Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC OLD PULL MADIYA JAIRAMPUR AZAMGARH AZAMGARH UTTAR PRADESH 276001 | AZAMGARH | UTTAR PRADESH | 276001 | L1 | Accepted-AOC DUE TO LOWEST BID | |
| 2 | L2₹24.4 L+₹2.4 L (11.1%)Rejected-Finance | L2 | Rejected-Finance DUE TO HIGHER BID | |
| 3 | L3₹24.9 L+₹2.9 L (13.3%)Rejected-Finance | L3 | Rejected-Finance DUE TO HIGHER BID | |
| 4 | L4₹25.6 L+₹3.7 L (16.7%)Rejected-Finance | L4 | Rejected-Finance DUE TO HIGHER BID | |
| 5 | L5₹26.6 L+₹4.6 L (21.0%)Rejected-Finance | L5 | Rejected-Finance DUE TO HIGHER BID |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Oct 2022, 6:00 pmClosed
GE (WEST) FEROZEPUR CANTT
GE (WEST) FEROZEPUR CANTT
REPAIR TO PUMPING SET PANEL BOARD DG SET AND RELATED WORKS OF SEWAGE INSTALLATION IN THE AREA OF WEST OF JHOKE ROAD UNDER GE (WEST) FEROZEPUR CANTT
2022_MES_524088_1
802022/GE-52/E8
Open Tender
Civil Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) FEROZEPUR CANTT
₹50,000
Yes
14 Nov 2022
5 Oct 2022
27 Oct 2022
5 Oct 2022
25 Oct 2022
19 Oct 2022
Amount
Dismantling of defective centrifugal sewage motor complete of capacity 7.5 HP-10 HP by removing cable connection from LT panel and taking out carefully from sewage sump well and inspect the same, transporting to repair workshop for repair. Reassembling after repair and testing, transporting back to sewage well re-installation by connecting electric cable to LT panel and testing complete all as specified and directed. Note :-(i) The cost also includes for making stand by arragnment to avoid any type of breakdown by putting standby motor/pumpset all as directed by Engr-in-charge. (ii)Minor Items costing up to RS 300/- i.e gland packing, Nuts bolts , insulation tape, Rubber seal, Hozing bushes etc required are deemed to be included in unit rate of above item. (iii) spares parts required for repair will be measured and paid under relevent item of Sch 'A' as supply only. (iv) Labour required for dismantling the defective pump set for removing of defective spare parts and re-assembling after fixing new spares are deemed to be included in unit rate of above item. (v) Cont.will send daily his rep to E/M yard for getting complaint, after getting complaint contracter will rectified bottleneck with in 24 Hrs if fail for any reason,a fine of Rs 1500/- per day
Supply only deep groove ball bearing suitable for 7.5 to 10 HP Motor complete all as specified and directed.
Supply only PVC fan complete suitable for 7.5 to 10 HP motor complete all as specified and directed.
Supply only rotor with shaft complete suitable for 7.5 to 10 HP motor complete all as specified and directed.
Supply only coupling set complete suitable for 7.5 to 10 HP motor complete all as specified and directed.
M&L for rewinding of centrifugal electric motor cap 7.5-10 HP with super enameled copper winding wire make HTP/Devi Dyal of same size/ gauge as existing after providing 'F' class insulation material and varnishing complete all as specified. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
All as per item No 1.00 here in before but for capacity 15 HPpump set.
Supply only deep groove ball bearing suitable for 15HP Motor complete all as specified and directed.
Supply only rotor with shaft complete suitable for 15 HP motor complete all as specified and directed.
Supply only coupling set complete suitable for 15 HP motor complete all as specified and directed.
M&L for rewinding of centrifugal electric motor cap 15 HP with super enameled copper winding wire make HTP/Devi Dyal of same size/ gauge as existing after providing 'F' class insulation material and varnishing complete all as specified. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
All as per item No 1.00 here in before but for capacity of 20 HP pump set.
Supply only deep groove ball bearing suitable for 20 HP Motor complete all as specified and directed.
Supply only rotor with shaft complete suitable for 20 HP motor complete all as specified and directed.
Supply only coupling set complete suitable for 20 HP motor complete all as specified and directed.
M&L for rewinding of centrifugal electric motor cap 20 HP with super enameled copper winding wire make HTP/Devi Dyal of same size/ gauge as existing after providing 'F' class insulation material and varnishing complete all as specified. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
All as per item No 1.00 here in before but for capacity 30 HP pump set.
Supply only deep groove ball bearing suitable for 30 HP Motor complete all as specified and directed.
Supply only PVC fan complete suitable for 30 HP motor complete all as specified and directed.
Supply only rotor with shaft complete suitable for 30 HP motor complete all as specified and directed.
Supply only coupling set complete suitable for 30 HP motor complete all as specified and directed.
M&L for rewinding of centrifugal electric motor cap 30 HP with super enameled copper winding wire make HTP/Devi Dyal of same size/ gauge as existing after providing 'F' class insulation material and varnishing complete all as specified. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
All as per item No 1.00 here in before but for capacity 40 HP pump set.
Supply only deep groove ball bearing suitable for 40 HP Motor complete all as specified and directed.
Supply only rotor with shaft complete suitable for 40 HP motor complete all as specified and directed.
Supply only coupling set complete suitable for 40 HP motor complete all as specified and directed.
M&L for rewinding of centrifugal electric motor cap 40HP with super enameled copper winding wire make HTP/Devi Dyal of same size/ gauge as existing after providing 'F' class insulation material and varnishing complete all as specified. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
All as per item No 1.00 here in before but for capacity 50 HP - 60 HP pump set.
Supply only deep groove ball bearing suitable for 50 HP - 60 HP Motor complete all as specified and directed.
Supply only rotor with shaft complete suitable for 50 HP - 60 HP motor complete all as specified and directed.
Supply only coupling set complete suitable for 50 HP motor complete all as specified and directed.
M&L for rewinding of centrifugal electric motor cap 50 HP - 60 HP with super enameled copper winding wire make HTP/Devi Dyal of same size/ gauge as existing after providing 'F' class insulation material and varnishing complete all as specified. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
Dismantling of defective centrifugal sewage pump for inspection and identification of serviceable and unserviceable parts for repair and overhauling and reassembling after replacement of unserviceable parts suitable for 7.5-10 HP pumpset by dismantling of suction & delivery pipe lines and taking out carefully, transporting to workshop for repair. Reassembling after repairs and testing, re-installation by connecting suction & delivery pipe line and testing complete all as specified and directed. Note :- Minor Items ie gland packing ,Nut bolts insulation tape and greasing , rubber gasket etc. required are deemed to be included in unit rate of above item. (i) Spare parts required for repair will be measured and paid under relevant item of seh “A” as supply only. (ii) Labour required for dismantling the pump set for removing defective spare parts and re-assembling after fixing new spares are deemed to be included in unit rate of above item. (iii) Cont will send daily his rep to yard for getting complaint, after getting complaint contracter will rectified bottelnecks with in 24 Hrs if fail for any reason,a fine of Rs 1500/- per day
Supply only impeller suitable for 7.5-10 HP pump complete all as specified and directed.
Supply only parallel key suitable for 7.5-10 HP pump complete all as specified and directed.
Supply only sleeve suitable for 7.5-10 HP pump complete all as specified and directed.
Supply only deep groove ball bearing suitable for 7.5-10 HP pump complete all as specified and directed.
Supply only mechanical seal suitable for 7.5-10 HP pump complete all as specified and directed.
All as per item No 7.00 here in before but suitable for 15 HP pump complete all as specified and directed.
Supply only impeller suitable for 15 HP pump complete all as specified and directed.
Supply only parallel key suitable for 15 HP pump complete all as specified and directed.
Supply only sleeve suitable for 15 HP pump complete all as specified and directed.
Supply only deep groove ball bearing suitable for 15 HP pump complete all as specified and directed.
Supply only mechanical seal suitable for 15 HP pump complete all as specified and directed.
All as per item No 7.00 here in before but suitable for 20 HP pump complete all as specified and directed.
Supply only impeller suitable for 20 HP pump complete all as specified and directed.
Supply only parallel key suitable for 20 HP pump complete all as specified and directed.
Supply only sleeve suitable for 20 HP pump complete all as specified and directed.
Supply only deep groove ball bearing suitable for 20 HP pump complete all as specified and directed.
Supply only mechanical seal suitable for 20 HP pump complete all as specified and directed.
All as per item No 7.00 here in before but suitable for 30 HP pump complete all as specified and directed.
Supply only impeller suitable for 30 HP pump complete all as specified and directed.
Supply only parallel key suitable for 30 HP pump complete all as specified and directed.
Supply only sleeve suitable for 30 HP pump complete all as specified and directed.
Supply only deep groove ball bearing suitable for 30 HP pump complete all as specified and directed.
Supply only mechanical seal suitable for 30 HP pump complete all as specified and directed.
All as per item No 7.00 here in before but suitable for 40 HP pump complete all as specified and directed.
Supply only impeller suitable for 40 HP pump complete all as specified and directed.
Supply only parallel key suitable for 40 HP pump complete all as specified and directed.
Supply only sleeve suitable for 40 HP pump complete all as specified and directed.
Supply only deep groove ball bearing suitable for 40 HP pump complete all as specified and directed.
Supply only mechanical seal suitable for 40 HP pump complete all as specified and directed.
All as per item No 7.00 here in before but suitable for 50 HP-60 HP pump complete all as specified and directed.
Supply only impeller suitable for 50 HP - 60 HP pump complete all as specified and directed.
Supply only parallel key suitable for 50 HP - 60 HP pump complete all as specified and directed.
Supply only sleeve suitable for 50 HP-60 HP pump complete all as specified and directed.
Supply only deep groove ball bearing suitable for 50 HP - 60 HP pump complete all as specified and directed.
Supply only mechanical seal suitable for 50 HP - 60 HP pump complete all as specified and directed.
Dismantling of defective Submersible sewage motor pumpset of capacity 3 HP by removing cable connection from LT panel and suction & delivery pipe lines and taking out carefully, tranporting to workshop for repair. Reassembling after repairs and testing, transporting back to sewage well reinstallation and fixed the suction & delivery pipe line , and connecting electric cable to LT panel and testing complete all as specified and directed. Note :-(i) The cost also includes for making stand by arragnment to avoid any type of breakdown by putting standby motor/pumpset all as directed by Engr-in-charge. (ii)Minor Items costing up to RS 300/- i.e gland packing, Nuts bolts , insulation tape, Rubber seal, Hozing bushes etc required are deemed to be included in unit rate of above item. (iii) spares parts required for repair will be measured and paid under relevent item of Sch 'A' as supply only.(iv) Labour and tpt required for dismantling defective pump set for removing of defective spare partsand re-assembling after fixing new spares are deemed to be included in unit rate of above item. (v) Cont will send daily his rep to yard for getting complaint, after getting complaint contracter will rectified bottelnecks with in 24 Hrs if fail for any reason,a fine of Rs 1500/- per day
Supply only rotor with shaft complete suitable for 3 HP motor complete all as specified and directed.
Supply only lower bearing complete suitable for 3 HP motor complete all as specified and directed.
Supply only upper bearing complete suitable for 3 HP motor complete all as specified and directed.
Supply only mechanical seal complete suitable for 3 HP pump complete all as specified and directed.
Supply only impeller complete suitable for 3 HP pump complete all as specified and directed.
M&L for rewinding of submersible electric motor cap 3 with PVC insulated copper wire of existing size/guage make HTP/ Devi Dyal/National including insulation material complete all as required. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
All as per item No 13.00 here in before but suitable for 5 HP motor pumpset complete all as specified and directed.
Supply only rotor with shaft complete suitable for 5 HP motor complete all as specified and directed.
Supply only lower bearing complete suitable for 5 HP motor complete all as specified and directed.
Supply only upper bearing complete suitable for 5 HP motor complete all as specified and directed.
Supply only mechanical seal complete suitable for 5 HP pump complete all as specified and directed.
Supply only impeller complete suitable for 5 HP pump complete all as specified and directed.
M&L for rewinding of submersible electric motor cap 5 with PVC insulated copper wire of existing size/guage make HTP/ Devi Dyal/National including insulation material complete all as required. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
All as per item No 13.00 here in before but suitable for 7.5 HP motor pumpset complete all as specified and directed.
Supply only rotor with shaft complete suitable for 7.5 HP motor complete all as specified and directed.
Supply only lower bearing complete suitable for 7.5 HP motor complete all as specified and directed.
Supply only upper bearing complete suitable for 7.5 HP motor complete all as specified and directed.
Supply only mechanical seal complete suitable for 7.5 HP pump complete all as specified and directed.
Supply only impeller complete suitable for 7.5 HP pump complete all as specified and directed.
M&L for rewinding of submersible electric motor cap 7.5 with PVC insulated copper wire of existing size/guage make HTP/ Devi Dyal/National including insulation material complete all as required. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
All as per item No 13.00 here in before but suitable for 25 HP motor pumpset complete all as specified and directed.
Supply only rotor with shaft complete suitable for 25 HP motor complete all as specified and directed.
Supply only lower bearing complete suitable for 25 HP motor complete all as specified and directed.
Supply only upper bearing complete suitable for 25 HP motor complete all as specified and directed.
Supply only mechanical seal complete suitable for 25 HP pump complete all as specified and directed.
Supply only impeller complete suitable for 25 HP pump complete all as specified and directed.
M&L for rewinding of submersible electric motor cap 25 with PVC insulated copper wire of existing size/guage make HTP/ Devi Dyal/National including insulation material complete all as required. Note : Contracter will give Warranty of rewinded motor for at least 3 months minimum.
Carrying out servicing/maint of 125 KVA DG set, Make : 'Greaves/Kirloskar' including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer against item No.1 above.
Supply only Lub oil filter cartrige
Supply only Diesel filter insert
Supply only Fuel pre filter
Supply only Air clean element secondary
Supply only Hose pipe & Flexible pipe complete set.
Supply only Fan belt for alternator dynamo (make-Fenner/ Poly-F/Roulunos).
Crank shaft assy with gear
Fuel pump assembly
Exhaust Silencer
Carrying out servicing/maint of 50-62.5 KVA DG set, Make : 'Greaves/Kirloskar' including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer against item No.1 above.
Supply only Lub oil filter
Supply only Fuel filter insert
Supply only Air clean element
Supply only Hose pipe & Flexible pipe complete set.
Supply only Fan belt for alternator dynamo (make-Fenner/ Poly-F/Roulunos).
Supply only Exhaust Silencer
Carrying out servicing/maint of 15 KVA-30 KVA DG set, Make : 'Greaves/Kirloskar' including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer against item No.1 above.
Supply only Lub oil filter
Supply only Fuel filter insert
Supply only Air clean element
Supply only Hose pipe & Flexible pipe complete set.
Supply only Fan belt for alternator dynamo (make-Fenner/ Poly-F/Roulunos).
Repair/servicing of radiator assembly of 125 KVA DG Set (Greaves/Kirloskar/Cummins) after dismanteling and removing cooling fans, guard plates and lowering the same from engine after draining out water from radiator and scrapping / removing sludge / scale inside tank with acid including replacement MS tank (botom portion) at rusted portion by cutting/ welding / brazing with 2mm thick copper plate including painting. Remounting the same at its original position and repalcement of pre mixed coolent as per the ratio fixed by manufacturer and testing complete all as directed by Enginer-in-Charge. (Note- Pre mixed coolent shall be measured and paid separately under relevant item of schedule)
All as per item No. 22 but for 62.5 KVA DG Set of Greaves /Cummins / Kirloskar.
Supply and fixing in replacement of new Self starter, auto lock, 12/24V of existing make, on the 125 KVA DG Set and taking out u/s self starter from DG set.
All as per item No. 24 but for 62.5 KVA DG Set.
Taking down unserviceable Self starter from the DG Set 15-125 KVA including dismantling the Self starter and taking out burnt winding armature & field coil and cleaning the slot including re winding of armature, field coil with enameled copper conductor of existing gauge including insulating material and heat varnish. Replacing worn out armature auto lock-01PC,Carbon brushes set, Pinion set, copper bush Set, Guard piece rubber, carbon rocker, Solinoid coil and reassembling the Self starter and mounting on its original position by replacing worn out nut bolts washers including painting of self starter all as directed by the Engr in Charge.
Dismantling and opening of turbo charger assembly of 62.5KVA to 125 KVA DG Set and Supply and fixing of turbo charger kit including refixing, testing complete as directed by Engineer in Charge.
Repair/Servicing of water pump and replacement of water kit and water seal of 15 KVA to 125 KVA DG Set complete all as directed.
Dismantling and taking down alternator assembly from existing engine and transporting to workshop and carry out servicing / maintenance of alternator unit of capacity 125 KVA DG set as per the phase work :- (a) Opening of Alternator and cleaning / remvoing dust from armature and field coil. (b) Cleaning of used / old lubricated substances drive/non drive end bearings. (c) Cleaning end cheeking of AVR unit (d) Cheking and tighting of coupling bolts and replacement of rubber inserts. (e) M&L for carrying out heat varnishing for field and armature coil and kept in heating chamber for 48 hours for drying properly. (f) Replacement of Bearings as per existing size. (g) Reassembling complete unit and carrying out testing at workshop and transportation to installation and coupling with DG Set including necessary alignment, cable connections all as specified and directed by Engr - in Charge
Rewinding of armature with super enamelled copper of required size wire including varnishing, sleeves, cotton tape and heating etc. for DG Set of capacity 62.5 KVA to 125 KVA, complete, all as specified and directed. Note : cost of winding wire shall be included in quoted rate.
All as per srl item No 32 here-in-before but for 15 KVA to 30 KVA DG set.
Dismantling, rewinding of field coils of alternator with super enamelled wire including varnishing and heating including reassembling and testing for capacity of DG Set 125 KVA, complete, all as specified and directed. Note : Cost winding wire shall be included in quoted rates.
All as item No 34 here-in-before, but for 62.5 KVA DG set.
Supply only Ball bearing suitable for 62.5 to 125 KVA DG set
Taking out unserviceable diesel tank 100 to 300 Litres for 62.5 to 125 KVA DG set and S&F new fabricated diesel tank less than suitable Capacity 14 Gauge CRCA sheet duly painted with fuel indicatior which is to be fitted in existing canopy without making any damage to canopy,including replacement of glass wool insulation 80 mm thick density 30 Kg per Cum, which is covered with NET GP Sheet stainless steel with the help of rivets for all over canopy of DG set ,reparing of unserviciable top cover of DG set duly painted and replacement of rubber beading of existing shape and size all along the periphery of the doors complete all as specified and as directed.
M&L for dismantling, opening of diesel engine cylinder head, removal of unservieable worn out spare parts, cleaning of all components, reboring of cylinder on lathe machine, after reboring honning process will be carrred out,replacement of all spare parts and gaskets as per manufacturer spare part kit, re-assembling of complete engine setting, timing setting for the capacity of 62.5-125 KVA DG set complete all as specified and as directed. Note:- Spare parts will be measured and paid seperately under respective item of BOQ.
Supply only Piston ring set suitable for 62.5-125 KVA DG Set of existing make complete all as specified and as directed.
Supply only Main bearing set suitable for 62.5 to 125 KVA DG Set of existing make complete all as specified and as directed.
Supply only Oil pump assembly with drvg gear suitable for 62.5 to 125 KVA DG Set of existing make complete all as specified and as directed.
Supply only Valve (inlet and outlet valve) suitable for 62.5 - 125 KVA DG Set of existing make complete all as specified and as directed.
S&F in replacement ofHead gasket suitable for capacity of of DG set 125 KVA complete all as specified and as directed.
S&F in replacement of sheet metal enclosure type change over switch on load front handle four pole 415 volts 50 Hz 200 Amps including mounting arrangement of metallic frame work of appropriate section and size on walls or panels complete all as specified and as directed. Make:- Havells/L&T/C&S Note:- Making connections to the electric system, including cutting of cable of any size and type, making end termination by using suitable lugs is included in the rate quoted under this item.
Disconnecting, taking out carefully old unserviceable AVR unit, supply & fixing, connecting and testing new AVR unit as per existing make and model suitable for DG set of 125KVA capacity. Make Kirloskar/National/ Universal/cummins
Supply only lubrication oil SAE-40 ( 15 W- 40 grade) of Make: Valvoline as approved by GE.
Supply and filling of inhibitor corrosion (Fleet-Guard make Coolant) suitable for radiators of 18.75 KVA to 125 KVA capacity DG set complete all as specified and directed
S&F as in repair stainless steel locking arrangement for DG set canopy gates rating from 15 KVA to 125 KVA complete all as specified and directed.
M&L for repair of hinges of gate of DG set conopy incl the repair of gate of any cap all as specified and directed
Supply Battery Terminals Copper.(Positive & Nagative) complete.
Supply Battery Copper cable Red with plug complete(1 Mtr Length).
Supply Battery Copper cable Black with plug complete (1 Mtr Length).
S&F of Submersible Copper cable 3 core, 6 sqmm including lowering/lifting of submersible pump set MAKE : Finolex/CCI /GLOSTER.
S&F of Submersible Copper cable 3 core, 10 sqmm including lowering/lifting of submersible pump setMAKE : Finolex/CCI /GLOSTER.
S&F of Submersible Copper cable 3 core, 16 sqmm including lowering/lifting of submersible pump set. MAKE : Finolex/CCI /GLOSTER.
S&F of Submersible Copper cable 3 core, 25 sqmm including lowering/lifting of submersible pump setMAKE : Finolex/CCI /GLOSTER.
Supply & Fixing LED Bldg security light 45 watts,pressure die cast aluminium housing,heat resistane toughened glass with frame,IP 66 protection with bracket (for housing street light fittings) made of GI pipe 40 mm dia light grade 1.20 mtrs long duly cutted and welded at an angle of 120 degree and fixed to wall with 50 mm X 6 mm MS clamps - 02 Nos with 16 mm dia bolts,nuts,and washers complete all as specified and directed incl taking down of old unserviceable fitting of any type..
Supply & Fixing LED flood light fitting 100 watts,pressure die cast aluminium housing,heat resistane toughened glass with frame,IP 66 protection with bracket for housing floo light fittings complete all as specified and directed incl taking down of old unserviceable fitting of any type as per Crompton Cat Part No LSFN-120-CDL/60/M
Supply only LED cluster indicator lamp Red, Blue, Yellow.
Supply,Laying, testing in replacement of UG cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 95 sqmm 3.5 core complete all as specified. Note : Cable shall be replaced from LT Panel near transformer to LT panel inside the Pump House.
All as per item No 75 here-in-before but for 70 Sqmm 3.5 Core complete all as specified and directed.
All as per item No 75 here-in-before but for 50 Sqmm 3.5 Core complete all as specified and directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep for pipe line/cable in any type of soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25Cum thick all as specified and directed.
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point all as directed.
Supplying and laying of Sub class 'B' bricks in trenches for protection to cable all as specified.
Supplying and laying in trenches Sand for cushioning as specified.
S&F MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA all as specified and directed.
S&F MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA all as specified and directed.
S&F in replacement moulded case circuit breakers 4 pole 100 Amps having breaking capcity 16 KA at 415 volts of Make L&T or equivalent in Havell's/Siemens
S&F in replacement moulded case circuit breakers 4 pole 63 Amps having breaking capcity 16 KA at 415 volts of Make L&T or Equivalent in Havells / Siemens .
M&L for cleaning of Sump Well with opening of choked/jammed suction/delivery all lines of sewage pump in sump well ( size upto 10 mtr dia and 10 mtr depth max) fitted with submersible sewage pumpset of capacity upto 60 HP by rodding , air presure or other mechanical means for removing of setteled down sludge at the bottom of sump well and made the line severiciable all as directed. Note :- Any other work reqd for cleaning the choked lines/removal of sludge includes elctrician work, plumbing works or mechanical means reqd if any is deemed to be included in quoated rate
Shifting of Motor coupled Centrifugal Pumpset of any Capacity into Sumpwell including Machining, Forming, welding works alongwith its Dismantling, removing cable connection, Lowering, Reassembling, cable jointing and testing all as specified and directed.
Supply and fix in repair for cast iron sluice valve suitable for 150mm bore CI pipe flanged type, class PN-1 with brass spindle both ends flanged conforming to IS 14846 , including jointing with rubber insertion sheet 3mm thick, bolts, nuts & washers complete all as specified and directed . Make Kirlosakar/leader/ Kartar/BIR
S&F in repair Non Return valve R/Flap FL duly ISI marked and both ends flanged of 200 mm bore, conforming to BIS 5312 including jointing with rubber insertion sheet 3mm thick, bolts, nuts & washers complete all as specified and directed fixed in repair complete. Make Kirlosakar/leader/ Kartar/BIR
S&F in repair Non Return valve R/Flap FL duly ISI marked and both ends flanged of 150 mm bore, conforming to BIS 5312 including jointing with rubber insertion sheet 3mm thick, bolts, nuts & washers complete all as specified and directed fixed in repair complete. Make Kirlosakar/leader/ Kartar/BIR
S&F in repair Non Return valve R/Flap FL duly ISI marked and both ends flanged of 100 mm bore, conforming to BIS 5312 including jointing with rubber insertion sheet 3mm thick, bolts, nuts & washers complete all as specified and directed . Make Kirlosakar/leader/ Kartar/BIR
Taking out DI/CI line for repair & cleaning of pipe 150/100 mm dia CI Class"B" both ends flanged and fixing with MS Nut bolts and rubber insertion sheet 3 mm thick of 150 mm dia complete all as specified and directed.
M&L in repalcement of rusted/unserviceable MS clamp of suitable size with nut,bolts & washers complete for hanging of submersible pump set with column pipes in bore well any size/cap and MS Cap of suitable size as casing cover of bore well complete all as directed by Engr-in Chrge
M & L in replacement of Cast iron specials, ISI marked such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing,decreasing or double socket etc.) Tee piece single branch."Y" junction,double branch,cross(all sockets or socket and spigot collars,caps and plugs upto 300 mm bore.
Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 25 x 4mm dia connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed.
M& L for color code painting over the complete CI pipe line of Sewage Pump House with two coats of Black synthetic enamel paint after one coats of red synthetic enamel paint complete all as specified and directed.
Testing of Treated and Untreated water STP Sample by obtaining samples from STP and submission of Phsiochemical Analysis Report with all parameters i.e PH, TSS, BOD,COD etc complete from laboratory approved by MES all as specified and directed by Engineer in Charge.
Detecting leakage of water supply pipe lines of Cast iron of size 150mm bore from any location, any depth and repairing by providing jointing material,"D" joints, lead, lead wool , flanged, clamps, nuts, washers & bolts etc. complete all as directed and specified including Earth work etc.
Supply and fixing Pipe cast Iron both ends flanged and drilled, including specials ,Class "B" 150 mm (6") dia complete all as specified and directed.
DHAWAN CONSTRUCTION COMPANY
M/s Surjit Singh and bros
KAILASH CONSTRUCTION COMPANY
Harmesh Kumar Sharma and Sons
M/s Manoj Construction Co.
JAWAHAR CONSTRUCTION COMPANY
CHETAK CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .