Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.4 L+₹1.7 L (8.67%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹38,600
Closing Date
15 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
PROVN OF 01 RCC WATCH TOWER AT KANDRORI AND CERTAIN MINOR AND REVENUE WORKS AT KANDRORI AND DAMTAL UNDER GE SOUTH PATHANKOT
2020_MES_370118_1
GES/PKT/T-35/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
All contractors enlisted with MES in Class E and above and
category a i b i
8 documents required · 8 mandatory
₹500
Yes
GE (SOUTH) PATHANKOT
₹38,600
Yes
24 Nov 2020
18 Aug 2020
17 Sept 2020
18 Aug 2020
15 Sept 2020
1 Sept 2020
60 days
Amount
Excavation in trenches, n. exc.1.5m wide and n.exc. 1.5m deep; for foundation etc n.exc.10 Sqm on plan and getting out in any type of soil.
Returning filling incl spreding leveling watering and well ramming in layout n. exc. 25cm in any type of soil.
Removing excavated material n. exc.50mtr and depositing where directed at a level n. exc. 1.5m above the starting point all as specified.
M&L PCC 1:4;8 type D-2 (using 40mm graded aggregate) in foundation, filling and mass concrete.
M&L RCC(Nominal mix M-25) in roof Beams, cantilevers,bressummers, lintels over 1.5m span
M&L RCC(Nominal mix M-25) in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like
M&L mild steel bars TMT 8mm dia and over cut to length bend to shape ,binding with 0.9mm dia annealed wire.
Ditto but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders
M&L Formwork to Rough finished concrete surfaces flat sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M&L Formwork to Rough finished concrete surfaces square sides of pillars,posts, struts, piers, columns and stanchions
M&L Formwork to Rough finished concrete surfaces flat sides and soffits of roof beams, lintels, cantilever shelves for rough finished flat surfaces of concrete etc
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete etc
M&L Formwork to Rough finished concrete surfaces staircases with sloping or stepped soffits including risers and stringers
M&L Brickwork with old size sub class fly ash, straight or curved on plan exc 6m mean radius, built in CM 1:4.
M&L 15mm th rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finishing the surfaces even and smooth without using extra cement.
M&L 15mm th rendering on other than fair faces of brick work or concrete surfaces in CM 1:4 and finishing the surfaces even and smooth without using extra cement.
M&L 10mm th rendering on concrete surfaces of ceiling in CM 1:3 and finishing the surfaces even and smooth without using extra cement.
M&L preparation of plastered surfaces of walls and applying two coats of cement base paint on new surfaces.
M&L preparation of plastered surfaces of walls and applying two coats of white wash on new surfaces.
M&L preparing of newly plastered surfaces and applying three coats of white wash on ceiling
M&L 75 mm thick cement concrete 1:4:8 type D-2 (using 40mm graded agg) finished even and fair.
M&L Non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed bed in CM 1:6 complete
M&L coloured Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over cement plaster 10mm thick in CM 1:4 all as specified.
M&L for 75mm thick cement concrete type C1 ,1:3:6 (using 20mm graded aggregates) finished even and smooth without using extra cement as in flooring ,plinth protection etc,
S&F steel window/ ventilator made of MS tubular frame with double shutter (glazed & wire guage) made out of Z section using flash butt welding hinges shall be provided to both shutters including guard bars and all fittings as per Drg No CEPZ/TD/245/01 sheet 1/2 .
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing as per SSR Pt-II 2010
S&F factory made solid PVC moulded door shutter with particle board core 28 to30mm thick(stiles) with 2 4 or 6 panels design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face supplying and fixing in frame at site asper specifications and drawings as per SSR Pt-II 2010
M&L, 3 mm thick sheet glass ordinary qualityand glazing with oil putty in square n.exc 0.50 sqm in each pane
S&F galvanised MS wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanised wire staples.
S&F butt hinges med weight cold rolled MS, size 100 mm.
S&F 150mm long Mild steel barrel tower bolt stove enamelled black with bright bolt .
S&F 150 mm long Mild steel pressed handle oval type stove enamelled black .
M&L for two coats of synthetic enamel paint on new steel surfaces of any description not otherwise described over 10 cm width or girth all as specified.
M&L tube med grade with fittings and fixed complete to walls or laid in floors,bore of pipe 20 mm,
M&L tube med grade with fittings and fixed complete to walls and ceilings or laid in floors,bore of pipe 15mm,
S&F 15mm bore Cast copper alloy Bib taps, with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule fixed in repair complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank (cylindriacal vertical with closed top) hoisted and fixed in position all as specified in SSR part-I of capacity 500ltrs
S&F 20mm dia ball brass valve high pressure assy with rod and PVC ball complete
Cutting and screwing existing steel tubing of 20mm dia for alterations or additions without taking down
S&F PVC Floor trap with grating suitable for 75 mm dia outlet and jointing to waste pipe in cement concrete type B1 (1:2:4) complete all as specified.
-ditto- but pillar taps CP 15mm bore.
PVC connections 15mm size with PTMT nuts of length 450mm
S&F vitreous china wash hand basin white flat back of size 630x450 mm ,including brackets complete all as specified and directed.
S&F vitreous china wash down water closet pan (Orissa patern) white with integral foot rest of of size 580x440mm incl provn of lime core bedding.
S&F low level 10 ltrs capacity PVC valveless symphonic action type flusing cistern incl flush pipe fixed with inlet valve,float,brackets,PVC connection complete all as specified .
M&L for 150 mm thick cement concretebed to drain pipe type D-2 ,1:4:8 (using 20mm graded aggregates) incl cradles etc,
S&F, for 150 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors.
Hard core of gauge n.exc 63mm deposited spread and leveled in layers n.exc 15cm thick watered and rammed to a true surface
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc ., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete (FE-410 Gde E-250, Qlty 'A')
Preparing the new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide all as specified.
S&F mild steel framed work such as grills/guard bar/railing, gratings using square/round bar with with ends of bars shoulders/welded drilling holes for fixing of guard bars all as specified.
S&F Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade , with grey cement and no pigment all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces mixed with water proofing compound @ 4% weight of cement, finish fair and even without using extra cement all as directed by Engr-in-Charge
M&L RCC(Design mix M-30) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L RCC(Design mix M-30) in Columns, pillars, piers,posts and struts
M&L RCC(Design mix M-30) in roof Beams, cantilevers,bressummers, lintels over 1.5m span
M&L RCC(Design mix M-30) in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like
M&L RCC(Design mix M-30) in Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), all as specified.
Supply and fix 4 Pole MCCB 12 to 63 Amp, 50 Hz, 415 V AC with rupturing capacity 25 KA in sheet steel enclosure made out of CRCA sheet duly powder coated of thickness 2mm with IP- 43 and LED indication lamps complete all as specified and directed by Engineer-in-Charge.
Supply & Fix sheet metal enclosure with DB's ( grouted in walls) double door type for MCB's 04 ways with 200 Amps 240 volts rated bus bar IP-54,IK-09 all as specified and as directed. Note : (i) DB shall be minimum IP-54 with mechanical strength IK-09 and manufacturer/OEM certificate for the same to be submitted. (ii) The quoted rate inclusive of cutting of cement concrete/brick wall and making good the disturbed surfaces complete.(v) Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment”
M&L 6 to 32 Amps MCB SP ( ISI Marked) 50 C/S 10 KA 'C' sereis complete all as specified.
S&F MCB 6 to 32 Amp SPN 50 C/S 10 KA 'C' sereis complete all as specified all as directed
M & L for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 4 sqmm and one single core FRLS PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet after completion of wiring to be submitted before claiming payment.
Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) Driver Efficacy – more than 85% ( constrant current driver).(ii)Driver Type – Potted (iii) THD - < 10% (iv)Led Driver Current – less than 750 mA(v) Efficacy of Led Fixtrue – 100 lm/watt ( minimum) (vi) Efficacy of Led Chip – more than 130 lm/watt( Vii) Surge Protection – 4 KV & above as per IEC standard inbuilt in Driver and External SPD 5KV (vii) Working Humidity - 10% to 90% RH (ix) Led Make – Nichia/Philips Lumiled/ Cree /Osram/ Seoul (x) Life – 50,000 hours at 70% lumens(xi) CRI – more than 70 (xii) Lens – Each Led shall be of High Power ( 1 to 3 watt only) with mandatory modular lens. (xiii) Working Temp – 0 to 50 degree C. (xiv) Heat Sink – Pressure die cast aluminium (xv) Junciton Temp – 100 degree C (xvi) Body of Fitting – Pressue Die Cast with company logo / make engraved or embossed in housing LM 6 Grade.(xvii) Impact code – Min IK05 or more (xviii) LM79 report from NABL /UL accredited lab. (xix) LM80 report from Led Manufacturer.(xx) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixtrue.(xxi) MS Clamp fittings with nut bolts and GI bracket, junction box included in the rate.(xxii) Test certificates to be submitted before commencement of work/ claiming for payment .(xxiii) Warranty certificate for minimum 2 years to be submitted from OEM.
Supply , lay, connect, test and commission cable LT 1100 volts heavy duty XLPE insulated armoured aluminium conductors, in trenches/ducts on angle iron supports including glanding, crimping and connecting up complete all as specified and of size 3.5 Core x 35 sqmm.(Note: Earth work to be measured and piad seperately.)
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed .
Earthing complete with galvanised GI earth plate electrode of size 600x600x6.00mm burried directly in ground (earth pit not less than 2.25mtr below normal ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected to galvanised earth lead wire 8.00mm dia by means bolt, nuts, check nuts and washer made of galvanised iron or steel including earth work in any type of soil, charcoal dust and salt layers15cm all around the earth plate as shown in electrical plate No 03 of SSR Part I 2009, 20mm dia GI watering pipe medium grade with funel and wire mesh, GI protection piple light grade 15mm dia from earth pit to main board including PCC pit in PCC 1:3:6 type B2 using 20mm graded stone aggregate, angle iron frame of size 40x40x3mm with hold fast embeded in PCC, RCC pit cover with suitable handle and earth work, removal of surplus soil all as required at site or directed.
M&L for point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge (Phase Neutral and earth wire shall be provided in standard colour code R,Y,B for phase, Black for neutral green for earth wire). Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet after completion of wiring to be submitted before claiming payment.(e) In ceiling Portion surface conduit wiring shall be carried out.
One light point or one fan point or bell point controlled by one switch SP one way 230 Volts.
One 3 pin socket out let 5/6 Amps on same board.
All as per item No 1 above but with 2.5 sqmm cable insulated for 3 pin 15 amp multipurpose outlet including 1.5 sqmm PVC insulated copper wire for earth continuity on independent board complete.
M&L for switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body.
M&L for Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body.
M&L for socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body.
S & F of Lamp holder insulated body with back plate for batten fittings.with polycarbonate body.
M & L for LED lamp 9 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
M&L for ceiling rose surface bakelite 2 to 3 terminals with polycarbonate body.
Supply & Fix sheet metal enclosure with DB's ( grouted in walls) double door type for MCB's 04 ways with 200 Amps 240 volts rated bus bar IP-43,IK-08 all as specified and as directed. Note : (i) DB shall be minimum IP-43 with mechanical strength IK-08 and manufacturer/OEM certificate for the same to be submitted. (ii) The quoted rate inclusive of cutting of cement concrete/brick wall and making good the disturbed surfaces complete.(v) Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment”
M & L for LED tube light fitting 20 watt energy efficient complete with 4 feet long channel type made out of CRCA sheet powder coated complete with housing with all accessories prewired and making connection with 3 core copper flexible cable of size 0.75 Sqmm from ceiling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note : (i) Minimum 2 years guarantee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 5 KV to be provided in addition to inbuilt. (iii) Power factor more than 0.9 (iv) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.(v) Luminous efficiency shall not be less than 95 lumens/ watt”
Supply & Ventilation fan AC sinlge phase 230/240 volts of size 225 mm sweep having plastic body with louvre including connecting to ceiling rose all as required or directed including connecting to ceiling rose all as required or directed.Note: Test report and Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment.
Supplying and fixing service cable size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as spd and directed.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
Mahajan Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .