Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹15.3 L+₹1.5 L (10.7%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹16.4 L+₹2.6 L (19.1%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹16.6 L+₹2.8 L (20.0%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L4 | Rejected-Finance BEING OTHER THAN L1 | |
| 5 | L5₹17.4 L+₹3.6 L (26.2%)Rejected-Finance | L5 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
25 Nov 2019, 6:00 pmClosed
GE M AF JALAHALLI
GE M AF JALAHALLI BANGALORE
REPAIRS AND MAINTENANCE OF INTERNAL ELECTRIFICATION AT OFFRS ACCN MAP QTRS AND ACCN AT GANGAMMA CIRCLE EAST AREA UNDER GARRISON ENGNEER M AF JALAHALLI BANGALORE
2019_MES_295196_1
8453/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
JALAHALLI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE M AF JALAHALLI
₹46,000
Yes
19 Jun 2020
5 Nov 2019
27 Nov 2019
6 Nov 2019
25 Nov 2019
18 Nov 2019
6 Nov 2019 - 13 Nov 2019
Amount
Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground surrounded from all sides by 15cm thick and packed layer of charcoal dust and conmmon salt filling in alternate layers connected to and including GI earth strip 32 x 3 mm size upto 7.5 mtr by means of bolts, nuts, check nuts and washers, and protected by light grade 40 mm dia and connected to main control board/DG Set and GI pipe medium grade 20mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with P C C 1:2:4 Type C2 (including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 metre and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
Supply & fix in replacement earth continiuty conductor or main earthing lead fixed on wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to pole or any other indicated suituation for loop earthing etc, as required for aluminium strip 25x3.15 mm with proper saddles/spacer, screw etc, alll as specified and directed. Note : All joints of copper shall be of brazing only
Supply & fix in repair for 20 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches complete all as specified.
Supply & fix in replacement Bib Tap of 20 mm dia standard of PTMT any colour high pressure screwed for iron pipe (Minimum weight 125 gms) all as specifed and directed. Make Prayag, Princes, Supreme
Cutting the existing GI pipe of any size for tapping or new connection with 25 mm including required fitting all as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying pipe line and getting out in soft/loose soil as specified.
Returning filling in including spreading leveling watering and well ramming in layers not exc 25cm thick with dry type of soil all as directed.
Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting Per Point complete all as directed.
Taking down carefully aluminium Per Point wiring (light, fan, socket or power) complete and making good disturbed surfaces of walls, floors, etc. all as directed.including taking down fittings such as switches, ceiling roses, regulators, sockets,lamp holders, ceiling fittings, bulk head fittings, tube light fittings etc
Material and labour for Per Point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm concecled in wall including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm for One light Per Point controlled by one switch one way 5 Amps all as specified and directed. (Note : Cost of for cutting chesing and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate.)
All as per Sl Item no.10 but with One ceiling fan Per Point controlled by one ,one way 05 amp switch
All as per Sl Item no.10 but with One light Per Point controlled by one ,two way switch 5 amp
All as per Sl Item no.10 but with One exhaust fan Per Point controlled by one way switch 5 amp
All as per Sl Item no.10 but with One call bell Per Point controlled by one ,one way 05 amp bell push
All as per Sl Item no.10 but with One 2/3 pin socket outlet 5Amps on independent board
All as per Sl Item no.10 but with One 3 pin socket outlet 5 Amps on the same board with other switches
All as per item No 10 above but one switch socket combination 15 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm
Supply & fix switch piano flush type single pole one way switch 5 Amps
Supply & fix switch piano flush type single pole two way switch 5 Amps
Supply & fix switch socket combination 2 in 1, 5 Amps flush type
Supply & fix switch socket combination multipurpose 5 A/16 Amps,5 in1,flush type.
Supply & fix ceiling rose surface bakelite 3 terminals 65x50mm all as directed.
Supply & fix ceiling fan regulator electronic socket type 100 to 180 Watt surface step type
Supply and fix in repair Modular switch 1way 6A,1module
Supply and fix in repair Modular socket, 6A-2/3 pin combined 2 module
Supply and fix in repair Modular socket, 6A/16A-2/3 pin combined 2 module
Supply and fix in repair Modular fan step regulator, 120w-2module
Supply and fix in Modular switch 1way 16A,1module
Repairs to recessed mounting/ ceiling light fitting of any type of 9/18/20/28/36 watt including replacing all the unserviceable parts such as, choke, lamp holders all as directed. Note: (i) The unit rate quoted shall be deemed to include for replacement of worn out bolts, nuts, screws ,washers, partly wiring etc wherever required. (ii) Spares such as holder, choke, CFL,tube rod will be paid separately under respective items.
Supply only elelctronoic / copper ballast 36 w suitable for CFL/tube light fitting
Supply only elelctronoic ballast 28 w suitable for t-5 tube light fitting
Supply only starter suitable for 36 watt tube light fitting
Supply only tube rod 28 watt
Supply only tube rod 36 watt
Supply only tube rod 14 watt
Supply only Modular socket 6A 2/3 pin combined 2 module
Supply only Modular socket 6A16A, 2/3 pin combined 2 module
Supply & fix in repair of switch piano flush type single pole one way 5 Amps complete all as specified & directed.
Supply & fix in repair of switch socket combination 2 in 1, 3 pin 5 Amps flush type complete all as specified & directed.
Supply & fix in repair of switch socket combination 2 in 1, 5 Amps and 15 Amps flush type complete all as specified & directed.
Supply & fix in repair of Switch socket combination multipurpose 5/16 Amps, 5 in 1, 4 / 5 hole flush type complete all as specified & directed.
Supply & fix in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc
Supply & fix in repair Lamp holder angle type made of PVC/Polycarbonate with back plate.
supply & fix E-Lite LED curve with wide angle profile.High lumen batten with efficicency of 100 Lumens 9 w LED 6000k. Make : Havells. CAT E-LITE LED CURVE. CODE: LHEXBXP7PN1W09. HSN CODE 9405 or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix E-Lite LED curve with wide angle profile.High lumen batten with efficicency of 100 Lumens 20 w LED 6000k. Make : Havells. CAT E-LITE LED CURVE. CODE LHEXBXPNIN1W020. HSN CODE 9405 or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix in E-Lite LED Adore 7 W B22 CDL Ball LampLHLDERUEML8X007 685 Lumens 6500 k. Lamp Dimension (mm) Length102, Dia 56. Base Cap B22 HSN Code 8539. Make : Havells. or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix E-Lite LED Adore 10 W B22 CDL Ball LampL HLDERUEML8X007 685 Lumens 6500 k. Lamp Dimension (mm) Length102, Dia 56. Base Cap B22 HSN Code 8539. Make : Havells. or equivelent WIPRO/CG/Bajaj/Philips
supply & fix in repairs E-Lite LED curve with wide angle profile.High lumen batten with efficicency of 100 Lumens 9 w LED 6000k. Make : Havells. CAT E-LITE LED CURVE. CODE: LHEXBXP7PN1W09. HSN CODE 9405 or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix in repairs E-Lite LED curve with wide angle profile.High lumen batten with efficicency of 100 Lumens 20 w LED 6000k. Make : Havells. CAT E-LITE LED CURVE. CODE LHEXBXPNIN1W020. HSN CODE 9405 or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix in repairs E-Lite LED Adore 7 W B22 CDL Ball LampLHLDERUEML8X007 685 Lumens 6500 k. Lamp Dimension (mm) Length102, Dia 56. Base Cap B22 HSN Code 8539. Make : Havells. or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix in repairs E-Lite LED Adore 10 W B22 CDL Ball LampL HLDERUEML8X007 685 Lumens 6500 k. Lamp Dimension (mm) Length102, Dia 56. Base Cap B22 HSN Code 8539. Make : Havells. or equivelent WIPRO/CG/Bajaj/Philips
Supply and fix in repairs of 15 watts, 230 V LED light fitting for Building security with pressure die cast aluminum housing, with Control driver with efficiency 90 %,with heat resistant glass and IP 65 protection withSleek pressure die cast aluminum housing,Heat resistant glass with better optics for uniform distribution,including necessary fixing arrengment of clamps,nut,bolts, etc..including dismantling old unsv fittings all as specified and directed by Engr-in-Charge. Make : CG Cat Part No. LSTS -15-CDL or equivalent make of Philips/OSRM/KRIPA.
Supply and fix in repair MCB distribution board 415 Volts vertical TPN suitable for 4 Pole MCCB 125 Amps as incomer and MCB SP/TP as outgoings with IP 43 grade ingress protection, double door for surface / flush mounting with 200 Amps copper busbar for each phase and connecting up complete including taking down old DB and making good disturbed sufaces all as specified and as directed. Make : Indo Asian, Cat Ref No 811888 or Equivqlent in Legrand/Havells/ABB
Supply & fix in repair of MCCB 125 amps 4 pole 16 KA 415 volt complete including taking down all as specified & directed.
Supply & fix in repair of MCCB 100 amps TP 415 Volts, 16KA complete all as specified & directed.
Supply & fix in replacement of MCCB 63 amps TP 415 Volts, 16KA complete all as specified & directed.
Supply & fix in repair, sheet metal enclosure distribution box suitable for MCB'S 4 way TPN 415 volts with 200 Amps rated bus bar double door complete including connecting up all as specified and making good distrubed surface
All as per item No. 57 above but 8 way SPN with 200 Amps rated bus bar , 240 volts
All as per item No 57 above but 4 way SPN with 200 Amps rated bus bar , 240 volts
Supply & fix MCB Single pole, 240 volts 5 to 32 Amps 10 KA rupturing capacity, C series
Supply & fix MCB Single pole & neutral 240volts 5 to 32 Amps, 10KA rupturing capacity, C series
Supply & fix MCB triple pole & neutral 415 volts 5 to 63 Amps 10KA rupturing capacity, C series.
Supply & fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps
Taking down sub main wiring of any size complete all as specified and directed.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sq mm drawn through suitable size of non-metallic PVC rigid conduit with 4 sqmm copper conductor cable as earth conductor of same size and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed. Note :-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sq mm drawn through suitable size of non-metallic PVC rigid conduit with 6 sqmm copper conductor cable as earth conductor of same size and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed. Note :-Two run of cable and one run of earth continuity copper conductor and non metalic.
Material and labour for sub main wiring with Four single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sq mm drawn through suitable size of non-metallic PVC rigid conduit with 6 sqmm copper conductor cable as earth conductor of same size and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed. Note :-Four run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Material and labour for sub main wiring with Four single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 10 sq mm drawn through suitable size of non-metallic PVC rigid conduit with 10 sqmm copper conductor cable as earth conductor of same size and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed. Note :-Four run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Material and labour for replacing junction box/check box with plastic cover on roof/wall all as directed
Taking down ceiling fan of any size, type and make after disconnecting the electrical connections, cleaning, servicing , greasing removing and replacing all the unserviceable spare ,painting with two coats of synthetic enamel paint by means of suitable spray gun after cleaning and prepairing the suface including writing the MES No. ,fixing the same back to the original location all as directed
Taking down Exhaust fan of any size type and make after disconnecting the electrical connections ,cleaning, servicing , greasing removing and replacing all the unserviceable spare ,painting with two coats of synthetic enamel paint by means of suitable spray gun after cleaning and prepairing the suface including writing the MES No. ,fixing the same back to the original location all as directed. Note for item No. 70 & 71 : (i) All the replaced spare for unserviceable spares will be measured and paid separately (ii) The rate quoted shall be deemed to include the cost of minor spares such as split pin , screws washers etc.
Supply only ball bearing suitable for ceiling fans 1200 / 1400/ 1500 mm dia sweep.
Supply only ball bearing suitable for exhaust fans 300/450/600 mm dia sweep.
Supply only Capacitor 2.5 mfd for ceiling fans.
Supply only Capacitor 4 mfd for exhaust fans.
Supply only gun metal bush suitable for ceiling fans of 1200/1400/1500 mm sweep.
Supply only twin core flexible wire 1 Sqmm for connecting up ceiling fans, exhaust fans/wall mounting fan etc.
Supply only the mounting clamps and rubber bush with nut, bolt, washers, locking clip etc complete suitable for fixing at the down rod suitable for fixing the ceiling fan.
Supply and fix GI pipe down rod made out of 15 mm dia GI pipe suitably cut into service including necessary threading / cutting for necessary suitable modifications according to the requirement to fix downrod complete all as specified & directed.
Taking down old burnt out copper winding wire from ceiling fan of 1200/ 1400 mm sweep and rewiding by using same gauge of copper wire insulating and varnishing,heating, cleaning, servicing,greasing,refixing at site,testing for smooth functioning complete all as specified & directed.
Taking down old burnt out copper winding wire from exhaust fan of any sweep and rewinding by using the same gauge of copper wire super enameled including heating and varnishing,cleaning, servicing,greasing ,refixing at siteand testing for smooth functioning complete all as specified & directed.
Material and labour for Painting of ceiling fans with two coats of synthetic enamel paint by means of suitable spary gun after cleaning and prepairing the sufaces including writing the MES No. complete all as specified & directed.
Material and labour for Painting of exhaust fans with two coats of synthetic enamel paint after cleaning and prepairing the the suface including writing the MES No. complete all as specified & directed.
Supply and fix Modular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete.
Supply and fix Modular switch 2 way 6A, 1 module type, 230 volts, ISI marked complete.
Supply and fix Modular Bell push 6A 1 module type, 230 volts, ISI marked complete.
Supply and fix Modular stepped type electronic fan regulator 2 Module, on the existing phenolic laminated sheet etc. as reqd
Supply only Modular switch 1 way 16A, 1 module, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply only modular white cover plate with frame, 2 module ISI marked complete all as specified and as directed.
Supply only White cover plate with frame, 4 module ISI marked complete all as specified and as directed.
Supply and fix White cover plate with frame, 6 module ISI marked complete all as specified and as directed.
Supply only White cover plate with frame, 8 module ISI marked complete all as specified and as directed.
Supply & fix of common salt commercial all as directed by Engineer - in-Charge
Supply & fix of charcoal dust all as directed by Engineer - in-Charge
RRK PROJECTS
kamadhenu Electricals
s k enterprises
RAMESH BABU CO
SRI LAKSHMI CONSTRUCTIONS
CITIZEN ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .