Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.2 L+₹2.3 L (6.35%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹39.1 L+₹3.2 L (8.98%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹41.3 L+₹5.4 L (15.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹41.4 L+₹5.5 L (15.4%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
29 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2023_MES_626080_1
GE/NRC/8610/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹96,000
Yes
11 Jan 2024
1 Nov 2023
1 Dec 2023
1 Nov 2023
29 Nov 2023
15 Nov 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
All as per item No. 01.00 above but more than 1.5 Mtr and upto 2 mtr.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
Supply and fixing in replacement of metal box MS enclosure made out of CRCA sheet 3.00mm thick of size 450mm x 450mm x 250mm depth complete with three phase and neutral aluminium bus bar of capacity 200 Amps and fixing of 3P, 100A MCCB mounted on epoxy insulators, fixing arrangement with suitable MS Clamps of size 32 x 6 mm thick all as specified and directed. Note : Rate for MCCB 100 Amp, Aluminium Busbar 3 pole and 1 neutral of 200 Amp, epoxy insulators and MS clamps of size 32 x 6mm included in this item rate.
Supply and joint cable jointing kit straight through joint epoxy type of size 70/95 sqmm 3.5 all as specified and directed. Make : Denson, Raycom
Disconnecting & taking out cable LT 1100V grade any size complete all as specified.
Supply, fixing and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 2 core 6 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed.
All as per Ser item No. 8.00 here in before but 2 Core 10 Sqmm
All as per Ser item No. 8.00 here in before but 2 Core 16 Sqmm
All as per Ser item No. 8.00 here in before but 4 Core 16 Sqmm
All as per Ser item No. 8.00 here in before but 4 Core 25 Sqmm
All as per Ser item No. 8.00 here in before but 3.5 Core 35 Sqmm
All as per Ser item No. 8.00 here in before but 3.5 Core 50 Sqmm
All as per Ser item No. 8.00 here in before but 3.5 Core 70 Sqmm
All as per Ser item No. 8.00 here in before but 3.5 Core 95 Sqmm
All as per Ser item No. 8.00 here in before but 3.5 Core 120 Sqmm
All as per Ser item No. 8.00 here in before but 3.5 Core 150 Sqmm
Supply and fixing in replacement of LED flood light fittings 200 watts for high mast light complete with environmetly friendly, long life, die cast aluminium flood light with highly efficient LED as light source, suitable for high mast light pole of any height, complete all as specified and directed by Engr-in-Charge.
M&L for servicing of motor and SWR wire rope of high mast light pole any height complete including greasing, winding, required spares included in this items rate, all as specified and directed by Engr-in -Charge.
Supply, fixing and install in replacement of 7 mtr height octagonal pole top 70 mm, bottom 130 mm, 3 mm thikness with base plate 200x200x12 mm and GI 64 micron, M19x600 EN 8 grade foundaction bolt and 1 mtr arm for light fittings complete including foundation drawing provided by OEM for foundation of pole. Note : Rate for RCC foundation as per drawing, Excavation, returning filling, 7mtr pole, foundation bolts and nuts included in this item rate.
M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and innter dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50 mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50 sqmm cable complete all as specified and directed.
M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 90mm and innter dia 75mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90 mm suitable for cable protection of size 70 sqmm to 95 sqmm cable complete all as specified and directed.
Dismantling of old steel pole / struts any type and size including demolition of concrete, foundation, necessary excavation and earth work and transportation etc.
Supply and errect in true vertical in replacement of steel tubular swaged pole complete with MS Box plate 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolt, nuts washers & screws as specified type 410-SP-31 (9 mtr long) Made out of ERW MS tubing confirming to IS-2713 Part II including drilling holes of required size for fixing cross arms etc painting with two coat of aluminium paint over a coat of red oxide primer.
Supply, install erect in trench vertical position in replacement of steel tublar seweaged welded poles complete with MS base plate of 6mm thick of size 300mm x 300mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 8.5 mtr long 410 SP-22 swan neck type including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, with inbuilt junction box for 3 phase 4 wire AC supply and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge.
Demolition of PCC of any description above/below ground level exceeding 15cm complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate for pole / struts foundation etc all as specified and directed.
M&L for PCC 1:2:4 type C1 using 20mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete all as specified and directed.
Supply and joint in replacement of cable jointing kit straight through joint epoxy type of size 10 sqmm 4 core to 16 sqmm 4 core all as specified and directed.
Supply and joint in replacement of cable jointing kit straight through joint epoxy type of size 25 sqmm 3.5 core to 50 sqmm 3.5 core all as specified and directed.
Supply and fixing in replacement of galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.
Supply, install, testing and commissioning in replacement of outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- OUTER SHELL : The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54.
INNER SHELL : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing MCCBs and TPN copper busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming : MCCB 500 Amps, 4 pole, 415 Volts, 50 Hz ICU 50 KA thermally adjustable between 70-100% - 01 No. (b) Outgoing : (i) MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz ICU 25 KA thermally adjustable between 70-100% - 03 Nos. (ii) MCCB 160 Amps, 4 pole, 415 Volts, 50 Hz ICU 25 KA thermally adjustable between 70-100% - 02 Nos. (iii) MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz ICU 16 KA thermally adjustable between 70-100% - 02 Nos. (ii) MCB 32 Amps, Triple pole & Neutral, 415Volts, 50 Hz ICU 10 KA - 01 No.
Supply and fix cross arms. Bracings, support channel, backpate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of PVC insulated 3 core 1.5 sqmm multistranded (un armoured 2XY) copper conductor complete all as specified and directed.
Taking down written shut down from concerned JE/AGE (E/M) for trimming of tree branches touching to the LT/HT over head line or near to the LT/HT over head line as per the direction of AGE E/M/JE incharge complete including removing the tree branches from site complete all as specified and directed by Engr in Chatge. Note :(I) Span from one pole to next pole ( 30 to 50 RM) will be considered as a one Job. (ii) Any damage cause due to contractormen will be rectified without any extra payment. (ii) T & P such as ladder,rope,cutter,Axes and other related material will be provided by the contractor.
M&L for repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and all drop bolt complete and painting with two coat of synthetic enamel paint of approved color internally and externally all as specified and as directed by Engineer-in-Charge. Note : (i) Rate for requisite stores i.e. hinges, welding rods, paint, primer, included in this item rate. (ii) All type T&P i.e. welding machine at site, compressor for spray paint etc. included in this item. (iii) If Panel repair work has not been started by the Contractor after receiving of site order from Engr-in-Charge, Penalty for Rs. 500.00 per day has been recovered from the Contractor.
M&L for preparation of surfaces for LT pole painting by scrapping damaged paint and painting with two coats of silver aluminium paint and writing pole No with black paint on yellow circuit all as directed by Engineer-in-Charge. Note : If pole No not written by Contractor after Silver aluminium paint, recovery of Rs. 150.00 Rs. will be restricted in this item rate.
M&L for taking out old unserviceable MCCB TP/TPN four pole from existing LT panel board and supply and fix MCCB TP 63 amps capacity, rup capacity 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed.replacement of brunt lugs and wire/cable pieces etc as required at site.
All as per Item No.39.00 above but 100 amps capacity, 25 KA complete all as specified and as directed by Engineer -in-Charge
All as per Item No.39.00 above but 200 amps capacity rup capacity 35 KA complete all as specified and as directed by Engineer -in-Charge
All as per Item No.39.00 above but 315 amps capacity rup cap 35 KA at 415 volt complete all as specified and as directed by Engineer -in-Charge
Supply and fix in repairs Voltmeter 0-500 volt, 4 modules, complete with necessary fixing all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs ammeter 0-250 amps, 4 modules, with CT operated complete with necessary fixing all as specified and as directed by Engineer-in-Charge.
M&L for replacement of jump connection by using ACSR conductor weasel, alkathine pipe, aluminium lugs, PG clamps, nuts, bolts etc. all as directed by Engineer-in-charge.
Supply and fix in repairs indicator lamp (Red, Yellow, Blue) complete with necessary fixing all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of motor starter panel made out of 3 mm thick CRCA sheet steel enclosure with front openable door (with locking arrangement and making compartment for MCCB separately) suitable for IP 65 out door type powder coated with 4 Nos 200 A rated copper bus bar adequate length fixed over including 4 nos insulators, all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland) incl necessary angle iron support by using MS angle iron 40 x 40 x 4 mm thick consisting of the following item with pre wired suitable size copper conductor incl fixing arrangement all as specified and as directed. (Note : Rate included for necessary PCC work for fixing of panel will be measured and paid in this item) (a) MCCB 63 Amps FP, 25 KA - 01 No (b) Time switch with contactor and required spares - 01 Nos (c) DOL starter 3 pole MK 1.5 suitable for 3 HP pump set - 01 Nos (d) Indicator lamp RYB - Set of 3 (e) Digital Volt meter 0 -500 Volt - 01 No (f) Digital Ammeter 0-30A - 01 No (g) Over load relay - 01 Nos (h) Danger Notice board - 01 Nos (j) MCB SP 32A - 01 No
Supply and fixing in replacement of RCC cable route marker/ indicator of size 0.30mtr x 0.10 mtr x 0.90 mtr complete including painting with one coat of primer and two coat oil paint as per colour coding specified by Engineer-in-Charge for exposed surface, excavation, PCC, etc included in this item rate complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of main switch of 200 Amp capacity complete including fixing arrangement all as per specified and directed by Engr in Charge.
M&L for replacement Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for LT underground cables suitable for 0.4 Mpa working pressure complete all as specified and directed.
Supply, install, testing and commissioning in replacement of outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- OUTER SHELL : The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54.
INNER SHELL : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing MCCBs and TPN copper busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming : MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz ICU 35 KA thermally adjustable between 70-100% - 01 No. (b) Outgoing : (i) MCCB 125 Amps, 4 pole, 415 Volts, 50 Hz ICU 25 KA thermally adjustable between 70-100% - 03 Nos. (i) MCCB 63 Amps, 4 pole, 415 Volts, 50 Hz ICU 10 KA thermally adjustable between 70-100% - 03 Nos. (ii) MCB 32 Amps, Triple pole & Neutral, 415Volts, 50 Hz ICU 10 KA - 01 No.
Supply and fix junction box of Size 250 x 200 x 100mm complete with industrial connector including clamps made out of MS flat iron 30 x 5mm and suitable MCB as specified and directed.
All as per Item No. 54.00 but Size 185 x 165 x 60 mm.
NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS.2,41,615.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
DHARMESH ENTERPRISES
Rama Electricals
M/s Ravi Electrical
sapana enterprises
DURGAI ELECTRICALS
Shining Star Electricals
Bidder Name
DHARMESH ENTERPRISES
sapana enterprises
MAHIMA CONSTRUCTION
Rama Electricals
DURGAI ELECTRICALS
M/s Ravi Electrical
Shining Star Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .