| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.6 L+₹86,148 (4.60%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹18.7 L
EMD Value
₹18,743
Closing Date
8 May 2025, 3:00 pmClosed
Commissioner Madurai Corporation
Aringar Anna Maligai
Maintainance and Repair Works at Moolakarai Mayanam Keerathurai OHT in ward no. 86
2025_MAWS_550982_1
E8/EST- 953/ 24-25
Open Tender
Civil Works
Lump-sum
60 days
Madurai
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹18,743
17 Jun 2025
24 Apr 2025
8 May 2025
24 Apr 2025
8 May 2025
24 Apr 2025
Amount
Picking the existing cement plaster surface
Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
Providing two legged scaffolding using suitable sizes of casurina posts of 1.50cm over all length 3m height + 0.50 lap) The distance between the two rows being 2m and the spacing of posts being 2m in both rows with two horizontal posts with 0.50m.over lap on either side and braces at 2m C/C including longitudinal and transwere middle of 40mm thick and 1m width etc.in complete shape using coir and nails and as directed by the Departmental Officers.
Supply and delivery of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or equivalent grade, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163- 89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 and with 5 years 300mm dia DI D/F Sluice Valve
Supply Of DI Pipe and specials 300mm 4 meter
300mm DI Flange
Providing and laying 1.5 mm thick TPO Membraneover old terrace having weeksurface/Lime mortar. Themembrane is manufactured using hot-melt extrusion process for complete scrim encapsulation. It is reinforced with a strong, polyester reinforced fabric center (scrim) and a tough thermoplastic polyolefin compounded top ply and the bottom. It should have UV resistant top white colour which has a very high resistance to weather agents and UV rays. TPO membrane shall be plasticizer, chlorine & pthalate free, and should exceed /meet specifications of ASTM D6878. Membrane should be mechanically fixed to the substrate by independent plates and fasteners. TPO Roof Membrane should be lapped and seamed using hot air heat welding equipment after mechanically fastening the overlaps. Membrane should have following minimum properties, Breaking Strength min. 220lbf (976N) as per ASTM D751, Elongation break of reinforcement > 15 % as per ASTM D751, and Tear Strength 55lbf (245N) as per ASTM D751. The finished cost including surface preparation, application of TPO membrane over the 200GSM Geotextile and termination of TPO membrane using 2mm thick aluminium strip sealing with PU sealant at the top of strip completely as per specification
Waterproofing: Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface of the UGT/ OHT tank applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation,making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN 1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having antialgae,antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster.The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification
Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch and making good of the concealed portion with suitable colour for PVC concealed light / Fan Point (For electronic regulator) (5 Points Per Coil) SD -20
Supply and fixing of single box type (philips / Havells / Eq) suitable for 4 feet 20W LED tube light with TW round blocks on wall or ceiling with 20W LED tube light with PVC unsheathed Copper leads from terminals to the fitting
Add GST 18%
PITCHAIMANI N (BID ID -1331609)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .