| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC | ₹4.1 L Quoted ₹4.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹4.9 L+₹48,600 (11.0%)Rejected-Finance | ₹4.9 L+₹48,600 (11.0%) | L2 | Rejected-Finance L2 |
| 3 | L3₹5.1 L+₹72,150 (16.4%)Rejected-Finance INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | ₹5.1 L+₹72,150 (16.4%) | L3 | Rejected-Finance L3 |
| 4 | L4₹5.4 L+₹94,510 (21.4%)Rejected-Finance 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | ₹5.4 L+₹94,510 (21.4%) | L4 | Rejected-Finance L4 |
| 5 | L5₹5.4 L+₹97,000 (22.0%)Rejected-Finance D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | ₹5.4 L+₹97,000 (22.0%) | L5 | Rejected-Finance L5 |
Tender Value
₹10.5 L
EMD Value
₹21,000
Closing Date
25 Sept 2021, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR OF INTERNAL ELECTRIC WIRING CEILING FANS EXHAUST FAN DBS MCCBS CFL FITTINGS LAMP WITH LED LIGHTS AND CONNECTED WORKS AT AF STN DADRI
2021_MES_472981_1
GE (FBD)/AF-40/2021-2022
Open Tender
Civil Works
Item Rate
180 days
AF STATION DADRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹21,000
Yes
14 Oct 2021
4 Sept 2021
2 Oct 2021
4 Sept 2021
25 Sept 2021
13 Sept 2021
6 Sept 2021 - 11 Sept 2021
Amount
Taking down carefully aluminium point wiring/sub main wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with MS conduit and T/W battern and depositing to MES store yard complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and as directed by Engineer-in-Charge for following (Color coding to be followed) :- (a) One light/fan point controlled by one switch.
All as per item No 02 above but One socket point on same board with other switches complete all as specified and as directed by Engineer-in-Charge.
All as per item No 02 above but One 3 pin 5 Amps socket outlet independent with cables 1.5 sqmm size complete all as specified and as directed by Engineer-in-Charge.
All as per item No 02 above but One bell/buzzer point controlled by one bell push complete all as specified and as directed by Engineer-in-Charge.
All same as per item No 02 above but with conductor of size 2.5 Sq mm (nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 1.5 Sq mm PVC insulated stranded copper conductor cable complete all as specified and as directed by Engineer-in-Charge.
M&L for switch piano type 5 Amps, single pole one way complete all as specified and as directed by Engineer-in-Charge.
M&L for switch piano type 15 Amps, single pole one way complete all as specified and as directed by Engr-in-Charge.
M&L for socket outlet 2 in 1, 3 pin, 5 and 15 Amps Flush type complete all as specified and as directed by Engr-in-Charge.
M & L for socket outlet 5 pin , 5 Amps flush type complete all as specified and as directed by Engineer-in-Charge.
S & F stepped type electronic fan regulator flush type all as specified and directed by Engineer-in-Charge.
S&F in repair call bell ding dong type 230 volt single phase complete set inclusive suitable size wire from ceiling rose to calling bell complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement lamp holder insulated body threaded deme, with back plate,button/ angular type with sutable for battern fitting complete all as specified and as directed by Engineer-in-Charge.
S&F for ceiling rose surface bakelite 65x50mm two to three terminals complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring with modular single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and as directed by Engineer-in-Charge.
M&L for Re wring with Modular /single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit / cassing capping / concelled as per ground requirement medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and as directed by Engineer-in-Charge.
S&F Modular switch 1 way 6A, 1 module complete all as specified and as directed by Engr-in-Charge.
S&F Modular switch 1 way 16A, 1 module complete all as specified and as directed by Engr-in-Charge.
S&F Modular Bell push 6A 1 module complete all as specified and as directed by Engr-in-Charge.
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-Charge.
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-Charge.
S&F White cover plate with frame,1 module complete all as specified and as directed by Engr-in-Charge.
All same as per item No 22 above but but 3 module complete all as specified and as directed by Engineer-in-Charge.
All same as per item No 22 above but but 6 module complete all as specified and as directed by Engineer-in-Charge.
All same as per item No 22 above but but 8 module complete all as specified and as directed by Engineer-in-Charge.
S&F Metal flush box/ PVC box 1/2 module complete all as specified and as directed by Engr-in-Charge.
All same as per item No 26 above but but 3 module complete all as specified and as directed by Engineer-in-Charge.
All same as per item No 26 above but but 6/8 module complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose , complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable and tubes wit suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Sub main wiring with four single core, 10 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 2 x6 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and as directed by Engineer-in-Charge.
Sub main wiring with four single core, 6 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 2 x4 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and as directed by Engineer-in-Charge.
Sub main wiring with two single core, 6 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x4 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and as directed by Engineer-in-Charge.
Sub main wiring with two single core, 4 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x 2.5 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and as directed by Engineer-in-Charge.
S & F MCCB 4 pole 40 Amps 16 kA complete all as specified and as directed by Engineer-in-Charge.
S& F fixing MCB TPN 63 A C Series Amps complete all as specified and directed by Engineer-in-Charge.
S& F fixing MCB SPN 40 A C Series Amps complete all as specified and directed by Engineer-in-Charge.
S& F fixing MCB SP 6- 32 A B series Amps complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Edgelit LED slim panel light fitting 2'x2' 40 watt having powder coated extruded Aluminium body with high quality LGP and PMMA diffuser swparate HPF driver suitbale for Armstrong and grid ceilling 6000 K , including connecting up with twin core twisted flexible copper cable with suitable size complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully water heater storage type 25/50 Ltrs capacity for repair and over hauling and opening to gysers and comprising of heating element , thermostate switch, electric connetions cleaning and descaling with descaling solution the geyser tank and checking of leakage on pressure at 150 PSI and testing for smooth fuctioning complete all as sepecified and directed by Engr -in-Charge
S & F in Replacement of heating element suitable for geysers any type as site requirement ISI mark complete all as specified and directed by Engr - in- charge.(a) 2.00 KW Capacity 230 Volts
All as per item ser No 38 above but (b) 1.50 KW Capacity 230 Volts complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement thermostat switch any type suitable for geyser of any size/model complete all as specified and as directed by Engineer-in-Charge.
S & F Geyser assy ( rupturing plate or U assembly) any make and type for 50 Ltrs capacity water heater incl replacement of rubber seal nuts and bolts complete all as specified and as directed by Engineer-in-Charge.
All as per item no 44 above but for 25Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of indcation lamp (pilit type ISI marked) for 50 / 25 Ltrs water heater complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC insulated flexible copper conductor cable 40/0.0076 size 3 core suitable for 650 volts grade complete all as specified and directed by Engr - in- charge.
S&F in replacement of glass wool in any capacity of geyser complete all as specified and directed by Engr - in- charge.
S&F in replacement of water storage tank of geyser suitable for 50 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
All as per item ser No 49 above but for 25 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
M & L for repair welding brazing of copper tank upto 25 mm to 10mm long leak proof complete all as specified and as directed by Engineer-in-Charge.
S & F in Replacement of bottom cover suitable cylindrical type geyser as per existing ad required at site for the following size complete all as specified and as directed by Engineer-in-Charge. (a) 50 Ltrs capacity
All as per item No 52 above but 25 Ltrs Capacity complete all as specified and as directed by Engineer-in-Charge.
S & F Recess mounted LED Light Fitting 15 Watt pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and incl separate replaceable electronic driver compatible for Analog/DALI Dimming complete all as specified and as directed by Engineer-in-Charge.
S & F Electronic drivers suitable to fix Recessed mounted LED Light Fitting 15 Watt round shaped complete all as requred on site for smooth functioning of lights complete all as specified and as directed by Engineer-in-Charge.
S & F Electronic drivers suitable to fix Recessed mounted LED Light Fitting 2'x2' 40Watt 6000 K/5400K completemake and model all as requred on site for smooth functioning of lights complete all as specified and as directed by Engineer-in-Charge.
36SHRI RADHEY ASSOCIATES
KRISHANA ELECTRIC WORKS
s r enterprises
GARG CONSTRUCTION CO
M/S Anand Enterprises
Singh Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .