RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate Door Frame Metal Detector Dfmd Security Metal Detector ( 33 ) ( Under PAC ) Make garrettusa Model garrettpd6500idfmd Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TYPE/CAPACITY Type of usage Outdoor Indoor
RequiredOutdoor Detection Zones Multiple Zone Single Zone
RequiredMultiple 1/7 Zone Function Detects Ferrous
RequiredNon- Ferrous and alloy metals concealed in the body of a person when passsed through the arch way * Number of Horizontal Detection Zones covering full Height 16 Single Zone
Required8
Required10
Required12
Required14
Required16 Capacity/throughput rate (person/min) 30 or more * False Alarm rate (%) 2 * DIMENSIONS/WEIGHT Passage Height 2003 * Passage Breadth 760 * Passage Width 580 * Weight of the equipment Not more than 80 Kg * DOOR FRAME CONSTRUCTION Construction of Door Frame (Walk-through Arch) Light weight
Requiredrigid
Requiredlaminated side panels and cross piece with ABS plastic boots for panel protection * Material of Walk- through Arch WOOD POLYCARBONATE
RequiredWOOD
RequiredFIBER
RequiredPVC Provided with base wheels for easy mobility No Yes
RequiredNo Provided with a floor panel to attach both side panels to give stability & rigidity to the structure No Yes
RequiredNo Ramp over the floor panel - Covered with synthetic carpet for long life No Yes
RequiredNo Water proof Yes Yes
RequiredNo Weather proof Yes Yes
RequiredNo DETECTION Metals detectable Ferrous
RequiredNon-Ferrous
RequiredFerrite & Alloys * Uniform Detection from top to bottom Yes * Capable of Metal Detection in all orientations Yes * 2/7 Detect multiple objects of various size
Requiredweight and shape in all the zones simultaneously from head to toe Yes * Capable of Metal Detection in walking speed of interception Yes * Performance independent of the speed of person passing through Yes * ALARM/INDICATION DISPLAY Audio-Visual indication on detection at side panels and control panel Yes * Audible Alarm on detection with adjustable volume Yes * Bar Display to indicate Metal location w r t Height on person Yes Yes
RequiredNo Audio-Visual Low Battery indication Yes * Back-lit Display LCD * SENSITIVITY Operational Frequencies User selectable * Number of User Selectable frequencies 15 * Adjustable Sensitivity Yes * Number of Sensitivity Levels/Steps 18 * Uniform Sensitivity in all zones Yes * Calibration Both manual and Auto Calibration * SECURITY Provision to secure access to the control unit by a pass word protected alpha numeric keypad Yes * Re-setting after alarm condition Re-set itself (auto) within 3 Seconds * Walk/Stop indicator for traffic control Yes * Control Panel Easy accessible control panel
Requiredwith modular * 3/7 design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and or by password. User friendly self- testing diagnostics to identify faulty condition Yes * INTERFERENCE SUPPRESSION REJECTION Automatic synchronization for DFMDs Do not interfere with adjacent installed DFMDs located close to each other upto a distance of 1 * Static Metal Compensation Not affected by heavily reinforced floors/roof tops/walls Yes * High discrimination between small masses and personal metallic objects Yes * Not affected by external RF transmission and EMI (Electro Magnetic Interference) Yes * Not affected by by interference
Requiredwhich is mains-borne or radiated by external source Yes * Not affected by the operation of radio
RequiredMobile phones
Requiredwalkie- talkie sets
RequiredX-ray monitors etc within a distance of one meter Yes * Not affected by moving metallic items such as trolleys
Requiredopening closing of metallic gate etc
Requiredone meter away from the archway Yes * HEALTH & SAFETY Harmless to wearers of pacemakers
Requireddefibrillators or other vital support systems
Requiredpregnant women and Yes * 4/7 magnetic storage media Not affected by infrared
Requiredultraviolet
Requiredelectromagnetic or RF radiation Yes * Conform to international security standards of Safety Radiation Yes * Harmless to magnetic media
Requiredelectronic devices
RequiredFilm safe and Data safe Yes * ENVIRONMENTAL Operating Temperature Range (Degree C) Minus 20 to Plus 55 Degree C Minus 20 to Plus 55 Degree C
RequiredMinus 10 to Plus 50 Degree C
RequiredMinus 5 to Plus 55 Degree C Operating Humidity - Non condensing (RH) (%) 95 * POWER SUPPLY BATTERY Source of Power Operated by AC mains supply and alternatively by rechargeable battery * Power Supply 100 to 260 VAC * Battery Re-chargeable
Requiredmaintenance free
Requiredinternal battery with charger Re-chargeable
Requiredmaintenance free
Requiredinternal battery with charger
RequiredStandard UPS Battery Back-up in full function (hours) 10 6
Required8
Required10
Required12
Required14
Required16 ACCESSORIES One Standard Test Piecec for each machine for testing during commissioning maintenance Inclusive in the scope of supply * Training tools- Charts
Requiredslides
Requiredtraining brochure
Requiredtraining work model
Requiredblowup diagram
Requiredvideo films on demonstration and use etc Inclusive in the scope of supply * Technical manual giving full description of the item
Requireduser's handbook and literature Yes * 5/7 Practical training 1 Day At least one day in each quarter of the year continuing during warranty period
Required1 Day
Required2 Days
Required3 Days Availability of Spares for a period of 7 years after the warranty period Yes Yes
RequiredNo Ruggedized polypropylene shock proof container compliant to IP 65 or better for safe transportation of the equipment Yes Yes
RequiredNo WARRANTY Warranty (Years) 3 3
Required4
Required5 CERTIFICATION Availability of Test Report from NABL ILAC accredited or Central Government Lab to prove conformity of products to the specification Yes Yes
RequiredNo Test Report Number & Date GARR0025 dated 31 August 2016 * Name & address of the Lab Northwest EMC Labs
Required3801 E Plano Pkwy
RequiredPlano
RequiredTX - 75074
RequiredUSA * * Bold specifications are the golden parameters.