| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.7 LAccepted-AOC | ₹49.7 L | L1 | Accepted-AOC Accept |
| 2 | L2₹59.3 LRejected-Finance | ₹59.3 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹60.2 LRejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹60.2 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹62.1 LRejected-Finance | ₹62.1 L | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹63.3 LRejected-Finance NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹63.3 L | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | M/s Kamal Electrical L4 | SWASTHIK ENGINEERING WORKS L1 | M/s Ramesh Lal L3 | ANITA VARMA ENTERPRISES L2 | M/s Sriya Enterprises L5 | M/s K Moorthi L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down of old UG Cable of any size/core and any type complete from trenches/cable duct/on wall/roof carefully, identifying for faults, dismantling unserviceable cable and saggregating serviceable cable for reuse all as specified and directed. | 1,055 | RM | 55 ₹58,025 | 20 ₹21,100 | 40 ₹42,200 | 25 ₹26,375 | 35 ₹36,925 | 80 ₹84,400 |
| 2.00Suppy and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, PVC insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: Earth work/HDPE pipe/straight through joints if required will be measured and paid separately.The rates should be includs in Cable lugs, Cable Gland and necessary insulation taping. | |||||||||
| 2.01 | (a) 4 Core 6 Sqmm | 155 | RM | 350 ₹54,250 | 220 ₹34,100 | 262 ₹40,610 | 259 ₹40,145 | 275 ₹42,625 | 310 ₹48,050 |
| 2.02 | (a) 4 Core 10 Sqmm | 190 | RM | 328 ₹62,320 | 240 ₹45,600 | 325 ₹61,750 | 295 ₹56,050 | 341 ₹64,790 | 352 ₹66,880 |
| 2.03 | (b) 4 Core 16 Sqmm | 270 | RM | 420 ₹1,13,400 | 260 ₹70,200 | 366 ₹98,820 | 395 ₹1,06,650 | 410 ₹1,10,700 | 397 ₹1,07,190 |
| 2.04 | (c) 3.5 Core 25 Sqmm | 260 | RM | 700 ₹1,82,000 | 340 ₹88,400 | 429 ₹1,11,540 | 465 ₹1,20,900 | 452 ₹1,17,520 | 465 ₹1,20,900 |
| 2.05 | (c) 3.5 Core 35 Sqmm | 180 | RM | 477 ₹85,860 | 360 ₹64,800 | 471 ₹84,780 | 466 ₹83,880 | 496 ₹89,280 | 511 ₹91,980 |
| 3.00 | Supply & Laying in repair of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge Make : REX POLYEXTRUSION LTD, Prince or its equivalent as approved. | 1,220 | RM | 140 ₹1,70,800 | 90 ₹1,09,800 | 115 ₹1,40,300 | 125 ₹1,52,500 | 121 ₹1,47,620 | 125 ₹1,52,500 |
| 4.00 | Relaying/ Rerouting old serviceable UG cable of size 10 to 25 Sqmm any core retrieved from item No above in trench/pipe/DWC pipes /on wall /cable duct with necessary saddles/clamps of suitable size complete all as directed. Note: Earth work, DWC pipe/GI pipe will be measured and paid separately | 220 | RM | 65 ₹14,300 | 45 ₹9,900 | 52 ₹11,440 | 60 ₹13,200 | 55 ₹12,100 | 62 ₹13,640 |
| 5.00 | S&F GI pipe of medium grade 40 mm dia all fitting fixture for fixing with wall and road crossing etc. complete all as specified and as directed by Engineer-in-Charge | 24 | RM | 529 ₹12,696 | 1,200 ₹28,800 | 523 ₹12,552 | 535 ₹12,840 | 551 ₹13,224 | 625 ₹15,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
4 Oct 2025, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8635/E8 SPECIAL REPAIR FOR REPLACEMENT OF OLD RUSTED POLES / DEFECTIVE RCC / PCC POLES OF ILLUMINATION SYSTEM WITH CONNECTED ACCESSORIES AT AJAY BAUGH AREA, JAYANT PARK, ASHWINI NAGAR AND OTHER OFFICERS MD ACCN AREA AN PROVN OF SPLIT AC FOR NCN SWITH
2025_MES_730612_1
8635/E8
Open Tender
Civil Works
180 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
13 documents required · 13 mandatory
₹500
Yes
GE, Minniebay
₹98,000
Yes
10 Jan 2026
13 Sept 2025
6 Oct 2025
13 Sept 2025
4 Oct 2025
27 Sept 2025
Amount
Taking down of old UG Cable of any size/core and any type complete from trenches/cable duct/on wall/roof carefully, identifying for faults, dismantling unserviceable cable and saggregating serviceable cable for reuse all as specified and directed.
Suppy and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, PVC insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: Earth work/HDPE pipe/straight through joints if required will be measured and paid separately.The rates should be includs in Cable lugs, Cable Gland and necessary insulation taping.
(a) 4 Core 6 Sqmm
(a) 4 Core 10 Sqmm
(b) 4 Core 16 Sqmm
(c) 3.5 Core 25 Sqmm
(c) 3.5 Core 35 Sqmm
Supply & Laying in repair of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge Make : REX POLYEXTRUSION LTD, Prince or its equivalent as approved.
Relaying/ Rerouting old serviceable UG cable of size 10 to 25 Sqmm any core retrieved from item No above in trench/pipe/DWC pipes /on wall /cable duct with necessary saddles/clamps of suitable size complete all as directed. Note: Earth work, DWC pipe/GI pipe will be measured and paid separately
S&F GI pipe of medium grade 40 mm dia all fitting fixture for fixing with wall and road crossing etc. complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-Charge
All as per item No 6.00 here in before but exc 1.5 mtr or part there of in depth beyond 1.5 mtr depth.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -charge.
M&L for road cutting, removing of material , returning filling and pcc 1:2:4 for laying of LT UG cable /Galvanised Iron Pipe/DWC Pipe all as specified and as directed by Engineer-in -charge.
S & F cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 25 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge. .Make : DENSON / M Seal / RAYCHEM
Dismantling old RCC / rusted poles including PCC and supply & erect minimum 11 mtr height above GL / foundation made out of Hot dip Galvanized single section octogonal pole with foundation base plate of size 290x290x17 mm, foundation bolts 04 Nos of size 29 x 830/840 mm,with signle type arm bracket 1500 mm long, the pole shaft shall be tapered with single longitudinal welding and door opening for cable with 01 No MCB SP 6 Amp and 32 Amp connector and 03 run of 1.5 sqmm PVC wire for connecting street light fitting from MB complete all as specified and as directed by Engineer-in -charge. Note : Earth work, cement concrete in foundation, coping etc will be measured and paid seperately under relevant item.
Dismantling old RCC / rusted poles including PCC and supply & erect minimum 7 mtr height above GL / foundation made out of Hot dip Galvanized single section octogonal pole with foundation base plate of size 250x250x16 mm, foundation bolts 04 Nos of size 24 x 700/750 mm,with signle type arm bracket 1500 mm long, the pole shaft shall be tapered with single longitudinal welding and door opening for cable with 01 No MCB SP 6 Amp and 32 Amp connector and 03 run of 1.5 sqmm PVC wire for connecting street light fitting from MB complete all as specified and as directed by Engineer-in -charge. Note : Earth work, cement concrete in foundation, coping etc will be measured and paid seperately under relevant item.
Reinforced cement concrete (design mix) Foundations M-30 Grade, including rafts, footings, foundation beams, plinth beams, bases for columns, etc,basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr in charge.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation of complete all as specified and as directed by Engineer-in -charge
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work of complete all as specified and as directed by Engineer-in -charge
M&L for TMT bars from but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for foundation work complete all as specified and as directed by Engr in charge.
M&L bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required,not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.all as specified and as directed by Engineer-in -charge.
Supply GI clamp made out of 50x6 mm flat iron of suitable size for steel tabular poles all as specified and directed by Engineer-in-charge.
S&F PVC copper cable insulated shealthed of size 1.5sqmm x 3 core complete all as specified and as directed by engineer in charge. Make- Havells or equivalent.
Supplying and laying on wall/ on pole of CPVC pipes outer diameter 20mm SDR 13.5 pipes & plain CPVC SDR 11 fittings complete all as specified and as directed including dismantling old one.
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type), IP 54 with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
Supply & fixing IP 65/66 thermoplastic-polycarbonate cable junction box of size 205X255X112mm with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of Two nos of GI calmp of size 25X3 mm including 40Amps connector, lugs and equivalent MCB complete all as directed.
S&F LED street light fittings warm white comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 10800 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 90 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,3000K,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F LED street light warm white fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 8400 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 70 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,3000K,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F LED street light warm white fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 7200 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 60 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,3000K,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F LED street light warm white fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 5400 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 45 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F LED street light warm white fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 3000 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 25 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge Notes for Item Nos:-42 to 46: (a) GI pipe bracket if required shall be measured and paid separately
S&F in replacement energy efficient post top light fitting on wall/gate 360 degree indirect light with IP 65 protection high quality integrated LEDs assuring soothing warm white light all night long LED 25 W with THD less than 10%.CRI>80,P.F>0.9,IK>08,black case aluminium including all necessary wiring LED bulb,clamps,nut and bolts mounting accessories etc and providing connection complete all as specified and as directed by Engineer in charge
S&F in replacement energy efficient LED Garden light fitting 360 degree indirect light with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long LED 10 W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed by Engineer-in-Charge.
Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 120 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 18000 lumens and suitable wattage for efficiency not less than 120 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 24000 lumens and suitable wattage for efficiency not less than 120 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
S&F energy efficient LED bollard light fitting with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long 12W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed by Engineer-in-Charge.
Supply & fixing LED Rope light 18 mtr comprising of transparent silicon coating,tricolour specified as orange, white, green colour 240V, 50Hz suitable wattage for efficiency not less than 6W/mtr , having secondary optics, min wattage 108 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, SPD of capacity 10 KV etc incl fixing accessories on wall, poles etc and 2 extra set of strip connector and 1 set of driver, necessary clamps etc complete and testing on completion all as specified and as directed. .
Supply fixing connection and testing of MCB SP 6-32Amps of complete all as specified and as directed. Make : Legrand / L&T/Schiender.
Supply and fixing Service wire Al Conductor Weather Proof 10 Sqmm 2core complete all as specified and as directed by Engineer-in -charge.
Supply and fix Digital Timer with Digital time switch ,contactor pre wired Distribution Board complete time lite 40A 3 Pole 415 V complete as specifed and directed by Engineer-in -charge.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth wire 4mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 2.0 TR including required gas charging of complete all as specified and as directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 1.5 TR including required gas charging of complete all as specified and as directed. Note item No 40.00 & 41.00:- (a) The cost of remote with batteries, compressor oil, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate. (b) Drilling of the wall should be done by core cutting machine. (c) Quoted rate inclusive of copper piping upto 3 mtr and refrigerant gas upto 3 mtr piping. (d) Additional cost of copper tubing (>3 mtr), refrigerant gas (>3 mtr) & bracket for mounting outdoor unit shall be measured and paid separately.
S&F of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete all as specified and as direted.
M&L for Air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete all as specified and as directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and as directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 3.0 KVA complete all as specified and as directed.
M&L for submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two run of 4 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification and one run of 4 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed. Note : (i) Three run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length. (ii) The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping of suitable size as per site requirement.
Supply and fixing Rigid non-metallic PVC conduit 25 mm dia inclusive of all fittings and fixing accessories complete all as specified and as directed.
Supply and charging refrigerant gas environmental friendly refrigerant gas as per OEM design for gas charging complete.
Supply and fixing of Copper tubing of size 1/2" or 1/4" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
Supply and fixing of Copper tubing of size 3/8" or 5/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
ANITA VARMA ENTERPRISES (BID ID -3441080)
M/s Ramesh Lal (BID ID -3441853)
M/s Kamal Electrical (BID ID -3440104)
M/s Sriya Enterprises (BID ID -3442065)
M/s K Moorthi (BID ID -3442255)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid