Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance BAMNA HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance NAJARPUR SASNI HATHRAS UTTAR PRADESH 204101 | HATHRAS | HATHRAS | UTTAR PRADESH | 204101 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
27 Jun 2024, 5:00 pmClosed
SE EDC HATHRAS
SE EDC HATHRAS
Turnkey
2024_DVVNL_931949_1
EDCH-22/2024-25
Open Tender
Electrical Works
Item Rate
120 days
SE EDC HATHRAS
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
DVVNL
₹18,000
11 Jul 2024
22 Jun 2024
27 Jun 2024
22 Jun 2024
27 Jun 2024
22 Jun 2024
Amount
Supply of Following Matarial as per relevent ISS
ST Pole 11 Mtr. Long
Pcc Pole 8.5 Mtr. Long
Stone Pad 300x300x75 mm
11 KV Steel Cross Arm V Type 65x65x6 mm
11 KV Pin Insulator
11 KV Pin with Nut
11 KV Disc Insulator
11 kv Disc Fitting
H.T Tee Channel
ACSR weasel Conductor
Stay set Complete
G.I Wire 6 SWG
G.I Wire 8 SWG
250 KVA 11/0.4 KV T/F
LT PVC Cable 3.5x400 Sqmm
M.S Top Channel 125x65x2240 mm
Dropper Channel 100x50x2028 mm
Aluminium Tape
Clamp with Bolt & Nut
11 KV VCB Outgoing
4 Core LT MCB With Box
Barbed Wire
3x70 Sqmm 11 kv XLPE Cable
I/D & O/D Cable Jointing Kit suitable for 3x70 Sqmm 11 kv XLPE Cable
G.I Pipe 6" dia
ACSR Dog Conductor
F-Braket
Nut, Bolt & Washer
Danger Board with Clamp N&B
Guarding Angle, Nut Bolt with eye bolt Complete
Number Plate
AL LUG 240 sqmm
Copper L-Piece 50x225x10 mm(LS)
Scope of work
Safe Carriage of following material from Electricty store center Hts to Pit site of work through the Kacha and Pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-50 Kms.)
11 KV Pilfer proof metering cubicle
11 KV CT/PT Metering Pole Mounting Unit
3x70 Sqmm 11 kv XLPE Cable
Cable Jointing Kit Outdoor suitable for 3x70 Sqmm 11 kv XLPE Cable
T/F Base Angle with clamp Nut & Bolt
Errection of following Poles with grouting including Cutting of kharanja/mettalic road/concrete portion while digging pit & complete H.T./L.T. fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
ST Pole 11 Mtr. Long
Pcc Pole 8.5 Mtr. Long
Fixing/ Errection of following item, cost of labor, material and T&P which required for completion of work
Stone Pad 300x300x75 mm
11 KV Steel Cross Arm V Type 65x65x6 mm
11 KV Pin Insulator
11 KV Pin with Nut
11 KV Disc Insulator
11 kv Disc Fitting
H.T Tee Channel
Stay set Complete
M.S Top Channel 125x65x2240 mm
Dropper Channel 100x50x2028 mm
Aluminium Tape
Clamp with Bolt & Nut
11 KV VCB Outgoing
4 Core LT MCB With Box
Barbed Wire
I/D & O/D Cable Jointing Kit suitable for 3x70 Sqmm 11 kv XLPE Cable
G.I Pipe 6" dia
F-Braket
Nut, Bolt & Washer
Danger Board with Clamp N&B
Number Plate
AL LUG 240 sqmm
Copper L-Piece 50x225x10 mm(LS)
11 KV Pilfer proof metering cubicle
11 KV CT/PT Metering Pole Mounting Unit
Cable Jointing Kit Outdoor suitable for 3x70 Sqmm 11 kv XLPE Cable
T/F Base Angle with clamp Nut & Bolt
Installation of 250 KVA T/F on newly/Old constructed Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work
Errection and grouting of stays as per RESPO Norms and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Providing & Fixing of earthing rod as per RESPO Norms and as per direction of supervising engineer.
Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
ACSR weasel Conductor
LT PVC Cable 3.5x400 Sqmm
3x70 Sqmm 11 kv XLPE Cable
ACSR Dog Conductor
Construction of plinth of size 5' * 5 * 4' above ground level one ft below the ground level of 9" After Exavation of 4 "earth brick ballast shall be provided and rammering will be done properly After ballast shall be provided and rammering will be done properly After that a retaining wall 9"width by fist class brick in ratio 1:4 of cement & sand shall be made . The earth shall be filled up to one ft.below the top of the plinth After this brick ballast shall be provided upto 6"from the earth level and proper rammering shall be done one No. jall of 12 mm MS tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement sand & stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand.
Pipe earthing of 250 KVA medium Power Transformers
Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended netal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut
Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer
Re Guarding / Guarding of 11 KV line by laying, stringing, sagging and binding of 2 Nos. parallel GI wire 6 SWG after providing, fabrication and fixing of guarding angle and fabrication and fixing of X-guards (Tillis) of GI wire at distance of 3 Mtr.
Earthing of VCB With Material
Bobby Electricals
P K ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .