Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.0 L+₹10,160 (0.68%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹15.1 L+₹20,337 (1.37%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹15.4 L+₹48,715 (3.27%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹15.7 L+₹83,277 (5.60%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
10 Aug 2021, 6:00 pmClosed
GE(AF)OJHAR
GE(AF)OJHAR
Repair/Replacement and Maintenance of Internal wiring in SMQ and OMQ area at AF Stn Deolali
2021_MES_450188_3
8765/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Deolali
As per tender
8 documents required · 8 mandatory
₹500
GE(AF)OJHAR
₹44,000
Yes
21 Aug 2021
2 Aug 2021
12 Aug 2021
2 Aug 2021
10 Aug 2021
5 Aug 2021
2 Aug 2021 - 4 Aug 2021
Amount
Taking down carefully aluminium/copper point wiring (light,fan,socket power etc) on TW batten/PVC casing capping, surface steel/PVC conduit excluding all fitting/fixtures and making good disturbed surfaces of wall/floor/ceiling etc to match the adjoining surfaces all as directed.
M&L for point wiring complete with two single core, PVC insulated, unsheathed, multi stranded bright annealed copper conductor cable, 1.5 Sq.mm 1100 Volts, FR grade drawn through and including heavy duty PVC casing and capping not less than 25 mm width and accessories surface mounted on walls, ceilings etc. on & including PVC box and plate for mounting switches, sockets, regulators etc and one run of 1.5 Sq.mm PVC insulated, unsheathed, multistranded, copper conductor cable FR grade as earth wire and connected to common earth dully complete for the following :-
One light/fan point controlled by one switch
One 3 pin socket out let 5 Amps on same board.
One 3 pin socket out let 5 Amps on independent board.
One bell point controlled by one bell push
All as per Sl item No. 02 above but with two runs of 2.5 Sq.mm cable and one run of 1.5 Sq.mm cable as earth wire for one 3 pin socket outlet/power point 15 Amps controlled by one switch.
S&F in repairs Switch piano flush type single pole one way 5 Amp
S&F in repairs switch piano flush type single pole one way 15 Amp
S&F in repairs Bell push flush type 5 Amps.
S&F in repairs Bell, Ding Dong AC 230 Volts single pole.
S&F in repairs Bell multi music type AC 230 Volts single pole.
S&F in repairs Socket out let 2 in 1, 5 pin 5 Amps flush type.
S&F in repairs Socket out let 2in1,3 pin 5 and 15 Amps flush type.
S&F in repairs Lamp holder PVC/polycarbonate insulated body with back plate suitable for batten fittings.
S&F in repairs Ceiling rose surface type, PVC/Polycarbonate isulated body size 50x28 mm two to three terminals.
S&F in repairs Fan regulator electronic 5step type 2 module sitable for 1200/1400mm sweep.
S&F in repairs Fan regulator electronic step type 5 step 1 module suitable for 1200/1400 mm sweep.
S&F in repairs PVC rectangular board 100mm x 100 mmx 50mm deep. Make : Presto Teak/Modi/pressfit
S&F in repairs PVC rectangular board 175mm x 100mmx50mm deep. Make : Presto Teak./pressfit
S&F in repairs PVC rectangular board 200mmx150mmx50mm deep. Make : Presto Plast./pressfit
S&F in repairs PVC rectangular board 250mmx200mmx50mm deep. Make : Presto Teak./pressfit
S&F in repairs PVC rectangular board 350mmx300mmx50mm deep. Make : Presto Teak./pressfit
Dismantling and taking down U/S main switches/ MCBs/DBs enclosures /electric meter etc and keeping in safe custody either for reuse or for disposal including making good to the disturbed surfaces of wall complete all as specified and as directed by Engr-In-charge.
Material and labour for fixing with all necessary connections of the following items :-
MCB SP 5 to 30 Amps 240 volts. B series 10 KA
MCB SPN 5 to 30 Amps 240 volts. B series 10 KA
MCB SPN 40 to 63 Amps 240 volts. B series 10 KA
MCB TPN 32 to 63 Amps 415 volts. B series 10 KA
Sheet metal enclosure for DB’s with bus bar, MCB SPN 2 way ,240 volts single doorwith detachable gland plate.
Sheet metal enclosure for DB’s with bus bar ,MCB SPN 4 way ,240 volts double door with detachable gland plate.
Sheet metal enclosure for DB’s with bus bar , MCB SPN 8 way ,240 volts double door with detachable gland plate.
Sheet metal enclosure for DB’s with bus bar ,MCB SPN 12 way ,240 volts double door with detachable gland plate.
Sheet metal enclosure for DB’s MCB TPN, bus bar , 4 way ,415 volts double door with detachable gland plate.
Sheet metal enclosure for DB’s MCB TPN, bus bar , 4 way ,415 volts double door with detachable gland plate, vertical type.
S&F sheet metal enclosures Distribution board 415 volt, Vertical TPN 8 way with provision for DPx160 series MCCB of legrand make or equivalent in L&T as incomer and SP/TP MCB's as outgoing as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mountingIP-43 IK-09 protection with the following :- (i) MCCB DPx160 series thermal magnetic, 25 KA rupturing capacity,125A, 4 pole as incomer - 01 No. (ii) MCB SP 6 to 32 Amp,10 KA - 19 Nos (iii) MCB TP 10-30 Amp,10KA - 03 Nos.
S & F in repairs and connecting up LED light fittings 1x18/20 watt 4 feet long complete with LED rode 18/20 watt, spring loaded rotary holder, connector etc. complete and connecting up with and including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Crompton fitting DMLN1LT8-16, 1X18/20W and LED rode LT8-20-865-2 or equivalent in Philips/Bajaj/Havells/Wipro ).
S & F in repairs and connecting up LED light fittings 1x9/10 watt 2 feet long complete with inbuilt LED driver and connecting up with and including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Crompton fitting LCTL-9_CDL, 1X9/10W or equivalent in Philips/Bajaj/Havells/Wipro ).
S&F in repairs LED bulk head fittings 1 x 10 W including all necessary electric connection Make: crompton Model No:LBHE-10-CDL or equivalent in Bajaj/ phillips/ wipro/Havells.
S&F in repairs PVC casing capping 25 mm wide fixed on wall/ ceiling for encasing of existing point wiring/ sub main wiring with and including all fittings and fixures complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC casing capping 32 mm wide fixed on wall/ ceiling for encasing of existing point wiring/ sub main wiring with and including all fittings and fixures complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Sub main wiring with PVC insulated un armoured heavy duty copper conductor 1100 Volts FR grade 2 single core 2.5Sq.mm cable and one run of 1.5Sqmm copper earth wire for continuous earth fixed on wall/ceiling/floor etc. drawn in PVC casing capping/ PVC non metallic conduit complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Sub main wiring with PVC insulated un armoured heavy duty copper conductor 1100 Volts FR grade 2 single core 6 Sq.mm cable and one run of 4 Sqmm copper earth wire for continuous earth fixed on wall/ceiling/floor etc. drawn in PVC casing capping / PVC non metallic conduit complete all as directed.
S&F in repairs Sub main wiring with PVC insulated un armoured heavy duty copper conductor 1100 Volts FR grade 2 single core 4 Sq.mm cable and one run of 2.5 Sqmm copper earth wire for continuous earth fixed on wall/ceiling/floor etc. drawn in PVC casing capping / PVC non metallic conduit complete all as directed.
S&F in repairs LED corridor light fittings 1 x 10 W including all necessary electric connection Make: crompton Model No:LBHP-10-CDL or equivalent in Bajaj/ phillips/ wipro/Havells.
S&F in repairs electronic driver of wattage 9W for LED fitting after disconnecting the fitting carefully from electric supply as specified and directed by Engr-in-charge.
S&F in repairs electronic driver of wattage 18W for LED fitting after disconnecting the fitting carefully from electric supply as specified and directed by Engr-in-charge.
Disconnect and insulate electric supply wire and taking down carefully ceiling/ exhaust/cabin/wall fan of any make and sweep dismantling blades, check for repairs required including replacement of flexible PVC insulated copper conductor of size 0.75 sqmm 3 core and rubber bushes ( Note: Repairs/ Replacement of spares shall be carried under appropriate items)
Hanging only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed from ceiling rose to fan connector and testing as directed and specified (Note: The fan shall be fitted with new set of clamps, rubber shackle split pins and top and bottom nut bolts etc.)
Hanging/fixing only exhaust/cabin/wall fan of any make or sweep connecting up complete with and including provision of copper conductor cord 3 core PVC insulated and sheathed from celing rose to fan connector & testing as directed and specified. (Note: The fan shall be fitted with new set of washers, nuts, rubber packing etc.)
Opening of any type of fan for checking the bearing, bushes and carrying out maintenance such as greasing, oiling and reassembling complete or for rewinding, but including scrapping the old existing paint and painting with two coats of synthetic enamel paint over one coat of red oxide primer, painting the MES No. replacement of flexible cord size 23/0.0076, and rubber bushes etc all as specified and directed by Engineer-in-Charge.
(a) celing fan 1200 mm sweep
(b) Exhaust fan 300/380/450mm sweep
Opening up of fan motor of fan, cleaning stator,rotor, cleaning of all parts greasing oiling of bushes and bearing reassembling and testing for smooth functioning all as directed by Engr in charge
(a) celing fan 1200 mm sweep
(b) Exhaust fan 300/380/450mm sweep
M & L for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc complete all as specified and directed by Engineer-in-Charge for
(a) Ceiling fan 1200 mm sweep
(b) Exhaust fan 300mm sweep
(c ) Exhaust fan 375 mm sweep
Labour charges for machine work enlargement of bushing housing to house bearing 6201 in place of bushing in modification for longer services.
S&F fan clamp assembly consisting of nut, bolts, washers and split pin alongwith suitable size rubber real for mounting of fan down rod.
S&F insulated copper flexible conductor 3 core 1 sqmm.
S&F capacitor for ceiling fan of 2.5 MFD. Make: Usha/EPCOS/Priya.
S&F ball bearing of size 6201 suitable for fans
S&F ball bearing of size 6202 suitable for fans
S&F louvers & shutters complete for exhaust fan of size 300 mm sweep.
S&F in repairs ceiling light fittings 36W LED energy saving, environmental friendly long life and accessories fixed false ceiling 60 cm x 60 cm in size including connection with PVC copper 1.5 sqmm 3 core cable etc complete all as directed. Make crompton Model No LCTLRN-36-CDL or equivalent in Phillips, Havells, Wipro, Bajaj as approved by GE
Taking down and dismantling unserviceable solar water heater carefully, opening complete, replacement of worn out parts, rectify the damage or leakage, if any, cleaning the solar component and making it serviceable and refixing the same including rectifying minor water supply problems there after necessary testing complete all as directed ( Note:- Rate shall be including of all other minor spares required for smooth functioning of solar water heater. Geyser element, thermostat & flexible wire PVC insulated will be measured and paid seperately.)
Supply only heating element triangular base or as per sample for geyser of 2 KW capacity
S&F in repairs thermostat switch for water heater 40 degree centigrade to 90 degree centigrade all as per directed by Engr in charge.
M R ENTERPRISES
MAHIMA CONSTRUCTION
Sona Lakshmi Associate and Developers
Paras Electricals
shubham Enterprises
Veer Brothers
SHRI SULAI ELECTRICALS
LOKMANYA ENTERPRISES
M/s.NIKI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .