Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L1 | Accepted-AOC Lowest bidders | |
| 2 | L2₹46.9 L+₹8.4 L (21.8%)Rejected-Finance WZ 109 PLOT NO 327 CHAND NAGAR NEW DELHI | L2 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | Vishal Traders L1 | Suman Uni Controllers L2 |
|---|---|---|---|---|---|
| 1.00 | Draining and cleaning of alkaline chemical tank ,Hot water tank, Cold water tank in installed basement of de-greasing palnt and 05 Nos of ETP tank complete and removing frozen solid sludge from all tank in each month.
Solid sluge and other wastage should be disposed / thrown at a minimum distance of 100 metre away from the plant or a location decided by users with in the 505 ABW premises complete all as specified and as directed.
Details of Tank - (a) 05 ETP tank ( Clean in each Month)
Total - 5 x 6 (month ) = 30 month
(b) 03 Tank (Alkaline Tank-01, Hotwater Tank-01, Cold Water-01)
Total = 3 x 3 (clean the tank once in 02 month) = 9 Month
G total - 30+9 =39 Month | 39 | Each Job | 3,500 ₹1,36,500 Lowest | 4,389 ₹1,71,171 |
| 2.00 | M&L for cleaning and repairing of all stainless steel spray pipe lines of various size including nozzles laying on the floor inside the de-greasing washing chamber and connected other accessories complete. dismatling / removal the complete spray line alongwith oulet valve nozzle, coupling with packing after then complete drain out any remaining frozen materials inside the pipe line and nozzels,and reassembled , making good any leakage in pipe line with necessary gas cutting, welding , polishing, testing as per site requirement complete all as specified and as directed. | 1 | Each Job | 25,000 ₹25,000 Lowest | 28,000 ₹28,000 |
| 3.00 | M&L for overhauling of squirrel cage induction electric motor 3 phase 415 volts , 1455 RPM of capacity 60 HP/45KW with pump set complete cleaning the impeller and dischage /suction casing of the pump including repairs to pump complete with dismantling and re-assembly and testing
NOTE:
(i) Rewinding of motor by super enamelled copper wire with class F insulation necessary disconnecting electric connections/ taking down and shifting to local workshop and brought back to site complete reassembled as per existing location . Lubrications oils and apply greasing to all moving parts.
(ii) Repair/replacement, retrofit ,of all major/ minor parts i.e rotor,stator,winding,terminal box ,bearing, shaft , Fan, impeller , gland assembly, bearning assembly , coupling,Contact Terminals and checking and replacing the burnt cable glands and consumable items complere as requirement for smooth functioning of motor & pump set ,all materilas are deemed to be include in the quoted rate by the contractor complete all as specified and as directed. | 1 | Each Job | 27,500 ₹27,500 Lowest | 41,895 ₹41,895 |
| 4.00 | All as per srl item No 3 here-in-before but motor of capacity 7.5 HP complete complete all as specified and as directed. | 2 | Each Job | 6,500 ₹13,000 Lowest | 9,518 ₹19,036 |
| 5.00 | All as per srl item No 3 here-in-before but motor of capacity 5.0 HP complete all as specified and as directed. | 3 | Each Job | 5,500 ₹16,500 Lowest | 8,300 ₹24,900 |
| 6.00 | All as per srl item No 3 here-in-before but motor of capacity 3.0 HP complete all as specified and as directed. | 4 | Each Job | 4,500 ₹18,000 Lowest | 4,900 ₹19,600 |
| 7.00 | Isolate/de-energize the supply to the LT Panel Board of capacity ranging from 100 Amps to 400 Amps and voltage 415 Volts/230 Volts, opening the doors/covers of the cubicle enclosure for carrying out the servicing/maintenance/repairs of the Panel Board,modification and switch gear,MCCB, metering etc and re-fixing the same/New in place after repairs including testing and commissioning of the panel board comprising of the following:-
a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower .
b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required.
c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required.
Note :- Spares will be measured and paid separately. | 3 | Each Job | 3,000 ₹9,000 Lowest | 14,000 ₹42,000 |
| 8.00 | Taking down complete and supply & fixing in replacement of centrifugal air blower with motor of capacity 5 HP, 3P,415 Volt including complete fitting with existing suction / delivery duct necessary retrofit as per site requirement complete all as specified and as directed.
Make :- Kirloskar/ Crompton /GEC | 2 | Each | 27,500 ₹55,000 Lowest | 31,400 ₹62,800 |
| 9.00 | Supply and replacement of foot valve heavy duty of size 50mm complete all as specified and as directed.
Make :- Zoloto/Kirloskar/ Leader/ AUDCO | 3 | Each | 2,000 ₹6,000 Lowest | 2,680 ₹8,040 |
| 10.00 | Supply and replacement of AC induction tubular heater 9 KW, 415 volts, 3 phase of length 1.5 m length or as per sample with MS powder coated terminal cover as per sample complete all as specified and as directed.
Make :- Telelec/Escort/USGC/Theeta | 20 | Each | 3,000 ₹60,000 Lowest | 3,740 ₹74,800 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
22 Jul 2026, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR AND REPLACEMENT OF DEFECTIVE SPARE OF CAR WASHING PLANT DEGREASING PLANT AND HULL PAINTING PLANT LOCATED IN DELHI CANTT UNDER GE (U) PM DELHI CANTT 10
2026_MES_774441_1
GE(U)/PM/D-20/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
Delhi Cantt
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹96,000
Yes
8 Aug 2026
24 Jun 2026
25 Jul 2026
24 Jun 2026
22 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Draining and cleaning of alkaline chemical tank ,Hot water tank, Cold water tank in installed basement of de-greasing palnt and 05 Nos of ETP tank complete and removing frozen solid sludge from all tank in each month.
Solid sluge and other wastage should be disposed / thrown at a minimum distance of 100 metre away from the plant or a location decided by users with in the 505 ABW premises complete all as specified and as directed.
Details of Tank - (a) 05 ETP tank ( Clean in each Month)
Total - 5 x 6 (month ) = 30 month
(b) 03 Tank (Alkaline Tank-01, Hotwater Tank-01, Cold Water-01)
Total = 3 x 3 (clean the tank once in 02 month) = 9 Month
G total - 30+9 =39 Month | 39 | Each Job | - | - |
| 2 | M&L for cleaning and repairing of all stainless steel spray pipe lines of various size including nozzles laying on the floor inside the de-greasing washing chamber and connected other accessories complete. dismatling / removal the complete spray line alongwith oulet valve nozzle, coupling with packing after then complete drain out any remaining frozen materials inside the pipe line and nozzels,and reassembled , making good any leakage in pipe line with necessary gas cutting, welding , polishing, testing as per site requirement complete all as specified and as directed. | 1 | Each Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
D20SCHOFCREDIT.pdf
Additional Documents • 0.55 MB
D20TENDER.pdf
Tender Documents • 1.04 MB
BOQ_867192.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .