HQ CWE AGRA
112, TAJ ROAD AGRA CANTT
REPAIR / MAINT OF 11 KV SUB STATION, HT VCB, HT CABLE END JOINTS, OH LINE DISTRIBUTION TRANSFORMER, PAINTING, CENTRIFUGING OF TRANSFORMER OIL BREATHER, EARTHING, POLE, PAINTING ETC UNDER GE (EAST) AGRA
2023_MES_611475_2
84282/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGRA
MES contractors enlisted in Class D category b(ii) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
GE EAST AGRA
₹60,000
Yes
10 Nov 2023
19 Sept 2023
17 Oct 2023
19 Sept 2023
10 Oct 2023
26 Sept 2023
19 Sept 2023 - 21 Sept 2023
Amount
Dehydration and Filtration of existing transformer oil in transformers (11 KV system step down to 11/0.433 KV) by centrifuging machine on site at different locations without disturbing the power supply system. The machine continuously run round the clock till obtaining the dielectric strength of oil 60 KV minimum 2.5 mm gap and carrying out IR test of primary and secondary of transformer including commissioning and testing of transformers after topping up with new transformer oil complete all as specified and directed. Note:- New Transformer oil for topping up shall be measured in relevant items of BOQ.
Supply and filling/Toping up new transformer oil low viscosity approved make as per IS 355 of 1992 and min di-electric strength 40 KV (RMS) at 2.5mm gap high viscosity in transformer complete all as specified and directed Make Power Oil/savita or any other approved make Note : (i) Test certificate from manufacturer of oil shall be provided by the contractor. (ii) Supply shall be given in sealed containers and empty containers shall be Govt Property.
Supply, laying & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminum conductor11 KV (E) grade, cross sectional area 120 Sqmm 3 core as per IS-7098 suitable for earth system laid in trenches including taking out unserviceable /brunt HT cable of any type /rating, complete all as specified and as direcetd.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc, complete all as specified and directed Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection cover/Bricks .
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed .
Removal of surplus excavated soils to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HVP Type 1, 300mm x 180mm x 40mm Peak, factory made, ISI marked, complete all as specified and directed .
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of upto 110mm bore HDPE pipe of any description below/under existing road surfaces/apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing strata after laying pipes complete all as specified and directed. (NOTE : (i) Pipes shall be laid minimum 60 cm below/under existing road surfaces/ apron /floors etc). (ii) Equipment, tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor withut any extra cost to the Govt.
Supply, laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) of size 110mm outer dia with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc, ISI marked. complete all as specified and directed by ..
Supplying and fixing in replacement of GI tubing, 80 mm bore, light grade as in sleeving/protection of cable etc fixed on pole / wall etc. With and including suitable size of MS clamp and nut, bolt ,washer etc complete all as specified and directed
Supply and fixing in replacement 2V, 100 AH maint free VRLA battery complete all as specified and directed.
Material and labour for testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Notes : (i) All T&P and other acceseries required for checking and finding of fault in cable shall be provided by the Contractor (ii) Charges/rent of the fault locating mobile machine, operator, engineer, electricians etc shall be deemed to included rate quoted by Contractor. (iii) Checking and finding fault upto 03 places of same route of the cable will be considered as one Job
Disconnecting and taking out old unsrviceable HT joint and fixing only, jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for straight through, cold shrinkable type complete with all jointing material and accessories suitable for 95 to 185 Sqmm 3 core XLPE armoured aluminium conductor cable of any sizes and type including excavation, returning and filling upto 10 mtrs, complete all as specified and directed. (Note : Straight through Joint 95 to 185 Sqmm issued under Sch B free for fixing)
Disconnecting and taking out old unsrviceable HT joint and fixing, jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for straight through, heat/cold shrinkable type complete with all jointing material and accessories suitable for 240 Sqmm 3 core XLPE armoured aluminium conductor cable of any sizes and type including excavation, returning and filling upto 10 mtrs, complete all as specified and directed.
Disconnecting and taking out old Unsrviceable HT joint and Supply & fixing , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for End joint (Indoor termination), heat shrinkable type complete with all jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 95 Sq mm complete all as specified and directed.
Disconnecting and taking out old Unsrviceable HT joint and Supply & fixing , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for End joint (Indoor termination), heat shrinkable type complete with all jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 120 to 185 Sq mm complete all as specified and directed.
Disconnecting and taking out old Unsrviceable HT joint and Supply & fixing , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for End joint (Outdoor termination), heat shrinkable type complete with all jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 95 Sq mm complete all as specified and directed.
Disconnecting and taking out old Unsrviceable HT joint and Supply & fixing , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for End joint (Outdoor termination), heat shrinkable type complete with all jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 120 to 185 Sq mm complete all as specified and directed.
Disconnecting and taking out old Unsrviceable HT joint and Supply & fixing , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for End joint (Outdoor termination), heat shrinkable type complete with all jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sqmm complete all as specified and directed.
Supply and fixing in replacement including commissioning & testing of single pole , horn gap, non linear meta oxide resistance surge lightening arrester having rated voltage 9 KV (RMS) as per IS-3070 ( Part I)1985 suitable for 12 KV, out door type, maximum continuos operating voltage not less than 7.65 KV (rms), nominal discharge current 10KA (peak), power frequency reference lot less than MCOV, max residual voltage for discharge current of 10 KA and 8/20 micro sec-current wave- 40 KVp, long duration discharge class-II( as per IEC), pressure relief class/current-A/40KA,28/75 KV insulation level, 29.9 KV switching residual discharge loltage, 100 KA(peak) and 25mm/KV minimum creaping distance of highest system voltage with all fittings, complete all as specified and directed.
Dismantling and taking out transformer of any capacity from its position from any location ie. two pole/four pole structure/plinths for repair / rewinding of distribution transformer 11/0.433 KV disconnecting / opening HV, LV electrical connections, earthing connections along with following other works for transformer:- (a) Transporation of transformer to workshop including loading and unloading and back to site by making necessary arrangement of T&P (Hydra/ vehicle/ tripoid to be arranged by contractor). (b) Opening of transformer top cover by extraction, removing of serviceable - unserviceable nuts bolts and washers etc in presence of JE/Engr-In-Charge (c) Draining out of transformer oil in dry and clean container and keeping in safe custody for reuse. (d) Lifting primary coil (HT) and secondary coil (LT), dismantling of transformer complete part by part carefully, and display all the parts without damaging any portion (e) Reassembeling the transformer complete with all existing serviceable parts and new parts as ordered. (g) Reinstall the transformer at site in position as directed after repair connecting HV, LV electrical connections, earthing connections and testing to entire satisfaction on load. Notes :-(a) Payment for repair work ie winding of coil, dehyderation, transformer oil topup to be measured and paid seprately in appropriate item of BOQ (b) Supply of new nut, bolts & washers of transformer top cover shall deemed to be included in UNIT RATE QUOTED.
M& L for rewinding of HV leg coil of copper conductor for transformer of any capacity complete with insulation, varnishing by vaccum impregnation and baking of coil assembly to match with the existing original winding coils, etc complete all as specified and directed.
M& L for rewinding of LV leg coil of copper conductor for transformer of any capacity complete with insulation, varnishing by vaccum impregnation and baking of coil assembly to match with the existing original winding coils, etc complete all as specified and directed.
M & L for replacement of old silica Gel for dehydrating Breather of T/F cleaning the breather internally and externally and filling new silica gel blue colour in dehydrating breather.
Supply and fixing in replacement of brass male contact suitable for Gang Operated Devices, 11000 volts grade complete all as specified and directed.
Supply and fixing in replacement of brass female contact suitable for Gang Operated Devices, 11000 volts grade complete all as specified and directed.
S&F in replacement for non-metal part (Porcelain) HV bushing complete with packing for outdoor/indoor/ canopy type distribution transformer of any capacity complete all as specified and directed.
S&F in replacement for non-metal part (Porcelain) LV bushing with packing for outdoor/indoor/canopy type distribution transformer or servo stablizer of any capacity, complete all as specified and directed.
S&F in replacement HV bushing (Brass) terminal rod of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of any capacity, with washer of brass of suitable dia & length for transformer terminal with BRASS nut and bolts and washers 8 nos complete with oil seal, gaskets, ring washer etc complete all as specified and directed.
S&F in replacement LV bushing (Brass) studs rod of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of any capacity, with washer of brass of suitable dia & length for transformer terminal with BRASS nut and bolts and washers complete with oil seal, gaskets, ring washer etc complete all as specified and directed.
Supply and replacement of Packing gasket for top cover and terminal box for HT and LT side as per existing sample for out door/indoor type transformer including nuts, bolts and washer etc for upto 630 KVA transformer (after draining out transformer oil and refilling to the same transformer oil) complete all as specified and directed. Note :- Cost of minor spares i.e nut bolt and washer if required to complete the job is deemed to be included in quoted rates.
Supply and replacement of air breather assembly as per existing size, shape and specification with and including filled silica gel upto 2 kg as per sample complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat primer , one under coat and one finishing coat of alumn paint complete all as specified and directed.
Fixing only 11KV air break gang operated switches vertical/horizontal mounted includin insulators and operating mechanism including dismantling old unsv air break gang operated switches , complete all as specified and directed. (Note : GOD to be issued under Sch B free for fixing, old unsv GOD to be deposited to MES store)
Supply ,installation, testing and commissioning in replacement of canopy headed HT 11K volt grade, 3 phase , AC, 50 cycle, feeder pillar box, factory made outdoor pedestal type double door, IP 65 protection with incoming and outgoing cable alloyfabricated out of 3.15 mm thick CRCA sheet with powder coated painting in side and outside of approved shade ,locking arrangement with 02 Nos 19mm dia lock of make Godrej with keys, two earthy terminal suitable cable gland for all incoming and outgoing cable grouting of feeder pillar box 30 cm above ground level by providing 90 cm long angle iron of size 50x50x6 mm welded on all the four comers embedded in PCC (1:2:4) using 20 mm graded stone agg upto 30 CM deep and 45 CM above from normal ground level complete all as specified and directed incl the following components:- (a) The panel will be having aluminium bus bar of size 50x10mm duly insulated with heat shrinkable sleeves with porcelain HT long post insulator 11 KV, Complete all as specified and directed.
Periodical maint of 11 KV yard equipment such as cleaning of insulators, greasing of isolator links, cleaning of capacitor bank bus bar and yard etc complete all as specified and directed.
M&L and T&P for disconnecting HT/LT connection, shifting, installing, testing and commissioning of step down Outdoor type copper wound transformer of any capacity from one location to other location within the defence land complete all as specified and directed Note: Cost of materials required for connecting, commissioning and testing of transformer shall be deemed to be included in quoted rate.
M& L for maintenance and overhauling of 11 KV VCB including opening, checking, cleaning with CTC, cleaning wiping of insulating components, primary & secondary circuit, spouts, bus bars, supports, CT,PT, check oil for leakage, cleaning contact tips, cover the exposed portion of bus bar with HT tape & heat shrinkable sleeves, cleaning of bushes, spout insulators for visible crack, tightness old fasteners holding moving contacts, check & correct the buffer gap adjustment & mechanism settings, testing , cleaning & overhauling of complete operating mechanism for smooth functioning, checking of control panel wiring for operation & protection for tripping & closing & rectifying the defects including Deoxidizing of all electrical contacts replacement unserviceable wiring with ferrule & lugs, reassembling & testing of complete VCB all as directed. Note:-(i) Required part for replacement will be measured and paid under relevant items as supply only. (ii) Cost of labour & cleaning material like Urethane, Gasket remover, lubricant etc for replacement is deemed to be included in quoted rate. (iii) Repair of VCB carried out by OEM trained Engineer and test report should be submitted to the Engr-In-Charge. Make for Ser No 39.01 to 39.15 : CG/ Siemens /ABB/ AREVA/ MEGAWIN/ L&T/ Schneider
Supply only vacuum interrupter 400/630/800 Amps suitable for 11KV VCBs rating, complete all as specified and directed.
Supply only breaker control switch (Trip-Neutral-Close) 4 pole/4 Terminal 660 V AC / DC pistol grip type suitable for 11 KV VCB
Supply only bus bar spout Spout suitable for 11KV VCB, Rating 630/800 Amps, made of fiber reinforced material for R,Y,B phases
Supply only bus bar Insulator suitable for 11 KV VCB, Rating 630/800 Amps,
S & F space heater assembly suitable for moisture control in 11 KV VCBs as per sample
Supply only digital IDMT relay for over current/earth fault protection control relay suitable to work on 24V/12V DC supply as per sample of HT panel of 800/630 Amp, 11 KV rating VCB of make ABB/CG/Siemens. Make of relay Ashida ADR 241 A/Micom 642/ Crompton Aegis FG 111X1/Siemens 7SR2102/L&T MC61
M & L Flag coil/master trip relay for RASVP relay type ICM21P A : 0.5-2.0 at 220V DC supply suitable for 11 KV VCB
Supply only Spring charging motor for ABB/CG/Siemens make 11 KV VCB
Supply only shunt trip/Closing coil 220/110 volts DC suitable for 11 KV VCB
Supply only rectifier monoblock assembly 600m suitable for ABB/CG/Siemens make 11KV VCBs
Supply only under voltage / over voltage / earth fault relay for ABB/CG/Siemens make VCBs
Supply only Male/ Female Moving Contact , made of copper complete suitable for 11 KV VCB
Supply only PVC insulated, unsheathed Multistranded Flexible Copper Conductor armoured Cable of size 1.5 Sq.mm, 4 core, FRLS, ISI marked, 1100 Volt Grade.
Supply only PVC insulated, unsheathed Multistranded Flexible Copper Conductor armoured Cable of size 2.5 Sq.mm, 12 core, FRLS, ISI marked, 1100 Volt Grade.
Supply only Multi Function Meter, Digital Type [Displaying A, V, PF, Hz, KVA, KW, KVAR, KWH, KVARH etc. Class 1.0 / 0.5] with RS485 Port for Communication in Modbus Protocol.
Supply only Tinned copper fuse wire 10 Amps
Supply only Tinned copper fuse wire 16 Amps
Supply only Tinned copper fuse wire 25 Amps
M & L in replacement of HRC fuse 4 A to 32 A suitable for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge
M & L in replacement of HRC fuse 40 A to 63A suitable for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge
Supplying & fixing danger notice board of 1.6 mm thick mild steel sheet , viterous enamelled white , with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps , bolts for HT 25X20 cm size complete all as specified and directed.
M & L for including removing of old words on existing VCB panel paste fidder wise CTs ratio & fidder name sticker by using radium letter / No the height of the worked minimum 5 CMs & maximum 30 letters complete all as specified
Checking tripping of circuit breaker through IDMT over current and earth fault relays at plug setting intended in service by primary current injection in CT to ensure proper function of relays trip coil control circuit etc during fault condition to match with existing including testing of over current and eath fault IDMT relays as per time characteristics by secondary injection test O/C 50% , 75%, 200% & E/F 20-80% plug setting and operating time twice the set value and TMS 1 including well cleaning and de-carbonizing of relay contacts complete all as specified and directed. Note : Caliberation of VCBs/RMUs should be carried out by VCB/RMU manufacturer and test report should be submitted to the Engr-In-Charge.
M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of transformer (11/0.433KV) complete with all connected fittings & fixtures i.e. buchholz relay, conservator tank, cooling fins and other standard fittings & attachments as per existing colour scheme and pattern with atleast two coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction including writing of SM No complete all as specified and directed. Note:- Contractor will apply one layer of greese over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates.
M&L for cleaning and removal of disintegrated & deteriorated paint by hand scrapping and preparation of of old painted exposed surfaces of Chain link fencing of 11 KV yard incl gate etc and applying two coat of aluminium / Synthetic enamel paint over a coat of a red oxide all around the exposed chain link fencing, compete all as specified and directed.
Cutting, trimming of hanging/ extended braches of trees upto a distance 3 meter from the overhead HT/LT line and making the line clear upto the entire length of the feeder including removal and disposal of the cut tree branches 50 meters away from the site complete all as specified and directed. Note : The Rates shall inclusive of T&P, hydraulic ladder, equipment such as motorised diesel operated hacksaw etc complete all as specified and as directed. Note : 1. Only branch area to be measured not one span. 2. Necessary prior permission shall be obtained from concerned Engineer-in-charge before carrying out the work. 3. All safety measures & insurance to the staff undertaking the Job shall be the Contractor's responsibility.
M&L for earthing complete with copper earth plate electrode 600 x 600 x3.15mm thick burried directly in ground vertically to a depth not less than 4.00 M below normal ground level ) with top edge of the plate not less than 3.00 M below normal ground level , connected to and including copper strip 32x6 mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 32 mm GI pipe medium grade for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 40mm bore GI pipe medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 4.00 M below normal ground level ) with top edge of the plate not less than 3.00 M below normal ground level , connected to and including galvanised iron strip 32x6mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 32mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm GI strip complete all as specified and directed.
M&L in replacement Copper strip 32 x 6mm for connection of cable to the studs of transformer HV/LV, complete all as specified and directed
M&L for cleaning and preparation of of old painted exposed surfaces all existing steel tubular poles 11 mtr long upto finial taper plug including cross arm, clamp, bracket etc and applying one coat of aluminium paint all around the exposed steel surface with and including one coats of paint in 30 cm wide bands/ strips around the poles alternatively with black & white synthetic enamel paint up to height of 1.5 m from top of PCC coping of the pole and including writing pole No. in 8 cm height letter with black enameled paint in a circle of 20 cm dia with base of synthetic enamelled paint (colour approved by GE) on pole at above top most band compete all as specified and directed.
Material and labour Cable Route indicator showing "MES HT/LT U/G 11/1.1KV" size 60cm height X 30cm wide X 50mm thick tapered on top) and route of cable with arrow (Embossed or engraved) made of RCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) 50 mm thick reinforced with 8 mm dia TMT bar at the rate of 100 mm centre to centre in suitable shape and size 60 cm x 30 cm x 50 mm thick fixed in PCC block 1:2:4 type B-2 (using 40mm graded aggregate)(size of block 30cmx 30x15cm) of 30 cm below ground level and 30cm above ground to show clear indication of cable including painting the complete slab with red paint and marking the engraved/embosed letters/arrow with white paint complete all as directed. Note :- Quoted rate shall be deemed to included the cost of excavation, returning, filling and removal of excavated earth upto a distance of not exceeding 30 mtr complete.
Supply and fix Cable Terminal Boot for Transformer comprising of Basic Impulse Level – 95kV, Bushing Diameter – 30 – 45mm, Voltage Um – 17.5kV max, Description – Flexible Bushing Boots, Diameter D Over Termination – 35mm-400mm, suitable for HT/LT XLPE UG Cable Sizes – 95 – 240 sqmm, Complete all as specified and directed
Aaradhya Ables Group
M/S VIDIT ENTERPRISES
M/s SCHOLASTIC ENTERPRISES
virendera singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .