Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹52.1 L+₹2.1 L (4.19%)Rejected-AOC WZ143 A 7 A S 4 43 GALI NO 2 OLD MAHABIR NAGAR NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹52.6 L+₹2.6 L (5.29%)Rejected-AOC 1 204 LOWER GROUND FLOOR SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹53.0 L+₹3.0 L (6.02%)Rejected-AOC C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L4 | Rejected-AOC Neither lowest nor competitive | |
| 5 | L5₹53.2 L+₹3.2 L (6.35%)Rejected-AOC | L5 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
1 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
CA NO GE/C-14/2021-22 PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-I AGE B/R-II AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2021_MES_442142_1
GE/C-14/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt-10
₹99,000
Yes
19 Jun 2021
11 May 2021
3 Jun 2021
11 May 2021
1 Jun 2021
26 May 2021
11 May 2021 - 26 May 2021
60 days
Amount
Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including reinforcement required to facilitate demolition upto and including fourth story and on the roof top/mumty/parapet and removal of debris and rubbish out side MoD land complete all as specified and directed by Engineer -in-Charge .
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed by Engineer -in-Charge .
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed by Engineer -in-Charge .
Dismantling of PVC water tanks of exc 250 litres and n.exc 500 litres capacity of any condition or type complete all as specified and directed by Engineer -in-Charge .
Dismantling of Cast Iron pipe/ RCC drain pipe/PVC pipe up to 100 mm bore complete all as specified and directed by Engineer -in-Charge .
Dismantling floor hearth or wall tiling including cement mortor bedding (but not backing) laid bedded and pointed in any mortar and removal of old tiles from premises complete all as specified and directed by Engineer -in-Charge .
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish,vegetation etc outside complex (MOD land) complete all as specified and directed by Engineer -in-Charge .
M&L for Brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed by Engineer -in-Charge .
M&L for Brick work with sub class 'B' bricks straight or curved on plan to any radious in half brick thick wall built in CM 1:4 complete all as specified and directed by Engineer -in-Charge .
M & L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement complete all as specified and directed by Engineer -in-Charge .
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with water proofing compound finished even and smooth without using extra cement complete all as specified. (Water proofing compound shall be measure and paid separatelly).
M & L for 15 mm thick internal rendering in cement mortar 1:6 on fair face of brick walls/ concrete surfaces & finished even and smooth without using extra cement, complete all as specified and directed by Engineer -in-Charge .
Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 Sqm each with shutters (without taking off shutters from frames) complete all as specified and directed by Engineer -in-Charge .
Taking down chowkats or frames not exc. 1.5 Sqm each with shutters (without taking off shutters from frames) complete all as specified and directed by Engineer -in-Charge .
Taking down shutters of any description exc 1 sqm and not exc 2 sqm each complete all as specified and directed by Engineer -in-Charge .
S&F Fiber Glass Reinforced Plastic (FRP) Door Frames of cross section 90x45mm having single rebate of 32x5mm to receive shutter of 30mm thick. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer -in-Charge . .
S&F 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardantgrade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames complete all as specified and directed by Engineer -in-Charge .
M & L framed work such as grills, grating etc with ends of bars shouldered or riveted or forged into spikes framed guard bars, railing and similar work confirming to Fe - 290-0 or E-165 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer -in-Charge .
S&F 30mm thick factory made flush shutters solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed by Engineer -in-Charge .
S & F 35mm thick 2nd class hard wood factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer -in-Charge .
M&L Factory made 2nd class hard wood glazed and skeleton shutter 35mm thick, factory made, open rebated and prepared to receive glass/guage etc, without sash bars, mitred and rebated, with edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/guage etc, sizes of members of shutter as specified in section 8, clause 8.24(a) of SSR Part I complete all as specified and directed by Engineer -in-Charge .
S&F powder coated aluminum frames for windows/ventilators with one or more rebates, Aluminium grills including jointing cleats for fixing etc complete all as specified and directed by Engineer -in-Charge .
S&F anodised aluminum powder coated glazed/gauzed windows and ventilators shutters three track sliding window without sash bar aluminum section weighing 0.65 kg per mtr including necessary jointing cleats glazing clips rubber packing anodised aluminum beading screws including all fittings and fixtures such as roller assembly, handle section for opening and closing of windows, three leaves of shutters including 5.50mm thick glass panes and stainless steel wire mesh complete all as specified.Note : The rates quoted by the contractor shall be entire completion of work as per the specifications. Net opening area to be measured for payment purpose. Nothing shall be paid extra complete all as specified and directed by Engineer -in-Charge .
S&F white colour Rotational moulded polyethylene water storage tank 1000 litres capacity, ISI marked triple layer construction (cylindrical vertical closed top), hoisted & fixed in position all fittings incl 02 Nos of Gate valves of 20mm dia and 20mm dia float valve complete all as specified and directed by Engineer -in-Charge .
S&F 25 mm thick flush shutter solid core construction with block board core and ply wood face panel commerical type on both side to be fixed as shutter of cupboard/kitchen cup board/loft board including two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer -in-Charge .
S&F 100 mm long (size) butt hinges, medium weight, cold rolled mild steel, complete all as specified and directed by Engineer -in-Charge .
S&F 75 mm long (size) butt hinges, medium weight, cold rolled mild steel, complete all as specified and directed by Engineer -in-Charge .
S&F 300mm long, Aluminium anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts complete all as specified and directed by Engineer -in-Charge .
S&F in repair aluminium anodised grade barrel tower bolt 200 mm long, extruded section complete all as specified and directed by Engineer -in-Charge .
S&F aluminium anodised barrel tower bolt 200 mm long , extruded sections complete all as specified and directed by Engineer -in-Charge .
S&F extruded aluminium alloy handle of size 150mm size long complete all as specified and directed by Engineer -in-Charge .
S&F in repair 300mm long, Aluminium anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts complete all as specified and directed by Engineer -in-Charge .
S&F Aluminium anodised floor door stopper with hard drawn steel spring 140mm long complete all as specified and directed by Engineer -in-Charge .
M&L for cutting chases on brick or concrete surface for concealed water tubing or girth n.exc 10cm including making good of disturved surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed by Engineer -in-Charge .
Taking up or down 15 mm bore GI tubing and connections including cleaning for re-fixing complete all as specified and directed by Engineer -in-Charge .
All as per item No. 35 above but 20 mm bore
M&L Preparation of new or previously untreated wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer -in-Charge .
M&L Granite of 18 to 20mm thick with uniform texture (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like in cement mortar (1:4) including pointing with white cement (1:2) using marble dust with admixture of pigment to match with marble shade of makrana doogri green colour stone for Kitchen cooking platform laid over and including 15mm thick screed bed in cement mortar (1:6) polishing bevelled edges of corner etc complete all as specified and directed by Engineer -in-Charge .
M&L for complete removal of existing treatment of wall and applying two coat of plastic emulson paint including preparation of old surfaces over birla white chalk whitening, complete all as specified and directed by Engineer -in-Charge .
M&L POP cornice 75mm to 100mm thick as per design/moulding as approved by Engr-in-charge in corner of ceiling incl two coats of oil bound distemper complete all as specified and directed by Engineer -in-Charge .
S&F in Soft closing ball bearing telescopic channel of size 22 inch long fixed with screws in cupboards incl all fittings complete all as spd and directed by Engr in charge.Note : Runner/ Channel should be SS 304 grade and load capacity should not be less than 45 kgs complete all as specified and directed by Engineer -in-Charge .
“S&F Modular Cabinet Kitchen accessories of Stainless Steel grade-304,6mm size rod thickness including :- (i) Perforated Cutlery basket, (ii) Grain trolley, (iii) Thali basket, (iv) Cup & saucer basket, (v) Glass basket, (vi) Plate basket, (vii) Premium magic corner (viii) Oil Pull out Tray ( Triple basket layer) of size as per site requirement all spd and directed by Engr in charge
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18 mm and fixed with steel wire staples, complete all as specified and directed by Engineer -in-Charge .
S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18 mm and fixed stainless steel wire staple, complete all as specified and directed by Engineer -in-Charge .
S&F 5.5 mm thick sheet glass ordinary quality in square n.exc 0.5 Sqm each including grinding of edges for crockery cupboard including taking out/ broken glass with roller, complete all as specified and directed by Engineer -in-Charge .
S&F in repair vitreous China coloured European type WC with (single piece) wall / floor mounted including Vitreous china coloured 10 ltrs capacity cistern connection to drain,'P' trap or S trap and fixing bolts ,plastic water closet seat cover complete all as specified and directed by Engineer -in-Charge . .
S&F in repairs vitreous chinaware coloured wall hung wash hand basin with full pedestal of size 550mm x 480mm complete including , CP Waste coupling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed by Eng in charge.Make Cera New Cat No: S2040115 Wash basin S2090111 Pedestal or Equivalent
S&F drapery curtain rods extruded aluminum section anodized in gold , copper or antique silver 25 mm nominal dia of approved quality with two number decorative brackets of cast iron or stainless steel ( weight not less than 200grams each bracket) and latto on both sides of Cast iron or stainless steel (weight of each Latto not less than 100 grams each) design as approved by GE fixed in brick/concrete wall with same finished knobs/latto on each end of curtain rodcomplete all as specified and directed by Engineer -in-Charge .
S&F Mild steel TMT bars of 10 mm dia and over cut to length bent to shape required including cranking, bending etc and S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer -in-Charge .
M&L for providing reinforced cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in kitchen slab, Chajjas, lintels complete all as specified and directed. Note : The rate quoted by the contractor is deemed to include the necessary scafoldings, supports etc. Nothing extra will be claimed on this account. The work will be executed upto G+3 Storyes building.The form work will be measured and paid separately under respective items complete all as specified and directed by Engineer -in-Charge . .
S&F Form work to sides and soffits of shelves etc including supports such as kitchen shelves, platforms and similar works rough finish surface of concrete (the thickness of slab/shelves n.exc. 100 mm) complete all as specified and directed by Engineer -in-Charge .
M&L Cement concrete 1:2:4 type B1(using 20mm graded crushed stone aggregate) as in bed blocks for hold fast, coping, benching etc. including weathering, slightly rounded or chamfered angles or throating including form work to concrete surfaces complete all as specified and directed upto two storey height.
M&L Non skid Coloured ceramic rectified tile 300x300x7-8 mm thick as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer -in-Charge .
M&L Coloured ceramic rectified tiles 300x600 x 7 to 8mm thick, as in vertical surfaces of wall such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 10mm thickbacking coat in CM 1:4 complete all as specified and directed by Engineer -in-Charge .
M&L Coloured ceramic rectified tiles 600mm x 600mm x10 mm thick , joint free as in floors over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer -in-Charge .
M&L Coloured glazed ceramic rectified tiles 600 mm x 600 mm x 10 mm thick as in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed by Engineer -in-Charge .
S&F 15mm bore GI tubing medium grade with all fittings and fixed to wall and ceiling or laid in floors etc complete all as specified and directed.Note :-The pipe shall be painted with bituminous paint of approved quality and the pipes should not come in contact with lime mortar or lime concrete as pipes are affected by lime etc complete all as specified and directed by Engineer -in-Charge . .
All as per item No 58 above but 20 mm bore.
S&F white colour Rotational moulded polyethylene water storage tank 500 litres capacity, ISI marked triple layer construction (cylindrical vertical closed top), hoisted & fixed in position all fittings incl 02 Nos of Gate valves of 20mm dia and 30mm dia float valve complete all as specified and directed by Engineer -in-Charge .
S & F Brass CP basin mixer for mixing hot & cold water screwed down for iron pipe 15 mm bore, screwed down high pressure, screwed for iron pipe and fixed complete all as specified and directed by Engineer -in-Charge .
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracked guard and railing 60 cm long complete all as specified and directed by Engineer -in-Charge .
S&F stainless steel sink AISI 316 grade without drainage board of 1 mm thick kitchen or laboratory with plug , washer and waste, 15mm bore brass Chromium plated sink mixer for mixing hot and cold water, bedding in cement morter to dwarf wall or including CP Waste , PVC Down pipe etc and fixing cantilever brackets and connecting union to pipe overall size495mmx 420mm bowl size 410mm x330mm x160mm etc complete all as specified and directed by Engineer -in-Charge .
S&F stainless steel kitchen plate rack 1 mm thick four shelves made out of stainless steel sheets 1 mm thick over all size 1.20x90x25cm complete all as specified and directed by Engineer -in-Charge . .
S&F in repairs 15 mm bore Angle valve cast copper alloy Chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed by Engineer -in-Charge .
S&F wall mixture 15 mm bore cast copper alloy Chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed by Engineer -in-Charge .
S&F in repairs 15mm bore bib taps fancy type of Chromium plated high pressure screwed for iron pipe and fixed etc. complete all as specified and directed by Engineer -in-Charge .
S&F in repairs CP brass shower rose 150mm dia with chromium plated arm fixed to 15mm pipe of revolving type complete all as specified and directed by Engineer -in-Charge .
S & F 100mm dia (bore of pipe) cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified and directed by Engineer -in-Charge .
S & F 75 mm dia (bore of pipe) cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified and directed by Engineer -in-Charge .
S&F in repair 100mm dia (bore of pipe) cast iron Tee diminishing pieces or tapers (larger bore measured) with cement joints, complete all as specified and directed by Engineer -in-Charge .
All as per item 71 but 75mm dia (bore of pipe) Tee
S & F 75mm dia (bore of pipe) branch pieces single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, fitted with oval access door, complete all as specified and directed by Engineer -in-Charge .
All as per item 73 above but 100mm dia (bore of pipe).
S&F in repair cast iron floor trap square type with Cockroch Proofing CP grating with or without hole including provision of jointing to waste pipes in run lead joint dia of outlet 75 mm, complete all as specified and directed by Engineer -in-Charge .
M & L for roof treatment as per the description below :- a) Removing of existing water proofing treatment of APP complete all as directed including preparation of horizontal/vertical surfaces of brick/concrete /existing roof treatment roof surfaces also removing the , cleaning and washing down and make the surfaces free from dust and other conteminate b) Apply bituminous primer @ 0.3 ltr/Sqm (conforming to IS-3384) on prepared surfaces. After drying of primer apply a coat of hot blown 85/25 grade bitumen conforming to (IS 702 @ 1.2 Kg/Sqm of prepared surfaces. c) d) M&L for laying APP (Atatic polypropylene) modified five layered membrane 3 mm thick and weighing not less than 4 Kg/Sqm with centre core 160 GSM/Sqm, core reinforced and laid with 75 mm side overlap and 150 mm end lap. the membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as per the manufacturer specification and apply two coat of silver aluminum paint complete all as specified and directed by Enginner-in-Charge. .
M&L Cement concrete 1:2:4 type B0(using 12.5mm graded crushed stone agg) as in roof levelling complete all as specified and directed by Engineer -in-Charge .
M&L Cement concrete type B1-1:2:4 (using 20 mm graded crushed stone agg) in roof kerbs or mud stop rounded or chamfered on edge etccomplete all as specified and directed by Engineer -in-Charge .
M & L for 75 mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished fair and even without using extra cement, complete all as specified and directed by Engineer -in-Charge .
M&L for complete removal of existing treatment on surfaces of walls/ceilings by scrapping down with mechanical grinder on old walls as per the specification of manufacturers instructions of paints/OBD complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls complete all as specified and directed.
All as per item No. 81 above but on ceilings
M&L for applying of wall care putty on newly/old plastered walls of 2-3mm thick including preparing the surface with even and smooth complete all as specified and directed. (Note : Wall putty to be procured from manufactures directly)
M&L Preparation of newly/old plastered surfaces of walls and applying two coats of Oil bound distember on walls complete all as specified and directed by Engineer -in-Charge . .
M&L Preparation of newly/old plastered surfaces of walls and applying three coats of white wash on walls complete all as specified and directed by Engineer -in-Charge .
M&L Preparation of newly/old plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed by Engineer -in-Charge .
M&L for applying one coat of alkali resistent primer on already prepared surfaces of walls complete all as specified and directed by Engineer -in-Charge .
M&L Preparation of newly/old plastered surfaces of walls and applying two coats of Apex Ultima Protek exterior paint over two coat of base coat of apex ultima Protek on walls as per manufacturers instructions complete all as specified and directed by Engineer -in-Charge .
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and the sheet should be embedded in to the wall to a depth of 25mm and the surfaces to be plastered and made good ccomplete all as specified and directed by Engineer -in-Charge .
S&F MS work as in frame of door or gates of angle rafters; purlins fencing post and door frame where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and two coats of synthetic enamel paint over a coat of redoxide primer etc. conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer -in-Charge .
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil ,complete all as specified and directed by Engineer -in-Charge .
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outcomplete all as specified and directed by Engineer -in-Charge .
M and L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer -in-Charge .
M and L for 150 mm thick cement concrete type B-1 1:2:4 20 mm graded aggregate as in floor top 25 mm layer shall be mixed with metallic floor hardener as per manafectorer's instructions whilst concrete is green broom finishes laid over and including 150mm thick cement concrete type D-2 1:4:8 (40 mm graded ) concrete shall be laid in proper size bags size bags comlete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point soil Metallic floor hardener complete all as specified and directed by Engineer -in-Charge .
M and L for cement concrete type Dr ( 1:4:8) (40 mm graded ) as in foundations, filling and mass concrete complete all as specified and directed by Eng-in-charge
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc complete all as specified and directed by Engineer -in-Charge .
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and this like complete all as specified and directed by Engineer -in-Charge . .
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for columns, pillars, piers, post and strut complete all as specified and directed by Engineer -in-Charge .
M & L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface complete all as specified and directed by Engineer -in-Charge .
M & L for formwork to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for rough finished surface acomplete all as specified and directed by Engineer -in-Charge .
M & L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished surface complete all as specified and directed by Engineer -in-Charge .
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc.for fair finished surface complete all as specified and directed by Engineer -in-Charge .
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer -in-Charge .
All as per item no 50 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
M and L For Preparation of newly plastered surface of wall and applying two coats of cement base paint to achieve uniform and smooth surface having no sign of brush mark complete all as specified and directed
M& L for GI tubing 25mm bore complete all as specified and directed by Engineer -in-Charge . .
M and L for cement concrete type C-2 (1:3:6) (40 mm graded ) stone aggregate as in surface channels and drains complete all as specified and directed by Eng-in-charge
M & L for PCC 1:2:4 Type B-1 using 20 mm graded aggregate in surface channels and drains complete all as specified.
Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
M&L for Non-skid ceramic colour tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thickscreed bed or bedding layers in cement mortar(1:6) complete all as specified and as directed.
Dismentling plain or corrugated steel sheeting any gauge thickness including nainital or similar pattern roof covering complete all as specified and directed by Engineer -in-Charge .
S&F for 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc.complete all as specified and directed by Engineer -in-Charge .
Dismantling wrought iron or mild steel work of any description such as guard bars, grills etc complete all as specified and directed by Engineer -in-Charge . .
M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm stone graded agg) as in louversand jallies 40mm thick designed as fort pattern (measured solid) including all moulding but exceeding frame and set in CM1:4 all as per sample shown and directed by engineer-in -charge.
Dismantling of wall and ceiling board fibre pulp AC boards etc any thickness including cover fillets removing the wiring and refixing the same including fixture as necessary at site including frame work complete all as specified and directed by Engineer -in-Charge .
S&F factory made PVC kitchen and cupboard frame of the size 75mmx40mm with a wall thickness of 4mm, made out of extruded 4mm thick prelam PVC sheet reinforced with 15mmx15mm MS tube of 19 gauge thickness througout the fame and mitre cut at two corners and jointed with 2 Nos of 150mm long brackets of 10mmx10mm MS tubes.The door frame shall be fixed to the wall using 65/100mm long MS screw through the frame by using PVC fastners . A minimum of 4 Nos. of screws to be provided for each vertical member and minimim 2 Nos for Horizontal members Complete all as per manufacturers specifications and as directed
S&F wall mounted electric chimney 90 cm, 1200 Cum/h suction capacity filterless auto clean, one set complete all as specified and directed by Engineer -in-Charge .
M&L for aluminium alloy powder coated door including frame and channel of section (Door frame single grove 101.6mm x44.45 mm x2.1,shutter top section 47.62mm x44.45x1.95mm thick shutter bottem vertical section 85 mm x44045 mm x1.80mm yhick ,shutter middle section 83.50mm x 44.45 mm x1.80mm thick shutter glazing clips weighing not less than 0.097 kg/Rm incl as durected and approved by GE and as per IS specification including provn of 5.5mm thick tinted glass/12mm thick thick prelaminated particle board as required incl handle ,tower bolt ,floor spring heavy duty "SAMRAT" ,looking arrangement "GODREJ" rubber gasket and door stopper complete all as specified and directed by Engineer -in-Charge .
M&L aluminium alloy powder coated windows including aluminium coated frames silding track, bottom weighing not less than 1.015 kg/Rm ,sides and top not less than 0.826 kg/Rm double revated and 0.55 kg for window shutter with one fixed glazed shutter and two nos glazed/gauged shutter silding type with aluminium sectins as per series-A (15mm) 3 track of jindal section number for silding windowos with framed shutter including aluminium allow powder coated snap type beads handles with locking arrngement spring action and glazing clips joint cleats rubber gaskets etc inclding provision of 5.5 mm thick tinted glass/frosted glass of superior quality and stainless steel jail including all standard fittings complete all as specified and directed by Engineer -in-Charge .
M & L for preparation of old plastered surfaces of walls removal of surfaceing of existing layered of paint an and applying two coat of exterior emulsion acrylic weather coat paint (Apex) one coat of primer complete all as specified and directed.
S&F Cequered cement concrete tiles pu coated with grey cement and pigment 30cm X30cm X22mm thick set jointed and pointed in neat cement slurry in floors and including 75mm thick cement concrete type D-2 1:4:8 and incl 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer -in-Charge .
M&L for machine pressed precast concrete interlocking paver block 60mm thick M-35 grade any shape and size with grey cement and pigment over 25mm thick sand cushioning over and including 75mm thick cement concrete type D-2 1:4:8 complete all as specified and directed by Engineer -in-Charge .
Cutting holes inot or through cement concrete slabs, chajjas, etc reinforced or otherwise superficial area exc 100 Sqcm but n exc 250 Sqcm complete all as specified and directed by Engineer -in-Charge .
Excavating in post holes (or similar holes) each not exceeding 0.50 cum getting out, returning fittign in and ramming earth or brokenrubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B1 using 20mm aggregate in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, aprapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for complete all as specified and ddirected by Engineer-in-Charge
M&L mild steel plates (plain or chequered) channels square cut or notched (ordinary or counter sunk) formign holes, with riveted, bolted or welded attachement complete all as specified and directed by Engineer -in-Charge .
M&L applying two coats of syntheic enamel paint over a coat of red oxide on steel surfaces of any description ovoer 10 cm width or girth including preparation of new surfaces complete all as specified and directed by Engineer -in-Charge .
Cuting channels grooves or rebates n exc 15 cm girth, and trimming suface with reiforcement complete all as specified and directed by Engineer -in-Charge .
M&L 22 to 25mm thick chequered cement concrete tiles, set, jointed and pointed in near cements slurry in floors including 15mm thick screed bed in floor in C M 1:6 including cement concrete 1:2:4 type B-1 (20mm graded stone aggregate ) as in levelling complete all as specified and directed by Engineer -in-Charge .
Cutting channels, grooves or rebates n exc 15 cm girth, and trimming surface with reinforcement M7L for non skid ceramic tiles 7 to 8 mm (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 Sqm, in floors etc. set and jointed in ear cement slurry and pointed in white or coloured cement to mactch over 15 mm thick screed bed in cm 1.5 and 25cm thick cement concrete 1:2:4 type B0 using 12.50mm graded aggregate as in levelling course complete all as specified and directed by Engineer -in-Charge .
Expahanded metal,to length,bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members.
M&L FOR MS lat for roof sheets and brassing, incl securing bolt,drilling holes and washer /using ERW OR Induction butt welded ,complete all as specified and directed by Engineer-in-Charge.
Supply and fix 300mm long, mild steel, sliding door bolt matt finish snot less than 16 mm dia bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts extruded section or cast aluminum alloy, complete all as specified and directed by Engineer-in-Charge.
Supply and fix butt hinges, medium weight cold rolled mild steel 125 mm size welded to angle iron frames or fixed with screws to wooden frames complete all as specified and directed by Engineer-in-Charge..
M& L for Chequered cement concrete tiles 300cm x 300cm x 25mm thick, set, jointed and pointed in near cement slurry 20cmx20cm in floors including 15mm thick screed bed in cm(1:6) floor complete all as specified and directed by Engineer-in-Charge.
S&F chain link M S Galvanised fencing mild steel galvanised fencing complete all as specified & directed by Engr-in-Charge.
S&F 12mm mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n exc 5cm long complete all as specified & directed by Engr-in-Charge.
Providing and fixing 9mm thick designer ceiling board in ceiling fixed with screws as per manufactures instructions (Make : Everest) laid on hot dipped galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be under coated white. The frame shall comprise of main runner made from 0.33mm thick galvanized steel sheet & size of 24x32x300mm and spaced at 12mm centres securely fixed to the structural soffits by approved hangers at 1200 mm maximum centres. hangers of GI wire 4mm dia to be fixed by the approved rowl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200mm long cross tee with(double stitching) to be inter locked between main runners at 600mm centre to from 1200x600mm modules cross tee longer than 600mm modules to be formed by fitting 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanized steel of size 19x19mm and 300 mm long of white colour all as per instruction complete all as specified and directed by Engineer-in-Charge.
Supply and fix factory made solid PVC door Shutter, 30 mm thick (stiles), consisting of frame made of ms tubes for top and bottm rail,ms frame shall be covered with heat moulded plain colour PVC C channel having PVC sheet strip of 20mm with struck inside with solvent cement for stile and plain colour PVC sheet for top rail ,lock rail ,bottom rail and other side,& as gap inserted for toprail and bottm rail ,panelling of plain colour PVC sheet to be fitted on MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading ,and jointed together with solvent cement,fixing the frame at site as per specification and drawing in SSR part II
Supply and fix factory made PVC Chowkat/ Door frame (Make: Rajshri plastiwood laminated or equivalent) of size 50 X47 mm with a wall thickness of 5mm, made out of extruded 5mm thick single side prelam PVC sheet coloured, reinforced with 19 X 19 mm MS Square tube of 19 gauge including rubber gasket, PVC fasteners, screws, brackets complete all as specified and shown on drawing as per SSR 2004.
Supply and fix 200 mm long mild steel barrel tower bolt , complete all as specified and directed by Engineer-in-Charge.
Supply and fix extruded aluminum alloy handles fabricated type anodised of size 150mm long complete all as specified and directed by Engineer-in-Charge..
Supply and fix in repairs vitreous china wash hand basin (flat back) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15 mm dia Brass CP three-in-one wall mixer for mixing hot & cold with L band water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15 mm dia Brass CP WHB Mixer for mixing hot & Cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Material and labour for coloured glazed ceramic tiles 450x350 mm 7 mm thick in vertical surface set and jointed in neat cement slurry and pointing in coloured cement laid/fixed over 10 mm thick cement mortar (1:4) back coat complete all as specified and directed.
Supply and fix in repairs vitreous china squatting pan EWC pattern long pan size 580x440mm white with integral foot rests ‘P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe ) complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick work or concrete surfaces firnished een and smooth without using extra cement up to hieght of four storey ,including scaffolding complete all as specified and directed by Engineer-in-Charge.
M&L 75 mm PCC(1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floor and filling as mass conc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc complete all as specified and directed by Engineer -in-Charge . .
Taking down old SPN DBs, & AC enclosure box of any make and type from the site and making good surface complete all as specified and directed by Engineer -in-Charge .
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed by Engineer -in-Charge .
Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified and directed by Engineer -in-Charge .
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified.
One light /Ceiling fan/exhaust fan point controlled by one switch.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One bell point controlled by one bell push.
One light point controlled by two Nos two way switches
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts in New PVC concealed conduit in new M S steel terminal boxes modular including one run of using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, complete all as specified and directed by Engineer -in-Charge .
One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly complete (socket and switches to be measured and paid separately) complete all as specified and directed by Engineer -in-Charge .
M&L switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer -in-Charge .
M&L switch modular type 6 amp SP two way complete all as specified and directed by Engineer -in-Charge .
M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified and directed by Engineer -in-Charge .
M&L switch bell push Modular type 6 Amps 1W-1 module, 230V AC complete all as specified and directed by Engineer -in-Charge .
M&L switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer -in-Charge .
M&L Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer -in-Charge .
Supply & Fix Modular five stepped type electronic fan regulator 2 module 230V AC complete all as specified and directed by Engineer -in-Charge .
M&L bell electric (ding dong) 230 volt, SP complete all as specified and directed by Engineer -in-Charge .
M&L angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified and directed by Engineer -in-Charge .
S & F LED bulb 12 watts, 1200 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer -in-Charge . .
M&L for sub main wiring with two single core FRLS stranded copper conductor cable 1100 volts grade of size 4.0 sqmm and one single core FRLS stranded copper conductor cable 4 sqmm for earth wire in and including medium grade PVC concealed conduit with all fittings complete all as specified and directed by Engineer -in-Charge .
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 6 Sqmm size stranded conductor as earthwire complete all as specified and directed by Engineer -in-Charge .
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion complete all as specified and directed by Engineer -in-Charge .
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified and directed by Engineer -in-Charge .
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
M&L MCB SPN 40 Amp "C " curve complete all as specified and directed by Engineer -in-Charge .
M&L MCB SP 6 to 32 Amp "C" curve complete all as specified and directed by Engineer -in-Charge . .
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engineer -in-Charge .
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 900 lm system lumen output with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed by Engineer -in-Charge .
Supply and fix 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete.
Supply and fix surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engineer -in-Charge .
Supply and fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete all as specified and directed by Engineer -in-Charge .
Taking down carefully the existing ceiling fan of 1200mm from its position after disconnecting electric connection and deposits in MES Store complete all as specified and directed by Engineer -in-Charge .
Supply and fixing ceiling fans Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed .
S&f fresh air fan PVC body AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed by Engineer -in-Charge .
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 230 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed by Engineer -in-Charge .
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 10 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed by Engineer -in-Charge .
S&f exhaust fans AC single phase 230/240 V of size 300 mm sweep, metal body with louvre for fixing of exhaust fan complete all as specified and directed by Engineer -in-Charge .
M &L telephone Point wiring complete with single pin 0.61mm dia copper conductor cable telephone pain taped and rip conforming to ITD specification D-3003 and ITI-113C/114C cable PVC insulated drawn though PVC concealed conduit not less than 20 mm dia for one 2 pin telephone socket out let on independent modular type board complete all as specified and directed by Engineer -in-Charge . .
Supply & Fix in repair RJ-11 Telephone socket with transparent shutter 1 module on phenolic laminated sheet etc complete all as specified and directed by Engineer -in-Charge .
Taking down carefully the existing Exhaust fan of 300mm rom its position after disconnecting electric connection and deposits in MES Store complete all as specified and directed by Engineer -in-Charge .
S&f Wall mounted fans AC single phase 230/240 V, of size 400 mm sweep, speed RPM 1400,Sturdy and shock proof body for fixing of wall fan complete all as specified and directed by Engineer -in-Charge .
Taking down carefully the existing Geyser capacity 25 Ltr its position after disconnecting electric & water connection and after work refixing all as specified and directed.
Supply, and Fixing wall mounted angular Electric chimney black colour of suction power not less than 1220Cum/Hr,Al casette with stainless steel outer layer ,touch control panel,3 speed motor with 250 watt with decorative smart cooker hood SS and glass ,energy efficent Led light with digital display , including ducting not less than 10 feet as per site required complete all as specified and as directed by Engr-in-Charge
M&L switch piano flush type 5 Amp SP one way complete all as specified and directed by Engineer -in-Charge . .
M&L ceiling rose 3 phase PVC polycorbonate,isolated body complete all as specified and directed by Engineer -in-Charge . .
Supply and lay cable in replacement XLPE insulated screened PVC bedded, galvanized steel strip and wire armoured , electric power cables (heany duty) 1100 volts grade with stranded alumimium conductor of size 10 Sqmm 4 core.complete all as specified and directed by Engineer -in-Charge .
Supply and fix GI Pipe 32 mm dia light grade, for laying in road crossing/ fixing of vertically complete all as directed
Returning, filling in, including spreading levelling, watering and well ramming in layers not exc, 25cm depth in soft/loose soil complete all as specified and directed by Engineer -in-Charge . .
Supply and spreading clean dry sand in trenches for cushioning/cable protection complete all as specified and directed by Engineer -in-Charge .
Supply and laying sub clas 'B' Bricks of old size ( 23 x 11 x 7 cm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer -in-Charge
Supply and fix MCB DB SPN 4 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply & installation High Pressure Vehicle washing plant, single Phase 230 Volt, 50 Hz, working pressure 30 bar, flow rate 6-9 LPM with by pass return mechanism, including 20m pressure pipe, jetting nozzle, quick release coupling, suction filter & suitable size single phase electric motor coupled to pump with V belt and pulleys including common angle iron frame, motor stater and testing on complete all as specified and directed by Engineer -in-Charge .
M&L for earthing of machinery/ equipment/ panel /installed at power house/subatation, complete with galvanised steel earth palte electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.5 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth protected by 40 mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No.3 of SSR Part-I )2009) and testing on complete all as specified and directed by Engineer -in-Charge .
Supply and Fix 100 W High efficient LED Flood light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV for fixing the light fittings on Wall fixed complete all as specified and directed by Engineer -in-Charge .
S&F wall mounted fan 400 MM , 3 blade white colour, 230 Volts, 50 Hz 1420 RPM with 90 degree oscillation and having speed control by 2 pull cord system complete all as specified and directed by Engineer -in-Charge .
S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection complete all as specified of capacity 25 ltr having heating element 2.0 KW and not less than 3 star rating complete all as specified and directed by Engineer -in-Charge . .
S & F in repairs 2mm thick Fibre glass reinforced translucent plain sheeting with 75mm side lap fixed with galvanised tapping screws and washer in any position complete all as specified and directed by Engineer-in-Charge.
M&L for 12mm thick Seamless calcium silicate ceiling made out of 1800x1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25mm long self drilling and tapping screws having Philips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated joining compound and 48mm wide fiber tape to provide seam less finish including provision of sunk or raised moulding with POP as per site reguirement GI frame work for seamless ceiling compraising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 mm length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out G.I. flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40mm long complete all as specified and directed by Engineer-in-Charge.
Note :- Total amount of Sch of credit is Rs. 21727.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/S Sunil Steel Works
LAXMI GROUP
L G BUILDERS
JIWAN DASS THAREJA AND SONS
AMIT ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .