Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance AT DHORI STAFF QTR PO DHORI DIST BOKARO | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 71 BALU BANKER COLONY DHORI BOKARO BOKARO JHARKHAND 825102 | BOKARO | JHARKHAND | 825102 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance ALU BANKER COLONY PO DHORI BERMO DIST BOKARO JHARKHAND | BERMO | BOKARO | JHARKHAND | 825102 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹2,400
Closing Date
19 Oct 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AKHIL UJJWAL,PE (EnM),SDOCM
OFFICE OF THE PROJECT OFFICER,SDOCM,DHORI AREA,CCL
Maintenance of 440v OH line around CISF Barrack A Company, Karipani in r/o SDOCM.
2023_CCL_290629_3
SDOCM/PE(EnM)/eTender/23-24/20 dt.09.10.2023
Open Tender
Electrical and Maintenance Works
Item Wise
10 days
SDOCM
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,400
20 Oct 2023
9 Oct 2023
20 Oct 2023
10 Oct 2023
19 Oct 2023
10 Oct 2023
10 Oct 2023 - 19 Oct 2023
Amount
Supply and providing of PCC pole 10 mtr long
Erection of RCC/PCC pole of following length in cement concrete 1:3:6(1cement:3coarse sand: 6graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.Above 10.00 metre and upto 12.00 metre
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.40x7x3=840mtrx0.214kg=179.76kg
Supply of 8 SWG GI wire for earth continuity & cradling 7 span x 40 x 3x0.132
Erection of cradle guard 07 span x 32 Nos
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X45cmX7.5mm,thimble,stayclamps,turnbuckle(20mmX60 cm),7/4.00mmdiaG.I.staywireandstraininsulatoretcincement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. asrequired.
Supplying and erection of100mmX80mm pin insulator complete with G. I. Spindle and nuts etc. as required.
Supplying and erectionof100mmX110mm shackle insulator with G. I. Bolt, nuts and straps etc. as required.
Supply and erection of Nut , bolt & clamp
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Dismantling of overhead lines comprising of copper/aluminum overhead conductor, G.I. wire, cross arms, insulators etc. as required
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket form outing of fluorescent/HPMV/HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Erection of angle iron/channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of1m above ground level and removal of rubbish upto a distance of50 m outside the periphery of the area cleared.
Fresh Jumpring
Transporting of pole
Supplying and ercting earth pit of minimum bore dia 150mm size approved make safe earthing electode consisting pipe in pipe technology as per IS3043-1987 made of corrosion free GI pipe with constant ohmic value surrounded byhighly conductive compound with high charge dissipation suitable for effective and maintenance free earthing as mentioned with 3 mtr GI pipe having outer dia of 50mm having 80-200 micron galvanized inner pipe dia of 25mm having 200-250 micron galvanizing coonnection terminal dia of 112mm in nominal soil with 50kg ( Two bag) back filling compound
Total impact of GST for the purpose of CTC
M/S UPENDRA ELECTRICAL
M/S NATIONAL ELECTRICAL WORKS
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .