| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹32.0 L+₹2.1 L (6.98%)Rejected-Finance 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹35.9 L+₹5.9 L (19.8%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L3 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 4 | L4₹37.3 L+₹7.4 L (24.7%)Rejected-Finance 42 43A VIDYA SAGAR SARANI PALLY BARISHA KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | L4 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 5 | L5₹38.0 L+₹8.0 L (26.7%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
22 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KOLKATA
Headquarters commander Works Engineers Military Engineer Services No 1, National Library Avenue Alipore, Kolkata 700 027
REPAIR / MAINT OF HT NETWORK SYSTEM AT FORT WILLIAM UNDER GE(FW) KOLKATA
2021_MES_422308_1
8112/E-53/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FW KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
GE FW KOLKATA
₹98,000
Yes
15 Apr 2021
15 Feb 2021
24 Mar 2021
15 Feb 2021
22 Mar 2021
8 Mar 2021
15 Feb 2021 - 25 Feb 2021
60 days
Amount
NOTES :(i)The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. (ii) It is highlighted that the cretin condition of General Condition Of Contracts (IAFW-2249) has been modified as direction of MOD i.e inclusion of performance security, deletion of risk & cost provisions and increase in defects liability period all as specified in tender document. The tenderers should keep in mind while quoting their offer
Disconnecting and taking out of unserviceable HT XLPE cable 6.6 KV of size 70 Sqmm to 300 Sqmm 3 Core of any description from trenches, Floors, walls, GI Pipes etc,seggrating the serviceable cable and depositing at AGE E/M Store Yard for relaying complete all as specified and directed. Note:- (i) The contractor will be responsible for any type of damage / punctured of existing serviceable HT cable . (ii) Before laying new cable or relaying of old cable meggaring of complete cable in presence of Engineer-in-Charge will be carried out by contractor without any extra cost. (iii) Dameage of HT cable will be responsibility of the contractor and new same size cable will be provided by contractor in lieu old cable without extra cost.
Relaying XLPE insulated, screeded PVC bedded, galvanised steel strip or wire armoured electric power cable 6600 Volts grade, cross sectional area 70 Sqmm to 300 Sqmm, 3 Core with stranded aluminium conductor cable, laid in trench / passing through pipe (Item retrived through item No 2 above shall be reused) complete all as directed by the Engineer-in-Charge. Note:- Necessary earth work shall be measured and paid separately.
Supply and laying of XLPE insulated (Earthed), screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 6.6 KV grade, cross sectional area 95 Sq mm, 3 core complete all as specified and as directed.
All as per item No 4 here-in-before but cross sectional area 240 Sqmm, 3 Core
All as per item No 4 here-in-before but cross sectional area 300 Sqmm, 3 Core
Supply, Jointing and testing of outdoor termination heat shrinkable type jointing kit complete with jointing materials and accessories suitable for 6.6 KV(Earthed) grade XLPE armored Aluminium conductor cable of size 95 Sqmm 3 core , including preparation of burnt out HT cable and taking out old jointing kit complete all as specified and as directed.
All as per item No 7 here-in-before but of size 240 Sqmm to 300 Sqmm complete all as specified and as directed.
Supply, Jointing and testing of indoor termination heat shrinkable type jointing kit complete with jointing materials and accessories suitable for 6.6 KV(Earthed) grade XLPE armored Aluminium conductor cable of size 95 Sqmm 3 core , including preparation of burnt out HT cable and taking out old jointing kit complete all as specified and as directed.
All as per item No 9 here-in-before but of size 240 Sqmm to 300 Sqmm
Supply, Jointing and testing of straight through heat shrinkable type jointing kit complete with jointing materials and accessories suitable for 6.6 KV(Earthed) grade XLPE armored Aluminium conductor cable of size 95 Sqmm 3 core , including preparation of burnt out HT cable and taking out old jointing kit complete all as specified and as directed.
All as per item No 11 here-in-before but of size 240 Sqmm to 300 Sqmm
Excavating in trenches n. exc 1.5m wide and not e. 1.5m in depth for foundation of poles, laying under ground cables, etc and getting out in soft/loose soil complete as specified and directed. Note : Excavation shall be carried out manually not with using JCB
Returning, filling in, including spreading leveling watering and well ramming in layers not exc 25 cm as in soft / loose soil complete as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point in soft / loose soil complete as specified and directed.
Material and Labour of sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be measure after punning down.
Supplying and laying reinforced precast concrete cable cover, class HV type - 1 flat, size 300mmx l80mm x 40mm complete all as specified and directed.
Re-laying of old HT cable cover after obtained from taking out UG cable and cleaning of cover complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including supply and laying of HDPE pipe of 90 mm dia PE 80 IS: 14333 grade, working pressure 10 KGF / CM2, complete all as specified and directed.
Dismantling / Disconnecting electric connection of underground HT, XLPE Cable, 6.6 KV upto 70 to 300 Sqmm from both sides and locating the fault in HT cable upto 01 KM with fault locating machine in the entire length and removing the moisture from HT cable charging the HT cable with help of modern fault detector equipment be expert engineers and reconnecting and commissioning of cable complete all as specified and as directed. Note:- The work will be executed after obtaining proper shutdown from main power house liase with JE E/M.
Disconnecting HT/LT connection of transformer and opening up the top cover of transformer of capacity 500 kVA to 750KVA for checking the conditions to carryout repairs and over hauling at site, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bus rods including necessary soldering/jointing etc and after complete repair refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections as per instructions of relevant BIS code complete all as directed by GE/AGE
All as per ser Item No 21 but transformer of capacity 315 KVA to 400 KVA
All as per ser Item No 21 but transformer of capacity 200 KVA to 250 KVA
All as per ser Item No 21 here-in-before but transformer of capacity 75 KVA to 160 KVA Notes for item no 21 to 24 :(i) Labour component required for the repalcement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item (ii) Major parts as under shall be measured and paid separately under appropriate item of this BOQ (iii) Dehydration/ filtration of transformer oil shall be measured and paid separately under relevant item of this BOQ’ (iv) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item
Supply only in replacement HT bushing including gasket suitable for transformer of capacity 500 KVA to 750 KVA complete all as directed (for three phases)
All as per Item No 25 here-in-before but suitable for transformer of capacity 315 KVA to 400 KVA
All as per Item No 25 here-in-before but suitable for transformer of capacity 200 KVA to 250 KVA
All as per Item No 25 here-in-before but suitable for transformer of capacity 75 KVA to 160 KVA
Supply only in replacement LT bushing including gasket suitable for transformer of capacity 500 KVA to 750 KVA complete all as directed (for three phases & Neutral)
All as per Item No 29 here-in-before but suitable for transformer of capacity 315 KVA to 400 KVA
All as per Item No 29 here-in-before but suitable for transformer of capacity 200 KVA to 250 KVA
All as per Item No 29 here-in-before but suitable for transformer of capacity 75 KVA to 160 KVA
Supply only in replacement breather assembly complete with silica gel for transformer from above 300 KVA upto 400 KVA of any make, type and capacity complete all as specified and directed. Note : Silica Gel will be measured and paid separately under respective item.
Supply only silica gel for transformer of any make, type and capacity complete all as specified and directed.
Supply only transformer oil ISI marked in sealed containers confirming to IS-335 with dielectric strength of not less than 40 KV and testing for strength including recording results complete all as specified. Note:- (i) Purchase vouchers alongwith manufacturer's test certificate shall be produced to Engg-in-charge. (ii) Nos of sealed containers shall be recorde in MB Make:- CASTROL/IOCL(SERVO)/HP
De-hydration and filtration of transformer oil by using dehydration and filtration plant, heating and filtration of oil to be carried out till the di-electric strength reaches 40 KV to 60 KV withstand for one minute is achieved and acidity test for any capacity of transformer complete all as specified and directed.
Material and labour for preparation of old painted steel or iron surfaces of transformer of transformer capacity 75KVA to 100KVA by scrapping with steel wire brush/scrapper emery paper, etc. and applying one coats of synthetic enamel smoke grey paint (painting shall be done by spray machine) including writing of SM No, MES No etc. with approved colour synthetic enamel thick paint in white back ground complete all as specified and directed.
All as per Item No 37 here-in-before but for transformer capacity 200 KVA to 250 KVA
All as per Item No 37 here-in-before but for transformer capacity 315 KVA to 500 KVA
All as per Item No 37 here-in-before but for transformer capacity 630 KVA to 750 KVA
Repair and overhauling of 6.6 KV any capacity VCBs of receiving /distribution System with dusting/cleaning by smooth brushing or dry cotton and lubricating of movable mechanism suitably with oil/grease and replacement of unserviceable/burnt out/worn out spare parts with new one as per existing make, duly commissioned in the VCBs at 6.6 KV bulk receiving centre including necessary inspection, reassembling , testing , re-commissioning, etc complete for smooth functioning of the equipments to ensure desired result including taking down/dismantling of existing unserviceable spares parts of VCB/Capacitor Banks all as directed by Engineer-in-charge. Notes :(i) Labour component required for the repalcement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item (ii) Major parts as under shall be measured and paid separately under appropriate item of this BOQ . (iii) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item . (iv) Repair, overhauling & testing of VCB shall be carried out by authorized competent persons of OEMs or their accredited/ authorised agencies and contractor shall be submitted supporting document of authorized representative of existing VCB to GE . The service charge of OEM shall deem to be included in above quoted rate.
Callibration of microprocessor E/F and O/C relay of VCB and calibrating with portable relay test kit to set time and fault level and adjustment of setting with according to load & time with CESC for proper functioning complete all as specified and directed.
Supply only in replacement bakelite kitkat with 2 / 5/ 10 Amps HRC fuse suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed. Make: As per existing OEM or ISI marked make as approved by GE
Supply only in replacement of indicator lamp LED 110 Volt AC with holder (R/Y/B in colour) suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed. Make: As per existing OEM or ISI marked make as approved by GE.
Supply only in replacement of shunt trip coil 24 to 30 volts DC suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed. Make: As per existing OEM or ISI marked make as approved by GE.
Supply only in replacement motor and gear assembly 110 volts AC / 24 Volts DC suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed. Make: As per existing OEM or ISI marked make as approved by GE.
Supply only in replacement TNC switch of capacity 25 Amp, 2 NO + 2NC with barrel lock suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed. Make: As per existing OEM or ISI marked make as approved by GE.
Supply only in replacement of isolating contact assembly suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed. Make: As per existing OEM or ISI marked make as approved by GE.
Supply only in replacement of primary wound metering and protection current transformer with CT's ratio 100/50/5 Amps suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed. Make: as per existing OEM or approved by GE.
Supply only in replacement Numerical 3 phase over current and earth fault relay with trip circuit supervision, true RMS measurement, self disgnostic feature, built in CB fail protection, fault data retrievable through communication, low AC and DC burden, 5A current setting, Data communication facility complete with connection and testing on full load complete all as specified and directed. Make: As per existing OEM or ISI marked make as approved by GE.
Supply only in replacement 3 phase over current and earth fault relay for HT 6.6 KV VCB panel with high set complete with connection and testing on ffull load complete all as specified and as directed. Make: As per existing OEM or ISI marked make as approved by GE.
Supply and fixing in repair Multi Function Meter LCD Display with Parameters - Amp, Volt, Freq, PF, RPM, % Load, % Unbal, Amp phase angle, Maximum Demand complete all as specified and as directed.
Supply only in repair Vaccum interrupter bottle for vaccum circuit breaker of 400 /800/630 Amps in HT panel 6.6 KV grade complete all as specified and as directed. Make: As per existing OEM or ISI marked make as approved by GE.
Material and labour for preparation of old painted steel or iron surfaces of VCB panel of any capacity by scrapping with steel wire brush/scrapper emery paper, etc. and applying one coat of synthetic enamel smoke grey paint (painting shall be done by spray machine) including writing of SM No, MES No etc. with approved colour synthetic enamel thick paint in white back ground complete all as specified and directed
Material and labour for preparation of old painted steel or iron surfaces of RMU of any way by scrapping with steel wire brush/scrapper emery paper, etc. and applying one coat of synthetic enamel smoke grey paint (painting shall be done by spray machine) including writing of SM No, MES No etc. with approved colour synthetic enamel thick paint in white back ground complete all as specified and directed
Opening the front and rear cabinet of the RMU 3 way 630 Amps 6.6 KV de-carbonizing and replacement of moving and fixed contracts, if rquired, lubricating, checking the pressure of SF-6 gas, wiring with suitable size of copper conductor cable, checking of micro processor EF / OC relay, tripping coil electrical and checking for manual / auto tripping system complete and placing the SF-6 RMU and isolating unit in its original position as per OEM complete all as specified and directed.
Supply and fixing in replacement plug in voltage presence indicator system (VPIS) type WIM for Ring Main Unit SF-6 of capacity 6.6 KV, 630 Amps complete all as specified and directed.
Supply and fixing in replacement of fuse assembly by opening fuse canisters of RMU positioned behind interlocking cover for Ring Main Unit SF-6 of capacity 6.6 KV, 630 Amps complete all as specified and directed
Supply and fixing in replacement of Bushing assembly for Ring Main Unit SF-6 of capacity 6.6 KV, 630 Amps complete all as specified and directed.
Supply and fixing in replacement of terminal contact piece with silicone coupling by opening the terminal cover for Ring Main Unit SF-6 of capacity 6.6 KV, 630 Amps complete all as specified and directed.
Supply and fixing in replacement of gear assembly grooved inside and outside for operating of Ring Main Unit SF-6 of capacity 6.6 KV, 630 Amps complete all as specified and directed.
Supply and fixing in replacement of Operating handle for Ring Main Unit SF-6 of capacity 6.6 KV, 630 Amps complete all as specified and directed.
Supply and fixing in replacement of ring type current transformer 100 /1 Amps by opening the cable compartment cover fixed the CT on cable elbow plug / T plug complete for Ring Main Unit SF-6 of capacity 6.6 KV, 630 Amps complete all as specified and directed.
All as per item no 63 here in before but 50 /1 complete all as specified and directed. Make: SIEMENS / ABB/ Schneider / Crompton Greaves
Supply and fixing of Trifurcation boot 6.6 KV capacity for cable termination joint RMU incoming and outgoing trminals including taking out old defective trifurcation boot for Ring Main Unit SF-6 of capacity 6.6 KV, 630 Amps complete all as specified and directed.
Supply and laying of 2.5 mm thick insulated synthetic mat of confirming to IS 15652 : 2006 and meeting the requirement of IS 5216 (Part 1, 2 & 3) IS 8437, IFC - 479 Pub-1, alongwith suitable adhesive / chemibound, PU resin, water proofing compound and sealing materials all as per IS : 15652 class - B and suitable for working voltage upto 6.6 KV with trolley movement complete all as specified and directed.
Callibration of microprocessor E/F and O/C relay of Ring Main Unit SF-6 capacity 6.6 KV, 630 Amps complete and calibrating with portable relay test kit to set time and fault level and adjustment of setting with according to load & time with main power supply incl replacement of relay battery for proper functioning complete all as specified and directed.
Material and labour for taking out of burnt primary / secondary copper windings of HT 11 KV / 6.6 KV transformer and cleaning all the limbs, replacing with the same with fine enamelled bare copper conductor as per relevant BIS of same gauge size, turns and weight and keeping the same into the hot air oven till the moisture evoporates for working complete all as specified and directed. Note: Rates quoted deemed to be inclusive of all Misc items such as cotton tape, warnishing, impregnated paper etc.
Supply and fixing of MS Cross arms, bracings, supports etc. incl nuts, bolts, washers, welding, bending, drilling including application two coats of aluminium paint over a coat of red oxide primer after preparation of surface including taking down old steel members complete all as specified and directed.
Supply and fixing in repair of Air circuit breaker 4 pole 415 volts, 50 KA manual draw out type with microprocessor release of capacity 630amps including all necessary accessories and all as specified in SSR Part -I and as directed. Make:- ABB / L&T / LEGRAND / SIEMENS
All as per Item No 70 here-in-before but with microprocessor release of capacity 800 amps
All as per Item No 70 here-in-before but with microprocessor release of capacity 1000 amps
Material and Labour for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation of pole complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B2 using 20mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cemet complete all as specified and directed.
Material and Labour for PCC 1:3:6 type C1 using 40mm graded aggregate as in coping / collar of poles and foundation including necessary formwork etc complete all as specified and directed.
Supply and fixing Cable Route indicator for HT cable with GI plate and GI pipes 50mm dia, 1.2 mtr long light grade showing MES HT cable / HT Joint and voltage including necessary earth work and cement concrete 1:2:4, 20 mm crushed stone aggregate of size 200mm x 200mm x 200mm including taking down old unserviceable cable route indicator complete all as specified and directed.
Supply and fixing in repair Earth Continuity Conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required with 32 x 6 mm dia GI Strip complete all as specified and directed.
Material and labour for Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with galvanised earthing strip of size 32mm x 6mm by means of nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not esceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete including taking down and testing on completion complete all as specified and as directed by the Engineer-in-Charge.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
Ultimate Solution Company
M/S J S ENTERPRISES
SANTOSH INTERNATIONAL
EASTERN REFRIGERATION AND ELECTRICAL CO
MS AP CONSTRUTION AND CO
INDIA ELECTRICAL EQUIPMENTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .