| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.2 LAccepted-AOC 12 MANAULI HOUSE AMBALA CITY 134003 HRY | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹55.2 L Quoted ₹55.9 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹59.5 LRejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹59.5 L | L2 | Rejected-Finance 2nd Lowest |
| 3 | Rejected-Technical 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | - | - | Rejected-Technical Rejected due to your firm not having desired category as per NIT. |
| Sl No | Description | Qty | Unit | PARAMOUNT INDUSTRIES L1 | M/S Sonu Traders L2 |
|---|---|---|---|---|---|
| 1.00 | Servicing and checking of EXISITING 11 KV Breakers any make and type make VCB with blower, cleaning of existing HT panel inside, outside with tighting of all bus bar, nut & bolt, alignment, adjustment of gaps between phase to phase as per manufacturer recommended, Checking and tightening of control wiring circuit as charging motor closing coil and tripping coil circuit, Manually tripping testing of VCB, Cleaning, removal of dust and dirt to male/Female contacts, greasing & lubrication all moving fixed part including replacement of minor parts such as spring, washers etc. for smooth mechanical operation etc. complete with testing commissioning as required. Servicing, Calibration, testing of ( one earth fault one over current) with secondary injection testing of 11 KV /VCB, Operational testing through relay front pad as well as push button, Testing/ Calibration of safety relays through secondary injection kit, Tripping testing of VCB through over current and earth fault relay,testing and servicing of the existing 11 kV VCB panel, including Contact Resistance Measurement (CRM) and submission of test certificates with proper sealing. Primary injection testing to verify tripping functionality. Opening of HT panel, removal of moisture from busbars, insulators, HT cable box, and heating of P.T. and C.T. chambers. Relay settings to be checked and configured as per the protection scheme. During breaker racking, inspection of jaw-type male/female contacts connected to the busbar is included—cleaning or replacement shall be done if found carbonized or damaged. Final insulation resistance (megger) testing of all components to be completed as per standard procedures and safety norms. Note : Minor spare part should incl in qouted rates for making functional & major spare may be pay separety as mentioned below. | 15 | Each Job | 31,500 ₹4.7 L | 30,000 ₹4.5 L |
| 2.00 | M&L for calibration of HT VCB indoor type 11 KV & 33kV CR Panel VCB with calibration of all protective devices or relay according to load, minor repair to wiring connector block etc all as specified and directed. Note:- (i) Calibration is to be done by auth service person. | 30 | Each | 7,020 ₹2.1 L | 10,000 ₹3 L |
| 3.00 | Dismantling of old u/s MFM of any make and type and replacement with AC Power MFM for 3 phase power supply Input Voltage Max continuous input voltage 125% of nominal value Technical Specs VA Burden Nominal input voltage burden < 0.4 W approx. Nominal input current burden < 0.1 W approx. Auxiliary Supply burden < 6 VA approx Accuracy Reference Conditions 23°C +/- 2°C Voltage ±0.5% of Nominal value (±20 to ±120%) Current ±0.5% of Nominal value (±5 to ±120%) Power ±0.5% of Nominal value (±5 to ±120%) Energy Class 1.0 Temperature Drift 0.05%/°C Input Current Display Type 1 line 8-digit LED Display Display Height 9 mm Overload Indication -oL- (Above 126% of nominal value) Display Range Voltage 0 to ±9999 Current 0 to ±9999 Power 0 to ±9999 Energy (Import & Export) 0 to 99999999 Shunt Setting Range 50 ~ 150 mV No of Channels 1 Current Sensor External Shunt Full Scale Setting Range 1 A to 20 kA Max continuous input current 125% of nominal value 61 ~ 200 VDC Nominal Input Voltage Range 10 ~ 60 VDC 201 ~ 1000 VDC Auxiliary Supply Operating Measuring Range Voltage ±5 to ±125% of nominal value Current ±0.2 to ±125% of nominal value Nominal Value 230 V AC-DC, 50/60 Hz for Higher Aux Higher Aux 60 V – 300 V AC-DC, 45 to 65 Hz range Uncertainty ±2 minutes / month (23°C +/- 2°C) Real Time Clock (RTC) Lower Aux 20 V – 60 V AC-DC 24 V AC-DC for Lower Aux 3 92mm+0.8 Panel Cutout 92mm+0.8 Dimensions Details96mm Overload Withstand 2 x rated value for 1 second, repeated 10 times at 10 second intervals Overload Withstand 20x rated value for 1 second, repeated 5 times at 5 min intervals NOTE: Variation due to influence Quantity is 100% of class index built with Data Logging User Selectable parameters (1 to 30) can be logged at regular intervals (1 to 60 min) with Date & Time stamp in internal memory and can be | 20 | Each | 81,900 ₹16.4 L | 79,000 ₹15.8 L |
| 3.01accessed via Modbus l Max Records can vary from 8532 to 91010 depending upon number of selected parameters Load Analysis Logging of Energy consumed and Peak Demand (Power & Current) in a day and in a month for tracking of load behaviour l Daily Data is available for last 1 year and Monthly Data is available for last 02 years Direct Remote Access (optional) l Remote configuration of the Instrument and access of measured parameters via MODBUS l Programmable baud rates up to 57.6kbps 1 - line 8 digit Ultra-bright LED Display l 1 - line LED display provides easily readable data on meter front with a display range of 99999999 Reverse Locking l Energy and Ampere Hour accumulation can be blocked for Reverse Power and Current resp l Reverse condition can be set as Import or Export Onsite Configuration can be done via Front Keys, USB Serial Interface or RS485 (MODBUS) Relay Functions l Limit Switch - For protection against over-shoot or undershoot of any selected parameter. Note :- Contractor has to submit post audit report of work from approved auditor, without that completion will not be issued. | |||||
| 4.00 | Dismantling of old u/s buzzer of any make type and replacement with 96 mm Buzzer of input Voltage: 80-140V Ac/Dc(Or) 60-280V Ac/Dc Input Supply: 220V Ac/Dc 110V Ac/Dc handling capacity 80 volts to 180 volts DC with Burden less than 15mA at nominal input Audio Output : 100dBA +/- 5% Panel Cut out size : 92mm x 92mm Overall dimension : 96mm x 96mm x 60mm of tones : Three tone (Site selectable)Make ALAN/MINILEC | 15 | Each | 6,300 ₹94,500 | 10,000 ₹1.5 L |
| 5.00 | Dismantling of old pully system and mercury / thermal based sensors and protection and supply, fixing testing & commissioning with Micro controller-based indicator with inbuilt Temperature measurement in single enclosure. Incorporates highly stable built-in or Remote Temp. sensor. 3 Digit, 0.56" bright LED display for displaying RH & Temperature. Process parameter Hi and Low status indication for channel.along with Tubular space heater suitable for connection to the single phase AC supply in each panel (both control and relay panel in case of duplex type) complete with switches and thermostat located at convenient position shall be provided at the bottom side of the cubicle to prevent condensation of moisture. The watt loss per unit surface temperature of the heater shall be low enough to keep surface temperature well below allowable heat. The wattage of the heater shall be such as to keep 10° C above average ambient temperature in the rainy season but the temperature shall not under any circumstances damage the insulation of the wiring of the panel.User selectable set limits for process value violation. Inbuilt buzzer to audible process value violation. Password protection for calibration and programming mode. Software Calibration for 2 channels. etc. Programmable devise address, baud rate, (max no. of device is 1-256). Remote programmable from master device. User programmable offset correction. Compact, All Stainless-Steel enclosure with 35 mm depth for installation in prefab panels. Brick and modular wall mounting and flush mounting. Inputs two numbers temp & RH, Temperature input integral or remote optional, Humidity input integral or remote optional, transmitting power supply – 220/24/5 V DC 100 MA WITTH ISOLATION BASED SMPS TYPE, Indication Temperatures, Channel-1: 3 digit Seven segments 0.56” RED display. Channel-2: 3 digit Seven | 15 | Each | 14,400 ₹2.2 L | 15,000 ₹2.3 L |
| 5.01segments 0.56” RED display. 5-LEDs for visual alarms, buzzer for audible alarm, LED for 485-comm. Control action PID control with auto tuning , ON - OFF control(For RH: ON-OFF control only) Proportional band (P) 1.0 to 400.0°C Functional specifications Humidity Temperature 3 digit LED display RH Sensor input Sensor enclosed with unit ON-OFF control 7A SPDT Relay output 0% - 100% Humidity control range 3 digit LED display RTD Input (PT100) ON-OFF / PID control Auto tune / Self tune PID 7A SPDT Relay output Temperature unit °C / °F selectable 0 to 99.9 min 0 to 999 sec Integral time (I) Derivative time (D) 0.1 to 99.9 sec 0.1 to 99.9°C Cycle time Hysteresis width 95% RH Temperature Humidity (non - condensing) Environment specifications Operating : 0°C to 50°C; Storage : -20°C to 75°C Supply voltage 90 to 270V AC / DC (AC : 50 / 60 ) Auxiliary supply specifications Power consumption 4 VA max @ 230V AC Mounting Panel Weight Mechanical specifications Cable length 1 meter Dimensions (mm) Sensor Information 52 x 28.8 x 18 Manual reset value -19.9°C to 19.9°C. Note :- Contractor has to submit post audit report of work from approved auditor, without that completion will not be issued. | |||||
| 6.00 | Dismantling of old & replacement with new T&C breaker control switch contact 2NO/2NC CURRENT HANDLING NOT LESS THAN 25 AMP to control the circuit breaker. The switch must be two pole, three throw switch with one common connection. It has a handle on top and a keyway (slot) on the side for locking purposes. Switch must be installed used to manually break and make connections in the circuit breaker. This could be useful for maintenance or troubleshooting purposes. | 4 | Each | 9,900 ₹39,600 | 15,000 ₹60,000 |
| 7.00 | Dismantling of old burnt contacts & supply,installing, testing & commissioning of Main contacts shall have ample area and contact pressure for carrying the rated continuous and short time currents of the existing 11 kV breaker without excessive temperature rise which may cause pitting or welding with Main contacts shall be the first to open and the last to close so that there will be little contact burning and wear with rated current 1600 Amp impulse stand voltage with heat proof metal having electrolytic copper. | 8 | Each | 18,900 ₹1.5 L | 15,000 ₹1.2 L |
| 8.00 | Dismantling of old damaged unserviceable motors of any type make & supply,installing, testing & commissioning spring charging mechanism complete job with necessary control wiring of Permanent magnet AC/DC motor with built-in gear box for use in Spring Charging suitable for existing Make VCB heavy duty type power with output speed as desired with unidirectional clutch is incorporated in the gear box to enable driving in one direction, but the load cannot back-drive the motor with Dc rectifier assembly complete to sustain load including necessary micro switch & Automation with help of 110 Volts DC switching 3 NO/NC potential free contact of load capacity not less than 10 Amp for auto On/Off command & control having Supply voltage 220 volts DC , power 300 watts, reduction ratio 292.75:1, gear box offset/ parallel insulation class B speed 1000-2000 RPM. | 2 | Each | 72,000 ₹1.4 L | 95,000 ₹1.9 L |
Updated dates
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
17 Nov 2025, 6:00 pmClosed
HQ CWE MEERUT
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
REPAIR/MAINT OF HT VCBs AND ALLIED WKS AT MRS AND SUB STATION AT NORTH AREA AND BHAGAT LINE AREA UNDER AGE E/M (ES) AT GE (U) MEERUT CANTT
2025_MES_734888_1
94276/MRT/2025-26/E8
Open Tender
Civil Works
120 days
MEERUT CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (U) MEERUT
₹1.1 L
Yes
8 Jan 2026
13 Oct 2025
21 Nov 2025
13 Oct 2025
17 Nov 2025
3 Nov 2025
Amount
Servicing and checking of EXISITING 11 KV Breakers any make and type make VCB with blower, cleaning of existing HT panel inside, outside with tighting of all bus bar, nut & bolt, alignment, adjustment of gaps between phase to phase as per manufacturer recommended, Checking and tightening of control wiring circuit as charging motor closing coil and tripping coil circuit, Manually tripping testing of VCB, Cleaning, removal of dust and dirt to male/Female contacts, greasing & lubrication all moving fixed part including replacement of minor parts such as spring, washers etc. for smooth mechanical operation etc. complete with testing commissioning as required. Servicing, Calibration, testing of ( one earth fault one over current) with secondary injection testing of 11 KV /VCB, Operational testing through relay front pad as well as push button, Testing/ Calibration of safety relays through secondary injection kit, Tripping testing of VCB through over current and earth fault relay,testing and servicing of the existing 11 kV VCB panel, including Contact Resistance Measurement (CRM) and submission of test certificates with proper sealing. Primary injection testing to verify tripping functionality. Opening of HT panel, removal of moisture from busbars, insulators, HT cable box, and heating of P.T. and C.T. chambers. Relay settings to be checked and configured as per the protection scheme. During breaker racking, inspection of jaw-type male/female contacts connected to the busbar is included—cleaning or replacement shall be done if found carbonized or damaged. Final insulation resistance (megger) testing of all components to be completed as per standard procedures and safety norms. Note : Minor spare part should incl in qouted rates for making functional & major spare may be pay separety as mentioned below.
M&L for calibration of HT VCB indoor type 11 KV & 33kV CR Panel VCB with calibration of all protective devices or relay according to load, minor repair to wiring connector block etc all as specified and directed. Note:- (i) Calibration is to be done by auth service person.
Dismantling of old & replacement with new T&C breaker control switch contact 2NO/2NC CURRENT HANDLING NOT LESS THAN 25 AMP to control the circuit breaker. The switch must be two pole, three throw switch with one common connection. It has a handle on top and a keyway (slot) on the side for locking purposes. Switch must be installed used to manually break and make connections in the circuit breaker. This could be useful for maintenance or troubleshooting purposes.
Dismantling of old burnt contacts & supply,installing, testing & commissioning of Main contacts shall have ample area and contact pressure for carrying the rated continuous and short time currents of the existing 11 kV breaker without excessive temperature rise which may cause pitting or welding with Main contacts shall be the first to open and the last to close so that there will be little contact burning and wear with rated current 1600 Amp impulse stand voltage with heat proof metal having electrolytic copper.
Dismantling of old damaged unserviceable motors of any type make & supply,installing, testing & commissioning spring charging mechanism complete job with necessary control wiring of Permanent magnet AC/DC motor with built-in gear box for use in Spring Charging suitable for existing Make VCB heavy duty type power with output speed as desired with unidirectional clutch is incorporated in the gear box to enable driving in one direction, but the load cannot back-drive the motor with Dc rectifier assembly complete to sustain load including necessary micro switch & Automation with help of 110 Volts DC switching 3 NO/NC potential free contact of load capacity not less than 10 Amp for auto On/Off command & control having Supply voltage 220 volts DC , power 300 watts, reduction ratio 292.75:1, gear box offset/ parallel insulation class B speed 1000-2000 RPM.
Dismantling of old damaged mechanism & supply,installing, testing & commissioning of four position racking mechanism for a circuit breaker in a cubicle or housing providing Connected, Test, Disconnect and Out positions with following specifications Racking lead screw is mounted in the circuit breaker structure in its own support, rear end of the racking screw is threaded to engage and move a travelling nut which rides in guide slots. The outer ends of the travelling nut engage a pair of connecting links which rotate a pivoted roller bracket. The roller bracket carries a racking roller which engages a cam slot in a member extending from the rear portion of the cubicle or housing. The shape of the cam slot plus the increasing lever arm of the connecting links around the pivot pin on the nut provide a variable racking force which is needed for primary disconnect contact engagement. The central positioning of the racking mechanism makes it suitable for existing 11 kV of circuit breaker. racking mechanism must be interlocked with the closing mechanism; releasable locking means and interlock means are provided to limit the operation of the racking mechanism to conditions which are safe for the operator; thus, the unlocking of the racking mechanism after the breaker is tripped will hold the trip mechanism and hold it trip free as long as the racking mechanism is unlocked. An indexing element for the slide for the locking mechanism is provided for all the positions of the circuit breaker.
real-time anomaly detection Technical details Real-time KW, KVA, KVAR, phase-wise, consumption KWh, KWh, KVarh, KVAh, PF, phase-wise PF, Hz, I, Ig, In, VLL (phase wise), VLN (phase wise), Vn, Vg, harmonics, voltage and current unbalance User Interface The cloud-based facility management system should enable controlling substations and facilities. The system should support adding more parameters in future with minimal changes. AF should have a mechanism to proactively know when some equipment is not giving data / has errors without coming to site. User interface should be remotely accessible on internet, with secure login credentials. User interface should work on secure https. Communication between data gathering, and data storage should be over a secure encrypted channel. IIOT controller must have inbuild local control capability to operate in case of network unavailability. However, control logics must be configurable remotely. The user-interface should have minimum of following tabs (all dashboards, reports must be self-configurable without any scripting or OEM intervention): Dashboard - To evaluate captured parameters at a glance with current, hourly, daily, weekly, monthly, & yearly. End-user should be able to create Dashboards on their own, without AF involvement. End user should be able to define number of rows / columns in dashboard, merge cells of dashboard to make some areas small / large, configure row heights to provide flexibility in how data is displayed (ex. multiple numerical KPIs in a smaller row, and
Sum, averaged values over day, week, month) system should support creating user-defined benchmarks, and displaying data in charts / dashboard comparing against these benchmarks System should support saving frequently used analytics charts for later users. All saved charts should be available to choose with a single-click. System should support showing analytics data in graphical and tabular form. Facility to export data over a custom time interval to Excel shall be available. Reports should be user-defined and not fixed (hardcoded into the system). System should support sending daily, weekly and monthly reports. Daily reports should be sent next day morning over email incorporating all data from previous day. There should be a mechanism to turn reporting sending of scheduled reports ON/OFF There should be a mechanism to send a pre-created report on-demand (and not just as scheduled daily / weekly / monthly report) Settings - To view the metadata related to the system, such as the site name and installation date, details of equipment at site etc. Alarms and event logs – Alarm should Issue a system update that the system has detected. Passwords should be stored in encrypted format. Website should be accessible on all platforms and be compatible with popular browsers such as IE, Chrome, Firefox, Safari etc. Online Administration: All administration is handled online via a current web browser Audit Trail: Administrators can access logs in the backend on need-basis where they can view changes that have been made to the database for critical information. Data Backup should support PITR (Point-in-time-recovery). Scheduler for auto archival and backup of application and database to a different machine which should be capable of coming online by simply firing a
script button in event of downtime of primary server. The database should use encryption at rest to persist the data in database. Secure password protected login for administrative actions in the system. All updates to data gathering hardware should be through OTA (over the air). No static IPs shall be made available at sites. The complete equipment must be programmed with protection CT inside the existing Low Tension switchgear /breaker / Switching Contactors along with multifunction microprocessor digital programmer having Main measurements and functions include: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values Power Factor per phase and total Frequency of measured voltage value HIGH LOW AVERAGE - - value functions for all measurements Maximum demand of power and current values Voltage and current asymmetry Total harmonic distortion ( ): voltage and current THD Energy meters for active, reactive, apparent partial and total values, per phase and system values Hour counter for programmable total and partial hours Phase active power unbalance must saturate sufficiently high to allow a relatively accurate measurement of the fault current by the protection whose operating threshold can be very high. with built in high Accuracy Limit Factor (ALF) ratio between the nominal overcurrent and the rated current. so that existing switchgear relay must be able to withstand high overcurrent’s also featured with Real accuracy factor ratio between the overcurrent , nominal error and the rated current .with following specifications insulation level voltage .433 KV ratio 100/5A - to
500/5A Core 3 class PS, KPV >= 150 Volts Imag at vk/2<= 30 ma , RCT at 75C<= 2 Ohms short time rating 15 KA for 1 second approved by GE minimum ISO 9001:2015 Certified Note :- The Entire work at site is to be executed only by OEM approved by GE. Original OEM is entitled for work . Contractor has to ensure it.Necessary test certificates to be approved by Engg-in-Charge first before execution at site. Approved by GE. Note :- Contractor has to submit post audit report of work from approved auditor, without that completion will not be issued.
M&L for cleaning and tightening of nuts and bolts of electrical equipment in 33kV switchyard, including replacement of unserviceable nuts, bolts, and associated spare parts as required. Work also includes replacement or welding of damaged components wherever necessary. High-quality greasing gel shall be applied to all post/disc insulators, lightning arresters (LA), current transformers (CT), potential transformers (PT), isolators, breakers, and transformer incoming and outgoing terminals, including all movable parts and joint locations. All materials such as nuts, bolts, greasing gel, and welding consumables are deemed to be included in the item rate. The entire job shall be executed at 33kV switchyard locations including MRS Bhagat Line, Shivaji Line, and RR area, all as specified and directed by the Engineer-in-Charge.
M&L for supplying, assembling, and fixing insulator sets suitable for 33,000 volts operation, comprising the following: (a) Disc Type Insulator Assembly: Three-disc assembly of porcelain, vitreous finish in brown, white, or green colour, each disc having a height of 145mm and diameter of 225mm, conforming to IS:1445. The discs shall be of ball and socket type suitable for tension application and shall be installed complete with suitable tension clamps for the conductor. The entire disc assembly shall be capable of operating safely under a working pressure of 33,000 volts. The work includes carefully taking down and removing the old unserviceable disc insulators and assembling and erecting the new insulator set as directed by the Engineer-in-Charge. (b) Pin Type Insulator: M&L for supplying and fixing of HT porcelain insulators, pin type, vitreous finish in white or green colour, suitable for 33,000 volts grade, including one galvanized mild steel spindle, two galvanized iron washers, and one galvanized iron nut. The insulators shall conform to relevant IS standards and be suitable for outdoor installation under high voltage transmission conditions. The work includes taking down and removing old unserviceable pin type insulators and installing the new ones as specified and directed. All materials and workmanship shall comply with relevant IS specifications, and installation shall be carried out to the satisfaction of the Engineer-in-Charge. The rates quoted shall include all handling, transportation, erection, and dismantling works, complete in all respects.
Taking down old, unserviceable lightning arrester carefully without damage to adjacent structures and transporting it to the designated yard as directed. Supply and fix (S&F) new lightning arrester, expulsion type, complete with all standard fittings and accessories suitable for 33,000 V system, transmission class, with a discharge capacity of 65 kA. The lightning arrester shall be installed in place of the existing unit of the same rating, ensuring compatibility and functionality. All work shall be carried out as specified and as directed by the Engineer-in-Charge, including testing and commissioning for proper operation.
Maintenance Free Earthling with retains the Moisture for very long time, ensuring quick dissipation of Faults, Short Circuits and Lightning Current. With Corrosion Resistant, Eco Friendly and Highly Conductive. To be installed indoor or outdoor and in almost all soil conditions. with The conductive compound in and around the Electrode creates a conductive zone which provides a greater surface area for Peak Current dissipation with minimum Long and Reliable average life of 05 year systematic pipe earthling system designed in accordance to IS: 3043 (1987) consist of copper bonded electrode 76mm x 3 metre along with 50 kg pro earth high enhancing compound along with necessary GI strip up to 10 meter from test point to concerned LT Panel /Tfr as directed by engineer in charge High Tensile Strength, Low Carbon steel core having terminal with four holes for connection with electrolytic coating of copper deposits having metallurgical bond between the core and the copper. Featuring never cracks or bended. Boring rates and complete tasking rates are included The standard copper thickness is 0.25 mm. The copper bonded grouup electrodes have a high resistance
to corrosion and provides a low resistance path to ground. With earthling material DARK GREY SWELLING VOLUME 28ML/1000ML DISPERSION RATE HIGH pH 8-9 MOISTURE CONTENT 10-11% 50 kg in each earth Homogenous Mixture of naturally occurring highly conductive element compounds that enhances the effectiveness of the earthling to a great extent especially in the area of poor conductivity to be placed around the earth electrode in the pit to improve the conductivity of earth electrode and ground conduct area. Each earth must have hygroscopic in nature thereby retaining moisture around earth electrode during dry seasons. It is nontoxic, non-explosive, non-reactive, noncorrosive, and thermally stable and swells considerably. Earth Pit Chambers are made of Heavy Duty Polyethylene/Polyplastic material.
M/S Sonu Traders (BID ID -3474400)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TD1.pdf
Tender Documents • 0.41 MB
TD2.pdf
Tender Documents • 0.23 MB
TD3.pdf
Tender Documents • 0.24 MB
TD4.pdf
Tender Documents • 0.79 MB
BOQ_822896.xls
BOQ • 3.45 MB
Download all tender documents and submit your bid