Chief Engineer (R and D) Delhi
HQ CE R and D Delhi, Probyn Road, Timarpur Delhi - 110054
DEMOLITION OF UNSAFE BUILDINGS (P-57, P-58, P-59, P-60, P-62, P-63, P-64 AND P-65) AND PROVISION OF NEW CONSTRUCTION OF TYPE-IV (14 NOS), TYPE-III (29 NOS) AND TYPE-II (26 NOS) QTRS IN LIEU OF TYPE-III (20 NOS) AND TYPE-II (20 NOS) AT ADRDE AGRA
2026_MES_756251_1
CE RnD/DLI-40/AGR/2025-26
Open Tender
Civil Works
700 days
Delhi
As per tender documents
9 documents required · 9 mandatory
₹3,000
GE (I) RnD Delhi
₹15 L
Yes
Delhi
13 Mar 2026
13 Mar 2026
26 Jun 2026
27 Mar 2026
19 Jun 2026
12 Jun 2026
27 Mar 2026
SCHEDULE 'A' SECTION-I (BUILDING WORKS) as under is not prepriced by MES and Estimated cost indicates 0.00 under Col-5 signifies this fact only.
Design and Build Type-IV Married Accomodation with RCC frame structure upto (Stilt+5) storeys complete all as specified and as shown on Architectural drawings.
Design and Build Type-III Married Accomodation with RCC frame structure upto (Stilt+5) storeys complete all as specified and as shown on Architectural drawings.
Design and Build Type-II Married Accomodation with RCC frame structure upto (Stilt+5) storeys complete all as specified and as shown on Architectural drawings.
Design and Build RCC UG Sump 3.00 Metre Dia for storage of ltr capacity 21208.50 complete all specified and directed as per DBR and approved drawings.
Design and Build RCC UG Sump 4.5 Metre Dia for fire fighting of ltr capacity 50000.00 complete all specified and directed as per DBR and approved drawings.
Design and Build 100% FRP based modular and package type sewage treatment plant, Capacity-100000 Ltr specially designed for underground applications with tertiary treatment complete all specified and directed as per DBR and approved drawings.
Design and Build 100% FRP based modular and package type sewage treatment plant,Capacity-45000 Ltr specially designed for underground applications with tertiary treatment Note for item 6.00 & 7.00:- i) STP shall be designed and constructed as per DBR and approved drawings. ii) Manning and operation of STP plant 100 KLD capacity consisting of two shifts including Sundays and holidays & Manning and operation of STP plant 45 KLD capacity consisting of two shifts including Sundays and holidays for two year from date of completetion including minor repair of all connected electrical & Sewage Pumps items such as main switch, starter, change over switch, MCCB, voltmeter, ammeter, panel board, etc., Sewage water pump, valve system, controlling system, daily checking, leakage, checking noise, cleaning of plant and its sorrounding area etc, by one FGM (skilled) per shift for 02 shifts in a day all as specified and directed by Engr-in-charge. Shift Details TRADEMAN: 01 FGM x 02 shift per day =02 FGM per day (iii) Comprehensive maintenance of plant including replacement of any defective/wornout parts are covered under defect liability period of two years.
Schedule 'A' Section-II to Section-XVI as under Serial No. 2.01 to 2.15 are prepriced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Section-II.
Lump sum price worked out by the Contractor for “DEMOLITION” as listed in Schedule ‘A’ Section-III.
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Section-IV.
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section-V.
Lump sum price worked out by the Contractor for “ROAD/PATH/CULVERT” as listed in Schedule ‘A’ Section-VI.
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Section-VII.
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Section-VIII.
Lump sum price worked out by the Contractor for “RAIN WATER HARVESTING” as listed in Schedule ‘A’ Section-IX.
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Section-X.
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section-XI.
Lump sum price worked out by the Contractor for “FIRE FIGHTING” as listed in Schedule ‘A’ Section-XII.
Lump sum price worked out by the Contractor for “SOLAR WATER HEATING SYSTEM” as listed in Schedule ‘A’ Section-XIII.
Lump sum price worked out by the Contractor for “GEYSER” as listed in Schedule ‘A’ Section-XIV.
Lump sum price worked out by the Contractor for “LIFT” as listed in Schedule ‘A’ Section-XV.
Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION” as listed in Schedule ‘A’ Section-XVI.
SCHEDULE `A' SECTION - XVII (MISC ITEMS) as here-in-after not prepriced by MES (To be quoted by the tenderer against each item)
DEMOLITION
Taking down DB SPN of any type by disconnecting all electrical connection including MCB of any size all as specified and directed.
Taking down DB TPN of any type by disconnecting all electrical connection including MCB of any size all as specified and directed.
Dismantling and taking down Old aluminium/copper Sub main wiring of 4/6/10 sqmm 2/3 run incl conduit complete all as specified and directed by Engr in Charge
Taking down single phase Energy meter of any type carefully by disconnecting all connection and deposit to AGE E/M store all as specified and directed
Disconnecting and taking down old earthing
Dismantling Outdoor LT panel of any type and size by disconnecting all cable connections and fittings taken on credit incl removal of items out of MOD land complete all as specified and as directed by Engr in Charge.
All as per Item No 4.09 above but for 50/70/95 Sqmm UG LT Cable complete all as specified and as directed
Demolition/Dismantling of Valve pit chamber of any size incl sluice valve upto 100 mm Dia by disconnecting all pipe fittings like bend ,Tee, valve etc and taken on credit incl removal of unserviceable items out of MOD land complete all as specified and directed by Engr in Charge. Note: The rate quoted shall be inclusive of providing & fixing end cap or other fittings to existing pipe line for uninterrupted water supply to existing building.
INTERNAL ELECTRIFICATION
S & F MCB for conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed.
10A, 230V, 50Hz, 2P MCB (C'curve) complete all specified and directed.
25A, 230V, 50Hz, 2P MCB (C'curve) complete all specified and directed.
32A, 230V, 50Hz, 2P MCB (C'curve) complete all specified and directed.
10A, 230V, 50Hz, 4P MCB (C'curve) complete all specified and directed.
Supply and fixing decorative , wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with 10 W LED lamp B22 base ,220 V AC complete , complete with 10 W LED lamp B22 with lumen output 945 lumen, operating range 140-260V,lamp tested for estimated life span of 25,000 hrs,suitable fixing arrangement and connecting complete all as specified and directed Note:Location for Installation of LED fitting shall be as per user requirement.
Supply and fixing 12 W LED light fitting, round surface down type with high out put diffuser 140mm dia, 12 watt 220 V AC decorative type with driver holder and LED lamp including connec`ting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by the engineer-in-charge.
S & F RJ 11 Telephone socket modular type with transparent shutter 1 module with modular plate, flush box & frame complete all as specified and directed.
S & F TV socket modular type 1 module with modular plate, flush box & frame complete all as specified and directed.
Supply and fixing COVE LED strip with adhesive backing 25 W warm white including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by the engineer-in-charge.
Supply and Installation of Smart Single Phase Cellular Meter with the following specifications: • AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt cellular communication (4G fallback to 2G) B12with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support the following data : 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, daily and monthly billing survey for Cumulative Energy and Max Demand • Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per IS 15959 part 2 • The meter should support open communication protocol DLMS with the software Note: (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It would be possible to run the meter in both prepaid and postpaid mode (c) The meters would carry 5 year warranty.
Supply and Configuration of the Web based Software with following modules: (i) Meter Data Management Module The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data: (a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency (b) Monthly billing survey data for cum energy and max demand (ii) Postpaid /Prepaid Billing Module The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required. (iii) Occupation and Vacation Module The system would support occupation / vacation and billing reports. the software would be collecting data from DCU. The software would provide access to staff as well as the occupant for the data. (iv) Web site: There would be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to the application. The MES staff would also have the access of the key information on an android mobiles app (for admin use). (v) Customer Portal The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis." (vi) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (vii) Communication Module The system would provide communication of energy data and bills via print, email and sms methods.
(viii) Meter Master Data The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export The system would support export of metering and billing data in excel format. (x) Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. (xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email. Make: Schneider, Innologix, SAP Note: (a) The software would be hosted either on GCC Server or on MES Server. In case the software is hosted on GCC Server, it would be transferred to MES server whenever the MES is made available. (b) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc. (c) GE Bank account and one payment gateway would be provided by MES. The payment gateway would be integrated with the software in that situation.. (D) The software would be scalable and expandable for meters and system of different make complying with IS16444. It would be possible to integrate provided information is available for the meter integration protocols, meter passwords etc.
Supply of desktop computer as vending station with configuration of i5 10th generation or above, 8 GB ram, 1 TB hard disk, 19” flat monitor as minimum, Windows 10/11, MS Office, wireless keyboard and mouse, CD Rom read /write, USB port etc. including suitable UPS complete all specified and directed.
Supply & Installation of black & white laser printer with print, scan & copy function having USB connection with printing speed of min 40 pages per mintue for printing Reports etc. complete all specified and directed.
Two years Comprehensive maintenance of Item No 5.11 & 5.12 as mentioned above during two years of defect liability period icluding sim charges complete all specified and directed.
Two Years GCC Hosting Charges for the software during the defect Liability period complete all specified and directed.
Eight year comprehensive maintenance including operating costs after two years of defect liability period for RF System. They would include the following items: (a) Monthly sim charges for the DCU. The contractor would ensure supply of appropriate SIMs to ensure necessary single availability. The contractor would change the sim or sim provider as required. In case of network issues, the contractor would liaison with the telecom service providers for necessary resolution. (b) Recurring SMS charges. The SMS would be issued for the payments alerts, low balance alerts and disconnection / connection alerts. (c) Software AMC. This would include necessary upgradations in the software such as support to the chrome browser changes, android version changes , iOS version changes. These changes happen on frequent basis and the software would support all the changes. (d) Changes in the government tariff structure. The government tariff structure changes may require software upgrade. The same would be included in the AMC scope of work. (e) Remote server admin support - Ensuring adequate database back up, upgradations in the operating system, anti virus updates, database upgrade etc. (f) Reports Development - The additional reports as needed for the success of the project would be developed (g) Software installation on any alternate / backup server if required (h) The communication network monitoring and support (i) Configuration of the repaired / replaced hardware in the system (j) Trouble shooting and necessary actions to run the system as required. (k) Software bug fixing as and when required
GCC Hosting charges for the software for 8 years complete all specified and directed.
INTERNAL WATER SUPPLY
S&F 15 mm fancy type two way Bib taps with wall flange,chromium plated cast copper alloy with crutch or butterfly handle,screwed down,screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed
M&L for fixing 15mm nominal bore fancy type CP Brass Single lever telephonic Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges completed all as specified and directed.
M&L for fixing 15mm nominal Central Hole Basin Mixer with Popup Waste system with 450mm Long Braided Hoses (15mm Cartridge Size) complete all as specified and directed
M&L for fixing Standard Size Sink Cock with Regular Swinging Spout (Wall Mounted Model) With Wall Flange completed all as specified and directed.
M&L for fixing Overhead Shower 140mm Round Shape Multi Flow (Rain & Massage) with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System completed all as specified and directed.
ROAD/PATH/CULVERT
S&F road studs made of polycarbonate moulded plastic body of single shank of size 100x100x26mm of min weight of 140gms with electronically welded micro prismatic lense on both side of colour- Yellow/Red/Amber for maximum retro reflection in wet and dry conditions and to be fixed on road with shank as road sign complete all as per manufacturer instructions and specified as directed
S&F ABS plastic speed bump/speed breakers in parabolic convex shape and of size 750 mm x 250 mm x 70 mm made out of steady plastic, dovetail interlocking sub units, jointed and fixed to make the bump perfectly uniform, bump made out of precolourd material (black/yellow) and UV stablizers to keep them perfectly colourful, studded with reflectors on either side to make it clearly visible to motorists during night hours complete all as specified and directed.
Providing and laying Cement concrete prepared with batch mixing machine design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominalsize in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as specified and directed (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).
Providing and filling grade 'A' sealing compound conforming to IS: 1834 in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.
M&L for Cutting Bituminous Portion of road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required complete all as specifird and directed.
M&L for providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete all as specified and directed
M&L for Cutting water bound macadam and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required complete all as specifird and directed.
M&L for providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete all as specified and directed
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed (length of finished kerb edging shall be measured for payment).
SEWAGE DISPOSAL
M&L for HDPE DWCPE (SN8) 180 (OD)/163(ID) mm diameterpipes including testing of joints as per IS: 16098 etc. complete all specified and directed.
M&L for HDPE DWCPE (SN8) 200 (OD) mm diameterpipes including testing of joints as per IS: 16098 etc. complete all specified and directed.
M&L for providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. complete all specified and directed.
AREA DRAINAGE
M&L for placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charg complete all as specifed and directed.
RAIN WATER HARVESTING
Supply only Stone grit 6 mm and down size or pea sized gravel complete all as specified and directed.
Supply only Stone Aggregate (Single size) : 20 mm nominal size complete all as specified and directed.
Supply only Stone Aggregate (Single size) : 40 mm nominal size complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply installation testing and commissioning of street light panel single phase suitable for max load of 6 KW with astronomical switch enclosure conforming to IP 54,40Amp SPN MCB suitable and including mounting on wall/pole for control street light/aviation light including connections with the cable gland aluminium lug, MS FIixing clamp ,cutting the hole in wall of suitable size including taking out the old main switch/MCB/MCCB complete all as specified and directed.
LT cubical outdoor type feeder piller Panel double door CPRI approved made out of CRCA sheet 3.15 mm thick totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about load termination, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar 600 A for phases and 400 A for neutral with insulators suitable for three phase and capacity complete & powder coating, necessary internal electric connection as required, plastic coated insulated screen in four colour red, yellow, blue & black including frame of panel with angle pf size 50 x50x6mm and provision of the following.(Loc- Main LT Panel at Type II & III Qtr) MCCB 4 Pole, 400 Amp , 415 Volts, 50 Hz, breaking capacity 35 KA (I/C) - 01 Nos MCCB 4 Pole, 200 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA - 04 Nos (01 x spare) Multifunction Meter with LCD Display Class 1.0 LED Indicator R,Y,B
LT cubical outdoor type feeder piller Panel double door CPRI approved made out of CRCA sheet 3.15 mm thick totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about load termination, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar 200 A for phases and 200 A for neutral with insulators suitable for three phase and capacity complete & powder coating, necessary internal electric connection as required, plastic coated insulated screen in four colour red, yellow, blue & black including frame of panel with angle pf size 50 x50x6mm and provision of the following.(Loc- Feeder piller LT Panel at Type II Qtrs & Type III Qtrs) MCCB 4 Pole, 200 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA (I/C)- 01 Nos MCCB 4 Pole, 100 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA - 04 Nos (01 x Spare) Multifunction Meter with LCD Display Class 1.0 LED Indicator R,Y,B
LT cubical outdoor type feeder piller Panel double door CPRI approved made out of CRCA sheet 3.15 mm thick totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about load termination, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar 200A for phases and 200 A for neutral with insulators suitable for three phase and capacity complete & powder coating, necessary internal electric connection as required, plastic coated insulated screen in four colour red, yellow, blue & black including frame of panel with angle pf size 50 x50x6mm and provision of the following.(Loc- DG Supply LT Panel at Type-II & Type III Qtrs) MCCB 4 Pole, 200 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA (I/C)- 01 Nos MCCB 4 Pole, 100 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA - 03 Nos (01 x Spare) MCCB 4 Pole, 32 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA -03 Nos MCB SPN,16 Amp , 220 Volts, breaking capacity 10 KA -02 Nos DOL starter suitable upto 10 HP motors-02 Nos (for open well submersible pump) Multifunction Meter with LCD Display Class 1.0 LED Indicator R,Y,B
LT cubical outdoor type feeder piller Panel double door CPRI approved made out of CRCA sheet 3.15 mm thick totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about load termination, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar 100 A for phases and 100 A for neutral with insulators suitable for three phase and capacity complete & powder coating, necessary internal electric connection as required, plastic coated insulated screen in four colour red, yellow, blue & black including frame of panel with angle pf size 50 x50x6mm and provision of the following.(Loc- DG Sub Panel at Type II & III Qtrs - 02 Nos, at Type IV Qtr - 01 Nos) MCCB 4 Pole, 100 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA (I/C)- 01 Nos MCCB 4 Pole, 63 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA -01 Nos MCCB 4 Pole, 25 Amp , 415 Volts, 50 Hz -3 Nos Multifunction Meter with LCD Display Class 1.0 LED Indicator R,Y,B
LT cubical outdoor type feeder piller Panel double door CPRI approved made out of CRCA sheet 3.15 mm thick totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about load termination, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar 250 A for phases and 250 A for neutral with insulators suitable for three phase and capacity complete & powder coating, necessary internal electric connection as required, plastic coated insulated screen in four colour red, yellow, blue & black including frame of panel with angle pf size 50 x50x6mm and provision of the following.(Loc- Main LT Panel at Type -IV Qtrs) MCCB 4 Pole, 160 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA (I/C)- 01 Nos MCCB 4 Pole, 125 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA - 03 No (01x Spare) Multifunction Meter with LCD Display Class 1.0 LED Indicator R,Y,B
Supply & Fix MCCB 100 Amps, 415 V, 50 Hz, breaking capacity 25 KA suitable to fix V-TPN DB complete all as specified and directed.
Supply & Fix MCCB 63 Amps, 415 V, 50 Hz, breaking capacity 25 KA suitable to fix V-TPN DB complete all as specified and directed.
Re routing/shifting of existing PVC/XLPE Insulated HT UG cable, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11 KVolts grade with stranded aluminium conductor of size from 95 Sqmm 3 Core laid in trench by removing/taking up the existing cable, disconnecting all connection and laying of the same cable in new position laid in trenches including all connections etc. required as per site condition complete all as specified and directed by Engr in Charge.
Re routing/shifting of existing PVC/XLPE Insulated LT UG cable, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size upto 150 Sqmm 3.5/4 Core laid in trench by removing/taking up the existing cable, disconnecting all connection and laying of the same cable in new position laid in trenches including all connections etc. required as per site condition complete all as specified and directed by Engr in Charge.
M& L for fixing junction box made of plastic material of size 240X330X130 mm with opaque cover ,conical cable gland aluminium lugs, Protection Class IP 65,04 nos aluminium bus bar of size 25x3 mm for three phase and neutral including 01 nos 06 Amps MCB SP for controlling street light and 2 Nos MS clamp of size 30x5 mm complete with nut, bolt and washers for mounting the junction box on street light pole complete all as specified and directed
Supply & fixing PVC insulated aluminium conductor 2.5 Sqmm 3 Core cable (incl 1x2.5 sqmm earth wire )for service connection of street light from junction box to street light fittings complete all as specified and directed.
Supply and fixing V- TPN,12 way (4+36) double door loadline MCCB incomer,Double door 415 volt distribution board on recess complete with 200 Amp copper bus bar,netural bus bar,earth bus bar,din bar,blanking plates,interconnections earthing etc, as required(Loc- Stilt Parking at Type II &Type III Qtrs,ADRDE colony)
EXTERNAL WATER SUPPLY
Supply installation testing and commissioing of openwell submersible pumping sets electric operated multistage having minimum discharge capacity of 420 LPM at 48 M 2900 RPM, 3 phase, 415 volt, head with steel shaft , CI impeller, CI casing totally enclosed with suitable capacity squirrel cage induciton motor 7.5HP for suitable operation on 3 phase , 50 Hz, 415 V, including making PCC foundation of suitable size. The pump set will be fixed on common base channel frame supported by anti viberation pad and also to be fixed by nylon rope in sump to easily taking out the pump set in case of failure including necessay electric connection with multi stranded copper conductor cable of suitable size from starter to motor and making inlet/outlet pipe line connection using nuts, bolts, rubbers gaskets etc and other required materials for smooth funciton of pump sets complete all as specified and as directed.
Supply and fix " Aquafit" Chlorine dosing system,including Preparation tank Model No-AQUA1005 of net capacity 170 Ltr,FRP dosing tank dia 650 x height 375 +conical 300 mm, gross height with stand 1000 mm consisting of water inlet line, out let with "Y" strainer, drain, over flow, conical bottom foe sluydge deposition, pot hole with cover, levelgauge Agitator 120 watt 900 RPM, single phaseflenged mounted motor with plastic shaft, and impeller and Service tank Model No-AQUA1006 of net capacity100 Ltr of FRP dosing tank top dia 540 mm x bottom dia 480 mm x height 575 mmconsisting of water inlet line, dosing pump inlet arrangement, drain, over flow, level gauge, inspection port, Agitator 120 watt 900 RPM, single phaseflenged mounted motor with plastic shaft, and impeller, provision of mounting lid complete.
Re routing of 80mm DI/CI/steel tubing of water supply Pipe line laid in trench by removing/taking up the existing pipe, disconnecting all fittings deposited to MES store and laying of new GI steel tubing of 80mm dia bore in new position laid in trenches including all new fittings ,complete earth work etc. required as per site condition complete ,including connection with exsisting pipe line with required size of Tee /elbow/bends etc all as specified and directed.
Re routing of 40/50 mm steel tubing of water supply Pipe line laid in trench by removing/taking up the existing pipe, disconnecting all fittings deposited to MES store and laying of new GI steel tubing of 50 mm dia bore in new position laid in trenches including all new fittings ,complete earth work etc. required as per site condition complete ,including connection with exsisting pipe line with required size of Tee /elbow/bends etc all as specified and directed.
M&L for Cutting road / hard standing to a size not exceeding 50 cm in width and not exceeding 100 cm in depth for laying of DI pipe of 100mm bore including making good so as to match with the existing finishes using PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) of 100 mm thick complete all as specified and directed.
Supply and laying,commisioning and testing of 100mm pipe Centrifugally Cast ductile Iron pressure pipe with spigot & Socket end,Class K-9 conforming to IS8329/2000 suitable for rubber gasket jointing with centrifugal applied inside cement mortor lining with sulphur resistant cement and external metallic zinc coating with finishing layer of black bitumen coating on external surface, rubber gastket including Specials i.e Tee,Unioin,flange Sockets & spigot, Bends any specials required to connect the Pipe all as specified and directed. Note: The above shall be inclusive of all Specials ,fiitings ,demolition of plain cement concrete as per site requirement and making good , Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots etc.,Laying of Pipes under the existing road/culvert etc.
Supply and laying,commisioning and testing of 100mm pipe ductile Iron pressure pipe with douple flanged (screwed/welded) Centrifugally (Spun),Class K-9 conforming to IS8329 incl suitable jointing(rubber/fiber board gasket etc,) external metallic zinc coating with finishing layer of black bitumen coating on external surface all as specified and directed. Note:-The above shall be inclusive of all Specials ,fiitings ,demolition of plain cement concrete as per site requirement and making good , Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots etc.,Laying of Pipes under the existing road/culvert etc.
M&L for Construction of brick masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 complete all as specified and directed.
M&L for Construction of brick masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 incl dismanteling old one complete all as specified and directed.
M&L for Construction of masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
FIRE FIGHTING
S & F of 4.5 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. NOTES: [i] Test Pressure: 250 kgf / Sq. cm [ii] Operating temperature : -300C to + 550C [iii] Locking pin and wire seal should be provided to indicate that the extinguisher has not been use. [iv] Every Extinguisher should be supplied with an operating manual.
S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature : -300C to + 550C "[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters" [iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar
S & F of 9 litre water stored pressure type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge.
S & F of Signage having size 300 mm X 150 mm reading "EXIT" in 12.5 mm block letters in Green and white background, self illuminated properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level.These lights shall emit the maximum light required even during the electricity supply or in Black out period with high energy efficiency manufactured using superior quality Aluminium Extrusion body raw material EXIT Signage shall meet the following technical / operational requirements: [i] Product Material: Alluminium ALLOY Extrusion [ii] Product Finish:- Matt Black / Snow white finish after phosphochromate treatment [iii] Wattage:- 5 Watt [iv] Mounting: Surface / Hanging
S & F of Signage having size of 500 mm X 500 mm, indicating the "Floor Number" in bold type and at 75 mm high numerals in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, posted and maintained within each stair enclosure on every floor, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level.
S & F of Signage having size of 450 MM X 150 MM reading "FIRE EXTINGUISHER" in 12.5 mm block letters in White and Red background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level.
S & F of Signage having size of 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the "STAIRCASE" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level
Supply and fix MS flanged pipe 100 mm NB heavy duty for multi storied building dully painted with 2 coats of synthetic enamel paint over a coat of zink chromate primer.
Supply and fix MS flanged pipe 80 mm NB heavy duty for multi storied building dully painted with 2 coats of synthetic enamel paint over a coat of zink chromate primer.
S & F gunmetal fire hydrant single Landing valve with 80 mm NB flanged inlet, brass spindle controlled 63 mm NB female instantaneous outlet type gunmetal coupling, blank cap, chain, twist release type lug & all accessories conforming to IS 5290: 1993 including fixing and flanged tapping from stand post type fire hydrant complete all as specified and directed by the engineer-in-charge.
S & F of Orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed by the engineer-in-charge.
S & F non-percolating rubber reinforced lined RRL hose type- A 15 m long fire hose of 63 mm NB size, conforming to IS 636: 1988, rated for bursting pressure of 35.7 kg/cm² complete with gunmetal male & female coupling conforming to IS 903: 1993, bound and rivetted to the hose pipe with copper rivets and 1.5 mm² copper wire complete all as specified and directed by the engineer-in-charge.
Supplying and fixing first aid Hose reel of 30 mtr with MS construction spary painted in post office red, conforming to IS 884 complete with the following as required. a. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:12585. b. 20 mm nominal internal dia gun metal globe valve & nozzle. c. Drum and brackets for fixing the equipments on wall. d. Connections from riser with 25 mm dia stop gun metal valve & M.S pipe and socket
Supply and fix 100 mm bore reflex valve (NRV) with by pass arrangement , 100 mm dia with complete set complete all as specified and as directed
M & L for PN 1.6 rated CI 'Y' -type strainer for suction conforming to IS 907: 1984 with SS filter screen and flange drilling standard end connection conforming to IS 1538: 1993 along with necessary accessories complete all as specified and directed by the engineer-in-charge.
Supplying ,fixing,testing and commissioning of 100 mm dia butterfly valve of PN 1.6 rating with broze/gunmetal seat duly ISI marked complete with nuts,bolts,washers,gaskets confirming to IS 13095 of fillowing sizes as required complete all as specified and as directed
Supply, installation, testing and commissioning of 2- Way Fire Brigade draw- off connection with two 63 mm NB inbuilt gunmetal non-return valves instantaneous coupling type arranged on 100 mm NB pipe manifold and connected to wet riser main as well as to fire water tank including CI butterfly valve, CI non-return valve and MS cabinet with mounting supports, etc. complete all as specified and directed.
Supply, installation, testing and commissioning of bourdon Pressure gauge suitable for 0-21 kg pressure range with 4" dial, die cast aluminium body, ball valve, nipple, socket, etc. for delivery lines of fire pump sets near the flow switches all complete as specified and directed.
Supply, installation, testing and commissioning of FM approved and UL listed surface / semi- flush mounted Dual Action Manual Pull Station "Push In & Pull Down" including an addressable interface for the intelligent FACP having built-in bicolour LED which is visible, flashing in normal operation and latching steady red in alarm condition, captive screw terminals wire-ready for easy connection to SLC loop complete all as specified and directed by engineer-in-charge.
Supply, installation, testing and commissioning of UL listed of Horn Strobe, wired as a primary notification appliance, flashing 75 cd at 1 Hz over the strobe's entire operating voltage range, xenon flash tube and associated lens / reflector system, built-in synchronization feature keeping strobes in sync for up to 30 minutes, horn producing audible annunciation of 75 dBA at 3 m distance complete all as specified and directed by engineer-in-charge.
M & L flame retardant, low smoke & low halogen fire alarm armoured cable 1.5 sqmm 2 core having stranded class 2 copper conductor conforming to EN 60228, insulated with XLPE type GP8 conforming to BS 7655-1.3, extruded inner sheath with PVC conforming to BS 5467, armoured with galvanised steel round wire and sheathed with extruded FRPL PVC conforming to BS 5467, suitable for voltage rating 600/1000 V, maximum operation temperature 90 °C, maximum conductor temperature at short-circuit 250 °C, RED in colour, including laying, termination and ferruling complete all as specified and directed by engineer-in-charge.
M & L for transparent FR PVC insulated, twin core copper conductor flexible Speaker cable having stranded annealed tinned copper conductor, PVC insulated cores twisted to form pairs, shielded for interference rejection, unarmoured PVC sheathed 1.1 kV grade in conductor size 2 X 1.0 mm2 including laying, termination and ferruling complete all as specified and directed by engineer-in-charge.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required
Supplying and fixing 4 way(4+12 ) double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
LIGHTNING PROTECTION
M&L for fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
M&L for fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
M&L for fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor using synthetic insulator of suitable size of maximum 0.5 mm distance between two insulator complete as required.(For horizontal run)
M&L for fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor using synthetic insulator of suitable size of maximum 0.5 mm distance between two insulator complete as required.(For vertical run)
DG SET
Supply and installation and commissioning of 50 KVA of Silent Diesel Engine driven Generating set 415 Volts, 3 Phase 4 wire, emgine as per IS 10001/10002 and Alternater as per IS 13364 complete with relay panel and switch gears for automatic starting on main failure control panel having meter and sound proof canopy as per CPCB norms and foundation etc of capacity 50 KVA with synchronizing panel,mounted on a Base Frame placed over PCC foundations as per OEM recommendation with minimum 0.5 mtr all around space for easy movement around the generator. Alongwith:- (A) DIESEL DRIVEN ENGINE :- Developing a net output suitable matched to give a net rated output of suitable to drive 50 KVA alternator, at 0.8 power factor 415 volts. The engine should be capable of delivering the required output at 1500 RPM, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified. (i) Fly wheel to suit flexible coupling and fly wheel housing. (ii) Air cleaner complete as per manufacturer specification. (iii) Fuel injection pump. (iv) Flexible coupling with guard, nuts and bolts. (v) Fuel filter with mounting. (vi) Oil filter with mounting. (vii) Starter motor as per manufacture's design. (viii) Exhaust, silencer industrial type with exhaust pipe suitable length. (ix) Batteries 12 volts 1x180 AH maintenance free batteries with copper lead, terminals etc. (x) Instrument panel complete with microprocessor based controller comprising shut down valve indication, LCD hour counter indication, RPM indication , LED lamps for fail to start, over speed /under speed . Low lub oil pressure, high engine coolant temperature gaugae. (xi) Dynamo/alternator suitable rating. (B) ALTERNATOR:- The above engine will be coupled through flexible coupling on an indigenous alternator mounted in a strong steel fabricated common base frame suitable for mountingin an acoustic enclousre. The alternator will be 3 phase 50 HZ 1500 RPM self reglating self existing type and have class H insulation of stator and rotor windings and generate 50 KVA output at 0 .8 Power factor 4 wire 415 volts AC supply under NTP condition with a provision of 10% overload for 1 hour in every 12 hrs running. The alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.
(C) AMF PANEL :- S&F AMF (Automatic on mains failure) control panel CPRI approved outdoor type KIOSK ' water, dust and vermin proof and fabricated out of 3.15 mm thick CRCA sheet and 50mm x 50mm x 6mm angle iron powder coated fixed in PCC foundation suitable for 415 volts 3 phase 50 Hz AC supply with and incl the following :- (i) MCCB 125 Amps, 4 pole, 25 KA thermally adjustable between 80% - 100% of rated load, Ics=Icu. (ii) Necessary relays, times and power contractors of suitable rating/capacity for auto ON-OFF the DG set and changeover of the load in case of power failure. (iii) Digital mulfifunctional meter for phase wise reading of amps, voltage KWH and frequency -01 (iv) Internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses. (v) Earthing terminals 02 Nos (vi) Auto/Manual start switch to by pass auto start. (vii) Battery charging system suitable for charging for charging the battery provided with the DG Set incl boost/stickle switch and system, DC voltmeter digital type (D) FUEL TANK :- One No built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacity to run the DG for 12 Hrs countinuous running with inlet and outlet connection including the following :- (i) Level indicator with float and gauge. (ii) Fuel piping for fuel supply to engine and over flow to tank (iii) Fuel strainer (E) ACOUSTIC ENCLOSURE :- Enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per IS 8528 part 10 and as per approved CPCB morms. the acoustic encloure must consist of the following :- (i) CRCA sheet with body 16 SWG thick. (ii) Base frame fabricated from ISMC Channel (iii) Insulated rock wool fire retardant/non-igniting noice reduction type and properly clamped provided on all doors, roof and sides. (iv) Special designed SS doors locks and door hinges.. (v) Thermostate switch to shut off the engine in case the temperature inside the accoustic enclousre increases beyond 70 degree Celsus. (vi) Glass windows in acoustic enclousre suitably located to read/check the various meters and controls"
Supply and installation and commissioning of 58.5 KVA Silent Diesel Engine driven Generating set 415 Volts, 3 Phase 4 wire, emgine as per IS 10001/10002 and Alternater as per IS 13364 complete with relay panel and switch gears for automatic starting on main failure control panel having meter and sound proof canopy as per CPCB norms and foundation etc of capacity 58.5 KVA with synchronizing panel,mounted on a Base Frame, placed over PCC foundations as per OEM recommendation with minimum 0.5 mtr all around space for easy movement around the generator. Along with:- (A) DIESEL DRIVEN ENGINE :- Developing a net output suitable matched to give a net rated output of suitable to drive 58.5 KVA alternator, at 0.8 power factor 415 volts. The engine should be capable of delivering the required output at 1500 RPM, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified. (i) Fly wheel to suit flexible coupling and fly wheel housing. (ii) Air cleaner complete as per manufacturer specification. (iii) Fuel injection pump. (iv) Flexible coupling with guard, nuts and bolts. (v) Fuel filter with mounting. (vi) Oil filter with mounting. (vii) Starter motor as per manufacture's design. (viii) Exhaust, silencer industrial type with exhaust pipe suitable length. (ix) Batteries 12 volts 1x180 AH maintenance free batteries with copper lead, terminals etc. (x) Instrument panel complete with microprocessor based controller comprising shut down valve indication, LCD hour counter indication, RPM indication , LED lamps for fail to start, over speed /under speed . Low lub oil pressure, high engine coolant temperature gaugae. (xi) Dynamo/alternator suitable rating. (B) ALTERNATOR:- The above engine will be coupled through flexible coupling on an indigenous alternator mounted in a strong steel fabricated common base frame suitable for mountingin an acoustic enclousre. The alternator will be 3 phase 50 HZ 1500 RPM self reglating self existing type and have class H insulation of stator and rotor windings and generate 50 KVA output at 0 .8 Power factor 4 wire 415 volts AC supply under NTP condition with a provision of 10% overload for 1 hour in every 12 hrs running. The alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.
Technical Specifications :- (a) Prime Rating at rated rpm (as per ISO8528) - 58.5 KVA / 46.8 KW (b) Frequency - 50 Hz (c) Power Factor - 0.8 lagging (d) Voltage - 415 (3Ø)V (e) Governing class (As per ISO 8528 Part- V) - G2 (f) DG set Noise level at 1 meter - <75 (Genset with cano py) dBA (g) Fuel tank capacity (Standard DG set) minimum - 165 Ltrs (h) Weight of genset with canopy (approx.)^ - Dry : 1460 kg and Wet (w/o fuel) :1485 kg (j) Electrical Battery Start in R Voltage - 12 Volts-DC (k) Rated output (min) - 54.4Kw (l) No. of cylinder - 4 Nos (m) Prime Continuous rating as per ISO8528-1 - 74HP (n) Rated Speed -1500 RPM (o) Lube oil Sump Capacity (max) - 10 Ltrs (p) Coolant Capacity - 12.7 Ltrs (q) Insulation Class - C lass H (r) Alternator Efficiency (at 100% load) 0.8 pf - 90.8% (s) Max Voltage Dip at Full Load 0.8 pf lag - <20% (t) Max Time to build up rated voltage at Rated RPM - < 2 sec, provided engine reach the rated speed.
ARBORICULTURE
Preparng composit pits for size 0.60x0.60x0.60 by excavation in ordinary soil,applying antitermite treatment planting trees ad refilling of the pit with compost (manure sand and sweet earth mixed in ratio of 1:4 breaking colds, ramming and flooding with water incl removal of rubbish unserviceable materials and surplus soil to distance n.exc 100mtr,ATT shall be in form of 200gms neem cake mixed 2ml per litre in the first watering of 20ltrs per pi. Note:1 The rate for excavation and getting out of soil shall be deemed to be included in the unit rate of this item. Note 2: The rate for mixing earth manure and sand deemed to be included in the unit rate of this item
Supply and planting following trees in location where shown on drawing and described in Sch 'A' and specification / directed by Engr-in-charge,girth 80mm to 100mm minimum (measured at 150 mm top of roots) and heights as shown.
BOTTLE PALM 4 HEIGHT
ASHOKA PENDULA 4' TO 6' HEIGHT
LAMON TREE 2' TO 3' HEIGHT
AMLA TREE 2' TO 3' HEIGHT
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
DRG.pdf
Additional Documents • 18.98 MB
TDRDLI40.pdf
Tender Documents • 17.69 MB
BOQ_847120.xls
BOQ • 0.44 MB
SchduleofcreditDLI40.pdf
Additional Documents • 0.29 MB
Download all tender documents and submit your bid