Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC 62A OFFICER COLONY AZAD NAGAR HISAR 125001 | HISAR | HARYANA | 125001 | ₹1.9 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹1.9 Cr+₹3.6 L (1.88%)Rejected-AOC | ₹1.9 Cr+₹3.6 L (1.88%) | L2 | Rejected-AOC HIGHEST |
| 3 | Rejected-Technical | - | - | Rejected-Technical RELATED PAPER NOT ATTACHED |
| 4 | Rejected-Technical 528 PREETI NAGAR 125001 | HISAR | HARYANA | 125001 | - | - | Rejected-Technical RELATED PAPER NOT ATTACHED |
Tender Value
₹1.8 Cr
EMD Value
₹3.7 L
Closing Date
15 Jul 2024, 5:00 pmClosed
SH SANDEEP KUMAR
Municipal Corporation Hisar
CONSTRUCTION OF 20 NOS OF BUS QUEUE SHELTERS AT VARIOUS LOCATION OF WARD NO. 1 TO 20 MC HISAR
2024_HRY_387312_1
202453FFD128 966A 411A B207 BC02F47B7477289ULB
Open Tender
Civil Works
Works
180 days
Hisar
2 documents required · 2 mandatory
₹15,000
Yes
₹3.7 L
Yes
31 Dec 2024
5 Jul 2024
16 Jul 2024
5 Jul 2024
15 Jul 2024
5 Jul 2024
Amount
P/F mefium grade MS Junction boxes in cast in situ fundation beam of 150x150 mm size
Providing and pasting at site high grade printed vinyl with bus shelter name logo, route number etc. on one sides of the front facia information board. The vinyl shall be minimum 85 micron thick, of LG or equivalent make complete in all respect and to the entire satisfaction of engineer-in-charge.
Supplying and fixing single sided aluminum frame signage made of 6063-T5 aluminum frame with section weight 3.80 to 4.00kg/m with minimum tensile strength 22000 psl as per drawing provided having 4mm clear solid compact polycarbonate in front and 3mm ACP sheet reinforced with internal support frame at rear completely sealed with the of silicon and EPDM to make it dust and water proof should have the inbuilt strong clipping and frame arrangement for holding the flex or digital imedia alongwith all necessary cleats and corner joinery required to build thus signage with sufficient strength. The aluminum frame should have strong locking arrangement which can resist theft. The aluminum frame should have polyester powder coating with minimum thickness of 60 micron. Signage should have inbullt arrangement of mounting it with the bus shelter structure. The enclosure should provide weather proof protection required for the signage to operate outdoors, having inbuilt ventilation systems.
Supplying and fixing of double sided aluminum frame signage made of 6063-T5 aluminum frame with section weight 5.3 to 5.5kg/m with minimum tensile strength 22000 psl as per drawing provided having 4mm clear solid compact polycarbonate on both side and reinforced with internal support frame, completely sealed with the help of silicon and EPDM to make it dust and water proof. Should have the inbuilt strong clipping and frame arrangement for holding the flex of digital media alongwith all necessary cleats and corner joinery required to build the signage with sufficient strength. The aluminum frame should have strong locking arrangement which can resist theft. The aluminum frame should have polyester powder coating with minimum thickness of 60 micron, signage should have inbuilt arrangement of mounting it with the bus shelter structure. The enclosure should provide weather proof protection required for the signage to operate outdoors, having inbuilt ventilation systems. (measurements for double sided signage to be taken for both sides during
Vandal resistant light source of polycarbonate body with compact fluorescent lamp of white NS colour of 55w of approved make with IP 67 approval, including cable fixing, switchgear etc. all complete.
Providing and fixing MS Electrical weather proof leader box approximately 600mm wide and 900mm high as required for installing MCB switch gear and meters as required for advertisement and other electrical gear, with provision for inserting cable conduits as per design. The access to feeder box shall be through a toll based (common for all locks. provided in each package) key. Tools should not be identical for different package shelters
Providing and fixing anodized aluminum 25 x 50mm channel frame with 40W standard manufactured tube light fittings with electronic choke starters and wiring all complete connection to electrical supply drom feeder box with minimum 4 tubelights x per square meter (of add panel size) or actual requirement decided by the engineer in charge. The tube light frame and fittings (including that in feeder pillar) should includeballast ELCB timer MCB mounting blocks etc. The tube light alignment should allow two way lighting (front and back) of add panel
Providing and fixing heavy duty SS prefabricated dust bins with canopy and two point support grouted in cement mortar and finished as per floor finish.
Providing and fixing 5-walled, 10mm thick polycarbonate multiwall sheet bronze colour having a light transmission of 37% with a U- value of 2.39 w/m2 K.Lexan thermoclear multiwall sheet LT2UV105R175 from SABIC innovative plastics or Equivalent. Fixing of the 10mm sheet to be done with profiles having EPDM / silicon. Aluminum profiles need to be used and front and rear of polycarbonate sheet has to be closed by aluminum profile.
Bidder Name
Amount
Shishpal Govt. Contractor (GSTN-06AKPPP4326H1ZX) BID ID -1117915
HIMALAYAN INFRACORP PRIVATE LIMITED (GSTN-06AACCH8826Q1ZY) BID ID -1118644
HIMALAYAN INFRACORP PRIVATE LIMITED
Shishpal Govt. Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .