| 1 | L1₹10.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹12.7 L+₹1.6 L (14.8%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹13.0 L+₹2.0 L (17.7%)Rejected-Finance RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹14.3 L+₹3.2 L (29.4%)Rejected-Finance VILL PO POOH DISTT KINNAUR 172111 HP | KINNAUR | HIMACHAL PRADESH | 172111 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹16.1 L+₹5.0 L (45.7%)Rejected-Finance VILLAGE PO KOTHI TEH KALPA DISTT KINNAUR HP 172107 | KINNAUR | HIMACHAL PRADESH | 172107 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
19 Apr 2024, 6:00 pmClosed
GE 863 EWS
GE 863 EWS c/O56APO
REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY PIPELINES SLUICE VALVES AND OTHER CONNECTED WORS AT POOH UNDER AGE EM WE IN GE 863 EWS
2024_MES_648187_1
GE 863/EWS-T-83 OF 2023-24 REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY PIPELINES SLUICE VALVES AN
Open Tender
Civil Works - Water Works
Item Rate
180 days
Pooh
As PER NIT
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹28,000
Yes
27 Jun 2024
28 Mar 2024
22 Apr 2024
28 Mar 2024
19 Apr 2024
10 Apr 2024
28 Mar 2024 - 17 Apr 2024
Amount
Excavation in tranches in soft loose soil not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth for laying of pipes in tranches and getting out including levelling of bottom surface and trimming of sides after removal of existing GI/HDPE pipes and fittings complted all as specified and directed.
Returning filling in including spearing levelling, waering and well ramming in layers not exceeding 25 cm thick each excavated soft/hard soil in trenches after the pipes havew been laid and tested competed all as specified and directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge
Supply, Laying and testing in replacement 3 layer PP-R polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R Plain & brass threaded polypropylene random fitting for 20mm outer dia of pipe complete all as specified and directed.Note Excavation an earth wrok shall be paid separately.
All as per ser 4 item No here in before but of size 25mm (outer diameter of pipe) complete all as specified and directed.
All as per ser 4 item No here in before but of size 32mm (outer diameter of pipe) complete all as specified and directed.
All as per ser 4 item No here in before but of size 40mm (outer diameter of pipe) complete all as specified and directed.
All as per ser 4 item No here in before but of size 50mm (outer diameter of pipe) complete all as specified and directed. Note;- Item No 4 to 8 for PP-R pipes connecting fittings like PP-R (sockets, elbow, Tee sockets, reducer, unions and etc.. of both plain and brass threaded type are included in quoted rates..
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of outer dia 20mm complete all as specified and directed.
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 25mm dia complete all as specified and directed.
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 32mm dia complete all as specified and directed.
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 40mm dia complete all as specified and directed.
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 50mm dia complete all as specified and directed.
M & L for providing aluminium cladding over insulation of PPR pipe of size 20mm dia with aluminium sheet having thickness 0.2mm all as specified and directed
M & L for providing aluminium cladding over insulation of PPR pipe of size 25mm dia with aluminium sheet having thickness 0.2mm all as specified and directed
M & L for providing aluminium cladding over insulation of PPR pipe of size 32mm dia with aluminium sheet having thickness 0.2mm all as specified and directed
M & L for providing aluminium cladding over insulation of PPR pipe of size 40 mm dia with aluminium sheet having thickness 0.2mm all as specified and directed
M & L for providing aluminium cladding over insulation of PPR pipe of size 50 mm dia with aluminium sheet having thickness 0.2mm all as specified and directed
Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 20mm outer dia of pipe in mm compete all as specified and directed.
Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 25mm outer dia of pipe in mm compete all as specified and directed.
Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 32mm outer dia of pipe in mm compete all as specified and directed.
Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 40mm outer dia of pipe in mm compete all as specified and directed.
Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 50 mm outer dia of pipe in mm compete all as specified and directed.
Supply & fixing PP-R Ball Valves in replacement (brass inserted) suitable for PPR pipe line of size 20mm
Supply & fixing PP-R Ball Valves (brass inserted) suitable for PPR pipe line of size 25mm
Supply & fixing PP-R Ball Valves in replacement (brass insert) as per requirement of the site of size 32 mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
Supply & fixing PP-R Ball Valves in replacement (brass insert) as per requirement of the site of size 40 mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
Supply and fixing in replacment ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, 25 mm bore dia with rod complete all as specified and directed
S&F in replacment Rotation moulded poly-ethylene water storage tanks (cylinderical vertical with closed top) tripple layer of capacity 2000 Ltr hoiseted and fixed in position complete all as specified & directed.
S&F in replacment Rotation moulded poly-ethylene water storage tanks (cylinderical vertical with closed top) tripple layer of capacity 5000 Ltr hoiseted and fixed in position complete all as specified & directed.
S&F in replacement PUF insulated cylndrical tank of capacity 500 Ltr Vertical type double layer duly filled with puf insulation superior quality to resist in temp -30 to +35 degree centigrade alongwith hiknged top lid of same material with locking arrangement and hoisted on platform complete with making pipeline connection with the following specification :- Inner tank will be double layered HDPE food grade material Outer 4mm thick FRP jointless casing of tank. Thickness of PUF insulation shall be 75mm Minimum density of PUF insulationshall be 44 kg per/cum+ 10%.
S&F in replacement PUF insulated cylndrical tank of capacity 1000 Ltr Vertical type double layer duly filled with puf insulation superior quality to resist in temp -30 to +35 degree centigrade alongwith hiknged top lid of same material with locking arrangement and hoisted on platform complete with making pipeline connection with the following specification :- Inner tank will be double layered HDPE food grade material. Outer 4mm thick FRP jointless casing of tank.Thickness of PUF insulation shall be 75mm Minimum density of PUF insulationshall be 44 kg per/cum+ 10%.
M&L for opening and rewinding of electric motor 5 HP, 50 Hz 400/ 415 volts of mono block/ centrifugal electric motor of any make and type with super enameled copper winding wire of existing size including bearing bushes and other accessories etc required to make motor functional and testing on load and closing the motor after rewinding including transportation to workshop and back at site complete all as specified and as directed.
M&L for opening and rewinding of electric motor 10 HP, 50 Hz 400/ 415 volts of mono block/ centrifugal electric motor of any make and type with super enameled copper winding wire of existing size including bearing bushes and other accessories etc required to make motor functional and testing on load and closing the motor after rewinding including transportation to workshop and back at site complete all as specified and as directed.
M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surface of Puff storage tanks of capacity upto 500 ltrs from bottom and wall by using brushes, bleaching poder and other cleaning materials as directed including writing the words "TANK CAPACITY AND DATE OF CLEANING" in capital letters of synthetic enamel white paint over black back ground complete all as specified and as directed.
M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surface of Puff storage tanks of capacity upto 1000 ltrs from bottom and wall by using brushes, bleaching poder and other cleaning materials as directed including writing the words "TANK CAPACITY AND DATE OF CLEANING" in capital letters of synthetic enamel white paint over black back ground complete all as specified and as directed.
M&L for PCC 1:4:8 D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete ass as specified and directed.
M&L for precast cement concrete block masonary in 1:3:6 type C1 using 20 mm graded stone aggregate with solid block exc. 10 cm width and setting in CM 1:6 including demolition of block massonary complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using20mm graded stone aggregate as in coping, filling and mass concrete complete as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on external surfaces of brickwork/concrete surface, finished fair and even complete all as specified.
S & F of brass Non- return valve (NRV) in replacement threaded type suitable for PPR pipe of 25 mm dia including suitable PPR sockets of thread type all as specified and directed.
S & F of brass Non- return valve (NRV) in replacement threaded type suitable for PPR pipe of 32 mm dia including suitable PPR sockets of thread type all as specified and directed.
S & F of brass Non- return valve (NRV in replacement) threaded type suitable for PPR pipe of 40 mm dia including suitable PPR sockets of thread type all as specified and directed.
S & F of brass Non- return valve (NRV) in replacement threaded type suitable for PPR pipe of 50 mm dia including suitable PPR sockets of thread type all as specified and directed.
Schedule of Credit
R B TRADERS
MRITUNJYA ASSOCIATES
M/S Shamsher Negi Dewa
M/S Gopal Singh
M/S Gulab Singh
JAMDAGNI ENGG WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .