| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC 266 UTTAMNAGAR NDA ROAD PUNE 411023 | PUNE | MAHARASHTRA | 411023 | L1 | Accepted-AOC BEING LOWEST AND FOUND REASONABLE | |
| 2 | L2₹28.7 L+₹20,474.29 (0.72%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹28.9 L
EMD Value
₹58,000
Closing Date
10 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I R AND D GIRINAGAR PUNE
GARRISON ENGINEER I R AND D GIRINAGAR PUNE
ADDN ALTN TO CLASS ROOM NO B 159 FOR DSTSC NAVY AND POVN OF CERTAIN BR WORKS FOR TRG ADM INFRASTRUCTURE OF NAVAL FACULTY PARKING SHED FOR TWO WHEELERS WITH HARD STANDING AT BLOCK NO P36 P-37 PROVN OF CERTAIN BR WORKS AND EM WORKS AT MILIT
2022_MES_503391_1
GE I R AND D GIRINAGAR TOKEN 41 OF 2021-22
Open Tender
Civil Works
Item Rate
120 days
GARRISON ENGINEER I R AND D GIRINAGAR PUNE
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER I R AND D GIRINAGAR PUNE
₹58,000
Yes
13 Mar 2022
24 Jan 2022
12 Feb 2022
24 Jan 2022
10 Feb 2022
28 Jan 2022
24 Jan 2022 - 27 Jan 2022
60 days
Amount
ADDITION /ALTN TO CLASS ROOM N B-159 FOR DSTSC (NAVY) AT MILIT (B&R WORKS) Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
M&L for Rendering 15mm thick on brick or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth without using extra cement, including necessary scaffolding, safety precaution to be use height up to 13Mtr complete all as specified & directed
M&L for rendering 15mm thick on precast cement concrete block masonry with solid block, brick work surface in CM 1:6 finished even and smooth without using extra cement complete all as specified & directed
M&L for two coats of oil bound distemper over a coat of primer on New surfaces of wall complete all as specified & directed
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43litre/10sqm over and including priming coat of exterior primer applied @ 0.90litre/10Sqm over new surfaces of wall including necessary scaffolding required for painting work, safety measures etc. complete all as specified & directed
Taking down chowkats or frames of wooden or steel exc 1.5 sqm & n.exc. 4 Sqm with Shutters (without taking off shutters from the frames) complete all as specified & directed
M&L for pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified, supplied and fixed size 105X60mm complete all as specified & directed.
M&L for PCC 1:3:6 type C-0 (using 12.5mm graded aggregate) as in filling steel frames etc. incl necessary form work complete all as specified & directed
M&L for 30mm thick Flush shutters with lipping all around of solid core construction with block board core and ply wood face panels commercial type on both side complete all as specified & directed
M&L for brass, sliding door bolt with sand or die cast brass hasp, staple (bolt type) length 300mm fixing bolt with rolled or drawn brass bolts and fixed complete all as specified & directed
M&L for floor door stopper of brass body and tongue with hard drawn steel spring overall length of cover plate 140mm complete all as specified & directed
S&F 150mm long extruded brass handles, fabricated type polished complete all as specified & directed
S&F 200mm long brass barrel tower bolts, with cast or sheet barrel and rolled and cast bolts fixed complete all as specified & directed
S&F Door closer Aluminium (extruded section body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80kg and fixed complete all as specified & directed.
M&L for 0.9mm thick decorative laminate type1 of surface finish, colour and pattern as approved by Engr-in-charge, fixed with approved adhesive as per manufacturer's instructions complete all as specified & directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified & directed
S&F of mineral fibre acoustic suspended ceiling system with Dune (Board) Edge Tiles with 24mm exposed grid (Make Armstrong or Saint Gobain). The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance > 85%, Thermal Conductivity k=0.052 - 0.057 w/m K, Colour White, Fire Performance UK class 0/ Class 1 (BS 476 pt - 6 & 7) in module size of 600mm x 600mm x 16mm, suitable for green building application, with Recycled content of 32%. The tile shall be laid on Armstrong Prelude 38 (or equivalent in Saint Gobain) with 24mm wide T- section flanges colour white having rotary stitching on all T section i.e. the Main Runner, 1200mm & 600mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kg/Sqm & minimum pull out strength of 100kg. The T section have a Galvanizing of 90 grams per Sqm. Suspension system accessories (manufactured by Armstrong/Saint Gobain) consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised thickness of 80gsm, A pre Straightened Hanger wire of dia - 2.5mm of 1.8m length, thickness of 80gsm and a tensile strength of 344-413MPa, along with Adjustable hook clips of 0.8mm thick, galvanised spring steel of 2.68mm with a minimum pull strength of 110kg. The adjustable clip also consists of a 3.5mm aquiline wire to be used with the main runner. Main runner shall be spaced at 1200mm centres securely fixed to the structural soffit at 1200mm maximum centre. The first/last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450mm maximium centres complete all as specified & directed Make/Manufactures:- Armstrong or Saint Gobain.
M&L for acoustic wall paneling comprising of GI steel section framework of 600 x 600mm centre to centre using vertical section of 48mm x 34mm x 0.55mm and horizontal sectionof 50mm x 32mm x 0.55mm fixed to wall using necessary fittings. Glasswool of 50mm having density 48Kg/Cum is then inserted in the slots. Finally light weight calcium silicate incombustible panels of size 595 x 595mm x 12mm fixed on grid word with screws all as specified and directed.
M & L for granite 18mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed.
S&F three track sliding window with 4mm thick tinted glass in two shutter and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing including good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. Series of aluminium section as per Jindal is (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S&F zebra venition blends with design on inner/outer face alternate blinds, folding type made out of fibre cloth fixed, to wall with necessary Aluminium brackets, screws etc. including Alluminium frame for venition blinds etc. all as approved by Engr-in-Charge and all as specified and directed. Make;- Vista, Levador or equivalent.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed
Demolition of cement concrete in floors and pavings n. exc. 15cm thickness (below or above ground level) complete all as specified & directed
M&L for precast cement concrete block masonry with solid blocks of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate, exc. 10 cm in width and setting in CM 1:6, complete complete all as specified & directed
M & L for cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in floor levelling course and in similar situations 25mm thick complete all as specified & directed
M&L vitrified coloured glazed ceramic tiles 10mm thick (square/regtangular) polished , area of each tiles not exc 0.36 sqm in floors etc and joineted neat in cement slurry and pointed in white or colour cement to match over 15mm thick screed bed in CM 1:6 complete all as specified & directed
S&F 15mm dia GI pipe medium grade with all fittings and fixed complete to walls and ceilings or laid in floor or fixed to walls complete all as specified & directed
S&F in repair Long body CP Bib taps 15mm dia with crutch or butterfly handle fancy type complete all as specified & directed
S&F 8feet x 4feet Magnetic white writing board, wall hanging type with aluminium frame work including fixed to wall complete all as specified and directed.
S&F 12mm thick, prelaminated both side cement bonded particle board are to be of wood finish teak shade and 1st class hard wood (Teak wood beading all around on edging to board including painting to beading, conforming to IS-142-1995, (Bison Panels by NCL group, member indian green building council). The composition of the boards comprises of approximately 60% Cement 30% plantation wood (remaining being other chemical/water binders etc.) with a density of approximately 1250-1300Kg/M3, including fixed with scews to wall, including PVC brackets as necessary required as in shelve, cupboards, wall panelling, cladding etc. including screws and all screw finish with lambi etc. as per specifications. complete all as specified & directed
Taking down 150mm PVC Rainwater pipe/soil pipe including fittings any dia complete all as specified and directed.
S&F 150mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall, including necessary stainless steel clips complete all as specified & directed
S&F 75mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall, floor including necessary stainless steel clips complete all as specified & directed
S&F 75mm dia PVC SWR bends any radius complete all as specified & directed.
E/M WORKS Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials for taking credit and making good disturbed surfaces of walls, floors and roofs etc all as specified and as directed.
Taking down sub main wiring complete including fitting and fixtures, removing materials for taking credit and making good disturbed surfaces of walls, floors, roof etc, all as specified and as directed.
Taking down carefully unserviceable DBs any type/size With MCCBs/MCBs//Isolator etc and disconnecting and making good disturbed surfaces complete all as directed.
M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including modular cover plates with frame and modular flush boxes for mounting for housing the switches, socket outlets, fan regulators etc, all as specified and directed :- (a) One light point controlled by one switch.
(b) One Fan point controlled by one switch and one regulator.
(c) One 3 pin switch socket outlet point 6 Amps on independent board.
(d) One 3 pin switch socket outlet point 6 Amps on same board with other switch.
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.
S & Fix modular switch single pole,one way 6 Amps capacity
S & Fix modular switch single pole, one way 16 Amps capacity
S & Fix modular socket, outlet 2 in 1, 6 Amp capacity
S & Fix modular socket, 6A/16A 2 in1, 16 Amp capacity
S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix modular fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts, 4 step complete all as directed.
S & Fix LED efficient LED recessed mounting fitting 2' X 2' luminaire to enhance the delight of occupents with comfortable experience through its classic design & glare free soft illumination all as specified & directed Make - Bajaj Cat Part No - BZRSQL 36L LED GX D WH SD or eqvt in Wipro/Havell/Crompton.
S & Fix sheet metal enclosure distribution board SPN 8 way 240 volts, 100 amps rated busbar with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed.
S & Fix sheet metal enclosure distribution board SPN 12 ways 240 volts, 100 amps rated busbar with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed.
S & Fix MCB single pole, 240 volts, 6 to 40 Amps, all as specified and as directed.
S & Fix MCB single pole & neutral, 240 volts, 6 to 40 Amps, all as specified and as directed.
M & L for submain wiring with FRLS PVC insulated copper conductor single core cable , multistranded through PVC surface conduit fixed to walls / roofs / floors / ceiling etc with its accessories all as specified and directed by Engr-in -charge for the following. 2x6 sq mm and 1x6 sq mm as earth wire.
S&F Ceiling fan complete with all accessories 230 Volts,1200 mm sweep (white colore),5 star rated complete and includeding suitable size of fan rod, and MS Clamps with all fixing arrangement to ceiling and roof etc all as specifide & directed .make : Havelles, Bajaj and Usha .
S & Fix for ceiling fan down rods 1.0 M Long of 15 mm dia GI pipe to the existing trusses of any height including necessary welding & fixing with clamps and nut bolts etc complete all as specified and as directed.
S & Fix LAN socket connecter RJ 45 with socket with copper feed modular type all as directed by Eng in Chrage.
S & Fix LAN cable 4 pairs PVC insulated and PVC sheathed all as directed by Engr in Charge
S& F PVC conduit 25 mm concealed to walls complete all as specified and directed by Engr- in charge.
PROVN OF CERTAIN B & R WORKS FOR TRG & ADM NAVAL FACULTY S&F 6mm thick Polycarbonate multiwall transparent sheets, fixed to iron/steel frame work with necessary stainless steel screw with washer to wall as per direction of Engr-in-Charge complete.
S&F steel work in tubular trusses, frame work, cantilever, purlin including special shaped washer etc. complete using ERW or induction butt welded square/rectangular pipes including necessary cutting, welding complete all as specified and directed by Engr-in-Charge.
Surface excavation n.exc 30cm deep and average 15cm and getting out in soft/loose soil complete all as specified & directed
M&L for Hardcore of gauge not exc. 63mm, deposited, spread and levelled in layers not exc.15cm thick including watering and ramming upto a true surface complete all as specified & directed
M&L for cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base 75mm thick completecomplete all as specified & directed
M&L for sand cushioning below interlocking paver block complete complete all as specified & directed
M&L for Machine pressed glossy finished rubber moulded coloured precast cement concrete interlocking paver block with pigment and shape, size as approved, conforming to IS 15658-2006 of 60mm thick, M-35 Grade complete all as specified & directed
M&L for precast cement concrete block masonry with solid blocks of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, exc. 10 cm in width and setting in CM 1:6, complete all as specified & directed.
M&L for Rendering 15mm thick on concrete block/ brick or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth without using extra cement, complete all as specified & directed.
Removing of excavated soil to a distance not exc 50mtrs and depositingwhere directed at a level not exc 1.50 mtrs above the starting point complete all as specified and directed by Engr-in-charge.
Excavating in post holes (or similar holes) each n.exc 0.50 cum gettign out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil n.exc 50m and making good the surface in hard/dense soi complete all as specified & directed.
M&L cement concrete in foundation type C 2, 1:3:6 ( 40 mm gde stone aggregate) as in filling and mass concrete complete all as specified & directed.
M&L for mild steel angles as in post and struts in fencing incl cutting tops and shape as directed incl drilling holes, notching for wire etc conforming to Fe-410W (Gde E-250) etc of any description complete all as specified.
Fixing only chain link fencing including line wires, any mesh size and type and type of standards, rails, straining bolts etc including provision of binding wire all as specified.
Supply only MS galvanished chain link fencing with 3 mm dia and size 50 mm x 50 mm including line wires including strain bolts, binding wire etc all as directed.
S&F round bars 10mm dia ( Fe 410 W gde E 250) and over, cut to length, bent to shape required,including binding and welding with mild steel wire (annealed) not less than 0.9mm dia complete all as spd and directed.
S&F mild steel flat iron (Fe-410-0 or Fe – 310 –0) as in bands / straps / rails for chain link fencing cut required length including necessary drilling holes for fixing bolts all as specified and directed.
M&L for mild steel bolt factory made with hexagonal or square heads at one end and screw the other to be fitted with washer etc and one hexagonal or square not exc 5cm long end dia neck 11 to 15mm etc complete all specified and directed by Engr-in-charge.
M&L for preparation of new surfaces & applying Two coats of synthetic enamel paint over a coat of red oxide on steel surfaces exc. 10 cm width or girth etc. complete all as specified & directed
M&L for preparation of new surfaces & applying Two coats of synthetic enamel paint over a coat of red oxide on steel surfaces not exceeding. 10 cm width or girth etc.
PROVN PARKING SHED FOR TWO WHEELER WITH HARDSTANDING P-36 & P-37 (BLDGS) Excavating in post holes ( or similar hoels ) each n exc 0.5 cum getting out, returining, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering, and removing surplus soil to a distance n exc 50 mtr complete all as specified & directed
M&L cement concrete in foundation type d2 1:4:8 ( 40 mm gde stone aggregate) as in filling and mass concrete complete all as specified & directed
Rolled mild steel in plates, channels square cut or notched (ordinary and colour sunk) forming holes, without any attachment conf to Fe 410-W (Gde E-250) quality 'A' complete all as specified & directed
S&F rolled mild steel in joist, channels, angles or tee sections, fixed ,post independently without connecting plates, etc.,conf to Fe 410-W (Gde-E-250) quality 'B'complete all as specified & directed
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240 complete all as specified & directed
M&L for rolled MS work as in wind ties for roofs conforming to Fe-290 W Gde-E-165 complete all as specified and directed.
M&L applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof couring /cladding to wall fixed with self tapping screws complete all as specified and directed..
Surface dressing not exc 15 cm deep and getting out in soft/ loose soil complete all as specified.
M&L PCC in kerb Stone precast (factory made) any shape and size or as directed by engr in charge including weathering, slightly rounded or chamfered angles and throating, in type B-1 1:3:6 (20mm graded agg) set in cement mortar 1:4, complete all as spfd and directed.
Hardcore(Broken boulder) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M & L 75 mm thick PCC (1:4:8) type D2, using 40 mm graded stone aggregate as in sub base surfice finished even and fough to receive floor topping complete all as specified.
Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways of light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour &pattern over and including 50 mm thick compacted bed of fine sand , compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer throug vibratroy compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as spfd and directed.
PROVN OF CERTAIN B&R AND E&M WORKS AT NAVAL FACULTY/ROOM NO B-255 Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as spd and directed
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
M&L precast cement concrete block masonry with solid block, type C-1,1:3:6 mix ( using 20mm graded aggregate ), exc 10cm in width and setting in cement mortar 1:6, complete all as specified and directed.
M & L cement concrete in floor filling 1:5:10 E-2 using 40 mm aggregate for filling in floors complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate finished even and smooth without using extra cement as in floors complete all as specified and directed.
M&L coloured /light shade vetrified ceramic tiles 10mm thick (square/regtangular) polished , area of each tiles not exc 0.36 sqm in floors etc and joineted neat in cement slurry and pointed in white or colour cement to match over 15mm thick screed bed in CM 1:6 .
All as per item No 96 above but on vertical surfaces such as dados, skirtings and risers to steps, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 on stone masonry surfaces.
M&L for rendering 15mm thick on stone masonry surfaces or surfaces other than fair face of brick work in CM 1:6, finishing surfaces even and smooth without using extra cement complete all as specified.
M&L for preparing of new surfaces wall applying two coats of OBD, white or tinted, over 2 mm thick wall care putty and including primer all as directed .
M&L for complete removal or existing wall treatment and applying two coats of OBD over a coat of primer over 2 mm thick ( in two coats) wall care putty finished smooth including preparing the surfaces even and smooth complete all as specified and directed.
Taking down Wooden window/vent with glass all as specified and directed
S&F anodized aluminium powder coated of any colour (thickness of powder coating not less than 50 micron), in frame for window/vent, with one or more rebates including joining cleat for fixing etc ,complete all as specified.
E/M WORKS (BLDG NO B-255) M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including modular cover plates with frame and modular flush boxes for mounting for housing the switches, socket outlets, fan regulators etc, all as specified and directed . (a) One light point controlled by one switch.
(b) One Fan point controlled by one switch and one regulator.
(c) One 3 pin switch socket outlet point 6 Amps on independent board.
(d) One 3 pin switch socket outlet point 6 Amps on same board with other switch.
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.
S & Fix modular switch single pole,one way 6 Amps capacity
S & Fix modular switch single pole, one way 16 Amps capacity
S & Fix modular socket, outlet 2 in 1, 6 Amp capacity
S & Fix modular socket, 6A/16A 2 in1, 16 Amp capacity
S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix modular fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts, 4 step complete all as directed.
S & Fix LED Batten suitable for mount LED tube rod 1 x 18 watts including necessary electric connections with flexible copper cable 23/0.0076 from ceiling rose to tube light fitting complete all as specifed and directed by Engineer-in-charge. Make :- Bajaj Cat Part No - BLRB DB 118 or eqvt in Wipro/Havell/Crompton.
S & Fix LED tube light rod 18 watts with necessary fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make - Bajaj Cat Part No - BLRB 18W LED or eqvt in Wipro/Havell/Crompton.
S & Fix MCB single pole, 240 volts, 6 to 40 Amps, all as specified and as directed.
M & L for submain wiring with FRLS PVC insulated copper conductor single core cable , multistranded through heavy duty PVC concealed conduit fixed to walls / roofs / floors / ceiling etc with its accessories all as specified and directed by Engr-in -charge for the following. 2x4 sq mm and 1x4 sq mm as earth wire complete all as specified & directed
S & Fix Single pole and neutral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs complete all as specified & directed
PAWAN B SHINDE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .