Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.5 L+₹33,325.55 (0.87%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹38.5 L+₹40,841.95 (1.07%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹38.7 L+₹55,209.24 (1.45%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹38.8 L+₹62,099.41 (1.63%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
1 Sept 2021, 6:00 pmClosed
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
SPECIAL REPAIRS TO BULDG NO. T-111 AT KALIMPONG UNDER GE 867 EWS
2021_MES_463864_2
CA NO GE / 867 / TOKEN / 32 OF 2021-2022
Open Tender
Civil Works - Others
Item Rate
180 days
Kalimpong
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹69,000
Yes
18 Sept 2021
20 Aug 2021
2 Sept 2021
20 Aug 2021
1 Sept 2021
27 Aug 2021
20 Aug 2021 - 25 Aug 2021
Amount
S&F pre-painted galvalume aluminium zinc coating GI based corrugated (Trepezium or tiled pattern etc.,) steel sheet 0.50 mm thick (with 0.45 mm BMT) of any colour having tensile strength of 550 Mpa (pitch of corrugation shall be 200mm to 250mm and crest shall be 28mm to 32mm) as in roof covering/ cladding to wall fixed with self tapping screws including taking down existing steel sheeting of any type complete all as specified and directed by Engineer-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick (with 0.45 mm BMT) of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws including taking down existing steel sheeting of any type complete all as specified and directed by Engineer-in-Charge. Make for Item No. 1&2: TATA BLUESLOPPE/ LLYODS /JMBS/ EVEREST INDUSTRIES LTD/CRIL/JSW STEEL or equivalent as approved by GE.
Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for 25 mm thick plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in leveling coarse for tile floor complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick square/rectangular area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc., jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 15mm thick screed bed in cement mortar 1:6 or with chemical tile adhisive (SIKA) including dismantling existing tiles and removing rubbish off the premises complete all as specified and directed by Engr-in-charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick square/rectangular area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10mm thick rendering in cement mortar 1:4 or with chemical tile adhisive (SIKA) including dismantling existing tiles and removing rubbish off the premises complete all as specified and directed by Engr-in-charge. Make for Item No 5&6: NITCO/ SOMANY/ ASIAN / JOHNSON/ORIENT
M&L 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 6 mm wide grooves to full depth at 2m to 3m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in surface channels, drains including fair finishing inner surface of drain or channel using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilitate demolition including removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in chajjas and the like complete all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels exceeding 1.5 m span, bands etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
Use and removal of steel formwork to soffits of chajjas and similar item including edges, for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
Use and removal of steel formwork to sides and soffits of floor or roof beams, bands, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
M&L for Mild steel deformed TMT bars 10mm dia and above as in reinforcement to concrete cut to length bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed by Engr-in-charge.
M&L for Mild steel deformed TMT bars 8mm dia as in reinforcement to concrete cut to length bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed by Engr-in-charge.
M&Lfor Mild steel deformed TMT bars 5mm dia and over up to and including 10 mm dia as in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement including taking down cement plaster on brick or stone masonry surfaces of walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removing rubbish off the premises complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:4 finished fair and even including waterproofing compound @ 3% by weight of cement as per manufacturer's instructions including taking down cement plaster on brick or stone masonry surfaces of walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removing rubbish off the premises complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:4 finished fair and even including waterproofing compound @ 3% by weight of cement as per manufacturer's instructions complete all as specified and directed by Engr-in-charge.
M&L preparing new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of primer over thin layer of wall care putty (Birla white/Berger/Asian) complete all as specified and as directed by Engineer-in-Charge. Make: ASIAN/SHALIMAR/BERGER/ JENSON & NICHOLSON/IEL
M&L for preparing new plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces on external walls complete all as specified and directed by Engineer-in-Charge. Make: APEX of ASIAN or equivalent in JENSON & NICHOLSON/ BERGER/ SHALIMAR
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.), or insulation boards / slabs / blankets, anythickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
Dismantling timber scantling 40 Sqcm and over in section, in any position (framed work) complete all as specified and directed by Engineer-in-Charge.
Dismantling timber fillets, rails, posts, rafters, purlins etc., under 40 Sqcm in section, in any position complete all as specified and directed by Engineer-in-Charge.
S&F PVC false ceiling coloured choice of wooden pattern consisting of 600mm x 600mm , 5mm thick plain PVC sheet used as panels insert in a frame work made using andized aluminum T-section of size 25mm x 25mm, 19 gauge or 1mm thick in square pattern of grid size 600 x 600 mm. The aluminum frame work is supported from the ceiling with the help of J hook and GI wire /6mm M.S rods of required sizes to maintain proper level. The aluminum frame work is supported on side wall with the use of aluminum L-section of size 25 x 25 mm angle etc complete all as specified and directed. Make : Rajshri plastiwood or equivalent to Accura/Saint Gobain/Gypstone /Everest.
S&F Fe 410-W (Gde-E- 250) quality-A Rolled steel sections, joist, channel, angle, flat or Tee sections fixed independently with angle cleats or other connecting plates etc., complete all as specified and directed by Engineer-in-charge.
M&L for factory made precast cement block masonry with solid blocks made of Plain cement concrete 1:3:6 mix type C1 (using 20 mm graded stone aggregate) exceeding 10cm width and setting in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge. Make : Shankar Saw Mills/Sangam Prefeb Products or equivalent make as approved by GE.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each, complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.5 Sqm and not exceeding 4 sqm each, complete all as specified and as directed.
S&F 165x60 mm size pressed steel door frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including PCC 1:3:6 type C0 filling complete all as directed by Engr-in-Charge. Make: - DIWAN STEELS/AVA STEELS/AJANTA ISPAT or equivalent as approved by GE.
S&F 30mm thick 2nd class hard wood plain framed panelled shutters (any number of panels) with panels of 12mm thick timber flat on both sides (feather edged) or of 12mm thick veneered particle board ,medium density, wood particle board with commercial face veneers with sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats complete all as specified directed by Engr-in-charge.
S & F 35 mm thick second class hard wood Glazed and skeleton shutters for doors, open rebated and prepared to receive glass,gauze etc. without sash bars, edges of framing plain, chamferred or rounded, fitted with cut and mitred beads for securing glass, wire gauge etc. ; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats all as specified and directed. Timber for item Nos. 32 & 33:- Sal/Kalasiris/Chaplash/Hollock/Bijasal
S&F 200 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed.
S&F 150 mm long Aluminium alloy handles cast type anodised all as specified and directed.
S&F 250mm long aluminium alloy anodised sliding door bolts with hasp & staple (bolt type) and fixing clip of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and directed.
S&F 140mm Size door stoper aluminium alloy anodised body and tongue, with hard drawn steel spring fixed with screws complete all as specified and directed. Make for Item No. 34 to 37: - CROWN/ CLASSIC/ JYOTHI/ AMIT/ MOWJEE
S&F in repairs decorative type drapery rod (curtain rods) of 25mm dia powdercoated with fixing brackets, and knobs etc., complete all as directed by Engineer-in-Charge. MAKE: VISTA or equivalent in CROWN/ CLASSIC/ JYOTHI/ AMIT/ MOWJEE
S&F steel window with side hung shutters (glazed or wire mesh shutters) fitted with box type hinges with suitable MS handles, peg stays, with glazing bars for receiving glass / MS flat for receiving wire mesh complete all as directed by Engr-in-charge.
S&F steel window with side hung shutters (glazed or wire mesh shutters) fitted with box type hinges with suitable MS handles, peg stays, without glazing bars complete all as directed by Engr-in-charge. Make for Item No. 39&40: M/s Madhu industries / M/s.SEN Harvick / AVA STEELS /M/s. Shiv Mular / M/s. AGEW. / M/s. Multiwyn Industries Corpn/ M/s Ganesh rolling shutters/Ajanta Ispat or equvalent make as approved by GE.
M & L Plain cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in bed blocks for grouting hold fasts, coping, filling in pressed steel chowkats or similat work including necessary formwork, weathering, slightly rounded or chamfered andgles, finishing of exposed surfaces of concrete to fair and even complete all as specified and directed by Engineer-in-charge.
S&F Mild steel works as in grills, framed guard bars, and similar works conforming to Fe-290, Gde E-165 all as specified and directed.
S & F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden beeds all as specified and directed.
S & F 3mm thick sheet glass ordinary quality fixed with oil putty and necessary clips/nut bolts area not exceeding 0.5Sqm in each pane complete all as directed by Engr-in-Charge. Make :- TRIVENI/ SAINT GOBAIN/ MODIGUARD/ATUL/ HINDUSTAN or equivalent as approved by GE.
M&L Preparing new or previously un treated surfaces of wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
M&L M&L for preparation of new or previously un treated surfaces of steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L preparing old painted steel and iron surfaces of any description over 10 cm width or girth including and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Make for Item No. 45 to 47: ASIAN/ SHALIMAR/ BERGER/JENSON&NICHOLSON/IEL
M&L for cement concrete polished coloured chequered tiles 300 x300x 25 mm thick with grey cement and pigment, set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces as in floors over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. Make: NITCO/ULTRA/EUROCON/DECO/BHARAT or equivalent as approved by GE.
S&F 180 mm dia half round PVC (heavy grade) eaves gutter fixed with MS brackets complete all as directed by Engr-in-Charge. NOTE: MS brackets shall be measured and paid seperately.
S&F PVC (SWR) junction (Single T) equal or unequal suitable for 180mm eaves gutter, top portion half round and bottom portion to fit to 110mm bore PVC pipe complete all as directed by Engr-in-charge.
S&F PVC (SWR) pipes 110mm bore single socket in any length with rubber ring joints fixed to walls complete all as directed by Engr-in-Charge.
S&F PVC (SWR) bends (any radius) suitable for 110mm bore pipe fitted with access door complete all as directed by Engr-in-charge. Make for item No 49 to 52: PRINCE/ SUDHAKAR/ NANDI/ FINOLEX/ SWASTIK/SUPRIME or equivalent make as approved by GE.
M&L Mild steel work such as bands, straps, clamps and hold fasts, support for rain water pipes, gutters etc., of Fe-290 Gde E-165 all as specified and directed.
M&L for preparation of new or previously un treated surfaces of steel and iron surfaces of any description, not exceeding 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. Make: ASIAN/ SHALIMAR/ BERGER/ JENSON&NICHOLSON/IEL/NEROLAC/IEL
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/PVC terminal boxes surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.
All as per item No. 55 above but for One 3/5 pin switch socket outlet 5 amps on same board along with other switches complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/PVC terminal boxes surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge. Make for Item No. 55 to 57 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Casing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
S&F switch piano, flush button, single pole, 5 amps, one way complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate for batten fittings complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose 3 terminal PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 58 to 62: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
S&F 5 W retro fit B-22 LED lamp complete all as specified and as directed by Engineer-in-Charge. Make: Philips/Crompton/Havells.
S&F Energy efficient LED Tube light fitting, 4', 1x18 watt, with LED tube rod 18 Watt with bipin holders, connector block etc., complete with all accessories internally prewired and including connecting up with three core pvc sheathed flexible copper conductor cable of size 0.5 sqmm and 2 Nos PVC mounting blocks including taking down existing fitting complete all as specified and as directed by Engineer-in-Charge. Make: Philips Model Batten TMC 501, TMC 501P 1xT-LED 22 W P3241 Tube rod MAS LED tube 18W 1800lm 865 T8 or equivalent in Crompton/Havells.
Supply, Fixing, Testing & Commsioning of IP66 & IK09 integral LED Bulk Head luminaire with housing made of Pressure Die Cast alumunium & Optical cover made of Opal Polycarbonate for glare free lighting . System Lumen Output of minimum 600 lumens. Power Consumption should not exceed 10W (Including Driver Loss). For Glare free lighting luminaire should be with Opal diffused Polycarbonate, Color temperature 6500 K, CRI >80, Housing - High pressure die cast aluminum, Mounting - Surface, THD < 20%, PF >0.9, Operating voltage range 120V-277V AC. Submission of LM80-08 for LED source & LM79-08 for Luminaire from third NABL Accredited Lab / UL mandatory including connecting up with 3.0 core, 0.5 sqmm copper conductor sheathed including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. MAKE: Philips, Cat part No. "WT 202W LED 6S CW PSU S2 PC", or equivalent in Crompton /Havells
S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated, double door including taking down existing DB with MCBs complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SPN 40 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SP 6 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 66 to 68: Legrand/Siemens/Schindler
M&L for sub main wiring complete with 2 runs of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC casing and capping of suitable size fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge. Note: 2 runs of 6 Sqmm and one run of 6 Sqmm and one run of conduit shall be measured as one unit length. Make Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Casing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
S&F LED security light suitable for 35 W LED with pressure di cast housing with epoxy power coated drak graphite grey colour finish , Prismatic ploycarbonate cover with individual LED lenses, IP65 including bracket made out of 25 mm dia light grade GI pipe not less than 1.2 mtr long bend to shape duly fixed with MS clamps of 3mm thick, nut, bolts etc complete fixed to wall complete including taking down existing fitting all as specified and as directed. Make: Crompton/Havells/Bajaj/Philips/Wipro.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of pipe, cable etc., or for shafts, wells, cesspits, manholes, pier holes, etc., not exceeding 10 sqm on plan and getting out in soft/loose soil all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removing surplus excavated soil to a distance not exceeing 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Supply and spreading of dry river sand in trenches for cable protection and punned down complete all as directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
Supply and laying unreinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge. Note:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Dismantling / Taking out Unserviceable service cables of size upto 35 sqmm from any position i.e ground / walls / poles / roofs including GI service bracket etc complete with protection pipe all as specified and directed by Engineer-in-Charge.
Material and labour for 40 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge. Make: TATA/ZENITH/JINDAL
M&L for rendering 10 mm thick on concrete surfaces of ceiling in cement mortar 1:3 finished fair and even including taking dowm existing plaster and removing rubbish off the premises complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered ceiling surfaces and applying 3 coats of white wash complete all as specified and directed by Engr-in-charge. MAKE: Suryacem/Janatacem/Luckycem or equivalent as approved by GE.
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 83,160.00 B/F from Ser page No. 31 NOTE: Bidder shall insert credit amount as rate Rs. 83,160.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
PRASAD PRADHAN AND SON
G K SUTHAR
RAMESH GURUNG
RAJU TAMANG
HEM RAJ GURUNG
JAYSHREE CONCERN
DEEP CHANDRA JOSHI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .