bolts, nuts and wooden plugs and embedding incement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hardstone chips 40 mm nominal size).
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts andnuts or by screws. b) Ornamental grill.
Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodised aluminium butt hinges with necessary screws.
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 250 x 10 mm
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. a) MS Tube
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete a) Size of Tile 600 x 600 mm
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
Finishing walls with water proofing cement paint of approved brand and manufacture required shade on new work (three or more coats) to give an even shade.
Prividing two coats of acylic water based wall putty/wall filler of asian paint/berger/ dulux over concrete/ cement plaster/bricks walls and ceilings both internal and external after removing all he loosely adhering materials frim the wall/ ceiling/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quality of clear as specified and directed by the department.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 finesand) including shuttering complete.
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore
Providing and fixing GI pipes complete with GI fittings including trenching andrefilling etc (external work). b) 20 mm nominal bore
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore
Providing and fixing brass stop cock of approved quality a) 15 mm nominal bore
b) 20 mm nominal bore
Providing and fixing PVC connection pipe with brass union B) 45 cm length a) 15 mm nominal bore
Painting GI pipes and fitting with two coats of anti corrosive bitumastic paint of approved qualtiy. a) 15 mm dia pipe
b) 20 mm dia pipe
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality.
Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps,20 GIover flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required. a) WC pan with white plastic seat and lid.
Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600 x 450 x 150 mm
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia
Add Carriage of Materials
(SH: Type-III Qrtr (1 Block of 4 Units)) Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock),liftupto1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soi lin15cm layers,when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1: 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smoothand even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm togive a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc and removal of form work for: a) Foundation, footings, bases of columns etc. and mass concrete.
b) Column, pillars, posts and struts etc.
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :1.1) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade SC 15)
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixingto frame with 10 mm dia bolts, nuts and wooden plugs and embedding incement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hardstone chips 40 mm nominal size).
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts andnuts or by screws. b) Ornamental grill.
Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodised aluminium butt hinges with necessary screws.
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 250 x 10 mm
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. a) MS Tube
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete a) Size of Tile 600 x 600 mm
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
Finishing walls with water proofing cement paint of approved brand and manufacture required shade on new work (three or more coats) to give an even shade.
Prividing two coats of acylic water based wall putty/wall filler of asian paint/berger/ dulux over concrete/ cement plaster/bricks walls and ceilings both internal and external after removing all he loosely adhering materials frim the wall/ ceiling/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quality of clear as specified and directed by the department.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 finesand) including shuttering complete.
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore
Providing and fixing GI pipes complete with GI fittings including trenching andrefilling etc (external work). b) 20 mm nominal bore
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore
Providing and fixing brass stop cock of approved quality a) 15 mm nominal bore
b) 20 mm nominal bore
Providing and fixing PVC connection pipe with brass union B) 45 cm length a) 15 mm nominal bore
Painting GI pipes and fitting with two coats of anti corrosive bitumastic paint of approved qualtiy. a) 15 mm dia pipe
b) 20 mm dia pipe
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality.
Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps,20 GIover flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required. a) WC pan with white plastic seat and lid.
Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia
Add Carriage of Materials
(Sh: Septic Tank ( 2 Nos) Earth work in excation in foundation trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. a) Hard Soil
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations plinth
Brick work with best available local bricks in foundation and plinth in cement mortar 1 : 3 (1 cement :3 fine sand).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
12 mm cement plaster 1 : 3 (1 cement :3 fine sand).
(SH: Pump House) Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock),liftupto1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soi lin15cm layers,when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1: 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smoothand even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm togive a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete.
b) Column, pillars, posts and struts etc.
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixingto frame with 10 mm dia bolts, nuts and wooden plugs and embedding incement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hardstone chips 40 mm nominal size).
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts andnuts or by screws. b) Ornamental grill.
Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodised aluminium butt hinges with necessary screws.
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
Finishing walls with water proofing cement paint of approved brand and manufacture required shade on new work (three or more coats) to give an even shade.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Carriage Charge of Materials
(SH: Sump) Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the costof centring and shuttering.
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)
Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)
Reinforcement of RCC work including bending, binding and placing in position complete. b) TMT
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
Applying of Crystalline cementinious water proofing coat.
(SH: Bore Well) Ground water exploration(Drilling) by DTH R- 200 Rig machine with ODEX option Borewell size 5" (127 mm) and complete assembling with ERW Casing pipe of size 128 mm ID and 142 mm OD and other required lubricants, assories in the depth of approximatly 100 Mtr
Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well.
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40 mm nominal bore
M/s Parasuram Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .