Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-Finance | L1 | Accepted-Finance eligible | |
| 2 | l2₹15.2 L+₹83,511 (5.83%)Accepted-Finance 632 318 VIMAL NAGAR CHINHAT LUCKNOW LUCKNOW LUCKNOW UTTAR PRADESH 227105 | 227105 | l2 | Accepted-Finance eligible | |
| 3 | l3₹18.3 L+₹4.0 L (27.9%)Accepted-Finance | l3 | Accepted-Finance eligible |
Tender Value
₹15.4 L
EMD Value
₹30,828
Closing Date
24 Oct 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(E)
Room No 208 TE Bldg Sec 34 Chandigarh
23/EE/E/BSNL/ED/CHD/23-24
2023_BSNL_170735_1
23/EE/E/BSNL/ED/CHD/2023-24
Open Tender
Electrical Works
Item Rate
30 days
TE 49
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO ( Cash)
₹30,828
30 Oct 2023
13 Oct 2023
25 Oct 2023
13 Oct 2023
24 Oct 2023
13 Oct 2023
Amount
Replacement of old defective compressor with new Sealed compressor in the existing conventional Package AC / HPAC unit including dismantling of faulty compressor, cutting refrigerant piping, brazing & making necessary addition/ alteration i/c proper mounting on base plate, connection of suction and discharge lines etc as reqd. (M/s Emerson/ Tecumseh/ SS make ) (NOTE- The firm shall submit test certificate or documentary proof towards purchase of New/OEM factory repaired compressor.) The defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory)
2 TR scroll for HPAC ( Copeland make Model ZR28K3-PFJ-522)
2 TR scroll for HPAC ( Copeland make Model ZR28K3-PFJ-522)
Supplying and charging refrigerant R-22 in the refrigerant circuit of existing 7.0 TR AC units as per the standard procedures and as per the directions of engineer in charge comp. as reqd.
7.0 TR AC units
2.0 TR AC units
Supplying and charging refrigerant R-22 (topup) in the refrigerant circuit of existing 7.0 TR AC units as per the standard procedures and as per the directions of engineer in charge comp. as reqd.
Supplying and fixing of condenser motor for existing 2 TR HPAC units complete as reqd.
Supplying and installation of following material for repairing & attending break down complaints of 7TR conventional/ HPAC Package AC units/ Electrical Control Panel i/c dismantling, connection, fixing & testing etc as required. (NOTE- The firm shall submit test certificate or documentary proof towards purchase of New ) The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory.
Condenser motor for Conventional AC Units
Condenser fan Blades
Thermostat (M/s Danfoss/indfoss/Arvind/SS make )
Dial Type Discharge/Suction Pressure Gauge (0-500 PSI)
Multifunctional VAF meter
Indication lamps
Digital Ammeter (3-phase)
LP/HP control switch
Contactor (L&T MNX 25)
Replacing & fixing of following faulty items of DEA-1 or 2 (wherever required) as per the existing testing etc complete as reqd..
Stopping Solenoid 607220170003
Air filter (O) 105413100102
Air filter (I) 105413100003
Cylinder Head gasket 123408550034
Oil safety
Water safety
Gasket Set 123400190748
"O" ring set 604931300902
"O" ring set 604931301802
Wiring
Pricol controller
24 V battery charger
Radiator bottom tank
Hose Pipe Set 123400190057
DEA Servicing
Labour cost for overhauling of DEA Sets
Replacement of following faulty items i/c fixing, connections, testing complete as reqd.
28 W T-5 flouroscent rod
28 W T-5 choke
18 " Ex Fans
Indication lamps
Supplying & fixing of 2x18/36 Watts CFL/LED compound light fittings as per existing make and lumen output with suitable rating MCB & fitting cover complete as reqd.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 8-stage APFC relay in the existing MV Panel complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following rating capacitors in the capacitor panel complete with connections, testing and commissioning etc. as required.
Supplying, installing, testing and commissioning of following capacity TPN in existing MV Panel complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.
32 amps TPN
63 amps TPN
100 amps TPN
125 amps TPN
Supplying and fixing DOL starter for 5 HP pump complete with connections, testing and commissioning etc. as required.
Repairing & Servicing of monoblock pump i/c replacement of defective parts etc complete as reqd.
Supply & fixing of 3" dia GI pipe for inlet of pump complete as reqd.
Repairing & Servicing of ACB in MV panel i/c moving out the ACB from MV Panel, checking of all contacts, cleaning & greasing the contacts with replacing the minor defective parts & refixing the ACB etc complete as reqd.
Servicing of ACB in MV panel i/c moving out the ACB from MV Panel, checking of all contacts, cleaning & greasing the contacts, with replacing the minor defective parts & refixing the ACB etc complete as reqd.
Caliberation of IDMT relays of HT Panel/MV Panels complete as reqd.
Servicing of VCB in HV panel i/c moving out the VCB from HV Panel, checking of all contacts, cleaning & greasing the contacts & refixing the VCB etc complete as reqd.
Replacement, Installation, Testing and Commissioning of following zone micro processor based Fire main control panel suitable for wall/floor mounting fabricated from CRCA sheet along with sealed maintenance free battery as secondary power source, power supply & battery charger etc of capacity to take care of standby power supply inbuilt PA system. The necessary talk back facility between panels shall be incorporated in the panel itself complete with telephone hand set & necessary hardware & software etc as required.
10 Zones Main Control Panel
Replacement, Installation, Testing and Commissioning of following zone micro processor based Fire main control panel suitable for wall/floor mounting fabricated from CRCA sheet etc as required.
4 Zones Local Control Panel
Replacement of faulty sealed maintenance free battery of 7AH, 12 V for FDFA system complete as reqd.
Refilling of existing 4.5 Kg CO2 in the existing 4.5 Kg CO2 type cylinder including transportation to the filling facility and back to TE Bldg. including testing and commissioning complete etc as required.
Replacement Supplying and fixing of hose pipe & horn for existing 4.5 Kg CO2 type Fire extinguishers complete etc as required.
M/S SANJAY ELECTRICAL COMPANY
GOPAL KRISHAN CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .