Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹12.7 L+₹2,410.50 (0.19%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹14.4 L
EMD Value
₹28,800
Closing Date
18 May 2020, 6:00 pmClosed
SH MV SANKAR CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIR TO QTR NO P 16B AND P 16D AT NOFRA AT INS MANDOVI UNDER AGE I MANDOVI
2020_MES_338429_1
85246/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
AGE (I) MANDOVI
₹28,800
Yes
4 Sept 2020
11 Apr 2020
21 May 2020
11 Apr 2020
18 May 2020
4 May 2020
Amount
Schedule 'A' Part I - B/R portion
Dismantling/Taking out existing hessian base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to outside of INS Mandovi Area all as specified and as directed.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the mother slab. Filling the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalent) on prepared concrete/plastered surface by diluting 2 parts of Primeseal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating (Dr. Fixint Newcoat/ Waterseal Concentrate of M/s Krishna Conchem Products) without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturer’s instructions.
M&L for 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement. Note :- Integral water proofing compound shall be measured and paid seperately
Taking down cement plaster of stone /PCC block /brick wall / top of chajja, or concrete surface of any description including raking out joints hacking for key securing down with water etc and removal of debris to outside of INS Mandovi Area including filling of open joints in cement mortar 1:6 complete all as specified and as directed.
M & L for 15 mm thick (10+5) rendering in cement mortar 1:4 on fair faces of brick work or concrete surface with WPC as per manufacturer instruction and finished surface even and smooth without using extra cement complete all as specified and as directed
Supply only WPC all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finish even & smooth without using extra cement all as specified and as directed.
M & L for 5 mm thick plastering in cement mortar 1:3 finished even & smooth, without using extra cement on ceiling all as specified and as directed.
Material & Labour for two coats of acrylic emulsion exterior paint (anti fungal paint-APEX or Equivalent) over a coat of acrylic emulsion primer including preparation of new concrete/plastered surface of any description and applying 1 mm wall care putty wherever required all as per manufactures instruction & including necessary scaffolding etc complete all as specified and as directed.
M&L for newly plastered surfaces preparatory to distempering, priming plastered and other surfaces with alkali resistant priming paint, 1mm thick wall care putty & distempering walls with two coats of distemper oil emulsion, white or tinted all as specified and as directed.
M&L for complete removal of existing treatment for preparation of old plastered surfaces preparatory to distempering, priming plastered and other surfaces with alkali resistant priming paint, 1mm thick wall care putty & distempering walls with two coats of distemper oil emulsion, white or tinted all as specified and as directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash all as specified and as directed.
M&L for preparing old plastered surfaces of ceiling and applying one coat of white wash all as specified and as directed.
M&L for applying one coat of acrylic emulsion exterior paint (Anti fungal paint-APEX) on old decorative surface of wall, ceiling cornices including preparation of surfaces by brooming scrapping down dust particle, smoke soot, moulds, moss and efflorescent salts etc all as specified and as directed.
Dismantling PCC floor, hearth or wall tiling including cement mortar bedding, removing serviceable tiles to stores and removing debris to a distance exc 250 m and not exc 1000 m spread and leveled all as specified and as directed.
M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:3 for laying floor finishes for kota stone all as specified and as directed.
M&L for vitrified ceramic tiles light shade 600 x 600 x 10 mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
M&L for non - skid coloured ceramic tiles coloured 7 to 8 mm thick light shade (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:4 on vertical surface as back coat for tiling all as specified and as directed.
M&L for vitrified ceramic tiles light shade 600 x 600 x 10 mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 sqm in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles all as specified and as directed.
M&L for non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
M & L for glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified and as directed.
M & L for machine cut kota stone slab 20-25mm thick laid over cement screed and jointed with cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for granite(of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types all as specified and as directed.
M&L for rounding to edge of stone slab one edge of stone as in cooking platform & staircase tread and other similar works all as specified and as directed.
Taking down chowkats with shutters without taking off shutters from the frames not exc. 1.5 sq m each all as specified and as directed.
Taking down chowkats with shutters without taking off shutters from the frames exc. 1.5 sq m but n exc 4 Sqm each all as specified and as directed.
S & F second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and as directed.
S & F 40mm thick plain, framed, panelled shutters (any number of panels),second class hard wood with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats 40 mm thick all as specified and as directed.
S & F 2nd class gauzed and skeleton shutters 30mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20 (a); supplied and fitted to chowkats all as specified and as directed.
M&L for 2 coats of painting with synthetic enamel paint on new wooden surfaces of any description, not otherwise described, over 10cm width or girth including preparation of new surfaces and a coat of pink primer all as specified and as directed.
M&L for preparation of old painted surfaces of wood and applying one coat of synthetic enamel paint on any description not other described over 10cm width or girth all as specified and as directed.
S&F 100mm X 63 mm size factory made FRP door frame , frame fixed with 3 Nos on either side with MS flat iron 25mmx3mm cut to size & made to shape & fixed as in hold fast after necessary tarring & sanding & fixed as per manufacture instructions & as directed. Thickness of FRP lamination shall be 2mm. Core shall be polyurethane foam/high density (more than 40kg per cubic meter) cellular foam done in situ. Second class wooden blocks shall be provided to hold the fittings .The size of the chowkats shall be inclusive of 2mm thick FRP lamination all as specified and as directed.
S&F factory made paneled FRP door shutter , 30 mm thick with 2 mm FRP lamination top rail of size 30 x 150 mm , lock rail & bottom rail of size 30 x 150 mm with 12 mm thick panels of FRP section of box type construction as per IS 4020 core shall be polyurethane foam / high density ( more than 40 Kg per cubic meter ) cellular foam done in situ & fixed in position as per manufacturer and as directed.
Taking down steel tubing and connections 15 mm bore all as specified and as directed.
Taking down steel tubing and connections 20 mm bore all as specified and as directed.
S & F CPVC 20mm pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
S & F CPVC 25mm pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
S&F Aluminium powder coated window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the JINDAL/HINDAL CO standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S&F powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick complete all as per manufacturer's instructions and as directed.
S&F 4 mm thick sheet glasses panel aluminium window/ventilator, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane all as specified and as directed.
S&F figured glass 4mm thick, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane all as specified and as directed.
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and as directed.
S&F 19 mm dia decorative aluminium anodized alloy curtain rod all as specified and as directed.
S & F 19 mm dia decorative aluminium anodized alloy bracket for holding curtain rod all as specified and as directed.
S & F in repair stop valve of PTMT any colour high pressure screwed for iron pipe (Minimum weight 15mm-90gms) in dia 15 mm pipe all as specified and as directed.
S&F in repairs pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed in repairs.(Minimum weight 15mm-110gms) 15mm bore dia all as specified and as directed.
S & F in repairs bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms)15 mm bore pipe all as specified and as directed.
S & F PVC connection of size 15 mm, 450 mm long with PTMT nuts complete all as specified and as directed.
S&F in repairs PTMT soap dish approximate size 160 x 160 x 90 mm embedded in wall all as specified and as directed.
S&F towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) all as specified and as directed.
S & F in repairs wash basins, vitreous china (flat back white) 550 mm x 400 mm size, including cutting for and pinning in ends of brackets or erecting stand fixing flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern all as specified and as directed.
S & F in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including seat cover all as specified and as directed.
S & F 10 litres capacity PVC valveless,syphonic action type,flushing cistern,low level,white with inlet,ball valve,float and handle including brackets & Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern & fixing High or low level flushing cistern (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and as directed.
S&F in repairs swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) & shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms) all as specified and as directed.
S&F in repairs ball valves 25mm bore dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 25mm-455gms) all as specified and as directed.
S&F 25 mm bore CPVC ball valve all as specified and as directed.
S&F 25 mm CPVC tank adaptor all as specified and as directed.
Taking down eaves gutters, sewage lines and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls all as specified and as directed.
S&F 110 mm dia PVC (SWR) pipe with single socketed in any length solvent cement jointed fixed to wall/column all as specified and as directed.
S&F in repairs 75 mm PVC (SWR) multi floor trap with grating including jointing with solvent cement all as specified and as directed.
S&F 50mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm fixed complete to walls, ceilings or in floors etc all as specified and as directed.
S& F PVC (SWR) bends any radius 110 mm bore with acess door all as specified and as directed.
S& F PVC (SWR) bends any radius 75 mm bore with acess door all as specified and as directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal 110mm bore with acess door all as specified and as directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal 75mm bore with acess door all as specified and as directed.
Demolition of cement concrete of any description in any position not otherwise specifically provided for all as specified and as directed.
M & L for cement concrete 75mm thick cement concrete type C-2 ,1:3:6 using 40mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement all as specified and as directed.
M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes all as specified and as directed.
M & L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors (over plinth protection) with grey cement and no pigments all as specified and as directed.
M&L for chipping , removing carefullly concrete work by low impact hammer ,breaker without damaging the structure & cleaning and disposal of debries outside the premises etc. complete all as specified and as directed. Note : Hard concrete should not be removed by force
M&L for clean existing reinforcement with wire/rotary wire brush, making the surfaces free from loose material dirt etc, complete, applying two coats of alkaline rust converting primer FEOVERT confirming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB complete all as specified and as directed.
M&L for drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes in structural members at the intervals of 500 center to center in staggered manner or as directed by Engineer-In-Charge in RCC structural element. Work shall be carried out as under :- (i) Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles: Insert 12mm dia Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum 12 hrs. (iii) Cutting of nozzles: Cut the nozzles by chisel after completion of grouting without damaging structural elements.
M&L for injecting of site cement slurry grout, in the ratio 1:2 (1- Cement, 2-water) including super plasticizer (Supercom-100) 250 ml/50 Kgs. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled (for repair to wall & slab) all as specified and as directed.
M&L for injecting low viscosity MONOPOL (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including, mixing of materials:mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching.Grouting maintain the pressureat exit(0.5 to 1.0 kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements@ 100ml per nozzle. Repeat the process for all the nozzles (Beam and columns) all as specified and as directed.
M&L for providing and applying jacketing around columns with Micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specified complete all as specified and as directed. Notes:(i) Reinforcement shall be measured and paid separately. (ii) Rates including jacketing, formwork and micro concrete)
M&L for TMT CRS steel bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to TMT all as specified and as directed.
M&L for 5 mm thick rendering in cement mortar 1:4 over gunniting / concrete surface and finished the surfaces even and smooth without using extra cement all as specified and as directed.
S&F 300 mm , brass rat tail rod pattern springs, including roller and roller plate complete all as specified and as directed.
S&F aluminium , anodized barrel tower bolt of extruded section & fixed 200mm long in size all as specified and as directed.
S&F extruded aluminium alloy handles, fabricated type, anodized 200 mm long in size all as specified and as directed.
S&F stainless steel hinge, size 100 mm all as specified and as directed.
S & F floor door stopper 150mm long of aluminium alloy body and fixed to door shutter all as specified and as directed.
S&F mild steel flat iron for hold fast confirming to Fe-290 Grade -E-165 all as specified and as directed.
M&L for PCC 1:3:6 type C 1 using 20mm graded stone aggregate for fixing hold fast all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete for Grade FE 410-0 or FE310-0 all as specified and as directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on the dwarf wall or including fixing cantilever brackets and including all necessary fitting , connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330 mm x 160 mm all as specified and as directed.
S&F in repairs stainless steel plate utensil rack of size 900 X 600 X 1mm thick, 30cm width and fixed to wall surface with necessary bolts complete all as specified and as directed.
Schedule 'A' Part II - E/M portion
Taking down carefully copper / aluminium point wiring ( Light,fan socket or power) complete including fittings and fixtures such as switches,ceiling roses, pendants,regulators, socket, light fitting etc removing material to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc complete all as per the existing finish and as directed.
Taking down DB TPN, main switch,sheet metal enclosures etc all as specified and as directed.
Taking down submain wiring all as specified and as directed.
M&L for point wiring of one light point controlled by one switch with cable 1.5 sqmm copper cable in multistranded unsheathed through concealed in wall with PVC conduit with all accessories including 1.5 sqmm cable conductor for earth wire including making connection with common earth dolly including pressed steel terminal boxes firmly fixed with pipe /wall and 3mm thick Hylem sheet or plastic masonite laminated sheet top cover fixed with brass screw for mounting switches sockets regulator etc all as specified and as directed for light point
All as per item No 96 here in before, but for ceiling/exhaust fan all as specified and as directed.
All as per item No 96 here in before,but for socket 5 Amp all as specified and as directed.
All as per item No 96 here in before, but bell point all as specified and as directed.
All per item No 96 here in before, but 4 sq.mm PVC insulated and unsheathed copper conductor for switch socket combination 3 pin 15 amps on independent board all as specified and as directed.
Supply and fix switch piano,flush type single pole ,one way 5 amp all as specified and as directed.
Supply & fix lamp holder PVC/Polycarbonate type with cord grip cap suitable for pendant fittings all as specified and as directed.
Supply & fix bell buzzer 240Volts all as specified and as directed.
Supply & fix bell push,flush type 5 Amps all as specified and as directed.
Supply and fix switch socket combination 5 pin 5 amp 230 volt 50 HZ AC all as specified and as directed.
S&F switch socket combination 05 pin 15 Amp 230 Volt all as specified and as directed.
S&F LED tube light fitting 1 X 20 watt baton T5 CLASSIC integrated LED chanel integral sleek extruded polycarbonate LED channel with white acrylic cover alongwith LED tube ROD 01 No including flexible wire three core from existing ceiling rose to fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and as directed.
S&F LED tube light fitting 1 X 10 watt baton T5 Mushroom integrated LED channel integral sleek extruded polycarbonate LED channel with white acrylic cover alongwith LED tube ROD 01 No including flexible wire three core from existing ceiling rose to fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and as directed
M&L for taking down and refixing ceiling fan complete including replacement of capacitor, rubber bush, fixing clamp and painting with synthetic enamel paint colour white all as specified and as directed.
S&F MCB 6-32 Amp 240 Volt single pole 'B' series all as specified and as directed.
S&F ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed.
S&F MCB (DB) Vertical (TPN) 4 way double door 415 Volts complete including taking existing old unserviceable all as specified and as directed.
Supply and fix MCB TPN 415 Volts 63 Amps 'B' series all as specified and as directed.
Supply and fix MCB TPN 415 Volts 50 Amps 'B' series all as specified and as directed.
Taking down Exhaust fan Heavy duty Exhaust fan 300mm sweep having 900 rpm single phase ,cleaning,greasing and replacement of capacitor and re- fixing again in same position all as specified and as directed.
M&L for submain wiring with 04 run of 6 sqmm single core copper cable PVC insulated unsheathed multistranded 1100 volt grade drawn through and inculding suitable size of rigid PVC conduit with accessories etc concealed in wall/ceiling with and including two run of 6 sqmm single core copper cable run through rigid PVC concealed in wall from main DB to submain DB trough the meter all as specified and as directed. NOTE :- Four run of 6 sqmm single core cable and 02 run of 6 sqmm single core cable as earthing contnuity conductor with PVC conduit concealed in wall shall be measured as one unit length meter
M&L for submain wiring with 02 run of 4 sqmm single core copper cable PVC insulated unsheathed multistranded 1100 volt grade drawn through and inculding suitable size of rigid PVC conduit with accessories etc concealed in wall/ceiling with and including one run of 4 sqmm single core copper cable run through rigid PVC conduit main DB to submain DB trough the meter all as specified and as directed. NOTE :- Two run of 4 sqmm single core cable and 01 run of 4 sqmm single core cable as earthing contnuity conductor with PVC conduit concealed in wall shall be measured as one unit length meter
Supply and fixing sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly on ground earth pit n. less than 2.25 m deep below the ground bend with top edge of the plate n. less than 1.5m below ground level connected to GI earth wire 4mm by means of bolts,nuts,checks nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber cover and light grade GI pipe 40mm dia for protection of strip and fund etc complete all as per electrical plate No. 3 of SSR Part-I including connections with testing point of lightening protection all as specified and as directed.
Taking down Geyser of 25/50 ltrs capacity single phase ,cleaning, painting complete and changing defective parts (heating element/thermostat of suitable one) and re- fixing again in same position all as specified and as directed.
S&F LED bulbs 9 Watt, retrofit type, warm white complete all as specified and as directed.
M/S NAGINENI RANGA RAO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .