GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR REP OF LT CABLE MAINT OF EXTERNAL LT ELECTRIC SUPPLY REPAIR REP OF STREET LIGHT SECURITY LIGHT SOLAR LIGHT REPAIR REWIRING OF INTERNAL ELECTRIC WIRING LIGHT FITTING MAINT OF SUMMER COOLING APPLIANCE OF ADM AREA CPE ITARSI UNDER GE BHOPAL
2023_MES_627354_1
8224/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
ITARSI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹99,800
Yes
14 Feb 2024
8 Nov 2023
6 Dec 2023
8 Nov 2023
4 Dec 2023
22 Nov 2023
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Excavation in trenches in soft/loose soil n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out for foundation of pole, laying under ground cables etc and getting out complete all as specified and directed.
Excavation in trenches in soft/disintegrated soil exceeding 1.5 mtr wide and n.exe 3 mtr depth including getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soil complete all as specified and directed.
Removing excavated soil to a distance n. exc 50m and deposited at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for river washed and screened dry sand for filling in trenches below and around the cable for cushioning including punning down as per relevant clause of SSR Part I complete all as specified and directed. Note: Punned thickness shall only be measured for payment.
Supplying and laying, class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete including filling at road cuttings or making pillars for supporting pipe including necessary form work complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed. including necessary form work complete all as specified and directed.
Dismantling of LT insulator of any type any size complete all as specified and directed.
M&L for shackle type, porcelain vitreous white or brown insulator (for LT) working pressure in 1100 volts including galvnised mild steel straps of size 31X 3 mm and 12 mm dia insulator bolts, washers and nuts etc including dismantling unserviceable insulator of any size complete all as specified and directed.
M&L for pin type, insulator of size 100 mm height, 65 mm dia porcelain vitreous white or brown/green insulator (for LT) for working pressure in 1100 volts with one galvanised spindle and two galvanised iron washers and nut including dismantling unserviceable insulator of any size complete all as specified and directed.
M&L for loop type insulator of size 60x90 mm, clearence of hole 16 mm porcelain vitreous white or brown/green insulator (for LT) for working pressure 1100 volts including dismantling of unserviceable insulator of any size complete all as specified and directed.
M&L for errection in position including steel tubular swaged poles type 410 SP-31 (09.00 metres long) complete with cast iron base plate, final taper plug, bolts, nuts, screws and top cover all as specified and including the following:- (a) Excavation, PCC for foundation, returning filling and removing exevated shall be measured and paid seperately. (b) Painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer including preparation of surface including painting of 30cm wide blue bands 3 Nos. with synthetic enamel paint in alternate layer upto the height of 1.5m above plinth block. (c) M&L for writing letter or figures (Block, Roman, italic as Indian) with thick synthetic enamel paint of approved shade not exc height in numbering of pole all as directed.
S&F in replacement of stay assembly comprising of galvanised iron stay bow of size 40 cm X14 cm, 20 mm dia and 1800 mm long GI stay rod including excavation, PCC, GI nuts mild steel stay plate 300 mm X 300 mm X 6 mm, 2 No thimble, 50X6 mm flat iron stay clamp, steel stay wire 16 mm dia bolts, nuts and washers etc including taking down unserviceable stay assembly of any size complete all as shown in electrical plate No 1 of MES SSR 1991 Part 1 all as specified and directed.
Dismantling cross arms, bracings, supports, clamps and back plates from existing poles (other than dismantled poles) and pole structures complete all as specified and directed.
Fixing only cross arms, bracing, supports, clamps and back plate, obtained from demolition with and including new nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed and inclusive of applying one priming coat and two coats of synthetic enamel paint/aluminium paint including taking down corroded items of any type and size all as specified and directed.
S&F and stringing of OH electric ACSR conductor of any size fixing to insulator with necessary binding wire of suitable size including taking down unserviceable ACSR conductor of any type and size complete all as specified and directed. Note:- (i) 3% extra will be added to the weight for sagging. (ii) Binding and jointing will not be considered for measurement and all the jumper shall be fixed with minimum 6 pg clamps and the quoted rate shall deemed to be include in the unit rate quoted.
M&L for replacement of GI cradle guard hexagonal / rectangular with galvanised steel wire of 3.15 mm to 4 mm dia including taking down unserviceable GI craddle of any size and type complete all as specified and directed.
S&F of galvanised steel continuous earth wire of size 4.00 mm including taking down unserviceable GI earth wire of any size and type complete all as specified and directed.
S&F of galvanised stay strand wire of size 7/4 mm including taking down unserviceable stay wire of any size and type complete all as specified and directed.
Restringing of LT over head line conductor comprising of any size ACSR conductor / GI wire on existing pole after opening from insulator by taking out of binding wire and refixing the same with suitable size of binding wire upto permissible sag after restringing including cutting of tree branches and trimming of smaller branches of any size up to 2 metre each side of OH line which touch/ falling on the OH line without damaging of 4 wire (3 phase and neutral) span exc 25.00m but n. exc 35.00m complete all as specified and directed.
All as per Sl. item No. 22.00 here-in-before but 6 wire (3 phase, neutral and street light) span exc 25.00m but n. exc 35.00m.
M&L for GI tubing, light grade, 50mm dia with all necessary fittings, laid in trenches, under floor/road crossing, fixed on poles for cable protection fixed with the clamps made out of FI 25 x 3mm duly painted with two coats of aluminium paint over a coat of approved primer etc. including taking down old unserviceable any size and capacity of GI pipe complete all as specified and directed.
M&L for GI tubing, light grade, 80mm dia with all necessary fittings, laid in trenches, under floor/road crossing, fixed on poles for cable protection fixed with the clamps made out of FI 25 x 3mm duly painted with two coats of aluminium paint over a coat of approved primer etc. including taking down old unserviceable any size and capacity of GI pipe complete all as specified and directed.
M&L for PVC line spacer for LT over head line complete all as specified and directed. Note- Required T&P will be arranged by contractor no extra cost shall be paid.
M&L for replacement of GI cradle guard hexagonal / rectangular with galvanised steel wire of 3.15mm to 4 mm dia including taking down unserviceable GI craddle of any size and type complete all as specified and directed.
M&L for painting to steel tubular pole with aluminium enamel paint of 9.00 Mtr including cross arms, clamps any size and nuts, bolts etc with one coat of aluminium synthetic enamel paint including preparing the surfaces free from finish particalsand making the smooth surface and numbering on pole with black ground such as pole number and source of supply, painting with radium paint around the pole at width of 10cm, similar three rounds from 1.5 m GL top on circumferance of pole complete all as specified and directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to atleast 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
S&F in repairs on load change over switch 63 Amps 4 pole 415 volts 50 Hz with SS enclosure including taking down unserviceable one complete all as specified and directed.
S&F in repairs on load change over switch 100 Amps 4 pole 415 volts 50 Hz . with SS enclosure including taking down unserviceable one complete all as specified and directed.
S&F of offload change over switch in sheet metal enclosure, heavy duty, 200 Amps, four pole, 415 Volts AC, 50 Hz with side handle including connectins complete all as specified and directed.
S&F of off load change over switch in sheet metal enclosure, heavy duty, 320 Amps, four pole, 415 Volts AC, 50 Hz with side handle including connectins complete all as specified and directed.
S&F in replacement of single phase multi function electric energy LCD sub meter 5-30 Amp, 2 wire, 240V 50HZ complete all as specified and directed.
M&L in replacement of MCCB of follwoing sizes fixed with thermal and magnetic setting with extended terminals, replacemenr to LT panel/ feeder piller box including connecting lugs with busbar and including mounting arrengments i.e. screws, bolt, nut, washers including taking out old unserviceable complete all as specified and directed. Make-Legrand/Siemens/Schneider
(a) 400 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 36 KA
(b) 350 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 36 KA
(c) 200 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 36 KA
(d) 160 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 36 KA
(e) 100 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 16 KA
(f) 63 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 16 KA
Supply, laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in wall or passing through pipe, 1100 volts grade with XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor including making input and output connections with using suitable size of thimbles, lugs, and glands complete of following cross sectional area as under including taking down old unserviceable cable all as specified and directed.
(a) 120 Sqmm 3.5 Core
(b) 95 Sqmm 3.5 Core
(c) 70 Sqmm 3.5 Core
(d) 50 Sqmm 3.5 Core
(e) 35 Sqmm 3.5 Core
(f) 25 Sqmm 3.5 Core
(g) 16 Sqmm 4 Core
(h) 16 Sqmm 2 Core
S&F in replacement of 1100 volts grade heavy duty cable of size 10 Sqmm PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
M&L in replacment of 1100 Volts grade, heavy duty cable, PVC insulated copper cable, served with inner sheathing of PVC tape and overall PVC sheathed for hight mast light connection cicrular of size 4 Sqmm three core cable round type stranded conductor including taking down old unserviceable complete all as specified and directed.
M&L in replacment of 1100 Volts grade, heavy duty cable, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for street light connections cable flat or cicrular of size 6 Sqmm twin core cable stranded conductor including taking down old unserviceable complete all as specified and directed.
Supplying, jointing, testing straight through jointing kit heat shrinkable, out door type, suitable for LT 1100 volts grade cable of size 95 Sqmm to 120 Sqmm 3.5 core complete all as specified and directed.
Supplying, jointing, testing straight through jointing kit heat shrinkable, out door type, suitable for LT 1100 volts grade cable of size 50 Sqmm to 70 Sqmm 3.5 core complete all as specified and directed.
Supplying, jointing, testing straight through jointing kit heat shrinkable, out door type, suitable for LT 1100 volts grade cable of size 25 Sqmm to 35 Sqmm 3.5 core complete all as specified and directed.
Supplying, jointing, testing end termination jointing kit heat shrinkable, out door type, suitable for LT 1100 volts grade cable of size 70 sqmm to 120 sqmm 3.5 core complete all as specified and directed.
Supplying, jointing, testing end termination jointing kit heat shrinkable out door type, suitable for LT 1100 volts grade cable of size 25 sqmm to 50 sqmm 3.5 core complete all as specified and directed.
S&F mild steel sliding locking door bolt of size not less then 12 mm dia, 250 mm length bolt, stove enameled black with bright bolt with staple plate on LT panel doors (for locking of doors) with min six nuts, bolts and washers including drilling and fixing on site complete all as specified and directed.
S&F of butt hinges, heavy weight, cold rolled mild steel, 100mm size duly welded to doors of LT panel board, etc complete all as specified and directed.
S&F in repairs LED indication lamps (RGY) (set of three) complete all as specified and directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account whatsoever. 2. The cutting / trimming of tree branches shall be done min 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Supplying and spreading grass killer chemical all around to kill unwanted grass near or below the feeder panel and any E/M installation of cap 1 Litre bottle complete all as specified and directed.
Cutting of bituminous road/PCC hard standing/road/floor for laying of GI pipe upto 80mm dia (trench not more than 0.3m x 0.3m) for passing of cable including making good the disturbed surfaces all as per existing complete all as specified and directed. Note:-GI pipe shall be measured & paid separately under relevant items of this schedule.
M&L for servicing/repairing of APFC panel, any type and size upto 150 KVAR for making them functional, removing and cleaning of dusts, checking control wiring and connections, replacement of any damaged control wire, checking capacitors, tightening of all electrical connections and hardware, checking of metering devices, relays, etc, replacement of defective unserviceable parts to make the panel fuly functional complete all as specified and directed. Note:- Spares required shall be paid separately as supply only.
S&F in repairs and replacement of capacitor, metalized poly propylene heavy duty (MPPH), three phase, 415 volts and 50 Hz system for permissible non-linear load 15 % of 10 KVAR capacity to maintain power factor complete all as specified and directed.
S&F in repairs and replacement of capacitor, metalized poly propylene heavy duty (MPPH) three phase, 415 volts and 50 Hz system for permissible non-linear load 15% of 15 KVA,R capacity to maintain power factor complete all as specified and directed.
S&F of capacitor, metalized poly propylene heavy duty (MPPH), three phase, 415 volts and 50 Hz system for permissible non-linear load 15 % of 25 KVAR capacity to maintain power factor complete all as specified and directed.
M&L for repair of earthing pit cover with fixing of funnel of required size in PCC 1:2:4 type B1 (using 20mm graded stone aggregate) and RCC cover with frame as shown in electrical plate No-03 of SSR Part-I 2020 complete all as specified and directed.
M&L for earthing galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including galvanized steel strip 32 mm x 6 mm as earth lead upto equipment by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion and dismantling of existing earthing, complete all as specified and directed.
Labour only for attending day to day complaints for repairing of street light, security light, post top lantern of any size/ wattage including tighting loose electric connection, carbon deposition and any other minor defacts required for its smooth functioning at Taku area CPE Itarshi by deputing skilled and qualified electrician alongwith helper at any time of the day as per requirement complete all as specified and directed. Note:- (i) Complaint shall be done within 24 hrs after intimation or receiving reciept of complain slip by JE/ AGE otherwise penalty of Rs 250.00 per day per complaint will be levied on contractor. (ii) Complaints will be reported on daily basis with complaint register. (iii) Other minor items such as insulating tape, screws, small pieces of electrical cables PVC insulated copper multistranded conductor of size 2.5 Sqmm three core upto length of 1.5 m etc as required to attend the complaint is included in quoted rates.
S&F in repairs of LED driver suitable for 45-60 Watt existing LED security/street lights of any make and model complete all as specified and directed.
S&F in repairs of LED driver suitable for 70-100 Watt existing LED security/street lights of any make and model complete all as specified and directed.
S&F in repairs of LED driver suitable for 120-200 Watt existing LED flood light of any make and model complete all as specified and directed.
S&F of integral LED street light fitting of 45 watt, lumen not less than 5000 or 110 lm per watt, auto start efficiency not less than 85 % impact residence not less than IK -08, as per IS-10322 comprising of high pressure die cast aluminum hosing, heat resistant enclosed with glass cover in frame, IP-66 degree protection suitable for high efficient moulded lens operating voltage should be 170 Volt to 230 volts complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole, testing all as specified and directed.
S&F of integral LED street light fitting of 60 watt, lumen not less than 9000 or 125 lm per watt , auto start efficiency not less than 85 % impact residence not less than IK 08, as per IS 10322 comprising of high pressure die cast aluminum hosing, heat resistant enclosed with glass cover in frame, IP-66 degree protection suitable for high efficient moulded lens operating voltage should be 170 Volt to 230 Volts complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto require length on pole, testing all as specified and directed.
S&F of integral LED street light fitting of 70/72 watt, lumen not less than 7500 or 125 lm per watt, auto start efficiency not less than 85 % impact residence not less than IK 08, as per IS 10322 comprising of high pressure die cast aluminum hosing, heat resistant enclosed with glass cover in frame, IP-66 degree protection suitable for high efficient moulded lens operating voltage should be 170 Volt to 230 volts complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto require length on pole, testing all as specified and directed.
S&F of integral LED street light fitting of 90 watt, lumen not less than 11300 or 125 lm per watt, auto start efficiency not less than 85 % impact residence not less than IK 08, as per IS 10322 comprising of high pressure die cast aluminum hosing, heat resistant enclosed with glass cover in frame, IP-66 degree protection suitable for high efficient moulded lens operating voltage should be 170 Volt to 230 Volts complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole, testing all as specified and directed.
S&F of integral LED flood light following 100 Watt, 230 V AC high efficiency as per IS- 16107, IP-66 degree of protection comprising of epoxy powder coated housing enclosed with glass cover in frame, with impact and corrosion resistant complete with driver and lamp complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole, testing all as specified and directed.
S&F of integral LED flood light following 120 watt, 230 V AC high efficiency as per IS- 16107, IP-66 degree of protection comprising of epoxy powder coated housing enclosed with glass cover in frame, with impact and corrosion resistant complete with driver and lamp complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole, testing all as specified and directed.
S&F of integral LED flood light following 150 watt, 230 V AC high efficiency as per IS- 16107, IP-66 degree of protection comprising of epoxy powder coated housing enclosed with glass cover in frame, with impact and corrosion resistant complete with driver and lamp complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole, testing all as specified and directed. Note for item no 62 to 68:- Contractor shall produced manufacture test certificate and warrenty card for repair/replacement for 3 Years.
S&F in replacement for GFS polycarbonate thermoplastic oval shape weather proof junction boxes IP-65, with internal embedded polyurethane material gasket, IK-09 as per IEC 60695-2-11 for street lights size not less than 210 mmx155mmx102 mm with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating of rating 32 Amps for three phase and neutral mounted with locking arrangement and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and including provn for fixing 01 nos of single pole MCBs 6-32 amps,10KA all as specified and directed. Make: Hensel Cat part No-HENKFPJB-5/SINTEX
S&F in GI pipe 50 mm dia, medium grade, for mounting bracket bent to shape 1.75 meter length and fixing arrangement with two Nos of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over one coat of zinc oxide primer including taking down old unserviceable complete all as specified and directed.
S&F of aluminum lugs suitable for aluminum cable of size 16 Sqmm complete all as specified and directed.
S&F of aluminum lugs suitable for aluminum cable of size 35 Sqmm complete all as specified and directed.
S&F of aluminum lugs suitable for aluminum cable of size 50 Sqmm complete all as specified and directed.
S&F of aluminum lugs suitable for aluminum cable of size 70 Sqmm complete all as specified and directed.
S&F of aluminum lugs suitable for aluminum cable of size 95 Sqmm complete all as specified and directed.
S&F of aluminum lugs suitable for aluminum cable of size 120 Sqmm complete all as specified and directed.
S&F of timer switch (light sensor type nature switches), three phase plastic body degree of protection conforms to IP-54, operating illumination level for switching ON should be less than 60 lux for 30 seconds and for switching off must be greater than 10 lux for 30 seconds, multiple option switch for automatic and manual operations, capable to handle lightning load up to 8 KW, including MCB capacity 63 Amp conforms to IEC-60898 and IS-8828, power contactor capacity 40 Amp conforms to IEC 60947-4-1, IS 13947-4-1 completely enclosed with plastic body panel conforms to IP-54 degree of protection, after taking down the burned control gears and cleaning the existing mild steel panel board, duly painted with two coats of epoxy coloured spray paint including taking down the existing unserviceable timer switch of any capacity and removing the site complete all as specified and directed. Make : Model No SWADEEP- 02EC8KW1P of Kakatiya Energy systems Pvt Ltd, or equivalent make in Havells/ Legrand / ABB / Schneider
S&F in repairs synthetic rubber insulation mats for insulation for LT panels, transformer or DG Set of size 2mtr x1mtr x 2.5mm thick complete all as specified and directed. Make : Jyoti or equivalent make.
M&L for MCB, SP 6 A -32 Amp, Curve C, 240 V, 10 KA complete all as specified and directed.
S&F in repairs contactor 25 Amp, 3 Phase , 415 V, as per IS 13947-4-1, suitable for nature time switch model swadeep -02 complete all as specified and directed.
S&F in repairs contactor 16 Amp single Phase, 240 V, as per IS 13947-4-1, suitable for nature time switch model swadeep -02 complete all as specified and directed.
M&L for repairs of sensor of automatic street light control panel, single phase as per existing make on ground including testing for automatic functioning of street light on timer complete all as specified and directed.
M&L for repairs of sensor of automatic street light control panel, three phase as per existing make on ground including testing for automatic functioning of street light on timer complete all as specified and directed.
Dismantling and taking down solar light fitting of wattage 11 to 25 watt comple with solar panel assembly, solar battery assembly, light controller, fixture mounting bracket for checking serviveablity, repair of solar lights and testing including minor repair and painting of pole with 2 coats of existing paint to make fully serviceable complete all as specified and directed.
M&L for replacement of solar panel assembly with Light controller and MPPT charge controller suitable for 11 to 25 watt solar street light as per existing make including electric connection complete all as specified and directed.
M&L for replacement of solar light assembly suitable for 11 to 25 watt solar street light as per existing make including electric connection and GI bracket if required complete all as specified and directed.
M&L for replacement of solar light lithium ferro phosphate battery suitable for 11 to 25 watt solar street light as per existing make including electric connection complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead of 32x6 mm galvanised iron strip buried in ground or fixed to wall complete all as specified and diirected.
S&F in replacement cable pvc insulated and pvc sheathed of size 2.5 Sqmm three core stranded aluminium conductor complete all as specified and directed.
M&L for maintenance free battery 12 V 180 AH tubular type initial charged complete all as specified and directed. Make- Exide/Tata
S&F of integral solar light 20 watt, highly efficient not less than 90 %, degree of protection IP-65 with built in high efficiency solar panel approved by MNRE, LED highly brightness high power light and long life lithium iron battery including BIS certified rechargeable cell with display showing for battery charging full charge, low voltage with different colour LED lamp with high efficiency microprocessor based charge controller and motion sensor. The has automatic dusk to down operation. The luminaire shall have specially designed pole mounting piece that enabled lateral as well as post top mounting and installation at varying tilts from 0 to 15 degree for optimal light distribution, including mounting pole of size 6 mtr long and earth, PCC work and electric cable for electric connection and any other parts for smooth functioning of solar lights testing complete all as specified and directed. Make- Philips /Havells/Orient
Labour only for attending day to day complain of internal electrification such as no light , unserviseable tube lights, bulk head fittings, recess lights, mirror lights, building security lights, LED bulbs, switches, sockets, lamp holder, fan regulator, bell push, ceiling rose , plug top, MCBs for minor reparing/rectified including regarging flame proof light and fixture and making functional by skilled trades man with necessary T&P as required at site to complete job with stuiplated time and user satifaction incl small piece of copper conductor single core multistranded up to 1 Mtr of size up to 4 Sqmm complete all as specified and directed at site. Note : - (i) Maximum 05 Nos of complaints shall be done within 24 hrs after intimation or receiving reciept of complain slip by JE/ AGE otherwise penalty of Rs 250.00 per day will be levied on contractor. (ii) Complaints will be reported on daily basis with complaint register. (iii) Other minor items such as insulating tape, screws, small pieces of electrical cables PVC insulated copper multistranded conductor of size 2.5 Sqmm three core upto length of 1.5 m etc as required to attend the complaint is included in quoted rates. (iv) The quoted rate deems to exclude for all chasing of wall and plaster for making good of disturbed surfaces as per existing colour on wall.
Taking down carefully aluminium / copper point wiring with surface/ concealed PVC conduit or wooden batten ( light, fan, socket, bell or power ) including sunk in cast iron / pressed steel terminal boxes except fitting such as switches, ceiling roses, lamp holders, sockets, regulators, call bells, light fittings of any sketch etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 volts grade ISI marked drawn into and including concealed rigid non mettalic PVC conduit, medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall and making and maching the existing surface with 2.8 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame, concealed in wall or 1.5 sq mm multistranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly for One light point/fan point controlled by one switch complete all as specified and directed.
All as per ser item no 95.00 here-in-before but One socket outlet 5 Amps controlled by one switch on the same board.
All as per ser item no 95.00 here-in-before but One socket outlet 5 Amps controlled by one switch on independent board.
All as per ser item no 95.00 here-in-before but One bell / buzzer controlled by one bell push.
All as per ser item no 95.00 here-in-before but One light point controlled by two way switch.
All as per item No. 95.00 here-in-before but with 2.5 Sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 Sq mm PVC insulated multistranded copper conductor cable as continuous earth wire complete all as specified and directed.
M&L for point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 volts grade ISI marked drawn into and including surface PVC casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 2.8 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etc and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire for One light point/fan point controlled by one switch complete all as specified and directed.
All as per ser item no 101.00 here-in-before but One socket outlet 5 Amps controlled by one switch on the same board.
All as per ser item no 101.00 here-in-before but One socket outlet 5 Amps controlled by one switch on independent board.
All as per ser item no 101.00 here-in-before but One bell / buzzer controlled by one bell push.
All as per ser item no 101.00 here-in-before but One light point controlled by two way switch.
All as per item No. 101.00 here-in-before but with 2.5 Sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 Sq mm PVC insulated multi stranded copper conductor cable as continuous earth wire complete all as specified and directed.
M&L in repairs for sub main wiring with two single core 4.0 sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable including rigid non metallic PVC conduit medium grade, ISI marked, 20 mm dia for sub main wiring including 4.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/recess and making good to the disturbed surfaces to match the existing surfaces including taking down existing unserviceable sub main of any type and size complete all as specified and directed. Note:- Two runs of 4.0 Sq mm copper conductor cable, one run of 4.0 Sq mm copper conductor and one run of PVC conduit will be measured as one unit.
M&L in repairs for sub main wiring with two single core 6.0 Sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable including rigid non metallic PVC conduit medium grade, ISI marked, 20 mm dia for sub main wiring including 6.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/recess and making good to the disturbed surfaces to match the existing surfaces including taking down existing unserviceable sub main of any type and size complete all as specified and directed. Note:- Two runs of 6.0 Sqmm copper conductor cable, one run of 6.0 Sq mm copper conductor and one run of PVC conduit will be measured as one unit.
M&L for switch piano flush type pole one way 5 Amps, 240 V complete all as specified and directed.
M&L for socket outlet, 3 pin 5 Amps, 240 V flush type complete all as specified and directed.
M&L for piano flush type, 5 Amps single pole two way complete all as specified and directed.
M&L for switch piano flush type, pole one way 15 Amps, 240 V complete all as specified and directed.
M&L for socket outlet flush type multi purpose 2 in 1, 3 pin 5 and 15 Amp, 230 Volts complete all as specified and directed.
M&L for ceiling rose surface bakelight two to three terminal complete all as specified and directed.
M&L for lamp holder, insulated body, with back plate for batten fitting complete all as specified and directed.
S&F in repairs switch socket combination outlet flush type multi purpose 2 in 1, 3 pin 5 and 15 Amp, 230 Volts complete all as specified and directed.
S&F in repairs and replacement of ding dong bell AC, 240 Volts single pole complete all as specified and directed.
M&L for electronic step type fan regulator/mini switch type dimmer 120/280 watt capacity including connecting up complete all as specified and directed.
S&F of 09 watt LED bulb, in white colour with maximum Lumen output (850 lm) and colour temp 3000 K, complete all as specified and directed.
S&F of 1 x 20 watt LED tube light fitting polycarbonated housing prewired with all accessories and including LED tube rod 20 watt 4 feet long inlcuding connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 Sqmm complete all as specified and directed.
S&F of LED light fitting mirror type polycarbonated housing with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repairs existing make modular switch 1 way 6A, 240 Volt, 1 module complete all as specified and directed.
S&F in repairs existing make modular switch 1 way 16A, 240 volt, 1 module complete all as specified and directed.
S&F in repairs existing make modular bell push 10A, 1 module complete all as specified and directed.
S&F in repairs existing make modular socket, 6A - 5 pin combined, 2 module complete all as specified and directed.
S&F in repairs existing make modular socket 6A/16A - 2/3 pin combined, 2 module complete all as specified and directed.
S&F in repairs existing make modular fan step regulator 120W, 240 Volts 1/2 module complete all as specified and directed.
S&F in repairs 3 Pin, plug top 5/6 Amp, 220 volt complete all as specified and directed.
S&F in repairs 3 Pin, plug top 15/16 Amp, 220 volt complete all as specified and directed.
S&F for replacement of unserviceable wire of size 1.5 sqmm ISI marked single core FRLSH insulated multistranded copper conductor for working voltage 1100 volts complete all as specified and directed.
All as per item No. 130.00 here-in-before but of size 2.5 sqmm.
All as per item No. 130.00 here-in-before but of size 4.0 sqmm.
S&F in replacement of PVC insulated multistranded aluminium conductor twin core of size 6 sq mm, 1100 volts grade heavy duty service cable, served with inner sheathing of PVC tape and over all PVC sheathed in service connections complete all as specified and directed.
S&F in repairs and replacement of building security light fitting LED 35 watt energy saving & environmental friendly long life versatile pressure die-cast aluminium IP-66 roadway luminaire with high power LED as light source with toughened glass and impact resistance PF IK-08 and GI pipe 40 mm dia, light grade, for mounting bracket bent to shape 1.50 rm and fixing arrangement with two nos of mild steel clamps set, nut bolts, washers of suitable size and fixing on wall/pole including taking down unserviceable fitting complete all as specified and directed.
S&F of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repairs and replacement of recess mounted adjustable for LED 15W Watt down lights made of extruded aluminium housing and high power LED light source with driver clear diffuser with separate electronic driver with accessories complete all as specified and directed as per site requirement. Note:- Ceiling cutout size 180mm dia
S&F in repairs and replacement of surface LED 15W down lighter with white powder coated aluminium housing with integrated electronic driver with accessories complete all as specified and directed as per site requirement.
M&L repairs and repacement of HEXA 10 W, IP-66 bulk head luminaries, with lamp holders, including one 1X 10W LED etc with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ including taking down unserviceable fitting complete all as specified and as directed.
S&F of post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant with driver and lamp complete all as specified and directed.
S&F in repairs and replacement of sheet metal enclosure MCB DB, 4 way, TPN 415 Volts including taking down unserviceable fitting complete all as specified and directed.
S&F in repairs of sheet metal enclosures for SPN DB's 240 volts, factory made, double doo,r flush type, IP-43 protection and all as per IS-8623, made from sheet metal 8 way 200 amps rated bus bar to be fixed with wall all accessories including taking down unserviceable fitting complete all as specified and as directed.
S&F in repairs and replacement of sheet metal enclosure SPN with a two pin and earth plug and socket with and including one single pole MCB 20 Amps 240 volts including taking down unserviceable fitting complete all as specified and directed.
S&F in repairs and replacement MCB, SPN, 240 volts 16 to 40 Amps including taking down unserviceable fitting complete all as specified and directed.
S&F in repairs and replacement MCB, TPN 63 Amp 440 Volts including taking down unserviceable fitting complete all as specified and directed.
S&F in repairs and replacement MCB, double pole 240 Volts, 40 Amps complete all as specified and directed. Note for item No 143.00 to 145.00 :- MCB shall be of 10 KA breaking capacity having 'C' characteristics as per IS-8828 with air circulating channels, bicontact terminals, dual position DIN rail clamps with IP-20 degree of protection, insulating sliding shutter, wiring cable shall be connected to MCB's with suitable lugs (Copper lugs for copper cable and aluminium lugs for aluminium cable)
M&L for measurment of earth resistivity test with earth tester and T&P required at site by deploying sufficient manpower by the contractor and made entry in register and put up to conerned JE and Engr-in-Charge.
M&L for earthing complete with glavanised steel earth plate elactrode 600x600x6.0 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground levels) with top edge of the plate not less than 1.5 mtr deep below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nut, bolt, check nut and washer of galvanised iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of charcoal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation and earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Pt-I 1991 print and as directed.
Taking down carefully AC ceiling fan 1200mm/1400mm sweep, exhaust fan 300mm to 450mm sweep and wall mounted bracket fan 300/450mm sweep from their position complete for servicing such as removing dust and dirt from fan motor, washing blades with detergent powder including greasing to bearing, checking & replacing worn out screws with spring washers, rubber befit washers of fan blades, fan motor body, spilt pin/screw for fan down rod/check nuts as required for different makes of ceiling/exhaust fans to put fans to smooth and satisfactory working and refixing ceiling fan/exhaust fan after executing necessary servicing to their position connecting to electric system with suitable size of cable and testing, complete all as specified and directed. Note : Rates quoted by contractor shall deemed to be inclusive all minor items and no extra payment shall be admissible except for the items which are to be replaced which shall be measured and paid separately under respective item of Schedule 'A'.
M&L for preparation of old painted surfaces of ceiling fan, exhaust fan and wall mounting fan by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and painting by applying synthetic enamelled first quality paint using spray gun in situ including filling cavities with filler and marking Srl No SM No / MES No with black paint complete all as specified and directed.
M&L for rewinding of AC ceiling fan, 230 volts, 50 Hz, 1200mm/1400mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified and directed.
M&L for rewinding of exhaust fan/wall mounted fan, 230 volts, 50 Hz, 300/450mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified and directed.
S&F of ball bearing 6202/6203 in replacement suitable for AC ceiling fan of 1200/1400mm sweep/ exhaust fan/ air circulation fan of any make to replace the unserviceable bearing including greasing as required, complete all as specified and directed.
S&F in replacement capacitor, 4/5 mfd 230 volts, AC, 50 Hz, complete all as specified and directed.
S&F in replacement capacitor, 2.5 mfd 230 volts, AC, 50 Hz, complete all as specified and directed.
S&F in repairs of split pin with hook, rubber and nut bolt of suitable for ceiling fan/exhaust fan of any sweep and make complete all as specified and directed.
S&F in repairs of shaft of approved quality for ceiling fan/exhaust fan any make, type and size complete all as specified and directed.
S&F in repairs of self lubricating bush of gun metal as per ceiling fan/exhaust fan complete all as specified and directed.
S&F in replacement fan canopy complete all as specified and directed.
S&F in repairs and replacement of hanging rod 1ft/2 ft complete all as specified and directed.
S&F in repairs and replacement of fan blade 1200/1400 mm complete all as specified and directed.
Supply only of PVC insulated FRLS, unsheathed three core copper flexible cable of size 1.5 sqmm including connection complete all as specified and directed.
Taking down carefully Geyser of capacity 25/35 ltrs from its position for repair/servicing such as removal of dust, checking, replacing worn out parts, rubber etc, re-assembling at its position after repair, testing & commissioning & connecting to electric system with suitable size cable, complete all as specified and directed. Note : Rates quoted by contractor shall deemed to be inclusive all minor items and no extra payment shall be admissible except for the items which are to be replaced which shall be measured and paid separately under respective item of Schedule 'A'.
S&F of galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete including taking down all as specified and directed.
S&F of galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete including taking down all as specified and directed.
S&F of geyser tank of capacity 25 ltrs, complete all as specified and directed.
S&F of geyser tank of capacity 35 ltrs, complete all as specified and directed.
S&F of heating element for geyser, 1500 watt, ISI marked, round type, complete all as specified and directed.
S&F of heating element for geyser, 2000 watt, ISI marked,round type, complete all as specified and directed.
S&F of heating element for geyser, 1500 watt, ISI marked, triangle type, complete all as specified and directed.
S&F of heating element for geyser, 2000 watt, ISI marked, triangle type, complete all as specified and directed.
S&F of thermostat suitable for geyser of any capacity, complete all as specified and directed.
S&F of angle stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repair, complete all as specifed and directed.
Supply & fixing Bib tap, 15mm bore, fancy type, chromium plated , cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repair, complete all as specified & directed.
S&F of stainless steel connection 15mm dia, 900mm long with brass CP, nuts and washers at both ends for hot water and cold water, fixed in repair, complete all as specified and directed.
Taking down/out deep freezer/refrigerator transporting to contractor's workshop for carrying out repairs, taking out assembly, welding/brazing after detecting the leakage, as mentioned in respective items of schedule including transporting back after repair, re-fixing at site, making it functional after replacement of worn out nuts, bolts, washer etc. including re-connecting electrical connection and testing, complete all as specified and directed. Note :- Cost of material and labour for providing new items shall be measured and paid for separately under relevant items of Sch 'A'.
Taking down/out water cooler of 40/80 ltrs and 60/120 ltr capacity transporting to approved workshop for carrying out repairs, taking out assembly, welding/brazing after detecting the leakage, as mentioned in respective items of schedule including transporting back after repair, refixing at site, making it functional after replacement of worn out nuts, bolts, washer etc. including re-connecting electrical connection testing complete all as specified and directed. Note :- Cost of material and labour for providing new items shall be measured and paid for separately under relevant items of Sch 'A'.
M&L for preparation of old painted surfaces by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and repainting by applying two coats of synthetic enamelled first quality paint using spray gun over over one coat of red oxide zinc chrome primer and marking Srl No SM No / MES No with black paint of Deep Freezer/Refrigerator/water cooler of capacity up to 320 Litres complete all as specified and directed.
S&F in replacement of following unserviceable items of deep freezer/refrigerator of 300/310/320 litres as required at site including testing of the same complete all as specified & directed :-
(a) MS condensing coil with fixing arrangement for 300/310/320 litres capacity complete with gas charging.
(b) Over load protector.
(c ) Thermostat switch (Auto defrost).
(d) Temp control knob with defrost push button.
(e) Electrical lamp pin/threaded type 15 watt, 240 volts AC supply.
(f) PVC ice tray of superior quality.
(g) Relay as per existing.
Supplying, fixing and testing new compressor, single phase, 240 Volts, AC supply in replacement including cost of rubber bushes, bolts, nuts washers, copper tubing capillary tube, dryer filter terminal cover, thimbles, electrical wiring oil and gas charging (R-134 or as recommended by manufacture) and testing complete for the following including transportion etc :-
(a) Compressor of Deepfreezer/Refrigerator of cap 300/310 Ltr.
(b) Compressor of Water Cooler of capacaity 300/310 Litres.
S&F in replacement of following unserviceable items by opening of water cooler of 40/80 or 60/120 Ltrs capacity frost free for following replacement of unserviceable accessories and refixing, connecting and testing complete all as specified and directed :-
(a) Copper Condensing coil complete with fixing arrangement.
(b) Fan motor 1/2 HP, 240 volts, single phase AC supply.
(c ) Aluminium Blade for fan motor complete blower.
(d) Thermostat.
(e) Relay as per existing make.
(f) Over load protector.
(g) Float Valve brass 15 MM bore.
(h) Push type tap 15mm bore, brass chromium plated
S&F of filing/charging of following water collers/deep freezer with refrigerant R-22A/R-134 or as recommended by manufacturer including flushing out oil, vacuming, top up oil, brazing, leak detection, testing etc for following cooling appliances including replacement of capillary tube and dryer filter :- Note:-. The type of refrigerant gas shall be charged as per manufacturer recommendation.
(a) Water cooler 60/120 litres capacity.
(b) Deep Freezer/Refrigerator of capacity up to 320 Litres.
S&F in replacement of water lifting pump (water immersed) for desert cooler with model - HM - 09, 240 volts, 50 Hz, 40 watts, 1.5 metre max head and output 800 LPH complete all as specified and directed.
S&F in replacement of khas pads/wood wool pad of required size for desert cooler of any make complete all as specified and directed.
S&F in repairs of blower motor, 230 volts, single phase, 50 Hz, suitable for desert cooler /Exhaust fan size 350/450 mm as per site requirement including kit consists of mounting clamps, blades, speed contol switch, nut, bolts and washers complete all as specified and directed.
S&F in replacement of exhaust fan louver of any size complete all as specified and directed.
S&F in replacement/repairs of voltage stabilizer of capacity 5 KVA installing and testing complete all as specified and directed.
Taking down defective split/window AC of 1.5 Ton capacity from any height and any places for repair and refixing at its original place after replacement of defective/wornout parts and making serviceable, complete all as specified and directed. Note:- Worn out spares parts required for making AC serviceable/functional shall be measured and paid separately under appropriate item as 'Supply only'.
(a) Supply only fan motor for 1.5 ton AC.
(b) Supply only AC compressor for 1.5 ton AC.
(c ) Supply and charging gas 22 R for 1.5 ton AC.
(d) Supply only AC copper pipe of size 8mm and 15 mm for 1.5 ton AC.
(e) Supply only 45 Mfd capacitor for 1.5 ton AC. Make.
(f) Supply only contactor, single phase, 30 Amp for 1.5 ton AC.
(g) Supply only fan belt for 1.5 Ton AC.
(h) Supply only printed circuit board of split AC/Window AC 1.5 ton
(j) Over load protector.
Maintenance for operationaly fit of RO based aqua guard installed for water cooler, with replacement of candle, replacement of membrane, replacement of pree filter candle, replacement of diaphragm pump 24 volt DC and open flow minimum 2.0 Ltr/min checking of AC supply circuitary of aqua guard and made functional, replacement of step down transformer 230 volt to 12/24 volts, as per sample, including servicig of RO complete all as specified and directed at site.
S&F in repairs for solar heaters of various capacities of heating element of capacity 2 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½” complete all as specified.
S&F in repairs for solar heaters of various capacities of heating element of capacity 1.5 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½” complete all as specified.
S&F in repairs for solar heaters of various capacities of glycol (Anti freezing solution) for filling in copper tubes complete all as specified.
S&F in repairs for solar heaters of various capacities of dead flange with nut, bolts and washers complete all as specified.
S&F in repairs for solar heaters of various capacities of float valve assembly 15mm dia complete all as specified.
S&F in repairs for solar heaters of various capacities of thermostat suitable for solar heater complete all as specified
S&F in repairs for solar heaters of various capacities of hot water steel tank non stick 2mm thick with ceramic lining of capacity 500 Ltrs each including making necessary connections complete all as specified.
Deduct Schedule of credit (calculation will be done off line) Rs. 90779.00
TANUJ CONST. CO.
Dashmesh Enterprises
pyarelal galar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .