Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTANCE | |
| 2 | L2₹26.8 L+₹1.8 L (7.21%)Rejected-Finance 5 45 10A PALACE ENCLAVE ARAMANE BAGILU ROAD NEAR VENKATRAMANA TEMPLE DAKSHINA KANNADA KARNATAKA 574227 INDIA | DAKSHINA KANNADA | KARNATAKA | 574227 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹28.9 L+₹3.9 L (15.7%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in eligible category |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
26 Feb 2024, 6:00 pmClosed
COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
COMPREHENSIVE REPAIR MAINTENANCE OF LIFTS AT HQ KNA NSRY NOM MESS AND PATANJALI UNDER GE(SB) KARWAR
2024_MES_639564_1
85745/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
CWE NAVY VASCO
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE (SB) KARWAR
₹60,000
Yes
16 May 2024
29 Jan 2024
28 Feb 2024
29 Jan 2024
26 Feb 2024
12 Feb 2024
Amount
M&L for Comprehensive Maintenance/ repair and Servicing of One 8 Passenger Capacity Lift (compatible make for existing lift) with 3 Landings ( G+2) floors installed at NSRY Bldg , Naval Base complete all as specified and as directed.
M&L for Comprehensive Maintenance/ repair and Servicing of One Goods Lift of 1500 Kg capacity (compatible make for existing lift) with 3 Landings(G+2 ) floors installed at NSRY Building at Naval Base complete all as specified and as directed.
M&L for Comprehensive Maintenance and Servicing of Two Nos 8 Passenger capacity Lift (compatible make for existing lift) with 7 landings (G+6) floors, Lift No. 1 and 2, installed at HQ KNA, Naval Base complete all as specified and as directed.
M&L for Comprehensive Maintenance and Servicing of Four Nos 26 Passenger capacity Lift (compatible make for existing lift) with 4 Landings ( G+ 3) floors Lift No. 1, 2, 3 and 4, installed at INHS Patanjali all as specified and as directed
M&L for Comprehensive Maintenance and Servicing of One 8 Passenger Lift (compatible make for existing lift) with 2 Landings ( G+1) floors installed at NOM Building at Naval Base complete all as specified and as directed
M&L for Comprehensive Maintenance and Servicing of One No Goods Lift of 2000 kg capacity (make: Kone or compatible make for existing lift)with 2 Landings ( G+1) floors installed at Cool & Cold room building at BV Yard, complete all as specified and as directed
(e) Interlocks on hoistway Door, Hoistway Door Hangar, Car door, safety shoes, load weighting equipment, Car frame, car safety, guide shoe, magnet tray, lift roller, belt for doors, carriage, contact, fixing bracket, skate Mechanical and Platform. (f) Check for any of damage Internal wiring connection of controllers, lift panel and ARD to lift machine, Cop wiring, Lop wiring ventilation fan, LED lights and lift display. (g) Replacement of DC Brake coil, brake liner as per existing if required. (h) Reapir/Replacement of LED lights in car cabin, floor reed sensor if required. (k) Resistance Testing of earthing system. (v) Complaint/ breakdown will be attended/rectified within maximum 3 to 4 hours after informing the complaint by the undersigned or his authorised rep, otherwise penalty of 2000/- will be levied as penalty. (vi) The detailed lift mechanics of the firm shall report to the Concerned JE at the Lift complaint cell for receiving the complaints at round the clock daily including sunday and holiday.
S&F in replacement Car Operating Panel with push button box along with all connected accessories complete as per existing suitable for 8 Passanger Lifts (G+1, G+2 & G+6) installed at NSRY, HQ KNA and NOM complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the car operating panel all as specified and as directed.
S&F in replacement Car Operating Panel with push box along with all connected accessories complete as per existing suitable for 26 Passanger Lifts (G+3) installed at Patanjali complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the car operating panel all as specified and as directed.
S&F in replacement Car Operating Panel with push box along with all connected accessories complete as per existing suitable for 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY and BVY complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the car operating panel all as specified and as directed.
S&F in replacement Overload sensor as per existing suitable for 8 Passanger Lifts (G+1, G+2 & G+6) installed at NSRY, HQ KNA and NOM complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the overload sensor all as specified and as directed.
S&F in replacement Overload sensor as per existing suitable for 26 Passanger Lifts (G+3) installed at Patanjali complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the overload sensor all as specified and as directed.
S&F in replacement Overload sensor as per existing suitable for 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY and BVY complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the overload sensor all as specified and directed.
S&F in replacement Full Height Infra Red Door Beam Sensor as per existing suitable for 8 Passanger Lift (G+1, G+2 & G+6) installed at NSRY, HQ KNA and NOM complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the full height infra red door beam sensor all as specified nad directed.
S&F in replacement Full Height Infra Red Door Beam Sensor as per existing suitable for 26 Passanger Lift (G+3) installed at Patanjali complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the full height infra red door beam sensor all as specified nad directed.
S&F in replacement Full Height Infra Red Door Beam Sensor as per existing suitable for 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY and BVY complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the full height infra red door beam sensor all as specified nad directed.
M&L required for complete overhauling of Machine unit of 26 passenger capacity lift comprising of replacement of gear bearing, motor bushings , machine oil seal kit, 220 V DC break coil suitable for of 15 Hp motor , including proper greasing of bearings , replacement of old unserviceable nut and bolts, including placing of safety cover to machine unit pully and movable parts etc. complete all as specified and directed. Note: The above rated quoted including the guard to be provided for safety of moving part as directed by Engr-in-charge.
M&L required for complete overhauling of Machine unit of 8 passenger capacity lift comprising of replacement of gear bearing, motor bushings , machine oil seal kit, 220 V DC break coil suitable for 7.5/10 Hp motor , including proper greasing of bearings , replacement of old unserviceable nut and bolts, including placing of safety cover to machine unit pully and movable parts etc. all as specified and directed. Note: The above rated quoted including the guard to be provided for safety of moving part as directed by Engr-in-charge.
S&F in replacement of machine Encoder all as specified and directed
Supply and Fixing in replacement of maintainance free batteries of capacity 12 Volts, 18Ah suitable for automatic rescue device of lift motor of cap 15 HP complete alongwith newbattery lead of copper conductor of 10 Sqmm cross-sectional area, multistranded, single core, PVC insulated fitted with lugs/ terminals at one end and brass terminals at other end, complete all as specified and as directed. Note: The battery lead replaced shall have colour as per colour coding complete all as specified & directed.
Supply & Fixing in replacement of cabin fan suitable for lift of Make: Omega having sweep 300mm , min speed 2200 RPM, Air delivery 60CMM and min power 75W with rotatig grille and overload thermal protector complete all as specified and as directed.. Note:- Make conforming to cat part No 250523 of model Ultima cabina of
S&F in repair announciator system panel as per existing suitable for 8 Passanger Lift (G+2 & G+6), 26 Passanger Lift (G+3), 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lift (G+2) installed at NSRY, HQ KNA, NOM, BVY and Patanjali complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the announciator system panel all as specified and as directed.
Taking down unserviceable steel wire rope and supply and fix new main steel wire rope of 10 mm/12mm dia ungalvanised 8/19 construction including necessary connection all as specified and directed. Note: The make of the rope should conform to current IS standars and test certificate in respect of the rope to be produced complete all as specified & directed.
Taking down unserviceable steel Governor rope and supply and fix new governor rope of 8 mm dia ungalvanised 8/19 construction including necessary connection all as specified and directed. Note: The make of the rope should conform to current IS standars and test certificate in respect of the rope to be produced complete all as specified & directed.
S&F in replacement VF3 Drive upto 15 HP capacity control panel as per existing suitable for 8 Passanger Lift (G+2 & G+6), 26 Passanger Lift (G+3), 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lift (G+2) installed at NSRY, HQ KNA, NOM, BVY and Patanjali complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the VF3 drive all as specified and as directed.
Supply and Fixing in replacement of Automatic Rescue Device having capacity 96 Volts and suitable for lift motor of capacity 15 HP, upto 25 Amps, 960 RPM, 440 Volts AC supply as incomer, conforming to recent IS standards suitable for 8 passanger capacity lift of G+2- 03 installed at NSRY landing and 8 passanger capacity lift G+1 - 02 landing, installed at NOM of Make: Omega, complete all as specified and as directed. Note: The above quoted rate includes the control wiring required for the connection of new ARD alongwith batteries with the main drive assembly of the lift, testing of the ARD system after installation complete all as specified & directed.
Supply and Fixing in replacement of Automatic Rescue Device having capacity 96 Volts and suitable for lift motor of capacity 15 HP, upto 25 Amps, 960 RPM, 440 Volts AC supply as incomer, conforming to recent IS standards suitable for 8 passanger capacity lift, G+6- 07 landings installed at HQ KNA of Make: Omega, complete all as specified and as directed. Note: The above quoted rate includes the control wiring required for the connection of new ARD alongwith batteries with the main drive assembly of the lift, testing of the ARD system after installation complete all as specified & directed.
Supply and Fixing in replacement of Automatic Rescue Device having capacity 96 Volts and suitable for lift motor of capacity 15 HP, upto 25 Amps, 960 RPM, 440 Volts AC supply as incomer, conforming to recent IS standards suitable for 26 passanger capacity lift , G+2- 03 landings installed at Patanjali of Make: Omega, complete all as specified and as directed. Note: The above quoted rate includes the control wiring required for the connection of new ARD alongwith batteries with the main drive assembly of the lift, testing of the ARD system after installation.
Supply and Fixing in replacement of Automatic Rescue Device having capacity 96 Volts and suitable for lift motor of capacity 15 HP, upto 25 Amps, 960 RPM, 440 Volts AC supply as incomer, conforming to recent IS standards suitable for 2000 Kg of G+1-02 Landing at BVY and 1500 Kg Goods Lift, G+2- 03 landings installed at NSRY of Make: Omega, complete all as specified and as directed. Note: The above quoted rate includes the control wiring required for the connection of new ARD alongwith batteries with the main drive assembly of the lift, testing of the ARD system after installation.
S&F in replacement Landing Operating panel with card, LOP box, wiring along with all connected accessories complete as per existing suitable for 8 Passanger capacity Lifts (G+1, G+2 & G+6) and 26 Passanger capacity Lifts (G+3) installed at NSRY, HQ KNA, NOM, and Patanjali complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the Landing Operating panel all as specified and directed.
S&F in replacement Landing Operating panel with card, LOP box, wiring along with all connected accessories complete as per existing suitable for 2000 Kg capacity Goods Lift (G+1) and 1500 Kg capacity Goods Lifts (G+2) installed at NSRY & BVY complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the Landing Operating panel all as specified and directed.
S&F in replacement of shaft information system with junction Box suitable for 8/26 Passanger Lift and 1500 Kg/2000 Kg Goods Lift installed at various location complete all as specified and directed
S&F in replacement of Travelling Cable as per existing core and size suitable for 8 Passanger Lifts (G+1 & G+2), 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY, NOM and BVY complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the Travelling Cable all as specified and directed.
S&F in replacement of Travelling Cable as per existing core and size suitable for 8 Passanger Lifts (G+6), 26 Passanger Lifts (G+3) installed at HQ KNA and Patanjali complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the Travelling Cable all as specified and directed.
S&F in replacement of Door Drive as per existing suitable for 8 Passanger capacity Lifts (G+1, G+2 & G+6) installed at NSRY, HQ KNA, NOM complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the door drive all as specified and directed.
S&F in replacement of Door Drive as per existing suitable for 26 Passanger capacity Lifts (G+3) installed at Patanjali complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the door drive all as specified and as directed.
S&F in replacement of Door Drive as per existing suitable for 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY and BVY complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the door drive all as specified and directed.
S&F in replacement of Cast Iron Multi Groove Dirverter Pulley as per existing suitable for 8 Passanger Lifts (G+1, G+2 & G+6) installed at NSRY, HQ KNA and NOM complete all as specified and directed
S&F in replacement of Cast Iron Multi Groove Dirverter Pulley as per existing suitable for 26 Passanger Lifts (G+3), 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY, BVY and Patanjali complete all as specified and directed
S&F in replacement of 4 Core x 6 Sqmm flexible copper cable as per existing suitable for motor of 8 Passanger Lifts (G+2 & G+6), 26 Passanger Lifts (G+3), 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY, HQ KNA, NOM, BVY and Patanjali complete all as specified and directed.
S&F in replacement Header as per existing suitable for Car and Landing Doors of 8 Passanger Lifts (G+1, G+2 & G+6) installed at NSRY, HQ KNA, NOM, BVY and Patanjali complete all as specified and directed
S&F in replacement Header as per existing suitable for Car and Landing Doors of 26 Passanger Lifts (G+3), installed at Patanjali complete all as specified and directed
S&F in replacement Header as per existing suitable for Car and Landing Doors of 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY and BVY complete all as specified and directed
S&F in replacement Over Speed Governer as per existing type suitable for capacity of 8 Passanger Lifts (G+1, G+2 & G+6) installed at NSRY, HQ KNA and NOM complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the Over Speed Governer all as specified and directed.
S&F in replacement Over Speed Governer as per existing type suitable for capacity of 26 Passanger Lifts (G+3) installed at Patanjali complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the Over Speed Governer all as specified and directed.
S&F in replacement Over Speed Governer as per existing type suitable for capacity of 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY and BVY complete all as specified and directed. Note: The above quoted rate includes the installing and testing of the Over Speed Governer all as specified and directed.
Supply and fix in replacement of 9/10 watt bulkhead light for lift car movable area including commissioning of the same all as specified and directed by Engr-in-Charge.
Dismantling and taking out 15 HP motor from lift Control room and refixing the same in original position after rewinding of burnt winding with original gauge of super enamel copper wire replacing the worn out parts including varnishing, heating and packing of following capacity all as specified and directed.
Dismantling and taking out 7.5/10 HP motor from lift Control room and refixing the same in original position after rewinding of burnt winding with original gauge of super enamel copper wire replacing the worn out parts including varnishing, heating and packing of following capacity all as specified and directed.
Dismantling and taking out Door drive motor for doors and refixing the same in original position after rewinding of burnt winding with original gauge of super enamel copper wire replacing the worn out parts including varnishing, heating and packing of following capacity all as specified and directed.
Dismantling and taking out ventilation exhaust from control panel room and refixing the same in original position after rewinding of burnt winding with original gauge of super enamel copper wire replacing the worn out parts including varnishing, heating and packing of following capacity all as specified and directed.
Dismantling and taking down old unsv cable and supply and fix in replacement of 2.5 Sqmm PVC round flexible copper cable as per existing size for motor/car light panel/bulk head light all as specified and directed.
Supply and fix new in replacement of rating 4 Pole RCCB, 63 amp, 300mA capacity as per existing for lift panel including commissioning of the same all as specified and directed by Engr-in-Charge.
Supply and fix new in replacement of rating 3 Ph, 415 V, 4 pole MCB C 32-63 amp capacity for lift panel including commissioning of the same all as specified and directed by Engr-in-Charge.
Supply and fix in repairs three pole power contactor of 9 to 40 amps with AC coil voltage 110 volts all as specified and as directed.
Supply & fix in repairs automatic controlling limit switch metal enclosure 1NO/1NC type suitable for lift all as specified and as directed
S&F in replacement of Landing Door with Header and frame as per existing suitable for capacity of 8 Passanger Lifts (G+1, G+2 & G+6) installed at NSRY, HQ KNA and NOM complete all as specified and directed
S&F in replacement of Landing Door with Header and frame as per existing suitable for capacity of 26 Passanger Lifts (G+3) installed at Patanjali complete all as specified and directed
S&F in replacement of Landing Door with Header and frame as per existing suitable for capacity of 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY and BVY complete all as specified and directed
S&F in replacement of Car Door with Header as per existing suitable for capacity of 8 Passanger Lifts (G+1, G+2 & G+6), 26 Passanger Lifts (G+3) installed at NSRY, HQ KNA, NOM, and Patanjali complete all as specified and directed
S&F in replacement of Car Door with Header as per existing suitable for capacity of 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lifts (G+2) installed at NSRY and BVY complete all as specified and directed
S&F in replacement of uninterrupted power supply (UPS) system 0.6 KVA - 1KVA, capacity for minimum 120 minutes backup for intercom systems power backup, Sinewave form ouput, 230 Volt ,50Hz, Power factor>0.9, should take care of 100% load transfer without break, IP 20 protection incl battery bank and necessary electrical connections complete all as specified and as directed.
Supply and fix in repairs DC electromagnetic brake of double acting type, 110 V DC Voltage, 95 Ohms resistance rating and F class insulation type as per existing make suitable for 7.5 HP/10HP capacity lift motor including all connected accessories complete all as specified and directed.
Material and Labour for fixing of Mirror 4 mm thick inside the car cabin including all acessories for passenger/goods lifts complete all as specified and as directed
M & L for lay GI strip of size 32x6 mm from test point to lift machine room to be terminated to the control panel, machine and other equipment installed in machine room incl all fixing accessories, proper porcelin/PVC plugs on wall complete all as specified and directed by Engineer- in- charge
Supply & fixing in replacement of copper wire 4.0 mm and necessary clamps, shaddels, screws complete from machine room equipment to junction point/loop point/earth pit including taking down of old one complete all as specified and as directed
Supply & fixing in replacement of GI wire 4.0 mm and necessary clamps, shaddels, screws complete from machine room equipment to junction point/loop point/earth pit including taking down of old one complete all as specified and as directed
M & L for painting on lift cabin ( 08/13 passenger lift) mild steel surfaces after proper covering of COP,handrails,mirrors display board etc including lift landing door/car door preparation of old steel surface of cabin girth and applying two coat of synthetic enamel paint( Ist grade quality) by spray painting including making good all distrubed surface of lift cabin of 08/13 Passenger Lift complete all as specified and as directed.
M & L for painting on lift cabin ( 26 passenger/Goods Lift) mild steel surfaces after proper covering of COP,handrails,mirrors display board etc including lift landing door/car door preparation of old steel surface of cabin girth and applying two coat of synthetic enamel paint (Ist grade quality) by spray painting including making good all distrubed surface of lift cabin of 26 Passenger/Goods Lift complete all as specified and as directed.
Material & Labour in replacement for earthing with galvanized steel earth plate electrode of size 60cmx60cmx6mm thick bured directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanized earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel using GI or steel strip 32X6mm dia as earthing lead as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40 mm dia GI light grade earth lead protection pipe and pre-cast earth pit cover 80mm thick made of RCC (1:1:5:3) type A1 duly reinforced with 8mm dia TMT bar @ 100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs, etc, mest, charcoal and common salt in alternate layer of 15cm thick including taking down old unserviceable earth plate complete all as specified & directed by Engr-in-Charge.
Taking down and supply & fixing in replacement of new OSG Pit wheel / Sheave as per existing suitable for capacity of 8 Passanger Lift (G+2 & G+6), 26 Passanger Lift (G+3), 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lift (G+2) installed at NSRY, HQ KNA, NOM, BVY and Patanjali complete all as specified and directed
Material and Labour for painting of motor (capacity of 7.5HP to 15 HP) with gear assembly complete including Lift control panel, Speed governer, ISMB installed in machine room of lift installation with two coats synthetic enamelled sky blue/ grey paint also where black paint is required and write the SM No on motor and panel with superior quality of synthetic enamelled white paint after scratching the old paint and preparing smooth surface suitable for painting complete all as specified and as directed
Removing and refixing of lift car counter weight and alignment of rails in shaft wall properly grouting in rich concrete mix and large size fasteners with chemical bolt for fixing the fastener brackets (recommended product- Hill and fisher make) for 8 Passanger Lifts (G+2 & G+6), 26 Passanger Lift (G+3), 2000 Kg Goods Lift (G+1) and 1500 Kg Goods Lift (G+2) installed at NSRY, HQ KNA, NOM, BVY and Patanjali complete all as specified and directed
S&F in replacement LOP display card with fixing stud suitable for 1500 Kg/2000 Kg Goods lift complete all as specified and directed.
S&F in repair PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core complete all as specified and directed.
Dismantling and taking out unserviceable blower type lift cabin ventilation fan and supply & fixing in replacement of new blower type cabin fan of existing size and capacity as directed.
ICARE LIFTS PRIVATE LIMITED
JAI SHREE GOPAL ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .