Tender Value
₹31.6 L
EMD Value
₹63,140
Closing Date
24 Oct 2024, 6:00 pmClosed
GE(S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
SPL REPAIR/ REPLACEMENT OF OH LT LINE TO UG LT CABLE AND ALLIED WORKS AT ENGR REGT MT AREA AND TPT COY AREA UNDER GE(SOUTH) JAIPUR
2024_MES_673508_1
GE(S)/J-35P/2024-25 8907/E8
Open Tender
Civil Works
Item Rate
210 days
GE(S) Jaipur
Class D and Category b(i)
9 documents required · 9 mandatory
₹500
GE(S) Jaipur
₹63,140
Yes
30 Dec 2024
10 Sept 2024
31 Oct 2024
10 Sept 2024
24 Oct 2024
6 Oct 2024
Amount
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables errection of poles / struts/stays etc n.exe 10 Sqm on plan not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in any type of soil complete all as specified and as directed.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point complete all as specified and as directed.
M&L for laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified and as directed.
M & L Sand cushioning to PVC under ground cable with tibba sand and punning to provide a required cover complete all as specified and as directed. Note- Punned thickness of sand shall be measured and paid for sand used in cushioning to cable.
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade, of following sizes, complete all as specified and as directed. :-
185 sqmm, 3.5 core
95 sqmm, 3.5 core
50 sqmm, 3.5 core
25 sqmm, 4 core
16 sq mm, 4core
240 sq mm, 4core
Supply, fixing & install Steel tubular swaged pole complete with cast iron base plate size 300mmX300mmX6mm, finial taper plug, bolts, nuts & screws as specified for type 410 SP-31, 9.0 metres long complete all as specified. Note: The portion above coping shall be painted in alternative bands of Red & white colour starting with red colour (each band of 30 cm wide) by two coat of synthetic enameled paint upto 1.5 mtr height and numbering properly complete all as specified and as directed. Note- PCC for foundation and coping work shall be measured and paid separately.
M & L PCC (1:3:6) type C-2 using 40 mm graded stone aggregate for foundation of stay assembly / struts / poles etc. complete all as specified and as directed.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete all as specified and as directed.
Dismantling old existing road light any type, Supply and fixing of New Generation Energy Saving LED street light: indus-E Series top opening 90 watt. powder coated PDC aluminium housing with intgrated lens Polycarbonate cover,SMD LED with integrated lens cover,body with toughened glass, IP 66 protection complete all as specified and as directed.
Supply and fixing of GI pipe bracket 40mm dia medium grade,size 1.5 meter long, single swan neck shape suitable to fix on top of tubular pole complete with nuts, bolts and washers etc, including two coats of aluminium paint complete all as specified and as directed.
Supply and fixing of thermoplastic, polystyrene unbreakable junction box , size 217 x 253 x 115 mm suitable for pole mounted outdoor type IP 65 insulated complete with FI clamp & nut, bolts, washers and including phase seperator between R, Y, B terminals and one MCB SP 6 amp 10 KA, all duly mounted on din cannel, cable glands for cable entry complete all as specified and as directed.
S & F of 1100 volts grade heavy duty cable PVC insulated copper conductor cable three core with inner sheathing of PVC tape and overall PVC sheathed in service connection three core stranded copper conductor of size 1.5 Sqmm drawn through steel pole from junction box to street light fitting, complete all as specified and as directed.
Supply and laying in replacement GI pipe, size 40 mm dia medium grade fixed on poles, to walls and ceiling or laid in floor with all fittings for cable protection complete all as specified and as directed.
Supply and laying of GI pipe, size 80 mm dia medium grade fixed on poles, to walls and ceiling or laid in floors etc. with all fittings for cable protection complete all as specified and as directed.
Labour for boring under road/drain by manual/machine method for inserting GI tubing up to 80 mm dia for cable protection complete all as specified and as directed.
Dismantling of old existing pole of any type/size complete all as specified and as directed.
Dismantling old existing ACSR conductor of any type/size complete all as specified and as directed.
Dismantling old existing MS cross arms of any type/shape complete all as specified and as directed.
Dismantling old existing Insulators of any type/shape complete all as specified and as directed.
Supply and fixing of LT cable route indicator incl earth work /PCC work complete all as specified and as directed.
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover and testing complete all as specified and as directed. NOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-0, using 12.50 mm graded stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded stone aggregate with suitable MS handle. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire/strip. (iii) Quoted shall include cost of 7.5 metre earth lead wire/strip. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides
SHREE BHAGWATI ENTERPRISES (BID ID -3142495)
LAKSHMI ASSOCIATES (BID ID -3141265)
M/S Anil Enterprises (BID ID -3141629)
S.R.Enterprises (BID ID -3149225)
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3148957)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .