Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.3 LAccepted-AOC D NO 4 6 92 PERIYAR NAGAR THANGAMAPURIPATTINAM METTUR DAM 636402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | 1 | Accepted-AOC L1 | |
| 2 | 2₹8.6 L+₹3.2 L (60.9%)Rejected-AOC 36 204 N NO 52 204 V O C NAGAR THANGAMAPURIPATTINAM METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | 2 | Rejected-AOC L2 | |
| 3 | 3₹12.4 L+₹7.0 L (132.0%)Rejected-AOC C3 SIDCO INDUSTRIAL ESTATE METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | 3 | Rejected-AOC L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | KEEN ERECTORS L2 | ARR AND CO L1 | ANBU ENGINEERING INDIA PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|
| 1.00 | Labour charges for welding eroded initial welding joints in the flue gas duct above 2 Meter level including cost of consumable and T&Ps. | 500 | Mtr | 147 ₹73,500 | 84 ₹42,000 Lowest | 200 ₹1,00,000 |
| 2.00 | Charges for transporting of 6mm M.S./ Chequred plates from Central Stores/MTPS to Boiler area, cutting into required size,leading, lifting, positioning on the eroded portions of above 1.5 meter side wall portion of the duct including cost of consumable and T&Ps. | 40 | M2 | 1,571 ₹62,840 | 455 ₹18,200 Lowest | 2,100 ₹84,000 |
| 3.00 | Charges for renewal / reconditioning of 1 No. flange at bottom of hopper, man hole doors, poking hole, heating chamber,provided & removal of working platforms on hopper and related equipment. | 20 | Nos. | 19,995 ₹3,99,900 | 13,550 ₹2,71,000 Lowest | 25,000 ₹5,00,000 |
| 4.00 | Removal and refixing of same insulation and refixing skin casing (GI Sheet) inclusive neccesary scaffolding arrangements including cost of consumable and T&Ps. | 300 | M2 | 799 ₹2,39,700 | 485 ₹1,45,500 Lowest | 1,500 ₹4,50,000 |
| 5.00 | Charges for loading into tipper and disposing the waste insulation to near marked area including cost of consumable and T&Ps. | 1 | Time | 8,100 ₹8,100 | 4,810 ₹4,810 Lowest | 12,000 ₹12,000 |
| 6.00 | Cutting gas | 2.5 | Set | 2,954 ₹7,385 | 2,500 ₹6,250 Lowest | 3,500 ₹8,750 |
| 7.00 | Welding Rod | 180 | Kgs | 365 ₹65,700 | 250 ₹45,000 Lowest | 450 ₹81,000 |
Tender Value
Refer Docs
EMD Value
₹8,100
Closing Date
3 Nov 2026, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS 1 BM Unit IV AOH 2026 27 ESP AB CD Pass Hoppers strengthening of the welding joints patch welding the eroded portions and other related works etc
2026_EB_719129_1
CE / MTPS-I / SE / M-I / BM /OT. 174 / 2026-27
Open Tender
Power/Energy Projects/Products
Works
30 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹8,100
Yes
27 Nov 2026
28 Oct 2026
4 Nov 2026
28 Oct 2026
3 Nov 2026
28 Oct 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour charges for welding eroded initial welding joints in the flue gas duct above 2 Meter level including cost of consumable and T&Ps. | 500 | Mtr | - | - |
| 2 | Charges for transporting of 6mm M.S./ Chequred plates from Central Stores/MTPS to Boiler area, cutting into required size,leading, lifting, positioning on the eroded portions of above 1.5 meter side wall portion of the duct including cost of consumable and T&Ps. | 40 | M2 | - | - |
| 3 | Charges for renewal / reconditioning of 1 No. flange at bottom of hopper, man hole doors, poking hole, heating chamber,provided & removal of working platforms on hopper and related equipment. | 20 | Nos. | - | - |
| 4 | Removal and refixing of same insulation and refixing skin casing (GI Sheet) inclusive neccesary scaffolding arrangements including cost of consumable and T&Ps. | 300 | M2 | - | - |
| 5 | Charges for loading into tipper and disposing the waste insulation to near marked area including cost of consumable and T&Ps. | 1 | Time | - | - |
| 6 | Cutting gas | 2.5 | Set | - | - |
| 7 | Welding Rod | 180 | Kgs | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_863626.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .