| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹20.6 L+₹2.2 L (12.2%)Rejected-Finance NO 21 BRAMIN STREET KORATTUR CHENNAI 600080 | CHENNAI | CHENNAI | TAMIL NADU | 600080 | L2 | Rejected-Finance Not Being lowest | |
| 3 | L3₹21.4 L+₹3.0 L (16.2%)Rejected-Finance | L3 | Rejected-Finance Not Being lowest |
Tender Value
₹23.6 L
EMD Value
₹47,200
Closing Date
13 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
ADDN / ALTN TO BLDG NO.T-15 OF MADAMBAKKAM AT AIRFORCE STATION TAMBARAM
2023_MES_603502_1
GE(AF)/TBM/8634/E8
Open Tender
Civil Works
Item Rate
180 days
AIRFORCE STATION TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹47,200
Yes
12 Aug 2023
15 Jun 2023
15 Jul 2023
15 Jun 2023
13 Jul 2023
1 Jul 2023
16 Jun 2023 - 22 Jun 2023
Amount
Excavation in post holes (or similar holes) in hard/dense soil each not exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exc 50 m and making good surface all as specified and directed.
M&L for surface dressing not exc.15 cm deep in soft/loose soil, complete all as specified and directed.
M&L for Plain cement concrete Type C2, 1:3:6 using 40 mm graded stone coarse aggregate in foundations,filling and mass concrete all as specified and as directed
S&F steel work in tubular trusses i.e. Truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and as directed
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-0 or Fe 310-0 (Brackets over 10kg each to be measured under `Structural Steel') all as specified and as directed
S&F Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0..9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members all as specified and as directed
S&F Plain, black, mild steel sheeting 0.80mm thick as in ridges, hips, valley gutters,drip and straight flashings (length and girth as fixed) all as specified and as directed.
M&L for two coat of synthetic enamel paint over a coat of primer including preparation on steel surfaces of any description over 10 cm width or girth complete all as specified and as dircted
S&F for anodised aluminium snap grid frame work for false ceiling with grid size of 605x605 mm with using aluminium angle 25x25x3mm and T sections 25x25x3mm all as specified in clause 10.38 of SSR pt-I (2009) complete all as specified and directed. ( Note: The quoted rate shall includes for drilling anchor fastners and hanging rod from ceiling etc all as per manufacturer instructions)
M & L False ceiling board with 8 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600 mm grid (Frame work for ceiling shall be measured and paid seperately).
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified as specified.
M&L 25mm thick PCC 1:2:4 Type B-0 Using 12:5mm graded stone aggregate as in base floor , complete all as directed and specified .
M&L vitrified coloured tiles 10 mm thick dark shade (square/ rectangular) area of each tiles exceeding .18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick cement screed bed in cement mortar 1:6 for laying floor finishes. complete all as specified and directed.
All as per item no 15 above but as in skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match,over and including 10 mm thick rendering in cement mortar (1:4), rough finish to receive the tiles complete all as specified & directed
M&L non skid coloured ceremic tiles 7 to 8 mm thick (square/ rectangular) area of each tilles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. Set & jointed in neat cement slurry and pointed in colored cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in cm (1:6) complete all as specified and directed
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys , scrubing down with water etc, complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with liquid water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only under respective item of sch A.
M & L Rendering 15 mm thick on brick wall or concrete surface cement mortar 1:6 finished fair and even complete all as specified and as directed.
M&L Glazed ceremic tiles in vertical surface 350x250x7 mm /450x350x7 mm thick set & jointed in neat cement slurry and pointed in colored cement to match coloured tiles laid over and including 10 mm thick screed bed or bedding layer in cm (1:3) complete all as specified and directed
Supply only Liquid water proofing compound ISI Marked (to be used as 200 ml per bag of cement) complete all as specified and directed.
M&L for preparing of new plastered surface on wall and applying two coats of Oil bond distemper over a coat of appropriate wall primer over 3 mm thick wall care putty complete all as specified and directed.
M&L for preparing of new plastered surface on wall and applying two coats of cement base paint over a coat of exterior wall primer on plastered surface complete all as specified.
M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed
S & F for Providing precast cement concrete louvres and jallies, 60mm thick (measured solid), including all mouldings complete all as specified and directed
S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia. all as specified and directed
S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia. all as specified and directed
M&L RCC 1:2:4 type B-1 nominal mix as in beams, bands etc using 20 mm graded stone aggregate all as specified
Form work to soffits of suspended slabs flat surface of concrete finished rough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed.
Taking down chowkats or frame of any description not exc. 1.5 Sqm each (without taking off shutters from the frames) & remove off the premises complete all as specified and directed.
Taking down chowkats or frame of any description exc 1.5 Sqm each and not exc 4Sqm (without taking off shutters from the frames) & remove off the premises complete all as specified and directed.
S&F anodised aluminium frame powder coated with minimum thickness of powder coating 50 Micron for window, ventilators with one or more rebated including joining cleat for fixing etc complete all as specifed and directed.
S&F powder coated any colour aluminium window and ventilators shutters (Minimum thickness of powder coating 50 Micron) sliding type without sash bars, alumninium section weigning 1.5 kg/sqm including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beding screws etc complete all as specifed and directed.
S&F powder coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary jointing cleats/ glazing clips, rubber neoprene packing, handles 2 Nos in each door , locking arrangment, aluminium snap beading screw etc, complete all as specified and directed. ( minimum thickness of powder coated should be 50 micron)
S&F Galvanised mild steel wire cloth 0.63 mm nominal dia and average width of aperture 1.40 mm fixed all as specified and directed.
S&F aluminum alloy door closer hydraulically regulated, desination No 1 universal type, suitable for door shutters upto 700mm in width and of weight not more than 35 Kg and fixed to door frame complete all as specified and directed.
S&F 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice laminations,fixed with screw to timber frame work and sealing edges of board with PVC beading by chemical adhesive complete all as specified and directed.
M&L for 5.5 mm thick sheet glass ordinary quality in panes not exc 0.50 sqm each fixed with and including rubber gasket in aluminium frame work complete all as specified and directed.
M&L sheet glass ordinary quality 5.5 mm thick and glazing with nesscessary adhesive or fixing material in squares exc 0.5 sqm each pane complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F MS angle iron as in door frame work conforming to Fe 290(Gde E-165) including tie rod, hinges including one shop coat of red oxide primer etc. complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS sqare tube, complete all as specified and directed.
S&F factory made solid PVC moulded door shutters 28 to 30mm thick stiles), with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on back face, with particle boardcore, Supplying and fixing in frame at site as per specifiecation & drawing shown in section 8 of SSR part-II complete all as directed.
S&F 150mm size aluminium, anodised barrel tower bolt of extruded section.
S&F 300mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F 100mm size butt hinges, medium weight, cold rolled mild steel, and fixed.
S&F 150mm size extruded aluminium alloy handles, fabricated type.
M&L for hardcore of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stones or boulders, complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base of path, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in path, 50 mm thick finished even and fair without using extra cement all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L 20mm thick screed bed in CM 1:6 for floor finishig complete all as directed.
M&L Precast Cement concrete heavy duty deisigner tiles of size 250x250x25 mm set , jointed and pointed in neat cement slurry in floors with grey cement complete all as specified and directed.
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 15 mm dia pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20 mm dia pipes complete all as specified and directed.
S&F for laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F for laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills sunshades, shelves lintels etc and cutting chases for concealed water pipe etc and making good cutting not exc 10cm.complete all as specified and directed.
S&F in repair Vitreous china white EWC (pedestal Pattern) including complete fixing arrangement excluding flushing cistern and flush pipe complete all as specifed and directed
S&F plastic water closet seat cover white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed.
S & F for vitreous China Urinal, full stall type, white including CP urinal spreader ,excluding flushing cistern, flush pipe and waste pipe, complete all as specified and directed
S&F low level Flushing cistern 10 ltr capacity, PVC valveless syphonic action type, white with inlet, ball valve, float valve and handle , flush pipe, including brackets and flushing pipe fixed in repairs complete all as specified and directed
S&F vitreous china,white, wash hand basin, flat back size 550x400mm including MS brackets, cutting for and pinning in, waste pipe etc complete all as specified and directed
S&F 20mm dia brass chromium plated tubular towel rails,D type, 60cm long between flanges,complete all as specified.
S&F 75 mm dia Cast iron nahani trap with CP grating including including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed
S&F soap dish chromium plated fancy type fixed with screw to wall complete all as specifed
S & F fancy type chromium plated health faucet with 1.2 Mtr long PVC tube cover CP flexible with wall hook, suitable for 15 mm bore pipe or for union and fixed complete all as specified and directed.
S&F 20 mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
S&F in 15mm size PVC connections internally threaded with PVC washer,PTMT nuts , length 450mm complete all as specified and directed.
S&F CP steel Grating 100 mm dia fixed on floor complete all as specified and directed.
S&F 15 mm dia bib tap cast copper alloy (fency type), chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as all as specified and directed.
S&F Stop valves 15 mm bore, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed.
S&F 15 mm dia stop valve chromium plated concealed fancy type with long shank and cup complete all as specifed and directed.
S&F 15 mm dia brass chromium plated pillar tap, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut, capstan head, screwed for 15mm dia pipe complete all as directed.
S&F PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid trenches or in floor complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid trenches or in floor complete all as specified and directed.
S&F PVC (SWR) bend 110mm dia , any radius as required and jointed with approved adhesive complete all as specified and directed.
S&F PVC (SWR) junction single (Single T) equal or un equal 110mm dia , any radius as required and jointed with approved adhesive complete all as specified and directed.
S&F PVC (SWR) bend 75 mm dia , any radius as required and jointed with approved adhesive complete all as specified and directed.
S&F PVC (SWR) junction single (Single T) equal or un equal 75 mm dia , any radius as required and jointed with approved adhesive complete all as specified and directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, sockets,ceiling rose, pendents, regulators,sockets,light fitting etc complete as ordered and removing retrived materials and making good the disturbed surface of wall, floors, ceiling etc. complete all as directed and specified.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store. Refixing/hanging only ceiling fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes with earth dolly duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following:- (a) One light Point Controlled by one oneway switch
(b) One ceiling fan point controlled by one switch
(C) One Exhaust fan point controlled by one, one way switch
(d) One 5Amps socket point on same board with other switches
(e) One 5 Amps socket point on Independent board
All as per item No 85 here in before but with 2.5 sqmm for power point 15 amps.
Supply and fix Switch flush type, 5 amps 240 volts single pole one way
Supply and fix switch socket combination 2/3 pin 5 amps 240 volts flush type.
Switch socket combination 2 in 1 multipurpose 5/15 amps 240 volts universal type.
Fan regulator electronic type with 5 step control suitable for 1200/1400 mm ceiling fan.
Ceiling rose surface PVC insulated three plates "JUMBO' type 240 volts
Supply and fixing in replacement of Wall mounted light fitting LED batten, extruded aluminium heat sink provided for effcient heat dissipation & integrated electronic driver with 20 W LED 6500K (4 ft) lamp including disconecting, removing, and connecting into electric circuit and testing all as per Havells Cat part No. LUMILINEBS20WLED865SPCWH or Equivalent make from list of Makes.
Supply and fix surface and wall mounted 9 Watt LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & intergrated electronic driver including LED lamp complete all as per Havells Cat No.LUMILINEBS9 WLED865SPCWH or Equivalenet make from list of Makes.
Supply and fix recess mounted 2 x 2 panel LED light fitting complete and connecting into electric circcuit and all as per Havells Cat part No PLANO2X2PLR42WLED857S or Equivelant make from list of Makes.
S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 35W LED 5000K lamp all as per Havells Cat No.ENDURASUNDOWNSL35WLED765PASYBOPCIHD or equivalenet make from list of makes including disconecting, removing, and connecting into electric circuit including testing. .
GI Bracket bend to shape in cold or hot 40mm bore medium grade and 1.50 M long with suitable MS clamps and nuts bolts etc, for fixing security light fittings to Bldgs complete after taking down the unserviceable GI bracket all as directed.
Taking down the existing unserviceable Main switch/MCB DB from its position for fixing of new DB and making good the disturbed surface all as directed.
Supply & fixing of Sheet metal enclosure with distribution board Double Door 415 volts TPN 4 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections all as directed
Supply and fixing MCB TPN 63 Amps, 10 KA.415V
Supply and fixing MCB Single pole 6-32 amps, 'C' Curve, 10 KA , SP 240V
Supply and fix heavy duty Exhaust fan 300 mm sweep 900 RPM, Turbo force SP with louver shutter and connecting including making holes for Exhaust Fan and provision of 3 core cable of 0 .5 sqmm from ceiling rose to fan all as directed. Make: Havells Model : Turbo Force SP Or equivelant make of Crompton/Khaitan/Bajaj/Almonard /Orient/GEC
Excavation in trenches not exc 1.5m in width and 1.5 M in depth and getting out excavated soil soft/loose soil all as specified and directed.
Returning fitting in, including spreading, levelling, watering and well ramming in layers not exc 25cm all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
Laying spreading in layers riddled sand obtained from excavated soil as in cable protection all as specified and directed.
Supply and laying bricks sub class 'B' laid across the length of the trenches for protection of UG cable all as specified and directed.
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured heavy duty LT UG electric cable with aluminium conductor 1100V grade of size 16 sqmm 4 core all as specified and directed.
Supply and laying GI pipe light grade of 25 mm dia in trenches/fixed on poles by suitable clamps and jointing complete all as specified and directed.
Supply and fix Industrial type sheet steel enclosure with metal clad plug and socket single pole neutral and earth plug and socket 20 Amp MCB SP controlled by and including one number of 20 Amps MCB SP complete all as specified and as directed
M&L Circuit Sub main wiring 2 x 6.0 Sqmm single core FRLS PVC insulated unsheathed cable single core multistranded copper conductor 1100 volts grade drawn through with and including suitable size of PVC conduit and conduit accessories fixed on concealed with suitable clamps/saddles including one run of 6.0 sqmm FRLS PVC insulated copper cable for continuous earth conductor connected to common earth dolly all as specified and as directed . ( Note : 3 Runs of 6sqmm wire and 1 run of PVC conduit together shall be measured as one unit length)
Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth wire 4.0 mm GI strip means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion. Note : The GI wire 4.0 mm and GI earth protection pipe 15 mm upto 7.5 mtr lenght is included in the unit rate and beyond 7.5 mtr shall be measured and paid seperately.
S & F down rods fabricated out of 15 mm dia GI pipe medium grade duly cutting/ threading/ drilling etc. Suitable for check nut and split pin including 'U' clamp bolts, nuts, washers, rubber split pin check nut etc suitable for ceiling fan 1200/1400 mm sweep including taking down of unserviceable complete all as specified and directed.
S& F ceiling fan complete with three blades ,down rods ,electronic regulator and accessories ,230V,1200 mm sweep .Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete with all connection all as specified and directed.
kvs constructions
M R Govinda Reddy and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .