Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹37.2 L+₹3.3 L (9.62%)Rejected-AOC | L2 | Rejected-AOC Other than L1 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
13 Mar 2024, 6:00 pmClosed
Garrison Engineer(North) Akhnoor
Garrison Engineer(North) Akhnoor PIN 181201 CO 56 APO
SPECIAL REPAIR TO BLDG No P-71, T-16 AND T-21 UNDER AOR OF SUNDERBANI OF GE (N) AKHNOOR
2024_MES_639949_2
CANO- GE(N)/AKH-61/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Sunderbani
Class D Cat a i
9 documents required · 9 mandatory
₹500
GE (North) Akhnoor
₹97,000
Yes
18 Jun 2024
16 Feb 2024
16 Mar 2024
16 Feb 2024
13 Mar 2024
23 Feb 2024
Amount
Taking down cement plaster from brick or stone walls incl racking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed.
15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces including mixing of WPC as per manufacturer's instruction & finishing the surface even and smooth without using extra cement, complete all as specified and as directed. Note :- WPC Shall be measured and paid separately.
Rendering 10 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or stone masonry surfaces including finishing the surface even and smooth without using extra cement complete all as specified and as directed.
Supply only Integral waterproofing compound.
Preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper on walls including one coat of approved primer complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of approved primer complete all as specified and as directed.
Complete removal of existing treatment incl washing, rubbing down and stopping of old painted surfaces and applying two coats of oil bound distemper to walls complete all as specified and as directed.
Complete removal of existing treatment incl washing, rubbing down and stopping of old painted surfaces and applying two coats of cement base paint to walls complete all as specified and as directed.
50mm thick PCC (1:3:6) type C-1(using 20mm graded crushed stone aggregate) as in plinth protection laid in bays n.exc 2.00 Sqm complete including finishing the surface of concrete topping even & fair with & including filling of joints with mastic filling, complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed.
Dismantling wall and ceiling boards, fibre pulp insulation etc or insulation boards/ slabs / blankets, any thickness, including cover fillets, frame work of any description etc, complete all as specified and as directed.
GI frame work 605 x 605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre intermediate channel 0.9mm thick having two equal flanges of 15mm each web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and including celing section (n.exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 centre to centre with support of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long with and including 4mm thick Non absetos fibre cement designer building board fixed or laid/inserted to GI framework with screws complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any guage, thickness as in roof covering etc complete all as specified and as directed.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter, ridge & similar works fixed with self tapping screws complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Rolled mild steel section as in main and cross beams, hip and jack,rafters, purlins, where connected to common, rafters and running rails and guiders for sliding doors: fixed with angle cleats or other connecting plates conforming to grade Fe 410-W (Gde E-250) quality 'A', complete all as specified and as directed.
Mild steel work as in wind ties for roof including securing bolts including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-250 Gde E-165 complete all as specified and as directed.
Rolled mild steel gusset plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk foring holes, without any attachement conforming to grade Fe 410-W (Gde E-250) quality 'A', complete all as specified and as directed.
Rolled mild steel Joist,channel angle or tee sections fixed independently without connecting plates etc (cut to ordinary lengths i.e with in 20mm of the length indicated) conforming to grade Fe 410-W (Gde E-250) quality 'A', complete all as specified and as directed.
Mild Steel screw bolts (machine made ) with hexagonal or square head at one end and other screwed the other , each screwed end to be fitted with washers and nut,n. exc 5cm long & dia 5 to 10mm, complete all as speciified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed.
Walling of random rubble uncoursed, well bonded, bedded and solidly hearted built in CM 1:4 complete all as specified and as directed.
Description all as per item No.25 above, but except stone, complete all as specified and directed
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed.
Brushing cleaned concrete surface with neat cement slurry with 3.0 Kg of cement per sqm complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store andd rubbish off the premises, complete all as specified and as directed.
25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub floor under tiles, complete all as specified and as directed.
Glazed ceramic tile 600x300mm/450x300mm x 7 to 8mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick bedding layer in cement and sand mortar 1:4 complete all as specified and as directed.
Non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) in floors etc area of each tiles exceeding 0.11Sqm but not exc 0.18Sqm. Set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and as directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles laid over & including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and directed.
Description all as per item No.33 above, but in vertical surfaces such as skirting/dado fixed over & including 10 mm thick rendering in cement and sand mortar 1:4, complete all as specified and directed.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each, complete all as specified and directed.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) n.exc 1.50 sqm complete all as specified and directed.
Pressed steel frames for doors with one or more rebates of size 125x60mm including necessary fixing lugs, hinges, lock strike plates complete, providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed.
Pressed steel frames for doors with one or more rebates of size 105x60mm including necessary fixing lugs, hinges, lock strike plates complete including providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed.
35mm thick, 2nd class hard wood plain, framed, panelled factory made shutters (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
30mm thick 2nd class hard wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
Vitreous china wash basin, white, oval shape, including waste fitting chromium plated brass, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets, waste pipe etc., fixed in repairs complete all as specified and as directed. Cat Part No-10017 (OVAL) of Hindware for Wash basin or its equivalent cat part of make specified in list make as approved by GE.
Vitreous china wash down water closet pan pedestal pattern in white colour excluding seat cover, flushing cistern and flush pipe fixed in repairs complete all as specified and directed. Cat Part No-20011 (SLICK) of Hindware or equivalent cat part of make specified in list make as approved by GE.
Steel windows/ventilator (Box type) factory made with double shutter with or without devetailed bar ( gauzed & glazed shutter) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3 . Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid seperately under respective item
Description all as per Item No.43 above, but only fixed glass pane shutter without glazing bars.
Mild steel framed work as in grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed.
3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
3mm thick figured glass, pin head type and glazing with oil putty in squares in exc 0.5 sq.m in each pane, complete all as specified and directed.
Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed.
All as per above item No 48, but fixed in repairs.
Hacking out old broken galss (any thickness, size, quality or description) for metal frames including punching or drilling out old galzin pins/spring clips complete all as specified and directed.
Preparation of new steel and iron surfaces of any description over 10cm in width or girth not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Preparation of old steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Steel ventilator with top hung shutter (Box type) factory made with single shutter with or without devetailed bar ( gauzed / glazed shutter) of size 60mmx60mm,16 gauge rectangular tubular frame including hinges, steel peg stay complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3
Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site, complete all as specified and directed.
Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing, complete all as specified and directed.
Aluminium handles cast type anodised of size 100mm long ISI marked complete all as specified and as directed.
150mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and directed.
Aluminium anodised barrel tower bolt 100 mm, extruded section ISI marked complete all as specified and directed.
Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed.
Curtain rod 20 mm dia Stainless steel chromium plated fixed with CP bracket & end cap, including taking down of old curtain rods, complete all as specified and as directed.
GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste in repairs in patches n exc 5 sq. m each, including taking down old and jointing new to old as required complete all as specified and as directed.
15 mm thick cement plaster rendering in CM 1:4 on roof surface with mixing of water proofing compound & finishing the surface even and fair, complete all as specified.
Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints. (c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6). Note : (i) Rates quoted shall be included the necessary taking down of the old unsv roof treatment of any description & nothing extra shall be admissible on this account.
(ii) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only.
Sunken Floor treatment :- Providing and laying of water proofing treatment to sunken portion including vertical portion by applying cement slurry mixed with acrylic based polymer modified cementitious composite compound of make as specified and approved including demolition and filling of sunken floor with & including PCC 1:5:10 type E-2 (using 40mm brick aggregate). (a) First layer of slurry of cement @0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours. (b) Second layer of slurry of cement @0.242 kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/Sqm. This layer allowed to air cure for 4 Hours. (c) 15mm thick plaster in CM 1:3 mixed with WP compound to be provided while concrete is still green. (d) Joint of/Trap/WC/Soil pipes shall be properly sealed with sealing compound. Note:(a) Concrete for sunken slabs shall be mixed with WP compounds as per manufacturer's instructions. Before carrying out water proofing treatment the sunken slab shall be tested with water for 48 hours for any leakage /dampness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested before passing for next stage. (The rate quoted includes water proofing compound as per manufacturers instructions). (b) Please note that only floor area shall be measured for payment purpose.
PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in filling of sunken slab or mass concrete, complete all as specified and as directed
50mm galvanised steel tubes medium grade with all fittings laid in spout pipe, complete all as specified and as directed.
Preparation of old decorated surface including washing,scrubbing down and stopping of painted surfaces and apply two coats of white wash on ceiling, complete all as specified and as directed.
Preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
Rendering 5mm thick cement plaster mortar 1:3 on concrete surface as in ceiling finished even and smooth without using extra cement complete all as specified and as directed.
Repair to balcony/Facia and soffit of chajjas etc by taking down old rendering and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqm in width or girth & providiong 15 to 20mm thick dubbing coat where required to match with the existing thickness in CM 1:3 including formwork/scaffolding work upto height 7.0mtr above ground level of bldg complete all as specified and as directed.
Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) 3 layered hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified.
Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed.
Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed.
Mild steel galvanized steel tubing 20 mm bore medium grade with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
Mild steel galvanized steel tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
20 mm dia bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairs complete all as specified and directed.
15 mm dia bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairs complete all as specified and directed.
Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) complete all as specified and directed.
PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs complete all as specified and as directed.
Vitreous china squatting pan "Orissa Pattern" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'S' trap fixed in repairs complete all as specified and directed. Cat Part No-20042 (ORISSA PAN (ECO)) of Hindware or equivalent cat part of make NEYCER, CERA, PARRYWARE as approved by GE.
PVC connection 15mm size with PTMT nuts on both ends of length 450mm fixed, complete all as specified.
Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern), includding all fittings, heads , shoes bends , swan-necks etc . complete all as specified.
110mm bore PVC SWR Type-B pipes (pressure not less than 6 kg /cm2) single socket in any length with rubber joints laid in floors/trenches etc all as specified and directed.
PVC SWR bends any radius 110 mm bore, complete all as specified.
110mm bore PVC SWR Type-B pipes ( pressure not less than 6 kg /cm2) single socket in any length with rubber joints fixed to walls with PVC//MS holder clamps and conforming to IS-1729 complete all as specified and directed.
Description all as per srl item No 85 above but 75mm bore.
PVC (SWR) Bends (any radius) with access door of 110 mm bore, complete all as specified and directed.
PVC (SWR) branch piece, single (single Y) equal or unequal ordinary or inverted of 110 mm bore pipe complete all as specified and directed.
PVC (SWR) branch piece, double (double Y) equal or unequal ordinary or inverted of 110 mm bore pipe complete all as specified and directed.
PVC (SWR) junction single, (Single T) equal or unequal of 75mm bore provided with access door, complete all as specified and directed.
PVC (SWR) bend 75mm provided with vent horn & access door, complete all as specified and directed.
PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement, fixed in repairs,complete all as specified and directed.
110mm bore PVC SWR Type A pipes ( pressure not less than 4 kg /cm2) single socket in vertcal length for rain water with rubber joints fixed to walls with PVC//MS holder clamps complete all as specified and directed.
PVC (SWR) branch piece, single (single Y) equal or unequal ordinary or inverted of 75 mm bore pipe provided with oval access door, complete all as specified and directed.
PVC (SWR) branch piece, single (single Y) equal or unequal ordinary or inverted of 110 mm bore pipe provided with oval access door, complete all as specified and directed.
Bib tap 15 mm bore with flange, Brass CP, fancy type. with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed in repairs, complete, all as specified & directed. CAT PART NO-CON-107KN of Jaquar or equivalent cat part of make as specified in list of make approved by GE.
15mm bore pillar tap cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule complete, all as specified & directed. CAT PART NO-CON-021KN of Jaquar or equivalent cat part of make as specified in list of make approved by GE.
20mm bore Stop valve cast copper alloy screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete, all as specified & directed.
15mm bore Stop valve cast copper alloy screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete, all as specified & directed.
Stop valves/angle valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 15mm fixed in repairs, complete, all as specified & directed. CAT PART NO-CON-053KN of Jaquar or equivalent cat part of make as specified in list of make approved by GE
15mm bore Stop valve cast copper alloy chromium plated fancy type with long shank and cup (concealed type) screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete, all as specified & directed. CAT PART NO-CON-083FTK of Jaquar or equivalent cat part of make as specified in list of make approved by GE
Brass chromium plated shower rose 125mm size with or without swivel joints, with arm any size, including fixing to steel pipe or union complete all as specified and directed
Towel rail 600mm long of CP fixed with and including chromium plated brass screws and wooden/plastic cleats, complete, all as specified & directed. CAT PART NO-ACN-1111SM of Jaquar or equivalent cat part of make as specified in list of make approved by GE
Corner Glass Shelf (with Bracket), complete all as specified and directed CAT PART NO -1173 of Jaquar or equivalent cat part of make as specified in list of make approved by GE
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Reinforced cement concrete (Nominal mix), type B1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns complete all as specified and as directed.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and as directed.
TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified and as directed..
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, fair finished surface of concrete, complete all as specified .
Pre cast reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregates) as in manhole cover slabs including use and waste of necessary formwork complete all as specified and directed.
PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in any type of soil, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 150 mm diameter incl fittings, complete all as specified and directed.
RCC class NP3 150mm dia drain pipes laid in trenches and jointed with & including coller complete all as specified and directed.
Concrete bed to drain pipes 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in stone concrete block or slab walls,complete all as specified and directed.
100mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floor/hardstanding etc, finishing surface even and fair, complete all as specified and directed.
Screed bed or bedding layer of cement mortar 20 mm ,1:4 thick for laying floor finishes complete all as specified.
Chequered cement concrete tiles 300x300x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment laid over screed bed or bedding layer complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Form work to faces of walls, retaining walls, abutments, parapits and staircase railings and similar work including attached pillasters,buttresses etc vertical or to better with fair finished surface of concrete complete all as specified & directed
Reinforced Cement concrete (Design mix) M-25 (using 20 mm graded crushed stone aggregate) as in walls, retaining walls, basement walls and the like any thickness above top of footings including attached pilasters and buttresses complete all as specified and as directed.
Reinforced Cement concrete (Design mix) M-25 (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under reamed piles and mass concrete complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mi-tred/stopped ends etc. complete all as specified and as directed.
Raised pointing to random rubble, uncoursed or brought upto course masonry in CM 1:4 complete all as specified and as directed.
Precast cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) as in bonders for stone walling set in cement mortar 1:6 including use and waste of necessary formwork, complete all as specified and directed.
Extra over stone walling of random rubble walling, uncoursed or brought for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face stones (lime and sand stone) and dressing of face beds and joints,complete all as specified and as directed.
75mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber ring joints laid in stone walling for weep holes, complete all as specified and directed.
Brass chromium plated health faucet with one metre long flexible tube and wall hook fixed to iron pipe fixed in repairs complete all as specified and directed.
Plastic water closet seat cover white closed pattern with flat bottom and cover including chromium plated hinges device fixed in repairs, complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top, bottom, side/ back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers etc. are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
All as per srl item No 135 above, but One light point/fan /bell point controlled by one switch.
All as per srl item No 135 above, but One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board .
All as per srl item No 135 above, but One 3 pin 5 amps socket point controlled by one 6 amps switch on same board .
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Make of Cables Havells, KEI,Grandlay (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers etc. are to be used of same make/brand only and shall be deemed in to included in quoted rate only.) for One 15 amps power socket outlet point controlled by one 16 amps switch on independent board.
Modular type switch 6 Amps, single pole,1 way, 1 module,240V with cover plate, ISI Marked Complete all as specified and directed. “Cat part No ACVSXXWO61 of Crabtree (Havells) or ts equivalent cat part of make Anchor, Legrand, Seimens as approved by GE”.
Modular type switch 16 Amps, single pole, 1 way, 1 module,240V with cover plate, ISI Marked Complete all as specified and directed. “Cat part No ACVSXXW161of Crabtree (Havells) or ts equivalent cat part of make Anchor, Legrand, Seimens as approved by GE”.
Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked with cover plate Complete all as specified and directed. “Cat part No ACVKCWW163 of Crabtree (Havells) or ts equivalent cat part of make Anchor, Legrand, Seimens as approved by GE”.
Modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC with cover plate ISI Marked Complete all as specified and directed . “Cat part No ACVKSWW063 of Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Seimens as approved by GE”.
Fan regulator modular stepped type 100 Watts, 2 module 240Volts, AC ISI marked complete all as specified and directed. “Cat part No ACVRFHW008 of Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Seimens as approved by GE”.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Energy saving LED lamps 7 watt, 230 volts, 50 HZ , 0.95 PF. complete all as specified and as directed. Make- Havell Cat part No LHLDERHEMD8X007 or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved.
LED light fitting 1x10W bulk head luminaries IP 65 complete with all accessories including LED lamp 10 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz, complete all as specified and as directed. Make- Havell Cat part No-RUGBYGENXFTS10WLED865SSYMBOPC or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved.
Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
LED light luminaire 600mm x 600mm 35/36 watt, 220 AV recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, Holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make- Havell Cat part No-PLUTONEO2X2PLR28WLED840S or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete incl testing after fixing all as specified and directed. Make- Havell Cat part No-LUMILINEPLUSBS10WLED830SPCSSIND or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved.
LED light fitting 1x20W, 220V, AC decorative box type with driver, Holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make- Havell Cat part No-LUMILINEPLUSNEOBS20WLED830SPCSSIND or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved.
Ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) incl taking down existing and deposit with MES all as specified and directed. “Cat Part No Zinger Make Havells or its Equivalent cat part of make as specified in list of make here- in after.
Taking down old unserviceable Exhaust fan of any type/size from existing location and deposit in MES store yard and Supply and fix exhaust fan single phase metal body, AC 230 Volt, 50 Hz of size 300mm sweep with louvers shouter complete with all accessories including connecting up from ceiling rose to motor all as specified and directed. "Cat part No refresh air SPS of Havells standard or its equivalent, Bajaj, Orient".
Supply and fixing in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed. Make Havells(Monza EC),or equivalent cat part of make as specified in list of make here-in-after. Note:- Old Unserviceable geysers shall be deposited to MES store yard.
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 16 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified and as directed. Make:- Havells cat part No-DHDPSHODPW16 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 12 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified and as directed. Make:- Havells cat part No-DHDPSHODPW12 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
Sheet metal enclosure double door type for DBs single pole and neutral 8 way 240 V with 200 Amp rated bus bar including blanking plates where required complete all as specified and as directed. Make:- Havells cat part No-DHDPSHODPW08 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
MCCB 04 pole 415 volts 16 KA, 63 Amp adjustable thermal & fixed magnetic setting type suitable for TPN vertical loadline DB fixed in replacement, complete all as specified and as directed. Make : Havells Cat part No IHDA3BBF0063 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE..
VTPN verticle loadline double door distribution box (DB) fitted with Bus bar neutral link, blanking plates of 4 way with suitable for incomming MCCB 'I/C' frame,having isolated neutral bar, mechanical impact strength IK09,door earthing suitable for MCCB upto 125 Amp including MCCB complete all as specified and as directed. “Cat part NoDHDPTVODRW04 of Havells, or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
Sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
MCB single pole and neutral 50 to 63 amps 240 volts 10 KA 'C' series, complete all as specified and as directed. Make:- Make:-Havells cat part No-DHMGCSNF050 to 063 or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE
MCB single pole & neutral 6 to 32 amps 240 volts 10 KA 'C' series fixed in repair, complete all as specified and as directed. Make:-Havells cat part No-DHMGCSNF006-032 or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 35 Sqmm nominal cross section x 4 core, complete all as specified and as directed.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 2 core, complete all as specified and as directed.
Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- (i).Dry fine sand of best available quality shall be used. (ii).Punned thickness shall be made and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45cm x 45cm x 45 cm,RCC cover 1:2:4 type B1 of size 45x45x6 cm, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.Note:- The required resistance of Earthing shall be less than 3 ohm, If not found to the required resisstance, the contractor has to re earthing for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.
M/s Sekinder Paul Sharma
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .