Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.0 LAccepted-AOC | 1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | 2₹29.6 L+₹54,448.40 (1.88%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 2 | Rejected-Finance REJECTED BEING NOT L1 | |
| 3 | 3₹30.6 L+₹1.6 L (5.62%)Rejected-Finance | 3 | Rejected-Finance REJECTED BEING NOT L1 | |
| 4 | 4₹31.8 L+₹2.8 L (9.49%)Rejected-Finance | 4 | Rejected-Finance REJECTED BEING NOT L1 | |
| 5 | 5₹33.0 L+₹4.0 L (13.6%)Rejected-Finance 00 BACHUAPAR RAJESULTANPUR ALAPUR AMBEDKAR NAGAR UTTAR PRADESH 224176 | AMBEDKAR NAGAR | UTTAR PRADESH | 224176 | 5 | Rejected-Finance REJECTED BEING NOT L1 |
| Sl No | Description | Qty | Unit | Vijay Electricals L2 | MV Engineers And Contractors L6 | Rajindera Enterprises L1 | ALLIED CONSTRUCTION L3 | DS CONSTRUCTION L4 | KISHORE ENTERPRISES L8 | Powerlite Engineers L7 | SB ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Eng-in-Charge.
Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule.
(b) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
(c) PCC cable Cover shall be paid separately.
(d)Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done. | 48 | Each Job | 5,000 ₹2,40,000 | 5,500 ₹2,64,000 | 4,500 ₹2,16,000 | 4,000 ₹1,92,000 | 5,000 ₹2,40,000 | 3,500 ₹1,68,000 | 2,200 ₹1,05,600 Lowest | 5,099 ₹2,44,752 |
| 2.00Supplying and laying in assorted piece/ Sizes of 8 to 10 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available towards rectification of cable faults, laying, jointing and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of the following cable sizes, 11 KV grade (earth) for 11 KV (E) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed by Engr-in-Charge of following sizes :- | |||||||||||
| 2.01 | 3 core 300 Sq mm | 60 | RM | 1,000 ₹60,000 | 1,100 ₹66,000 | 600 ₹36,000 Lowest | 900 ₹54,000 | 1,500 ₹90,000 | 1,699 ₹1,01,940 | 1,700 ₹1,02,000 | 1,199 ₹71,940 |
| 2.02 | 3 core 240 Sq mm | 50 | RM | 900 ₹45,000 | 900 ₹45,000 | 500 ₹25,000 Lowest | 800 ₹40,000 | 1,300 ₹65,000 | 1,599 ₹79,950 | 1,500 ₹75,000 | 1,199 ₹59,950 |
| 2.03 | 3 core 185 Sq mm | 150 | RM | 800 ₹1,20,000 | 700 ₹1,05,000 | 400 ₹60,000 Lowest | 750 ₹1,12,500 | 1,100 ₹1,65,000 | 1,299 ₹1,94,850 | 1,200 ₹1,80,000 | 1,089 ₹1,63,350 |
| 2.04 | 3 core 120 Sq mm | 100 | RM | 700 ₹70,000 | 600 ₹60,000 | 300 ₹30,000 Lowest | 700 ₹70,000 | 820 ₹82,000 | 699 ₹69,900 | 900 ₹90,000 | 599 ₹59,900 |
| 3.00 | Material & labour for complete jointing and testing, indoor end termination heat shrinkable type joint, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm against Joint Failures complete all as specified and directed by Engr-in-Charge. | 12 | Each Job | 1,500 ₹18,000 | 1,300 ₹15,600 | 1,500 ₹18,000 | 3,000 ₹36,000 | 3,000 ₹36,000 | 2,500 ₹30,000 | 1,900 ₹22,800 | 999 ₹11,988 Lowest |
| 4.00 | All as per srl item No -3- here -in-before but size of 3 core,120 to185 sqmm complete all as specified and directed by Engr-in-Charge. | 10 | Each Job | 1,500 ₹15,000 | 1,300 ₹13,000 | 1,500 ₹15,000 | 3,000 ₹30,000 | 3,000 ₹30,000 | 2,500 ₹25,000 | 1,750 ₹17,500 | 999 ₹9,990 Lowest |
| 5.00 | Material and labour for complete jointing and testing, outdoor end termination heat shrinkable type joint, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 Sqmm against joint Failures complete all as specified and directed by Engr-in-Charge. | 12 | Each Job | 1,500 ₹18,000 | 1,300 ₹15,600 | 1,500 ₹18,000 | 3,500 ₹42,000 | 3,000 ₹36,000 | 2,500 ₹30,000 | 2,100 ₹25,200 | 999 ₹11,988 Lowest |
| 6.00 | All as per srl item No -5- here -in-before but size of 3 core,120 to 185 sqmm complete all as specified and directed by Engr-in-Charge. | 10 | Each Job | 1,500 ₹15,000 | 1,200 ₹12,000 | 1,500 ₹15,000 | 3,500 ₹35,000 | 3,000 ₹30,000 | 2,500 ₹25,000 | 1,900 ₹19,000 | 999 ₹9,990 Lowest |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
6 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
REPAIR REPLACEMENT TO FAULTY DAMAGED 11 .415 KV CABLES WITH CABLE END TERMINAL ALONG WITH CONNECTED WORKS FOR SFC CGDA NIDEM OTM I II III HQ NSB II BANA SINGH 180 QTR UPPER SHANKAR VIHAR8 HQ 35 INF BDE TARAPUR ENCLAVE IN THE AREA OF AGE U
2025_MES_708644_1
GE ELECT/D-16/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹95,000
Yes
11 Aug 2025
16 May 2025
9 Jun 2025
16 May 2025
6 Jun 2025
30 May 2025
Amount
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Eng-in-Charge. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (c) PCC cable Cover shall be paid separately. (d)Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done.
Supplying and laying in assorted piece/ Sizes of 8 to 10 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available towards rectification of cable faults, laying, jointing and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of the following cable sizes, 11 KV grade (earth) for 11 KV (E) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed by Engr-in-Charge of following sizes :-
3 core 300 Sq mm
3 core 240 Sq mm
3 core 185 Sq mm
3 core 120 Sq mm
Material & labour for complete jointing and testing, indoor end termination heat shrinkable type joint, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm against Joint Failures complete all as specified and directed by Engr-in-Charge.
All as per srl item No -3- here -in-before but size of 3 core,120 to185 sqmm complete all as specified and directed by Engr-in-Charge.
Material and labour for complete jointing and testing, outdoor end termination heat shrinkable type joint, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 Sqmm against joint Failures complete all as specified and directed by Engr-in-Charge.
All as per srl item No -5- here -in-before but size of 3 core,120 to 185 sqmm complete all as specified and directed by Engr-in-Charge.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 33 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Engr-in-Charge. Note: (a) 33 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (c) PCC cable Cover shall be paid separately. (d) Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp. The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs, a penalty of Rs. 1000/Hrs will be recovered, fault will be rectified by the other contractor /vendor under Risk & Cost by deducting the rectification cost / cost as finalised by the accepting officer with penalty from the work done.
Supply, laying, jointing and testing in assorted piece/ Sizes of 8 to 10 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available towards rectification of cable faults, XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of sizes 3 Core, 300 to 400 Sqmm, 33 KV grade (earth) for 33 KV (E) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed by Engr-in-Charge.
Material & labour for complete jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 33 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 300 to 400 Sqmm complete all as specified and directed by Engr-in-Charge.
(a) Against joint failures.
(b) Against breakdown /damages.
Material and labour for supply, jointing and testing, outdoor end termination heat shrinkable type joint , suitable for HT, 33 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 300 to 400 Sqmm against joint failures complete all as specified and directed by Engr-in-Charge.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 V LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Engr-in-Charge. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (c) PCC cable Cover shall be paid separately. (d) Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done.
Material and labour for laying LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, in assorted piece/ Sizes of 8 to 10 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available towards rectification of cable faults,and of complete lengths as required for laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed by Engr-in-Charge of following sizes :-
3.5 core, 35 sqmm
3.5 core, 50 sqmm
3.5 core, 70 sqmm
3.5 core, 95 sqmm
3.5 core, 120 sqmm
3.5 core, 150 sqmm
3.5 core, 185 sqmm
3.5 core, 240 sqmm
3.5 core, 300 sqmm
Material & labour for excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out complete all as specified and directed by Engr-in-Charge.
Material & labour for returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Material & labour for removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by Engr –in-Charge. Note : Measurement shall be taken after punning down.
Supplying & laying in replacement un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and directed by Engr-in-Charge.
Laying only old HT cable cover obtained from excavation complete all as specified and directed by Engr-in-Charge.
Supplying & laying in replacement reinforcement precast cbale cover class LV Type-1 Flat size 250x150x40mm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Laying only old LT cable cover obtained from excavation complete complete all as specified and directed by Engr-in-Charge.
Material & labour for complete Jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm complete all as specified and directed by Engr-in-Charge.
(a) Against joint failures.
(b) Against breakdown /damages.
Material & labour for complete Jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 120 to 185 Sqmm complete all as specified and directed by Engr-in-Charge.
(a) Against joint failures.
(b) Against breakdown /damages.
Material & labour for jointing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade of size 16 to 35 Sqmm x 3.5 / 4 core complete all as specified and directed by Engr-in-Charge.
(a) Against joint failures.
(b) Against breakdown /damages.
All as per srl item No23 here -in-before but size of 50 to 70 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
(a) Against joint failures.
(b) Against breakdown /damages.
All as per srl item No 23 here -in-before but size of 120 to 185 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
(a) Against joint failures.
(b) Against breakdown /damages.
All as per srl item No 23 here -in-before but size of 240 to 300 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
(a) Against joint failures.
(b) Against breakdown /damages.
Supplying and laying LT UG Cable in replacement LT cable of PVC sheathed XLPE cable armoured aluminium conductor 1100 V graded, after taking out/down old existing unserviceable from trenches / ducts/ road crossing and poles complete all as specified and directed Against Re Routing / diversion from residential buildings and restricted area / Cable insulation Failure of break down for making straight through joint complete all as specified and directed by Engr-in-Charge of following sizes :- Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately.
3.5 core, 35 sqmm
3.5 core, 50 sqmm
3.5 core,150 sqmm
3.5 core,185 sqmm
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) Location: Banasingh Md Accn (Bldg No P-331) INCOMING :- (i) MCCB 4 pole 415 V breaking cap 36 KA , current rating 400 Amps. - 01 Nos, with microprocessor release - 01 Nos, Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 600 Amp, 4 pole, mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set
OUTGOING :- (i) MCCB 4 pole 415 V breaking cap 25 KA, current rating 100 Amps - 07Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate /glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iv) Multifunctioning meter with communication ports RS 485/232 5 display class-1 - 01 set (iv) Indicating Lamps R Y B, LED type - 01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm (Location:OTM -III JCOs Mess) INCOMING :- (i) Incomer of the panel having MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 250/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 400 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set
OUTGOING :- (i) MCCB 4 pole 415 V breaking cap 16 KA, current rating 100 Amps - 02 Nos (ii) MCCB 4 pole 415 V breaking cap 16 KA, current rating 63 Amps - 03 Nos (iii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate /glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (v) Indicating Lamps R Y B, LED type - 01 set
M&L in replacement of Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron 25x4mm GI strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge.
Vijay Electricals (BID ID -3314324)
ALLIED CONSTRUCTION (BID ID -3315097)
DS CONSTRUCTION (BID ID -3315413)
SB ENTERPRISES (BID ID -3314813)
MV Engineers And Contractors (BID ID -3314371)
Powerlite Engineers (BID ID -3315479)
KISHORE ENTERPRISES (BID ID -3315475)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .