Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹24.5 L+₹3.2 L (15.1%)Rejected-Finance | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹25.5 L+₹4.2 L (19.8%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹33.0 L+₹11.7 L (54.9%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 5 | L5₹33.3 L+₹12.0 L (56.5%)Rejected-Finance | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
28 Sept 2021, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli BANGALORE 560013
SPECIAL REPAIR TO INTERNAL WIRING AND FITTING WITH FIXTURES FOR BLDG No P 536 AT E ITI UNDER AGE EM EAST OF GE M AF JALAHALLI BANGALORE
2021_MES_468965_2
8577/E8
Open Tender
Electrical and Maintenance Works
Item Rate
182 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹60,000
28 Oct 2021
13 Sept 2021
30 Sept 2021
14 Sept 2021
28 Sept 2021
23 Sept 2021
14 Sept 2021 - 20 Sept 2021
Amount
SCH 'A' Part I Internal Electrification Taking down carefully copper/aluminum point wiring (light, fan,Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc removing to store for keeping in safe custody or for taking credit and making good disturbed surface of wall, floors , roof etc all as specified.
Material and labour for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm on surface including provn of metal flush box duly sunkened with modular white cover plate with frame of suitable size for mounting modular switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all as specified and directed for One light point controlled by one switch one way 6 Amps all as specified and directed. (Note : Cost of for cutting chasing, sunken in the wall for box and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate.)
All as per item No 2 but for One ceiling fan point controlled by one switch one way 5 Amps
All as per item No 2 but for One exhaust fan point controlled by one switch one way 5 Amps
All as per item No 2 but for One socket out let 5 Amps 3 pin on same board
All as per item No 2 but for One socket out let 5 Amps 3 pin on independent board
All as per item No 2 here in before but with cable size 4 Sq mm for one 3/5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed.
Supply and fixing Modular switch single pole one way 6 Amps 1 module complete all as specified and directed.
Supply and fixing Mouular socket 6 Amps, 2/3 , combined , 2 module complete all as specified and directed.
Supply and fixing Modular socket 16 Amps, 2/3 combined, 2 module complete all as specified and directed.
Supply and fixing Modular switch single pole one way 16Amps 1 module complete all as specified and directed.
Supply and fixing ceiling fan Modular type regulator electronic step up type 120 Watt 2 module complete all as specified and directed.
Supply and fixing ceiling rose surface Bakelite 3 terminals 65x50mm complete all as specified and directed.
Remove and refix existing serviceable ceiling fans 1200/1400 mm sweep servicing, painting and writing MES No. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, filling cavities with filler after cleaning all dust etc. complete all as specified and as directed by Engineer-in-Charge.
Remove and refix existing serviceable Wall mounted fans of any size and sweep servicing painting and writing MES No. of W/M/fan including greasing/oiling, after cleaning all dust etc. complete all as specified and as directed by Engineer-in-Charge.
Remove and refix existing serviceable Exhaust fans of any size and sweep, servicing painting and writing MES No. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, filling cavities with filler after cleaning all dust etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling fan 1200 mm sweep, 50 Watts, 340 RPM, 230/240 volt AC, Kessels star Product Code 251085 Make : Bajaj, single phase including provision of suitable C/F hooks for fixing ceiling fan and three core copper PVC flexible cable of size 0.5 sq mm including writing CA No and MES No 2 cm height with two coats of synthetic enamel paint all as specified and directed. Make : BAJAJ ,Crompton, Havells, orient,GEC, Almonard or equivalent approved make
Supply and Fix Esteem Wall Mounted Fan, 400 mm sweep, 1320 RPM, 230/240 volt AC, Product code 250552 Make : BAJAJ or equivalent complete including connecting and testing as specified and directed. Make : BAJAJ ,Crompton, Havells, orient,GEC, Almonard or equivalent approved make
Supply and fixing Exhaust fan 300 mm sweep, 230/240 volt AC single phase 410W, 1400 RPM, including core cutting hole on stone masonry (Machine cutting) suitable for fixing exhaust fan with suitable nuts bolts and louvers and make good the surface to match with existing surface complete. Make Bajaj, MAXX AIR code 70046 Crompton, Havells, orient,GEC, Almonard or equivalent approved make.
Supply and fix LED surface mounted full lit with glare free uniform illumination with longer light and le maintenance 2' x 2' 36 watts LED luminaries with polymer diffuser complete with accessories. Make : Crompton, Polaries NIO-III, Product description LCTLSNE-36-F0-CDL, 36 Watts or equivalent make Bajaj/WIPRO/CG, Haveels Including taking down old light fitting.
Taking down and Refixing existing serviceable LED surface/recessed 2' x 2' LED luminaries of any make, type and capacity complete all as directed.
Taking down and Refixing existing serviceable LED surface/recessed 9'' x 9'' 36 watts LED luminaries of any make, type and capacity complete all as directed.
Supply and fix LED Batten, Delux 36Watts 4 ft Robust extruded aluminum housing, elegant dual coloured end caps designed to deliver glare free light complete with accessories. Make BAJAJ. Product code 830337, 36 Watts CDL, IVORA or equivalent make WIPRO/CG Including taking down old light fitting.
Supply and fix LED Batten, plastic 10 Watts 2 ft housing made of engineering plastic, designed to deliver glare free light complete with accessories. Make BAJAJ. Product code 830206, 10 Watts CDL plastic or equivalent make WIPRO/CG/ Haveels Including taking down old light fitting.
Supply and fix Round Surface mounted LED fitting/panel, PDC Aluminium housing, translucent frosted plastic diffuser makes it a robust luminaries complete with accessories. Make Crompton, PEARL NIOS-R product description LCDSPLN-R-18-CDL or equivalent make Bajaj/WIPRO/ Haveels Including taking down old light fitting.
Supply and fixingixing Spot light fitting specially designed for commercial usage long life with 30000 burning hours with CRI less than 80, 12 Watts product description CDR-212-12-30-SL-NWH Make Crompton, FAME SPOT or equivalent make Bajaj/WIPRO/CG Including taking down old light fitting
Supply and fixing LED building security/street light fitting 60 watts made up of pressure diecast housing with toughened glass diffuser, with high power LEDs with option of secondary optic with IP66 protection, 110 LM/ watt and wired with accessories including suitable bracket & clamps with bolts & nuts. Make Crompton, NEXUS NEO Product Description LSTP-60-CDL-M or equivalent make Bajaj/WIPRO/CG/ Havells Including taking down old light fitting
Removing existing old unserviceable dummy DC Change over switches of any size and capacity including making good the disturbed surfaces to match with the existing surface as directed by the engineer-in-charge
Material and labour for sub main wiring with 2 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sqmm drawn through suitable size of non-metallic PVC rigid conduit with 4 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up and taking down old wiring complete all as specified Including taking down old sub main wiring.
Material and labour for sub main wiring with 2 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 10 sqmm drawn through suitable size of non-metallic PVC rigid conduit with 1x6 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up and taking down old wiring complete all as specified Including taking down old sub main wiring.
Material and labour for sub main wiring with 4 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 10 sqmm drawn through suitable size of non-metallic PVC rigid conduit with 1x10 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, connecting up and taking down old wiring complete all as specified Including taking down old sub main wiring.
Supply and fixing VTPN 12 way MCCB distribution box, Double door IP : 43 protection, door earthing, Isolated neutral bar, Mechanical Impact Strength IK 08, Insulated bus bar assembly suitable for MCCBs up to 63 Amps, 16kA 4 Pole connecting up complete Make: INDOASIAN HSN Code 8537, Cat Ref 811891, L&T, ABB, Siemens, schneider, Haveels, Legrand,or equivalent approved make all as specified and directed Including taking down old MCB DB's
Supply and fixing VTPN 8 way MCCB distribution box, Double door IP : 43 protection, door earthing, Isolated neutral bar, Mechanical Impact Strength IK 08, Insulated bus bar assembly suitable for MCCBs up to 63 Amps, 16 kA, 4 Pole Make: INDOASIAN HSN Code 8537 Cat Ref 811890 Optipro or equivalent approved make, connecting up complete all as specified and directed Including taking down old MCB DB's
Supply and fixing VTPN 6 way MCCB distribution box, Double door IP : 43 protection, door earthing, Isolated neutral bar, Mechanical Impact Strength IK 08, Insulated bus bar assembly suitable for MCCBs up to 63 Amps TPN, Make: INDOASIAN HSN Code 8537 Cat Ref 811889 Optipro or equivalent approved make, connecting up complete all as specified and directed Including taking down old MCB DB's
Supply and fixing VTPN 4 way MCCB distribution box, Double door IP : 43 protection, door earthing, Isolated neutral bar, Mechanical Impact Strength IK 08, Insulated bus bar assembly suitable for MCCBs up to 63 Amps TPN, Make: Make: INDOASIAN HSN Code 8537, Cat Ref 811888, L&T, ABB, Siemens, schneider, Haveels, Legrand,or equivalent approved make connecting up complete all as specified and directed Including taking down old MCB DB's
Supply and fixing in repair, sheet metal enclosure distribution box suitable for MCB'S 12 way SPN with 200 Amps rated bus bar , 240 volts double door complete including connecting up all as specified and making good disturbed surface
Supply and fixing in replacement of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, completete all as directed and specified, including taking down old unserviceable plug socket Including taking down old MCB DB's.Male :- Make: INDOASIAN HSN Code 8537, Cat Ref 811956, L&T, ABB, Siemens, schneider, Haveels, Legrand,or equivalent approved make
Supply and fixing MCCB 16kA 63 Amps 4 pole optium 1.0E (Fixed TM Range) suitable for isolation, fixed Overload & fixed short circuit setting F1. Make: INDOASIAN HSN Code 8537, Cat Ref 836020, L&T, ABB, Siemens, schneider, Haveels, Legrand,or equivalent approved make
Supply and fix MCB TP 63 Amps, 415 volt 10 KA C Curve, Including taking down old MCB's Make: INDOASIAN HSN Code 8537, Cat Ref 811198, L&T, ABB, Siemens, schneider, Haveels, Legrand,or equivalent approved make
Supply and fix MCB SP 63 Amps, 415 volt 10 KA C Curve, Including taking down old MCB's Make: INDOASIAN HSN Code 8537, Cat Ref 811132, L&T, ABB, Siemens, schneider, Haveels, Legrand,or equivalent approved make
Supply and fixing MCB Single pole 240 volts 5 to 32 Amps, 10KA rupturing capacity, C series complete all as specified and directed Including taking down old MCB's Make: INDOASIAN HSN Code 8537, Cat Ref 811129, L&T, ABB, Siemens, schneider, Haveels, Legrand,or equivalent approved make
Supply and fixing Aluminium strip 25 X 3.15 mm with porcealin saddles and fixing screws etc in every one metre interval for roof conductors and down conductors and above ground complete all as specified and directed.
Supply and fixing Air termination single pointed aluminium rod 12mm dia and 300 mm long with mounting pad complete all as specified and directed.
Material and labour Test terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. Head screw complete all as directed.
Supply and fixing Copper strip 25 X 3.15 mm with saddles and fixing screws etc in every one metre interval for roof conductors and down conductors and above ground complete all as specified and directed.
Material and labour for Rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couples, lock nuts, saddles, pipe hooks etc. of size 40 mm dia running on wall/floor including taking down old U/S conduit pipe
Material and labour for earthing complete with copper earth plate electrode 60x60cmx3.15mm buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top dege of the plate not less than 1.5 meters below normal ground level, connected to 20X3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 3 connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe but all as specified and directed by Engineer-in-Charge. all as specified or indicated including testing on completion and taking down old earthing material.
Material and labour for earthing complete for lightning conductor with Galvanised iron earth plate electrode 60x60cmx3.15mm buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top dege of the plate not less than 1.5 meters below normal ground level, connected to 20X3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in elctrical plate No 3 connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe but all as specified and directed by Engineer-in-Charge. all as specified or indicated including testing on completion and taking down old earthing material.
SCH 'A' Part II External Electrification Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3½ core UG cable (Including earth work and taking down old U/S UG cable
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core UG cable runinng on wall / floor/dcukt) including taking down old U/S UG cable
Material and labour for Rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessaries such as couples, lock nuts, sadles, pipe hooks etc. of size 40 mm dia running on wall/floor for running the 50 sqmm cable on wall including taking down old U/S conduit pipe
Excavation in trenches hard and dence soil not Exe. 1.5m wide and not Exe. 1.5m in depth for laying cable and getting out in hard/ dense soil.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soil all as specified.
Supply and spread dry river sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming all as specified and directed Note:- For the purpose of payment the punned thickness only measured.
Supply and lay un-reinforced precast concrete cable cover, class LV, Type-I flat, size 250mm x 150mm x 40 mm for cable protection all as specified and directed.
Removing the excavated soil to a distance not exe 50m and depositing where directed at a level n exe 1.5m above the starting point all as directed.
Material and labour for plain cement concrete type D2 1:4:8 in 40 mm graded stone aggregate for making good disturbed surface etc. all as specified.
Supply and fixing GI tubing light grade 50 mm dia for cable protection fixed along with steel tubular pole / RCC pole/ laying in ground including necessary clamp, nut, bolt, washers etc. all as directed at site.
Material and labour for earthing for DG Set and panel board complete with copper earth plate electrode 60x60cmx3.15mm buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top dege of the plate not less than 1.5 meters below normal ground level, connected to 20X3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in elctrical plate No 3 connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe but all as specified and directed by Engineer-in-Charge. all as specified or indicated including testing on completion and taking down old earthing material.
SRI LAKSHMI CONSTRUCTIONS
M/S SRI BALAJI ENTERPRISES
RRK PROJECTS
KUZHIKKAL ENTERPRISES
H S S ENGINEERS AND CONTRACTORS
devan enterprises
Vasavi Electricals
Maruthi constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .