Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹56,000Qualified Make: CHLOROMAK CMK
Model: CMK-03 | Make: CHLOROMAK CMK
Model: CMK-03 | ₹56,000 | L1 | Qualified |
| 2 | Disqualified Make: bluebird
Model: Grandiose | Make: bluebird
Model: Grandiose | - | - | Disqualified |
| 3 | Disqualified Make: Aquaguard
Model: AQUAGUARD & AQUAGUARD 200 UV WATER PURIFICATION SYSTEM 4TH FLOOR ANNEX BUILDING NEW CUSTOM HOUSE MUMBAI BALLARD ESTATE MUMBAI 01 CONTACT NO 022 22757497 | 227574 | Make: Aquaguard
Model: AQUAGUARD & AQUAGUARD 200 UV WATER PURIFICATION SYSTEM | - | - | Disqualified |
| 4 | Disqualified Make: piyoindia
Model: 50LPH RO | Make: piyoindia
Model: 50LPH RO | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
17 Aug 2018, 2:00 pmClosed
Potable water purification system Average Turn Over of Last 3 Years 1 Lakh (s) Experience with Gov. Required 2 Year (s) Potable Water Purification System ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier
Gravity operated water purifier
Water Purifier electro- deionization Based Ultraviolet (UV) LAMP Yes Yes
No Ultra Voilet (UV) Lamp power consumption 18 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 3 INPUT PARAMETERS Input Water TDS 2000 2000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 25-35 25-35
30-40
90-100
70-80
50-60 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - 1/3 Output water capacity (Litre/Hour): 50 50 Arsenic and Floride removal capability true true
false Yes is better Misc
warranty etc Thin-film composite membrane Yes Yes
No
NA High Pressure Pump Yes - Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes
No Pre Filter Vessels: Yes Yes
No Micron Filter Yes Yes
No Membrane Housing Yes Yes
NA Auto cut Yes Yes
No No of candles (Nos) 5 Installation Type Wall mounted Wall mounted Warranty period ( for free replacement of machine 3 2
3
1 Higher is better Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 3 2
1 Higher is better Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes
NA Chloride & Flouride removal facility Yes with Pump Yes with Pump Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 - - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 2/3 1 Rajendra Prasad Mali 305404
GOVERNMENT COLLEGE
KEKRI
AJMER ROAD
KEKRI (AJMER) 2 15
472473
GEM/2018/B/66786
Potable water purification system
15 days
Rajasthan; Ajmer
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Potable water purification system Average Turn Over of Last 3 Years 1 Lakh (s) Experience with Gov. Required 2 Year (s) Potable Water Purification System ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier | - | - | - |
| Gravity operated water purifier | - | - | - |
| Water Purifier electro- deionization Based Ultraviolet (UV) LAMP Yes Yes | - | - | - |
| No Ultra Voilet (UV) Lamp power consumption 18 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 3 INPUT PARAMETERS Input Water TDS 2000 2000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 25-35 25-35 | - | - | - |
| 30-40 | - | - | - |
| 90-100 | - | - | - |
| 70-80 | - | - | - |
| 50-60 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - 1/3 Output water capacity (Litre/Hour): 50 50 Arsenic and Floride removal capability true true | - | - | - |
| false Yes is better Misc | - | - | - |
| warranty etc Thin-film composite membrane Yes Yes | - | - | - |
| No | - | - | - |
| NA High Pressure Pump Yes - Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes | - | - | - |
| No Pre Filter Vessels: Yes Yes | - | - | - |
| No Micron Filter Yes Yes | - | - | - |
| No Membrane Housing Yes Yes | - | - | - |
| NA Auto cut Yes Yes | - | - | - |
| No No of candles (Nos) 5 Installation Type Wall mounted Wall mounted Warranty period ( for free replacement of machine 3 2 | - | - | - |
| 3 | - | - | - |
| 1 Higher is better Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 3 2 | - | - | - |
| 1 Higher is better Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes | - | - | - |
| NA Chloride & Flouride removal facility Yes with Pump Yes with Pump Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 - - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 2/3 1 Rajendra Prasad Mali 305404 | - | - | - |
| GOVERNMENT COLLEGE | - | - | - |
| KEKRI | - | - | - |
| AJMER ROAD | - | - | - |
| KEKRI (AJMER) 2 15 | - | - | - |
Exempted
17 Aug 2018
13 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_472473.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid