Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.3 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹17.6 L+₹4.9 L (38.1%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹17.7 L+₹5.0 L (39.2%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L-3 | Rejected-Finance L-3 |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
15 Aug 2022, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR /MAINTENANCE OF STREET LIGHT FITTINGS, HIGH MAST FLOOD LIGHT FITTINGS, JUNCTION BOXES AND LT CABLES AND POLES AT AF STATION NARAINA AND REPAIR TO DG SET AND OTHER MISC E/M WORKS AT AF STN NARAINA AND BASANT NAGAR UNDER GE (AF) FARIDABAD
2022_MES_539020_1
GE (FBD)/AF-25/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) FARIDABAD
₹42,000
Yes
3 Oct 2022
18 Jul 2022
17 Aug 2022
18 Jul 2022
15 Aug 2022
1 Aug 2022
18 Jul 2022 - 25 Jul 2022
Amount
Maintenance/repair to 250 / 320 KVA Gen set installed at sub station by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as specified and directed by Eng-in-Charge. Note :-(i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of all changed/repaired parts for six months from the date of servicing/repair. SPARE PARTS FOR DG SET
Supply only Element lub oil filter Cartrige complete all as specified and directed by Eng-in-Charge.
Supply only fuel filtter Cartage complete all as specified and directed by Eng-in-Charge.
Supply only Pre Filter Assembly complete all as specified and directed by Eng-in-Charge.
Supply only seal 'O' ring complete all as specified and directed by Eng-in-Charge.
Supply only KOEL Care genuine oil complete all as specified and directed by Eng-in-Charge.
Supply only K-COOL super plus Coolent complete all as specified and directed by Eng-in-Charge.
Supply only Air Filter for 320 KVA DG Set . complete all as specified and directed by Eng-in-Charge.
Supply only distilled water. complete all as specified and directed by Eng-in-Charge.
Supply only Battery terminals. complete all as specified and directed by Eng-in-Charge.
Maintenance/repair to 100/125 KVA Gen set " Greevs" installed at sub station in Basant Nagar Officer's Mess by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as specified and directed by Eng-in-Charge. Note :- (i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of all changed/repaired parts for six months from the date of servicing/repair.
Maintenance/repair to 50/ 75 / 80 KVA Gen set " Greevs" installed at sub station in Basant Nagar Officer's Mess by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant all as required and directed. Note :- (i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of all changed/repaired parts for six months from the date of servicing/repair. SPARE PARTS FOR DG SET
Supply only Element lub oil filter Cartrige complete all as specified and directed by Eng-in-Charge.
Supply only fuel filtter Cartage complete all as specified and directed by Eng-in-Charge.
Supply only Pre Filter Assembly complete all as specified and directed by Eng-in-Charge.
Supply only seal 'O' ring Make- Kirloskar complete all as specified and directed by Eng-in-Charge.
Supply only genuine Engine oil Make- Servo/Castrole complete all as specified and directed by Eng-in-Charge.
Supply only Coolent complete all as specified and directed by Eng-in-Charge.
Supply only Air Filter for 75 KVA DG Set complete all as specified and directed by Eng-in-Charge.
Supply only distilled water.complete all as specified and directed by Eng-in-Charge.
M&L for repair of PCB suitable for 250/320 KVA DG set AMF panel complete all as specified and directed by Eng-in-Charge.
M&L for repair of AVR Unit of 250/320 KVA DG Set complete all as specified and directed by Eng-in-Charge.
M&L for Repair of Self starter of 250/320 KVA DG Set complete all as specified and directed by Eng-in-Charge.
M&L for replacement of fuel pipe of DG set connecting from inlet of the tank to dg set complete all as specified and directed by Eng-in-Charge.
S&F in repair of Digital maltifunctional power meter for AMF panel complete all as specified and directed by Eng-in-Charge.
Supply and replacement of V belt for radiator fan suitable for 320 KVA DG set as per sample complete all as specified and directed by Eng-in-Charge.
M&L for repair/replacement of battery 12 volts, 180 amh complete all as specified and directed by Eng-in-Charge.
M&L for complete oherhauling of Engine incl opening of engine head of 250 / 320 KVA DG Set carefully and Servicing of internal parts of engine, piston, lining etc and entire assembly and fixing the parts after opening all as specified and directed by Eng-in-Charge. Note :- Spare part are paid separately.
M&L for replacement of the following unserviceable parts of 320 KVA DG set as per the existing Kirloskar model of the DG set complete all as specified and directed by Eng-in-Charge. Piston
Ring set
Piston pin
CR Bearing
Head valve
Head Gas kit
Head seal
Packing kit of the engine
S&F in replacement of water pump suitable for 250/ 320 KVA DG Set all as specified and directed by Eng-in-Charge.
M&L for replacement of engine lining after complete opening of engine of 250/ 320 KVA DG Set including topup of engine oil complete all as specified and directed by Eng-in-Charge.
M&L for Repair of fuel nozzeles of 250/320 KVA DG Set all as specified and directed by Eng-in-Charge.
M&L for repair of turbocharger of 250/320 KVA DG SET complete all as specified and directed by Eng-in-Charge.
Supply and fix in replacement of Battery charger 24 V DC with digital display complete all as specified and directed by Eng-in-Charge.
M&L for Design, development, supply commissioning and testing EHCC certified ground tubular effective chemical earthing system (CPRI tested for 15 KA current capacity for LT Iine) highly anticorrosive long life electrode with and including adequate protective coating to withstand servere weather conditions in the earth pit of the standard size comprising of 40mm x 3m Long Copper rod as primary conductor and hollow copper tube of 80mm x 3m long as secondary conductor to install with suitable connecting terminal confirming of IS 3043 : 1987 specification, highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation with crystalline conductive mixture (CCM) 20 Kg per bag (3 bag per kit) minimum or sufficient quanitities required as per site complete including RCC earthing pit cover , material and labour complete all as specified and as directed by Engr in Charge.
Supply and fix in repair Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Eng-in-Charge.
Supply and fixing contactor 100 Amp 3 pole for time switch astro type/Nature switch fitted inside box complete with all electrical connection after dismantling old one complete all as specified and directed by Eng-in-Charge.
Supply and fixing contactor 63 Amp 3 pole for time switch astro type/Nature switch fitted inside box complete with all electrical connection after dismantling old one complete all as specified and directed by Eng-in-Charge.
Suply and fix in replacement of Sheet metal enclosure for MCCB 3P, one no complete all as specified and directed by Eng-in-Charge.
S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415, 4 way complete all as specified and directed by Eng-in-Charge.
Supply and fixed in repair,MCCB 400 Amp ,3 pole, adjustable type ,36 KA including under voltage/over voltage relay complete all as specified and directed by Eng-in-Charge.
M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of pole one coat of primer and two coats of silver colour paint including writing pole No on yellow colour with 30cm strip upto 1.5 Mtr height from ground levelcomplete all as specified and directed by Eng-in-Charge.
Supply and fix in replacement of Onload Changover switch 200 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed by Eng-in-Charge.
Supply and fix in replacement of Onload Changover switch 400 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosurecomplete all as specified and directed by Eng-in-Charge.
M& L for preparation of trench for cable laying of size 300mm x 450 x 10 m long including excavation, brickwork, PCC work , plastering and finishing complete all as specified and directed by Eng-in-Charge.
Supply and fixed in repair,MCCB 250 Amp ,3 pole, adjustable type ,25KA including under voltage/over voltage relay complete all as specified and directed by Eng-in-Charge.
Supply and fix steel pole tubular swaged 9 metres long complete with cast iron base plate , finialtaper plug , bolts , nuts and screws as specified type 410 SP-22 complete complete all as specified and directed by Eng-in-Charge.
M & L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for pole pedestal (PCC) including necessary form work etc complete all as specified and directed by Eng-in-Charge.
M & L cement concrete in foundation filling and mass concrete type B2 1;2;4 (40mm graded aggregate) complete all as specified and directed by Eng-in-Charge.
M & L cement concrete in foundation filling and mass concrete type B2 1:4:8 (40mm graded aggregate) complete all as specified and directed by Eng-in-Charge.
Taking down unserviceable street light fitting upto 11 mtrs /LED Street Light fitting/Flood light Fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor complete all as specified and directed by Eng-in-Charge. Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost
Refixing and reconnecting up complete LED street light/Flood light fitting after rectification of defects in wiring of the fitting in an including replacement of holders, PVC connector, ballast, ignitor, condesor and lamp and making electric connection with PVC unsheathed wire with old or new conductor with OH line or Bus bar box complete all as specified and directed by Eng-in-Charge. Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost
Supply and fixing automatic street light prewired switch using nature switch for automatic switching of street light based on lux level of nature light.THE SENSOR (NATURE SWITCH) alongwith power contactor for 25 KW 3 phase,MCB pole/wall mountable enclosure made of rust proof electric shock proof terminal proof and FR grade special moulding compound junction box confirming to IP54 with all other accessoried ie lugs cable connedtion etc complete all as specified and directed by Eng-in-Charge.
Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed by Eng-in-Charge.
S& fixing LED flood light luminarie 70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Eng-in-Charge.
S& fixing LED flood light luminarie 120 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Eng-in-Charge.
S& fixing LED flood light luminarie 200 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Eng-in-Charge.
Supply and Fixing LED street light fitting 45 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and directed by Eng-in-Charge.
Supply and Fixing LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and directed by Eng-in-Charge.
Supply and fix in replacement LED bollard fitting 9 Watt with luminaire with MS Pipe housing with glare free PMMA diffuser , IP65 of height 800 mm suitable for single phase connection 50 Hz 230 Volts complete all as specified and directed by Eng-in-Charge.
Supply and fix single phase driver for LED street light / flood light of 45 to 200 watt capacity and compatible with existing street light/ flood light any type / any rating all as specified and as directed by Engineer-in-charge
S&F in replacement street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed by Eng-in-Charge.
Supply and fix in replacement non-metallic junction box/street light box with three phase aluminium bus bar of suilable for 415 Volt , 50 Hz electric supply conforming to IP65 wall / pedestral mounted and including MCB SPN 06 Amps complete all as specified and directed by Eng-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as specified and directed by Eng-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Outdoor type complete all as specified and directed by Eng-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Outdoor type complete all as specified and directed by Eng-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Outdoor type complete all as specified and directed by Eng-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 4 core 10 sq. mm nominal cross section in service connections complete all as specified and directed by Eng-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and directed by Eng-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed by Eng-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed by Eng-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed by Eng-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed by Eng-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out complete all as specified and directed by Eng-in-Charge.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Eng-in-Charge.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Eng-in-Charge.
M & L for brick protection with sub class 'B' bricks laid dry flat over electric cable in trenches all as specified and directed by Engineer-in Charge.
M & Labour for sand cushioning with a layer of sand 80mm thick consolidated before laying of cable and 150mm thick consolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by Eng-in-Charge.
Surjit and Sons
YASHVI ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .