power cable for direct burial xlpe ugac cable Power Cable For Direct Burial Xlpe Ugac Cable ( 4750 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Mode of Buying Through bidding only - Size of Cable (in Sq.mm) 400.0 400.0 Number of cores (nos) 4 4 Cable Type Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 BIS marked yes - BIS certificate number CM/L-8646391 - Armouring Galvanised round steel wire armoured Galvanised round steel wire armoured
Galvanised steel Strip armoured Armouring Type single wire or strip armouring single wire or strip armouring
Double wire or strip armouring 1/3 shape of conductor Stranded and Shaped Solid
Stranded
Stranded and Shaped CONSTRUCTIONAL Number of armouring strip/wire for each size of cable 36 - size of armouring strip/wire for each size of cable 4 mm x 0.80 mm +/-10 - Material of conductor Aluminium EC Grade - Weight of finished cable per meter 5.500 - In addition to marking requirements as per relevant specification
sequential marking for length
Size of the cable
Type of the cable and Drum Number shall be embossed on every metre of the cable yes - standard cable length on a drum 250 meter for size 240sqmm and above. - Part length which can be supplied by seller (meter) 500 - cable to be supplied on wooden drums conforming to IS: 10418/82 with latest amendments. yes - Quantity supplied shall not be more than the ordered quantity. yes - CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laoratory to prove conformity to the specification for minimum and maximum ratings. yes - Type Test Certificate No. ATCC2015041109 - Type Test Certificate date 11.04.2015 - Name of Lab Amit Test And Calibration Centre - Address of Lab 19/168
Sarai Rohilla
Old Rohtak Road
Near - 2/3 Shastri Nagar
Metro & Usha Mata Mandir
Delhi-110035. Test Report to be furnished to the buyer on demand yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mohammad Rafi 711202
OFFICE OF ASSISTANT MATERIALS MANAGER
LILUAH CONSTRUCTION DEPOT
EASTERN RAILWAY
BELUR
HOWRAH 711202 4750 30