Construction of Multipurpose Hostel cum Indoor Hall at Baripada Stadium at Mayurbhanj, Odisha under IOCL CSR.
NBCC/PMGSY-ZONE/ODISHA/IOCL-CSR/2020-21/39
NBCC/PMGSY-ZONE/ODISHA/IOCL-CSR/2020-21/39
Open Tender-Domestic
Civil Works General
Mayurbhanj, Odisha
₹11,800
Exempted
4 Mar 2021
18 Feb 2021
4 Mar 2021
4 Mar 2021
6 Mar 2021
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and
3 2.27 dressing complete. CUM 52.38 1,953.05 102,300.76
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level :1:2½:4:11 (1 ordinary portland cement : 2½ fly ash : 4 coarse
4 4.1.13 sand(zone-III) : 11 graded stone aggregate 40 mm nominal size) CUM 39.29 5,301.45 208,293.97
CENTERING AND SHUTTERING
Centering and shuttering including strutting, propping etc. and removal
5 5.9.1 of form for : Foundations, footings, bases of columns, etc. for mass concrete SQM 785.95 284.85 223,877.86
Centering and shuttering including strutting, propping etc. and removal
6 5.9.6 of form for : Columns, Pillars, Piers, Abutments, Posts and Struts SQM 1151.2 733.70 844,635.44
Centering and shuttering including strutting, propping etc. and removal
7 5.9.5 of form for : Lintels, beams, plinth beams, girders, bressumers and SQM 1520.47 552.05 839,375.46
Centering and shuttering including strutting, propping etc. and removal
8 5.9.3 of form for : Suspended floors, roofs, landings, balconies and access SQM 2810.5 693.05 1,947,817.03
RCC WORK BELOW PLINTH
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement
concrete for reinforced cement concrete work, using cement content as per approved design mix,
including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing
and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,
9 5.33.1 retard setting of concrete, improve workability without impairing strength and durability as per CUM 307.14 7,997.30 2,456,290.72
direction of Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per
design mix is payable/recoverable separately). All works upto plinth level
RCC WORK ABOVE PLINTH
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement
concrete for reinforced cement concrete work, using cement content as per approved design mix,
including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing
and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,
retard setting of concrete, improve workability without impairing strength and durability as per
direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.
Excess/ less cement used as per design mix is payable/recoverable separately).
Extra for providing richer mixes at all floor levels.
11 5.34 Note:- Excess/less cement over the specified cement content used is payable / recoverable separately.
Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered
REINFORCEMENT DETAILS
5.22B.1 Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from
factory/workshop to construction site including placing in position and binding all complete upto
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from
factory/workshop to construction site including placing in position and binding all complete above
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average
14 6.34.2 compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 CUM 466.09 7,280.70 3,393,461.46
cement : 6 coarse sand)
6 mm cement plaster of mix :
12 mm cement plaster of mix :
SL. NO. ITEM NO DESCRIPTION UNIT QUANTITY RATE AMOUNT
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make,
17 11.41.1 in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing SQM 1390.50 1,267.80 1,762,875.90
with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching
pigments etc., complete. Size of Tile 500x500 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with
water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours &
18 11.46 shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),
jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement &
matching pigments etc. complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm
(thickness to be specified by the manufacturer) of 1st quality conforming
to IS : 15622 of approved make in colours such as White, Ivory, Grey,
19 11.37 Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : SQM 163.18 926.90 151,251.54
4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including
pointing the joints with white cement and matching pigment etc.,
Providing and fixing Ist quality ceramic glazed wall tiles conforming to
IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in all colours, shades except burgundy, bottle green, black of
any size as approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of matching shade
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average)
thick cement mortar 1:3 (1 cement: 3 coarse sand) and
jointed with grey cement slurry mixed with pigment to match the shade of the
slabs, including rubbing and polishing complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and
jointed with grey cement slurry mixed with pigment to match the shade
22 11.26.1 of the slab, including rubbing and polishing complete with base of cement SQM 498.33 1,531.85 763,366.81
mortar 1 : 4 (1 cement : 4 coarse sand) :
White washing with lime to give an even shade :
23 13.37.1 New work (three or more coats) FOR EXTERIOR SQM 1560.44 28.55 44,550.56
Providing and applying white cement based putty of average thickness
24 13.8O 1 mm, of approved brand and manufacturer, over the plastered wall SQM 2231.43 115.15 256,949.16
surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :
New work (two or more coats) over and including water
thinnable priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade :
26 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming SQM 1560.44 164.70 257,004.47
coat of exterior primer applied @ 2.20 kg/10 sqm)
Two track two panels sliding window made of (small series)
frame 52 x 44 mm &sash 32 x 60 mm both having
27 9.147D.1 wall thickness of 1.9 ± 0.2 mm and single glazing bead of SQM 117.00 6,709.60 785,023.20
appropriate dimension. (Area of window upto 1.75 sqm)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought
28 9.1 framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold
fast lugs or dash fastener shall be paid for separately).
Providing and fixing ISI marked flush door shutters conforming to IS :
2202 (Part I) decorative type, core of block board construction with
frame of 1st class hard wood and well matched teak 3 ply veneering
29 9.20.2 with vertical grains or cross bands and face veneers on both faces of SQM 67.20 2,464.70 165,627.84
25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S.
Piano hinges IS : 3818 marked with necessary screws
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts,
nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3
coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc.
Providing and fixing bright finished brass door latch with necessary screws etc. complete :
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm
having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be
moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate
34 9.121 shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall RMT 105.60 679.85 71,792.16
be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and
approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin,
moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and
suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically
with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
SL. NO. ITEM NO DESCRIPTION UNIT QUANTITY RATE AMOUNT
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out
of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based
concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with
intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash
36 9.136 fastener of approved size and make, including applying a coat of approvedbrand fire resistant primer RMT 77.04 1,444.30 111,268.87
etc. complete as per direction of Engineer-in-charge. (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating
conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge,
with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide,
bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly
filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of
approved make, including applying a coat of approved fire resistant primer etc. all complete as per
direction of Engineer-in-charge (panneling to be paid for separately).
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on
back side of the Panic Latch of reputed rand and manufacture to be approved by the Engineer- in-
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc.,
with G.I. beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120
gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I.
39 9.138.1 beading etc., complete all as per direction of Engineer-in-charge. SQM 2.40 36,050.45 86,521.08
With clear fire resistant glass panes 6 mm thick of approved brand, having minimum 60 minutes fire
Providing and fixing in position collapsible steel shutters with vertical
channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm
size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia
steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
handles, including applying a priming coat of approved steel primer. or by any other accreditation
body which operates in accordance
with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for
testing and calibration scopes shall be eligible. The maximum
glazing size shall not be more than 1100x2200 mm (w x h) or 2.42
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer using structural steel etc. as required. In gratings,
frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting
the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary
accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the
floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc.).
Trenching in ordinary soil up to a depth of 60 cm including removal and
stacking of serviceable materials and then disposing of surplus soil, by
spreading and neatly levelling within a lead of 50 m and making up the
43 2.1 trenched area to proper levels by filling with earth or earth mixed with CUM 45.53 68.70 3,127.91
sludge or / and manure before and after flooding trench with water (excluding
cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage
44 2.2 upto 5 km lead complete (earth measured in stacks will be reduced by CUM 45.53 469.50 21,376.34
20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5
45 2.3 km lead complete (sludge measured in stacks will be reduced by 8% for CUM 45.53 276.90 12,607.26
Supplying and stacking at site dump manure from approved source,
46 2.4.1 including carriage upto 5 km lead complete (manure measured in stacks CUM 45.53 229.95 10,469.62
will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm
Supplying, filling, spreading & leveling gravels of size range 5 mm to
10 mm, in the recharge pit, over the existing layer of boulders, in
47 2.6 required thickness, for all leads & lifts, all complete as per direction SQM 91.05 4.30 391.52
of Engineer-in-charge.
Spreading of sludge, dump manure and/or good earth in required thickness
48 2.8 as per direction of officer-in-charge (cost of sludge, dump manure and/ or CUM 45.53 46.15 2,101.21
good earth to be paid separately).
Grassing with selection No. 1/ Doob grass including watering and
maintenance of the lawn for 30 days or more till the grass forms a thick
lawn, free from weeds and fit for mowing including supplying good earth, if
needed (the grass and good earth shall be paid for separately).
TREE In rows 5 cm apart in both directions
50 i Ficus tree PCS 3 500.00 1,500.00
51 ii Sago palm PCS 3 500.00 1,500.00
52 v Royal Palm PCS 3 500.00 1,500.00
Total 55,989.68
TOTAL of CIVIL WORK 28,755,633.02
SANITARY INSTALLATIONS
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P
or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled
1 17.1 device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting
and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Each
SL. NO. ITEM NO DESCRIPTION UNIT QUANTITY RATE AMOUNT
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with
seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually
2 17.2 (P- 287) controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete,
including cutting and making good the walls and floors wherever required :
a) 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid Each 8 5,260.95 42,087.60
Providing and fixing white vitreous china flat back half stall urinal ofsize 580x380x350 mm with white
PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions
and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other
couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors
wherever required :
a) 17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern Each 8 9,360.60 74,884.80
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass
4 17.7 (P- 288) waste of standard pattern, including painting of fittings and brackets, cutting and making good the
walls wherever require :
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Each
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for
5 17.8 (P- 289) the reception of pipes and fittings. -
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets
6 17.10 (P- 289) and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the -
walls wherever required :
Kitchen sink with drain board
Providing and fixing mirror of superior glass (of approved quality) andof required shape and size with
7 17.32 (P- 291) plastic moulded frame of approved make and shade with 6 mm thick hard board backing : -
a) 17.32.4 Rectangular shape 1500x450 mm each 2 1,786.55 3,573.10
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised Each
8 17.33 (P- 291) aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long 2 841.80 1,683.60
screws, rawl plugs etc., complete.
Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun)
iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded
9 17.61 (P- 296) stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 -
(1 cement : 4 coarse sand) :
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes
by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including
10 12.43 (P- 209) cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the
wall etc. complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592
11 12.41 (P-209) Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal
expansion, (i) Single socketed pipes.
12.41.2 110 mm dia UPVC rain water pipe Mtr 180 305.05 54,909.00
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised
12 12.42 (P-209) Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
b 12.42.5.2 110 mm dia UPVC rain water pipe bend Each 60 129.85 7,791.00
c 12.42.6 Shoe (Plain)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and Each
13 12.44 (P-210) weighing not less than 440 grams. 60 47.25 2,835.00
Providing and fixing on wall face UV stabilized Unplasticised Rigid PVC pipes (single socketed) having
14 N.SOR 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
Supplying all materials, labour, T&P and construction of platform for counter top basin with brick
15 N. SOR masonary wall using 1st class K.B. brick having crossing strength not less than 75 Kg/Cm in C.M (1:4)
R.C.C (1:1 1/2:3) slab of following size using 20mm & down size graded H.G. chips with oval shape
basin hole including
1500x600 cladding
granite platform thetwo
as edge of the slab with granite plate including supplying, Each
Providing and fixing 20mm & above thick white marble partition plate of following size for urinals
16 N. SOR including cost, conveyance and taxes for all materials, labours, T&P etc. including cutting to size and
moulding complete as directed by the Engineer-in-charge.
Size in mm (900x600 topx450 bottom) Each
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories
having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal
ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
b) Access door cap - 110 mm Each 112 72.62 8,133.44
c) "P" trap 110mmx110mm long Each 92.00 293.60 27,011.20
d) Multi floor trap 110 Each 64.00 223.90 14,329.60
e) 110mm double tee with doon Each 22.00 431.30 9,488.60
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories
having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal
18 Non sor ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
SL. NO. ITEM NO DESCRIPTION UNIT QUANTITY RATE AMOUNT
a) Non sor Coupler - 110 mm Each 21.00 135.25 2,840.25
b) Non sor Single tee with door - 110x110x110 mm Each 119.00 276.00 32,844.00
C) Non sor 110 mm bend Door Each 76.00 205.70 15,633.20
d) Non sor 110 mm plain bend Each 46.00 139.00 6,394.00
B. WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &
cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same including testing of joints complete as per direction
of Engineer in Charge.
15 mm nominal outer dia .Pipes. Mtr
20 mm nominal outer dia .Pipes. Mtr
25 mm nominal outer dia .Pipes. Mtr
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &
cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with
20 18.7 (P- 319) clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement
and testing of joints complete as per direction of Engineer in Charge.
25 mm nominal outer dia .Pipes. Mtr
32 mm nominal outer dia .Pipes. Mtr
50 mm nominal outer dia .Pipes. Mtr
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &
cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes &
21 18.9 (P- 319) fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per
direction of Engineer in Charge.
75 mm nominal outer dia .Pipes. Mtr
100mm nominal inner dia pipes Mtr
Providing and fixing C.P. brass angle valve for basin mixer and geyser
15mm nominal bore Each
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore Each
32 mm nominal bore. Each
50mm dia nominal bore Each
80 mm dia nominal bore Each
Cutting holes upto 30x30 cm in walls including making good the same :
With common burnt clay F.P.S. (non modular) bricks Each
Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole
after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) including finishing complete so as to make it leak proof.
Constructing masonry Chamber 60x60x75 cm inside, in brick workin cement mortar 1:4 (1 cement: 4
coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and
180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4 graded
stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement
: 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement
mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement
complete as per standard design :
a) 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 4 9,288.40 37,153.60
SL. NO. ITEM NO DESCRIPTION UNIT QUANTITY RATE AMOUNT
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement:
4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter
and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4
27 18.34 (P- 325) graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1
cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with
cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement
complete as per standard design :
a) 18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 2 16,134.15 32,268.30
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to
IS:8931 including C.P. brass extension if required: (JAQUAR/MARK/EQUIVALENT)
a) N SOR 15mm dia C.P.Pillor cock Each 16 1,064.70 17,035.20
b) N SOR 15mmm C.P.Urinal flush cock Each 16 2,205.02 35,280.34
c) N SOR 15mm dia C.P. flange Each 32 64.97 2,079.17
d) N SOR 15mm dia C.P. extension piece Each 32 146.87 4,699.97
e) N SOR C.P. towel ring Each 12 1,327.00 15,924.01
g) N SOR Overhead shower with arm and telific sower Each 12 4,368.00 52,416.00
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and
29 N SOR weighing not less than 690 gms.
a) N SOR Two way bib cock (800gms) with health facet Each 12 1,404.09 16,849.09
b) NSOR Bottle trap set with extension pipes Each 12 2,055.74 24,668.90
) NSOR Toilet paper holder Each 12 1,352.00 16,224.00
e) NSOR Towel rail (600mm long x 20mm dia) Each 12 1,478.74 17,744.84
15 NSOR Providing and fixing stainless steel drain jali of approved make/quality. Each 12 79.94 959.24
C. EXTERNAL WATER SUPPLY
Design, Construction, Testing & Commissioning of following capacity R.C.C under ground clean water
30 N SOR reservoir including provision of G.I ladder, C.I manhole (with locking arrangement) ventilator,
50000 litor for domestic water sump 1 no
Supply, installation, testing & commissioning of centrifugal pump sets would provide head & discharge
of 45 mt & 9 LPS respectively including control panel, section and delivery piping & valve arrangement
etc. all complete as the direction of E.I.C ( @ 5 H.P per set) with 100% Stand by for drinking water
D. EXTERNAL SEWERAGE
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top
slab with 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal
size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with
floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand :
4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as
per standard design :
a) 19.7.3.2 With Sewer bricks conforming to IS : 4885 Each 3 28,657.15 85,971.45
33 19.8 (P- 351) Extra for depth for manholes :
a) 19.8.2.2 With Sewer bricks conforming to IS : 4885 Mtr 3.00 9,031.30 27,093.90
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top
slab with 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),
19.7.1.2 With Sewer bricks conforming to IS : 4885 Each 3 10,915.65 32,746.95
Extra for depth for manholes :
With Sewer bricks conforming to IS : 4885
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff
36 19.6 (P- 350) mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete :
a) 19.6.2 150 mm dia. R.C.C. pipe metre Mtr 120 462.60 55,512.00
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40
37 19.2 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
a) 19.2.2 150 mm diameter S.W. pipe Mtr 98 999.15 97,916.70
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry
38 19.4 chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be
not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
a) 19.4.2.2 With sewer bricks conforming to IS : 4885 Each 6 2,321.45 13,928.70
Supply, instalation, testing, commissioning of sewarage treatment plant of 10KLD capacity . The Each
cost includes all civil, mechanical, electrical works, inlet , out let tanks etc complete in all
39 N SOR respect as per direction of EIC. 1.00 600,000.00 600,000.00
D. TUBE WELL & RAIN WATER HARVESTING
SOR ITEMS (BORING)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS:
2800 (part I), including collecting samples from different strata, preparing and submitting strata
chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries
required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below
23.1 All type of Soil
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium
41 23.3 well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour
charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -incharge.
SL. NO. ITEM NO DESCRIPTION UNIT QUANTITY RATE AMOUNT
23.3.3 200 mm nominal size dia Mtr 30 1,066.05 31,981.50
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium
42 23.4 well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings &
accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
23.4.3 200 mm nominal size dia Mtr 10 1,135.80 11,358.00
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in
43 23.5 the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. CUM 10.00 1,326.55 13,265.50
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over
44 23.6 the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of CUM 8 1,326.55 10,612.40
Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in
45 23.7 required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer - CUM 10 1,326.55 13,265.50
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff
46 19.6 mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete :
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40
47 19.3 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
19.3.5 300 mm diameter S.W. pipe Mtr 66 993.65 65,580.90
Supplying all materials, labour, T&P & Construction of Desilting chamber of inside size 2.0x1.4x1.2 mtr Each
for Rain Water Harvesting including earth work in hard soil, PCC (1:3:6) 25mm thick brick work in
48 NSOR C.M. (1:6) inside & outside C.P. with C.M. (1:4) AS flooring, RCC cover slab of 125mm thick manholes & 1.00 21,404.19 21,404.19
C.I. M.H. cover of size 500X500mm light duty as per the drawing & specification & direction of E.I.C.
Supplying all materials, labour, T&P & Construction of Filter bed of inside size 5.0x2.5x2.0mt with inlet Each
& out chamber for Rain Water Harvesting including earth work in hard soil, PCC (1:3:6), 25mm thick
49 NSOR brick work in C.M (1:4) AS flooring RCC cover slab of 125mm thick with Manholes & C.I.M.H. cover of 1.00 64237.41 64,237.41
size 500x500 light duty as per the drawing & specification & direction of the E.I.C.
Supplying all materials, labour, T&P of 3 Phase, 50 cycle submersible pump set suitable for 200mm dia Each
50 N SOR tube well with a head of 45.00 mtrs. & discharge 2lps including 100% Stand by testing and 2.00 28980.00 57,960.00
commissioning of the pump sets -2 No.(Make - KSB/TEXMO/KBL/EQUIVALENT)
Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length
Providing and fixing ball valve (brass) of approved quality, High or low
52 18.18.2 pressure, with plastic floats complete : each 25 386.40 9,660.00
20 mm nominal bore
Providing and fixing C.I. dirt box strainer for bulk type water meter
with nuts, bolts, rubber insertions etc. complete conforming to
Providing and fixing gun metal non- return valve of approved quality
(screwed end) :
50 mm nominal bore
58 17.29 Providing and fixing 100 mm sand cast Iron grating for gully trap each 16 44.60 713.60
Providing and fixing enclosed type water meter (bulk type) conforming
to IS : 2373 and tested by Municipal Board complete with bolts,
60 18.60.1 nuts, rubber insertions etc. (The tail pieces if required will be paid each 1 3,576.10 3,576.10
80 mm dia nominal bore
Providing flanged joints to double flanged C.I./ D.I. pipes and specials,including testing of joints :
62 18.30.1 80 mm diameter pipe each 28 169.15 4,736.20
64 19.1.4 Providing & Laying & Jointing Glass Stone ware Pipes….. Etc(Ref:-19.1, Page No:-349)
68 19.2.4 Providing & Laying Cement Concrete(1:5:10) all round S.W Pipe Including Bed(Ref:-192,(P-349)
Providing, laying and jointing glazed stoneware pipes class SP-1 with
stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 finesand) including testing of
joints etc. complete :
150 mm diameter
TOTAL of SANITARY & PHE WORK 4,941,820.03
1 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated
2 1.3.1 copperAconductor single core cable in surface / recessed steel conduit, with modular switch, modular
1.4 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core
3 cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and point 8 10,320.00
earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as
required. 1,290.00
1.54 Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point
with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable
6 in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor Meter 450 119,250.00
single core cable for loop earthing as required. 265.00
1.6 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable
7 in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor Meter 40 15,680.00
single core cable for loop earthing as required. 392.00
1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
8 copper conductor, single core cable in surface/ recessed steel conduit as required
SL. NO. ITEM NO DESCRIPTION UNIT QUANTITY RATE AMOUNT
10 1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Meter 30 356.00 10,680.00
12 1.7.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire Meter 180 529.00 95,220.00
13 1.7.10 4 x 10 sqmm + 2 x 6 sqmm earth wire Meter 180 670.00 120,600.00
1.2 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess
15 including painting in case of surface conduit, or cutting the wall and making good the same in case of
recessed conduit as required.
1.18 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,
19 unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC
22 conduit as required.
b Fitting & Accessories
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate
switch box including connections but excluding modular plate etc. as required. 342.00
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,
26 including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,
1.32 connection etc.fixing
Supplying and as required.
suitable size GI box with modular plate and cover in front on surface or in recess,
27 including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular
1.27 switch, connection
Supplying and fixingetc. as required.
following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.
30 1 or 2 Module (75mmX75mm) Each 40 9,720.00
31 3 Module (100mmX75mm) Each 60 16,020.00
34 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
35 1.24.1 including
5/6 A switchconnections but excluding modular plate etc. as required. Each 20 85.00 1,700.00
36 1.24.4 3 pin 5/6 A socket outlet Each 20 111.00 2,220.00
37 1.24.6 Telephone socket outlet Each 4 119.00 476.00
38 MR CAT 6 LAN socket outlet Each 20 584.00 11,680.00
39 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including Each 60 65.00 3,900.00
40 MR connection
Supplying and etc fixing
ding dong call bell suitable for single phase, 230 volts complete as required. Each 2 191.00 382.00
41 1.34 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding Each 10 32.00 320.00
42 MR modular plate
Supplying andas required.
fixing brass batten/ angle holder including connection etc. as required. Each 5 117.00 585.00
43 MR Supplying, Installation, testing and commissioning of 20 watt LED tube light single fitting (4 feet) with Each 120 1,502.00 180,240.00
44 MR CRCA channel suitable
Supplying, Installation, testingfor 230andV, 50 Hz etc. as reqd.
commissioning (Make:
of 12 Wipro / type
watt surface Philips/
LEDHavells/Halonix)
downlight fitting suitable Each 40 1,571.00 62,840.00
Supplying, Hz etc. astesting
Installation, reqd. and
(Make: Wipro / Philips/
commissioning Havells/Halonix)
of 12 watt recess type LED downlight fitting suitable Each 10 1,490.00 14,900.00
Supplying, Hz etc. astesting
Installation, reqd. and
(Make: Wipro / Philips/
commissioning Havells/Halonix)
of 15 to18 watt surface type LED downlight fitting Each 30 2,390.00 71,700.00
47 MR suitable for Installation,
Supplying, 230 V, 50 Hz etc. as
testing andreqd. (Make: Wipro
commissioning / Philips/
of 18 Havells/Halonix)
watt recess type LED downlight fitting suitable Each 5 2,390.00 11,950.00
Supplying, Hz etc. astesting
Installation, reqd. and
(Make: Wipro / Philips/
commissioning Havells/Halonix)
of 32-36 watt, 2'x2' surface type LED fitting suitable Each 25 6,290.00 157,250.00
Supplying, Hz etc. astesting
Installation, reqd. and
(Make: Wipro / Philips/
commissioning Havells/Halonix)
of 32-36 watt, 2'x2' recess type LED fitting suitable Each 5 5,890.00 29,450.00
Supplying andHz etc. of
surface / Philips/
mounted LEDHavells/Halonix)
fitting for wash basin mirror complete with all Each 10 1,224.00 12,240.00
51 MR accessories
Supplying andetcfixing
as reqd. (Make:
7-9 watt LEDWipro
Havells/Halonix)
brass batten holder operating on 230 volt, 50 Hz, each 6 134.00 804.00
52 MR AC supply etc. as required. (Make: Wipro / Philips/ Havells/Halonix)
Supplying and fixing of 9-12 watt LED Bulk head fitting IP-65/66 with all accessories etc. as required. each 16 1,667.00 26,672.00
53 MR (Make: Wipro
Supplying and/ Philips/
fixing ofHavells/Halonix)
45 watt LED Compound light fitting made up of Aluminium housing with each 10 8,100.00 81,000.00
54 MR toughned
of 1200 mm and IP-65ceiling
sweep protection i/c allrating
fan (BEE accessories
5 Star),and fixing wiring
including in the existing
the downbracket
rods ofetc. as
standard Each 56 2,155.00 120,680.00
55 MR lengthof(upto
SITC 140030mm cm)sweep
ceiling fan,FRLS PVC wiring
including insulated
down rodsconductor singlelength
of standard core cable
(upto 30etc cm)
56 MR with 1.5 sqmm
Supplying, FRLS PVC
Installation, insulated
testing copper conductor
and commissioning single
walletc as required.
mounting (Make: on
fan operating Each 5 1,850.00 9,250.00
Supplying, AC supplytesting
Installation, completeandwith connection etc.
commissioning as required.
of 250 mm sweep (Make:
PVC CG/Usha/Bajaj/
fresh air exhaust fan i/c Each 10 1,801.00 18,010.00
58 MR shutter complete
Supplying, with connection
installation of 300 mm etc.sweep as required.
heavy duty (Make:
metallicCG/Usha/Orient/
body exhaust fan Khaitan/Halonix)
with safe guard / louver Each 32 3,546.00 113,472.00
59 MR shutterofinsplit
unit of 1.5including
Ton (3 making the hole
Star Rated) bothtooutdoor
suit the compressor
size of the above fan, indoor
unit and making good Each 8 42,500.00 340,000.00
60 MR cooling unit inside rooms with necessary accessories such
SITC of split type AC unit of 2.0 Ton (3 Star Rated) both outdoor compressor unitas brass flare nut, screwandPVC and other
indoor Each 71,928.00 -
61 MR cooling
SITC of unit insidetype
cassette rooms AC with
of 2.0 Ton accessories
(3 Star Rated) forboth
outdoori/c Factory Fabricated
compressor Bracket
unit and indoor Each 86,500.00 -
62 MR cooling unit
S.I.T.C. inside rooms
of following withwall
capacity necessary
mounting accessories
automatic for installation
voltage i/c Factory
stabilizer dual step Fabricated
completeBracket
4 KVAhigh/ low voltage cut off, voltmeter for output voltage, power on indication, 15/16A 3 pin plug Each 4,135.00 -
65 MR Supplying and fixing Suitable size copper tube (both supply and return pipes) for outdoor units to Mtr. 15 943.00 14,145.00
66 MR indoor unitsand
Supplying complete withdia
fixing 3/4" nitryle insulation
braided etc as
PVC pipe required.
from indoor unit to the outside of the building for Mtr. 15 90.00 1,350.00
draining out discharged water i/c making good the damages etc complete as required. Total 1,529,205.00
c Distribution Board
67 2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB
68 2.5.1 distribution
4 way (4 + 12),board of sheet
Double doorsteel, dust protected, duly powder painted, inclusive of 200 A tinned copper Each 4 5,651.00 22,604.00
70 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution
way (4+12) on surface/
Double door recess, complete with tinned copper bus bar, neutral bus bar, earth bar, Each 4 3,068.00 12,272.00
73 2.4.3 8 way (4+24) Double door Each 4,601.00 -
74 2.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" series, miniature circuit breaker
75 2.10.1 suitablepole
Single for lighting and other load of following poles in the existing MCB DB complete with Each 90 199.00 17,910.00
76 2.10.5 Triple pole and neutral Each 4 1,092.00 4,368.00
77 4 Supplying and fixing following rating 230/415 volt, "C" curves, miniature circuit breaker suitable for
78 MR lighting
TPother load of following poles in the existing MCB DB complete with connections, testing Each 6 2,450.00 14,700.00
82 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve Each 12 848.00 10,176.00
83 MR DP MCB complete
Supplying with connections,
& fixing suitable size GI boxtesting and commissioning
with modular etc. in
plate and cover asfront
on surface or in recess each 12 1,468.00 17,616.00
including providing and fixing 25 A modular socket outlet and 25 A modular Motor Starter including Total 189,262.00
84 d Earthing
85 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing Set 4 6,216.00 24,864.00
86 5.5 masonry with
Earthing enclosure
copperwith cover
plate 600having
600 mmarrangement
X 3 mm thickand watering
including pipe of 2.7 and
accessories, metre long
providing Set 6 10,724.00 64,344.00
87 5.11 masonry
Providingenclosure
and fixingwith cover
25 mm X 5plate
mm having locking
G.I. strip in 40 arrangement
mm dia G.I. pipeandfrom
earthpipe of 2.7 including
electrode metre long Meter 30 483.00 14,490.00
88 5.15 connectionand
Providing withfixing
X spring, washer
5 mm G.I. strip excavation
or inre-filling
recess foretc.connections
as required.etc. as required. Meter 30 206.00 6,180.00
89 5.1 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including Meter 40 1,224.00 48,960.00
90 5.14 connectionand
Providing withfixing
X 5 spring, washer
mm copper excavation
strip on surfaceand re-filling
or in recessetc. as required. etc. as
for connections Meter 200 1,009.00 201,800.00
5.16 required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess
for loop earthing as required. 57.00
SL. NO. ITEM NO DESCRIPTION UNIT QUANTITY RATE AMOUNT
92 e Lightening Conductor
93 6.2 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having Each 10 448.00 4,480.00
94 6.3 single prong
Jointing copperat top,
dia 6 mm thick G.I.
copper/ G I base
base including holes
of the finial etc.other
or any complete as object)
metallic Each 40 93.00 3,720.00
95 6.7 by rivetingand
Providing / nutfixing
tape 20 mm and Xsoldering etc on
3 mm thick as parapet
required.or surface of wall for lightning conductor Meter 120 104.00 12,480.00
96 6.8 complete as
Providing andrequired.(For
fixing G.I. tape horizontal
X 3 mm thick on parapet or surface of wall for lightning conductor Meter 80 163.00 13,040.00
97 6.12 complete as
Providing andrequired.(For
fixing testingvertical run) of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of
joint, made Each 8 102.00 816.00
98 6.14 G.I. bolts, and
Providing nuts,laying
chuckG.I.nuts and32spring
tape mm Xwashers etc. earth
6 mm from complete as required.
electrode directly in ground as required. Meter 30 176.00 5,280.00
Total 39,816.00
99 f-1 CCTV, PAS, FAS Conduits
100 1.2 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess
101 1.20.1 including
20 mm painting in case of surface conduit, or cutting the wall and making good the same in case of Meter 250 146.00 36,500.00
Total 81,680.00
g Panels & Cabling
1 Supplying of PVC insulated and PVC sheathed/ XLPE armoured power cable of 1.1 KV grade
confirming to IS:7098 Part-I of following size. as required.(Make: KEI / RR Kabel /Havells/POLYCAB)
110 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
111 7.1.2 following
Above 35size direct
sq. mm andin upto
sq. mm excavation, sand cushioning, protective covering and refilling Mtr 20 338.00 6,760.00
112 7.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
113 7.2.2 grade of
Above 35following size upto
sq. mm and direct95insq.
mm in the same trench in one tier horizontal formation including Mtr 20 236.00 4,720.00
114 7.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of
115 7.5.2 following
Above 35size in the
sq. mm existing
HUME / METAL pipe as required. Mtr 30 47.00 1,410.00
116 7.6 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
117 7.6.1 following
35 sq. mmin the existing masonry open duct as required. Mtr 30 23.00 690.00
118 7.6.2 Above 35 sq. mm and upto 95 sq. mm Mtr 25 38.00 950.00
119 7.6.3 Above 95 sq. mm and upto 185 sq. mm Mtr 15 52.00 780.00
120 7.7 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV
mm size on wall surface as required. Mtr 40 39.00 1,560.00
122 7.7.2 Above 35 sq. mm and upto 95 sq. mm Mtr 30 104.00 3,120.00
123 7.7.3 Above 95 sq. mm and upto 185 sq. mm Mtr 20 122.00 2,440.00
9 Supplying and making end termination with brass compression
124 gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
125 9.1.27 grade as sq.mm
3.5 x185 required.
130 14.13 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings
131 14.13.1 including
50 mm diatrenching (75 cm deep)and re-filling etc as required Mtr 20 536.00 10,720.00
133 MR Supplying and fixing 32 mm dia GI pipe (Medium class) of length suitable for mounting street light each 10 680.00 6,800.00
fitting on parapet/ wall with clamp etc complete as required. Total 103,386.00
SL. NO. ITEM NO DESCRIPTION UNIT QUANTITY RATE AMOUNT
145 1 Passenger Lift
Supplying, Installation, Testing and Commissioning of 7/13passengerMachine room less type lift
havingPassenger
Type: contract speed
Lift of 1.00 MPS serving different floors in the lift shaft as per detailed specifications
i)Speed:1.00 Mtrs./ Sec
ii)Floor served: G + 3
iii)Travel: 10 Mtr (appx.)
iv)Stops & opening: 4
v)Controller: AC variable voltage & variable frequency
vi)ARD: Automatic rescue device complete with dry maintenance free batteries as required.
vii) Operation: Microprocessor based single automatic push button/simplex selective colllective with or
without attendant.
viii)Power-415 volt,3 phase,50 HZ,4 wire system
ix)Type of doors
a)Car : Automatic power operated,centre opening horizontal sliding stainless steel scratch proof
b) Landing doors: rockS.S.
door with scratch proof surface(moon rock finish)
Car inside about 1100 mm x 2000 mm
Car Entrance:Clear Opening 900 mm x 2000 mm high protected with car door
Lift Well size:2550mmX1900mm
Car Ceiling &steel scratch
Lighting: LEDproof surface.
lighting (Moon suspended
concealed rock finish) false ceiling with plain arcylic diffuser.The
Car of suspended
Ventilation: false fan
Pressure ceiling
withshall be powder
anodised coated
aluminium aluminium.
Emergency lighting in car: Battery operated emergency lighting in the lift car.
Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room
Emergency Alarm: Battery operated alarm bell system in lift car and control room
Position of Machine Room: Directly above the lift shaft
Electric power supply: AC 415 Volt 3phase, 50 Hz, terminated in machine room.
Fireman switch: Fireman switch at main landing terminal.
Voice annoucement system in the car to announce the position of the elevator in the hoistway as the
Fully loadedorwithstops at afloor
overload served by the elevator.
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the
hand rail not elevator
less thanin600mm
the hoist wayatas
passes or stops
level to a floor
fixedserved by the
adjacent elevator.
to control panel
the lift system:
car. Digital display of direction, floor location both inside the car and on landing floor.
EXTERNAL Electrical
146 1 Supplying of PVC insulated and PVC sheathed/ XLPE armoured power cable of 1.1 KV grade
147 a confirming
x300 sq.mm Part-I of following size. as required.(Make: KEI / RR Kabel /Havells)
150 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
151 7.1.4 following 185
a)Above sizesq.
uptoincluding excavation, sand cushioning, protective covering and refilling
152 7.1.3 b)Above 95 sq. mm and upto 185 sq. mm Mtr 10 352.00 3,520.00
7.7 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on wall surface as required.
154 7.7.3 Above 95 sq. mm and upto 185 sq. mm (clamped with Mtr 30 182.00 5,460.00
25/40x3mm MS flat clamp)
155 7.7.4 Above 185 sq. mm and upto 400 sq. mm (clamped with Mtr 20 122.00 2,440.00
number PVC insulated and PVC sheathed / XLPE
156 power cable of 1.1 KV grade of following size in the existing Mtr -
RCC/ HUME/ METAL pipe as required.
157 7.5.2 Above 35 sq. mm and upto 95 sq. mm Mtr 20 47.00 940.00
158 7.5.3 Above 95 sq. mm and upto 185 sq. mm Mtr 20 64.00 1,280.00
159 7.5.4 Above 185 sq. mm and upto 400 sq. mm Mtr 40 112.00 4,480.00
160 7.6 Laying of one number PVC insulated and PVC sheathed / XLPE -
35 sq.ofmm1.1 and
KV grade of sq.
upto 95 following size in
mm Metre 38the existing Mtr 10 38.00 380.00
162 7.6.3 Above 95 sq. mm and upto 185 sq. mm Metre 52 Mtr 10 52.00 520.00
163 7.6.4 Above 185 sq. mm and upto 400 sq. mm Metre 96 Mtr 10 96.00 960.00
164 9.1 Supplying and making end termination with brass compression gland & aluminium lugs for following -
3½ Xof300PVCsq.insulated
mm (70mm) & PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as reqd. each 4 936.00 3,744.00
168 14.13 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings
169 14.13.4 including
150 trenching (75 cm deep)and re-filling etc as required
172 MR S/I/T/C of outdoor type double door front and back openable CPRI approved feeder pillars ( IP-54) floor sq.mtr. 10 28,000.00 280,000.00
173 MR mounted free
Providing and standing, comprising
fixing following compartmentalised
accessories in the existingcubical
feederenclosed dust &
piller including - -
174 MR drilling
A/315A, , making
36 kA,connections,
MCCB with earthing etc. Complete
rotary handle & spreaderaslink
per directions of the Engineer-in-charge each 3 27,643.00 82,929.00
175 MR 250A, 4P, 36 kA, MCCB with rotary handle & spreader link each 2 22,560.00 45,120.00
176 MR 200 A, 4P, 35 kA, MCCB with rotary handle & spreader link each 2 19,947.00 39,894.00
177 MR 100 A, 4P, 25 kA, MCCB with rotary handle & spreader link each 4 9,138.00 36,552.00
178 MR 63A, 4P, 25 kA, MCCB with rotary handle & spreader link each 4 6,000.00 24,000.00
179 MR LED pilot indicating lamp with transformer each 11 350.00 3,850.00
181 MR 0-500V, Ampere meter each 8 500.00 4,000.00
182 MR Volt meter/Ammeter selector switch each 11 100.00 1,100.00
TOTAL of E & M WORK 5,410,751.00
Total Cost of Work 39,108,204.05
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-39.pdf
Tender Document
BOQ_39.pdf
Tender Document
INTEGRITY PACT_39.pdf
Tender Document
APPROVED_MAKES_39.pdf
Tender Document
Drawings_39.pdf
Tender Document
GCCContracting2019withAmendment1to3.pdf
Tender Document
Instruction for_Online_Bid_Submission.PDF
Tender Document
Physical Milestone.PDF
Tender Document
corrigendum-9-Corrigendum_02_Nit_39.pdf
pdf • 0.13 MB
addendum-6e566cefd600-Corrigendum_01_Nit_39.pdf
pdf • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .