| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC 121004 | L1 | Accepted-AOC BEING LOWEST TENDER | |
| 2 | L2₹47.3 L+₹38,346.69 (0.82%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹48.3 L+₹1.3 L (2.84%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹48.6 L+₹1.6 L (3.45%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹49.2 L+₹2.2 L (4.73%)Rejected-Finance 31 CHAIRMAN KARUPPANA THEVAR STEET SULUR COIMBATORE 641 402 | COIMBATORE | TAMIL NADU | 641402 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | eurekaenterprises L3 | CAK Enterprises L6 | pk janardhanan L4 | Neptune Engineers and Builders L1 | p.chinnasamy L8 | NLK Construction L9 | SARAVANARAJA CONSTRUCTIONS L2 | A.GOVINDARAJ L7 | KAARTHIC BUILDERS L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A BOQ | ||||||||||||
| 2.00 | Repair, maintenance and making the continuity of supply for rectifying the defects including taking down defective electrical items such as light point, call bell point, socket point 5A/15A, switches, sockets, lamp holder, brackets, bell, buzzer, push button, ceiling rose, pendent, any type of MCB's, SPN DB's any type of internal light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection including provision of small pieces of elctrical cable of size upto 2.5 sqmm single core and length not exceeding 0.50m complete all as specified and as directed. | 3,350 | Each Job | 160 ₹5,36,000 | 195 ₹6,53,250 | 150 ₹5,02,500 | 250 ₹8,37,500 | 225 ₹7,53,750 | 200 ₹6,70,000 | 140 ₹4,69,000 Lowest | 210 ₹7,03,500 | 182 ₹6,09,700 |
| 2.01 | Note:- following shall be part of job under item No 2:- | - | - | - | - | - | - | - | - | - | - | - |
| 2.02 | (a) The above job shall be carried out by a trained skilled electrician alongwih helper | - | - | - | - | - | - | - | - | - | - | - |
| 2.03 | (b) checking of all bldg(domestic and otm) internal electrfication complaints including service connections, submain & fixtures for entire Domestic & otm AOR as mentioned in subject work area of AF Stn sulur shall be attended. | - | - | - | - | - | - | - | - | - | - | - |
| 2.04 | (c) Daily complatints shall be collected from CMDS scada room,record of complaints/complaint slip showing qtr No, bldgs No, locatoin nature of job supported with users signature shall be prepared as per format directed & will be deposited to concerned JE E/M within 24 hrs. | - | - | - | - | - | - | - | - | - | - | - |
| 2.05 | (d) Necessary complaints slip/complaints register & other stationary required shall be provided by contractor .deemed rate shall be inclusive in unit quoted rate. | - | - | - | - | - | - | - | - | - | - | - |
| 2.06 | (e) All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept. | - | - | - | - | - | - | - | - | - | - | - |
| 2.07 | (f) Defective items if any, required to be replaced shall be measured and paid separately under relavant items. | - | - | - | - | - | - | - | - | - | - | - |
| 2.08 | (g) The quoted rate is deemed to be inclusive for small pieces of elctrical cable of size upto 2.5 sqmm single core and length not exceeding 0.50m | - | - | - | - | - | - | - | - | - | - | - |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
2 Jul 2025, 6:00 pmClosed
GE AF SULUR
KANGAYAPALYAM
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION FITTINGS, FIXTURE MAIN DISTRIBUTION BOARDS, BLDG EARTHING, INTERNAL ELECTRIC SUPPLY SERVICES AND OTHER E/M WORKS IN ALL SMQ ACCN DOMESTIC AREA AT AF STN SULUR
2025_MES_713998_1
8755/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer to tender documents
7 documents required · 7 mandatory
₹500
GE AF SULUR
₹92,000
20 Sept 2025
12 Jun 2025
4 Jul 2025
12 Jun 2025
2 Jul 2025
25 Jun 2025
14 Jun 2025 - 23 Jun 2025
Amount
SCHEDULE A BOQ
Repair, maintenance and making the continuity of supply for rectifying the defects including taking down defective electrical items such as light point, call bell point, socket point 5A/15A, switches, sockets, lamp holder, brackets, bell, buzzer, push button, ceiling rose, pendent, any type of MCB's, SPN DB's any type of internal light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection including provision of small pieces of elctrical cable of size upto 2.5 sqmm single core and length not exceeding 0.50m complete all as specified and as directed.
Note:- following shall be part of job under item No 2:-
(a) The above job shall be carried out by a trained skilled electrician alongwih helper
(b) checking of all bldg(domestic and otm) internal electrfication complaints including service connections, submain & fixtures for entire Domestic & otm AOR as mentioned in subject work area of AF Stn sulur shall be attended.
(c) Daily complatints shall be collected from CMDS scada room,record of complaints/complaint slip showing qtr No, bldgs No, locatoin nature of job supported with users signature shall be prepared as per format directed & will be deposited to concerned JE E/M within 24 hrs.
(d) Necessary complaints slip/complaints register & other stationary required shall be provided by contractor .deemed rate shall be inclusive in unit quoted rate.
(e) All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
(f) Defective items if any, required to be replaced shall be measured and paid separately under relavant items.
(g) The quoted rate is deemed to be inclusive for small pieces of elctrical cable of size upto 2.5 sqmm single core and length not exceeding 0.50m
(h) The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the dept.
(j) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(k) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The JE/AGE shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to JE/Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaints shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of double recovery per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(l) The decision of the Accepting Officer in this regard shall be final and binding.
Supply & fix LED driver 9-10W suitable for building security light including takng down old u/s complete all as specified and directed.
Supply & fix LED driver 15-20W suitable for building security light including takng down old u/s complete all as specified and directed.
Supply & fix single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for exisiting loads(curve shall be provied as per existing loads 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified.
Supply & fix electric bell, AC 230 volt,50hz single pole Ding Dong type inclduing taking down old u/s item complete all as specified and directed.
Supply & fix 7 watt LED lamp with self intigrated driver suitable B-22 holder caps inclduing taking down old u/s item complete all as specified and directed. complete all as specified and directed.
Supply & fix plug top 3 pin, 15 amps AC 230 volts ,50Hz complete inclduing taking down old u/s item complete all as specified and directed.
Supply & fix plug top 3 pin 5 amps AC 230 volts 50Hz complete inclduing taking down old u/s item complete all as specified and directed.
Supply & fix bakelite sheet not less than 3 mm thick of size 100 x 100 mm including takng down old u/s complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new TP, MCB 25 to 63 amp, 415 v, 50 Hz AC suitable (load curve shall be provided as per exisitng loads), 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified.
Disconnecting & taking out unserviceable one and replacemet with new TPN, MCB 16 to 32 amp, 415 v, 50 Hz AC suitable (load curve shall be provided as per exisitng loads) , 10 KA breaking capacity complete conforming to IS all as specified.
Disconnecting & taking out unserviceable one and replacemet with new TPN, MCB 40 to 100 amp, 415 v, 50 Hz AC suitable (load curve shall be provided as per exisitng loads) , 10 KA breaking capacity complete conforming to IS all as specified.
Supply & fix insulation tape 25 mm width 10m long
Supply & fix PVC rectangular/square block 75mmx75mmx35mm including takng down old u/s complete all as specified and directed.
Supply & fix 4' 20W/ 18W LED tube rod suitable for existing fitting.
Supply & fix bell push type 5 Amps 240 volts single pole one way including takng down old u/s complete all as specified and directed..
Supply & fix switch piano flush type 5 Amps 240 volts,50hz single pole one way including takng down old u/s complete all as specified and directed..
Supply & fix switch piano flush type 5 Amps 240 volts,50hz single pole two way including takng down old u/s complete all as specified and directed..
Supply & fix switch piano flush type 15/16 Amps 240 volts,50Hz single pole one way including takng down old u/s complete all as specified and directed..
Supply & fix shuttered socket outlet 3 pin 5 amps, 240 volts,50Hz flush type including takng down old u/s complete all as specified and directed..
Supply & fix shuttered socket outlet 2 in 1, 5 pin, 240 volts,50Hz 5 and15 amp including takng down old u/s complete all as specified and directed.
Supply & fix switch socket combination out let 3 pin 5 amps, flush type including takng down old u/s complete all as specified and directed.
Supply & fix switch socket combination out let 5 in 1, 5 pin 5 and 15 amps, flush type including takng down old u/s complete all as specified and directed..
Supply & fix for Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked including takng down old u/s complete all as specified and directed..
Supply & fix lamp holder, insulated body, cord grip pattern SP 230 volt, 50Hz,including takng down old u/s complete all as specified and directed..
Supply & fix PVC gang box 1 way 05 amp including takng down old u/s complete all as specified and directed. .
Disconnecting & taking out unserviceable one and replacemet with new Isolator SPN 40 amp, 240 v, 50 Hz AC suitable 10 KA breaking capacity complete conforming to IS all as specified
Disconnecting & taking out unserviceable one and replacemet with new SPN 40 to 63 AMP, 240 v, 50 Hz AC suitable forcurve, 10 KA breaking capacity complete conforming to IS all as specified.
Supply & fix 9 watt LED lamp with self intigrated driver suitable B-22 holder caps inclduing taking down old u/s item complete all as specified and directed.
Supply & fix PVC gang box 2 way inclduing taking down old u/s item complete all as specified and directed. .
Supply & fix bakelite sheet not less than 3 mm thick of size 175 x 100mm complete all as specified and as directed inclduing taking down old u/s item complete all as specified and directed. .
Supply & fix bakelite sheet not less than 3 mm thick of size 200 x 200mm complete inclduing taking down old u/s item complete all as specified and directed.
Supply & fix bell push, modular 1 way inclduing taking down old u/s item complete all as specified and directed. .
Supply & fix bakelite sheet not less than 3 mm thick of size 200 x 250mm complete all as specified and as directed.
Supply & fix bakelite sheet not less than 3 mm thick of size 250 x 300mm complete all as specified and as directed.
Supply & fix modular switch 1 way 6 amp.1 module inclduing taking down old u/s item complete all as specified and directed. .
Supply & fix modular Socket, 6A - 2/3 pin combined 2 module inclduing taking down old u/s item complete all as specified and directed. ..
Supply & fix modular switch 1 way 16 amp.1 module inclduing taking down old u/s item complete all as specified and directed. ..
Supply & fix modular Socket, 16A - 2/3 pin combined 2 module inclduing taking down old u/s item complete all as specified and directed. ..
Supply & fix modular white cover plate with frame,3 module inclduing taking down old u/s item complete all as specified and directed. ..
Supply & fix modular white cover plate with frame,4 module inclduing taking down old u/s item complete all as specified and directed.
Supply & fix modular white cover plate with frame,6 module inclduing taking down old u/s item complete all as specified and directed.
Supply & fix modular white cover plate with frame,8 module inclduing taking down old u/s item complete all as specified and directed.
Supply & fix modular white cover plate with frame,12 module inclduing taking down old u/s item complete all as specified and directed.
Supply & fix in repair rigid, non-matalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories complete all as specified and as directed.
Supply & fix in repair rigid, non-matalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories complete all as specified and as directed.
M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm/ 25x4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicatedincluding testing on completion. and Testing on Completion including excevation and returning filling & taking down old unserviceable one, complete all as per specified and as directed.
Note for Item here in above :- (a) All Joints should be joined by Exothermic Welding or Brazing or nut bolts tightly.
(b) After completion of work earthing shall be tested by the contractor in presence of JE/Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to dept till desired result is obtained.
M&L in repairs Galvanised Earth strip of size 25 x 4 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
M&L for wiring for circuit complete submain wiring with 2 runs of 1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl onr run of 1.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etce and all as specified. Note:- (a) 2 runs of 1.5 sqmm cable along with one run of 1.5 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of load & source cable end terminations with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC Conduit and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of load & source cable end terminations with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of load & source cable end terminations with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two runs of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 4 runs of 6 sqmm cable along with two runs of 6 sqmm cable for earth conductor and one run of PVC casing caping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 4 runs of 4 sqmm cable along with two runs of 4 sqmm cable for earth conductor and one run of PVC casing caping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Disconnecting & taking out unserviceable one and replacemet with new 4 feet 18/20 Watt LED light fitting batten type with Luminaries & integrated driver batten with lumen out not lessthan 110 lumens/watts & extruded polycorbanate housing square shaped diffuse suitable for mounting on wall/surface/ceiling 230 volts with extruded aluminium heat sink provided for efficient heat dissipation,permisible limit of CRI range,with recommended burning hours,4000K/5700k/6500K etc complete with all accessories internally pre wired and necessary mounting arrangements, including provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including taking down old unserviceable fittings any type complete all as specified and as directed .
Disconnecting & taking out unserviceable one and replacemet with new 2 feet 9/10 Watt LED light fitting batten type with Luminaries & integrated driver batten with lumen out not lessthan 110 lumens/watts & housing extruded polycorbanate housing square shaped diffuse,permisible limit of CRI range,with recommended burning hours,4000K/5700k/6500K etc suitable for mounting on wall/surface/ceiling including taking down old unserviceable fittings any type complete all as specified and as directed
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed.
One light point/fan/bell point controlled by one switch
All as per item No. 61 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 61 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 61 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L point wiring for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed.
One light point/fan/bell point controlled by one switch
All as per item No.62 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 62 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 62 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 63 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 63 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 63 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 64 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 64 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 64 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 3-ph,12 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCCB 63-125Amps,minimum 3pole & minimum kA rating is 16kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 3-ph,8 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCCB 63-125Amps,minimum 3pole & minimum kA rating is 16kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 3-ph,6 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCCB 63-125Amps,minimum 3pole & minimum kA rating is 16kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 3-ph,4 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCCB 63-125Amps,minimum 3pole & minimum kA rating is 16kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board TPN, 3-ph,4 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCB 40-100Amps,minimum 3pole & minimum kA rating is 10kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
S&F in repairs modular type fan regulator 120W, 230 V ,50hz including provison all necessary wiring and connection complete including takng down old unserviceable from its locations complete all as specified and directed
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board SP & N 8 way double door, including bus bar , Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS all as specified.
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board TPN, 4 way single door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS all as specified.
Disconnecting & taking out unserviceable one and replacemet with new MCCB 4 pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IS complete all as specified.
Disconnecting & taking out unserviceable one and replacemet with new Energy saving new generation 10 watts with lumen effiency not less than 100lumens/watt,LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements ,permisible limit of CRI range,with recommended burning hours,4000K/6500K etc provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and removal old existing unsv tube light fitting complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new SP & N 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS all as specified.
Disconnecting & taking out unserviceable one and replacemet with new MCCB four pole, 63Amps ultimate breaking capacity 16 KA complete conforming to IS complete all as specified.
Supply & fix in repair 5 watt LED lamp complete all as specified and directed .
S&F 9 watt surface mounted sleek square down lighter enviornment friendly, new generation, energy saving with high power LED as light sources & clear glass including accessories complete all as specified and as directed.
S&F Surface & wall mounted LED fitting including capacity not less than 5 watt LED tube rod complete with all accessories internally, pre-wired, connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing building security luminaire of watt not less than 10 watt LED , not less than100 lumens/watt light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and all as specified and directed,
Supply and fixing building security luminaire of watt not less than 20 watt LED , not less than100 lumens/watt light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and all as specified and directed,
Supply and lay XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
Supply and lay XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
Supply and lay XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep in soft/loose soil and getting out for taking down/laying of pipes complete all as specified and directed.
Returning, refilling including spreading levelling watering and well ramming in layers not exceeding 25cms thick in hard/dense soil complete all as specified and directed.
Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed. Note :- In case sufficient sand not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge.
M&L Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid/surface/roof including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from notless than 110 lumens/watt.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection not less than 2KV ,permisible limit of CRI range,with recommended burning hours,4000K/5700k/6500K etc frequency 50 to 60 Hz ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , . PF should be notless than 0.95 , THD < 10% . Indivisual LED's should not be visible for glare free output
Disconnecting & taking out unserviceable one and replacemet with new pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MD land including taking down existing one all as specified and directed by Engineer-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new LED flood light 25 watt 230 V AC lumen output not less than 100 lumens /watt outdoor type with thermal management in multiple optics and equipped with minimum IP65 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed.
Supply & fix double pole RCCB minimum 25 Amps, minimum 100mAmps, 240 v, 50 Hz AC suitable for exisiting loads(curve shall be provied as per existing loads 10 KA breaking capacity conforming to IS including taking old unsericeable one all as specified.
Supply & fix LED driver 36-40W suitable for 2x2 light including takng down old u/s complete all as specified and directed.
SARAVANARAJA CONSTRUCTIONS (BID ID -3344085)
eurekaenterprises (BID ID -3341372)
pk janardhanan (BID ID -3343962)
KAARTHIC BUILDERS (BID ID -3343950)
CAK Enterprises (BID ID -3342553)
A.GOVINDARAJ (BID ID -3344509)
p.chinnasamy (BID ID -3343974)
NLK Construction (BID ID -3344037)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .