GEMC-511687781719788
Awarded to MACRO SCIENTIFIC WORKS PRIVATE LIMITED
₹74,880
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Bacterological incubator-LED-DIGITAL | MAC-IUD-HR-10-BODI-280L | - | 1 NOS | ₹74,880 | 74,880 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹74,880Qualified Make: macroscientificworks
Model: MAC-IUD-HR-10-BODI-280L 10A UA JAWAHAR NAGAR DELHI NEAR MALKA GANJ CHOWK CHANDRAWAL ROAD DELHI DELHI DELHI 110007 | NORTH DELHI | DELHI | 110007 | Make: macroscientificworks
Model: MAC-IUD-HR-10-BODI-280L | L1 | Qualified | |
| 2 | L2₹82,989+₹8,109 (10.8%)Qualified Make: NA
Model: ICON-IIC 109 B 16 90 2ND FLOOR SUBHASH NAGAR NEW DELHI WEST DELHI DELHI 110027 | WEST DELHI | DELHI | 110027 | Make: NA
Model: ICON-IIC 109 B | L2 | Qualified | |
| 3 | Disqualified Make: ACCUMAX
Model: AI-109 105 FIRST FLOOR VISHAL TOWER DISTRICT CENTRE JANAKPURI JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0022043 07ASXPS7874B1ZX R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110058 | Make: ACCUMAX
Model: AI-109 | - | Disqualified | |
| 4 | Disqualified Make: PHOENIX
Model: Phoenix / NWS101 with BAS100 32 N4 JAWARHARLAL NERHU SALAI EKKADUTHANGAL CHENNAI TAMIL NADU 600032 | CHENNAI | TAMIL NADU | 600032 | Make: PHOENIX
Model: Phoenix / NWS101 with BAS100 | - | Disqualified | |
| 5 | Disqualified Make: EIE
Model: EIE 201 1001 1002 SPAN TRADE CENTER OPP KOCHRAB ASHRAM PALDI AHMEDABAD GUJARAT 380006 | AHMADABAD | GUJARAT | 380006 | Make: EIE
Model: EIE 201 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
2 Aug 2018, 5:00 pmClosed
Clinical incubators or infant warmers Average Turn Over of Last 3 Years 3 Lakh (s) Experience with Gov. Required 3 Year (s) Clinical Incubators Or Infant Warmers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Definition and Clinical Purpose Definition Mains electricity (AC- powered) mobile device that contains an infrared (IR) heating element(s) designed to emit controlled
evenly distributed overhead heat to the body of a newborn/infant patient requiring supplemental heat. This device is equipped with wheels so that it can easily be moved to different areas of a room
ward
or department. - Clinical purpose &Overview of functional requirements It is an electrically powered device with a radiant heating source intended to maintain the thermal balance of an infant by direct radiation of energy in the infrared region of the electromagnetic - 1/8 spectrum. It is a microprocessor controlled unit with heater placed on the over head panel. This work on both servo and manual mode options to maintain the baby temperature at the set value. There are two modes of operation manual and baby (servo) mode. It has Digital displays reading the set and baby observed temperatures seperately. Technical Characteristics (specific to this type of device) facility to display skin set
skin observed temperature in degree C and heat power separately false - have user friendly touch panel control Yes - Type of heater: ceramic ceramic Audiovisual alarm facility for: Overheating beyond set temperature range Overheating beyond set temperature range Warmer head should be rotatable in different direction
so as to allow taking X-ray false Observation light Luminance and Colour temperature > = 1000 Lux
Colour temperature range from 3700K to 5100K - Battery back up facility for Power failure indication during power fail Yes - desired temperature range 25 to 40 degree C - setable temperature 32 to 38 deg C 32 to 38 deg C - temperature resolution should be: <= 0.1 degree C - Temperature accuracy should be <= 0.2 degree C - facility to lock the keyboard to avoid unwanted user modification of the set Yes - 2/8 parameters should have separate Bassinet trolley
bed should be tilt-able and have suitable provision for x-ray cassette holder
Mattress foam density should be minimum 25 kg/cm3
transparent collapsible side walls easily detachable for cleaning Yes - Should have a Feather Touch operation with large digital display and comprehensive alarms
Control Panel should be liquid proof and allow easy and hygienic disinfection Yes - Manual Mode can adjust Heater Output 10 -100 %
with 10% increment
an auditory and visual alarm shall be given at least every 15 min Yes - Under manual mode
heater cut off/switch off
if the maximum irradiance at any point of the mattress area exceeds a total irradiance level of 10 mW/cm2 (between 10 to 30 minutes) Yes - Bed height from Floor - - Bed Distance from the heat source - - should have lockable castor wheels Yes - Green indicator light shall be indicate that warmer is ready for normal use Yes - Markings on the bassinet and X-Ray cassette holder to enable proper positioning of the baby while doing the X-Ray Yes - Number of tubing ports 2 - 3/8 (edges covered by silicon rings) on the side walls (For cable management) Height of the side walls over the mattress 800 - Provision of X-Ray cassette tray of at least 750 mm X 350 mm size
suitable to adopt <= 20mm thick X-Ray cassette Yes - bay bed should be crevice free for ease of cleaning
infection control Yes - mattress used should be of biocompatible material Yes - Skin temperature probe should be small in size [Diameter <= 10 mm & Height <= 4 mm] with biocompatible Baby contact material Yes - Mobility
portability On castors (2 of the castors should have brakes) & Castor size >= 4 inch. - Settings Settings with facility to clearly display the selected mode
Option of Selecting either Manual mode and Baby (Servo) mode settings
Provision for Set temperature range (in servo mode) from 32 to 38 deg C Yes - User's interface Manual and Servo controlled temperature regulation - Software and/or standard of communication(where ever required) LED Display and inbuilt software; Interruption and restoration of the power supply does not change the preset values - Others: 1. Device shall not overbalance when placed in any transport position of normal use - 4/8 on a 10° inclined plane from the horizontal plane. 2. Transformers of devcie shall be protected against overheating in the event of short circuit or overload of any output winding. 3. Patient leakage current should be less than 100 μA in normal condition 4. Temperature on the baby mattress should not exceed 43 deg C when the warmer is operating under steady temperature condition 5. Temperature of HEATER GUARDS should not exceed 85 °C in normal use. 6. The Temperature differences on the mattress shall not exceed 2 °C. PHYSICAL CHARACTERISTICS Overall Height of equipment 875 - Overall Width of equipment - - Overall Length of equipment - - Overall weight of equipment - - Heat source Configuration >= 60 degree angle adjustment must be possible in the heat source
it should provide shielding to the infant in case of breakage of tubes/bulbs and all surfaces to be made of corrosion resistant material - Noise Auditory alarm shall have a sound level of at least 65 dBA at a distance of 3 m from the front of the infant radiant warmer
and the sound level of the alarm shall not exceed 80 dBA on the mattress - 5/8 Heat dissipation Should maintain desired set temperature and uniform heat distribution in baby cradle - ENERGY SOURCE Power Requirements 220 to 240V
50 Hz AC
± 10% of input - Battery operated Power failure indication during power fail - Protection OVP
earth leakage protection - Power consumption 250 - Compatible to alternate energy supply source; Solar Heating in addition to AC power source): false Thermal reflector to fix the skin probe >= 50 units to be supplied with each equipment unit - ENVIRONMENTAL AND DEPARTMENTAL CONSIDERATIONS Atmosphere Ambiance Operating condition: -Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances. - an ambient air velocity is less than 0.3 m/s. - User's care
Cleaning
Disinfection & Sterility issues Complete unit to be easily washable and sterilizable using both alcohol and chlorine agents. - STANDARDS AND SAFETY Certificates
US FDA - Performance and safety standards (specific to the device type); Local and/or international IEC-60601-1-2:2007 Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility -Requirements and tests (Or Equivalent BIS). Shall neet IEC 60601 -2- 21: 2009 Medical Electrical Equipment - Part 2¬21: - 6/8 Particular Requirement for the basic safety and essential performance of infant radiant warmers . should meet IEC 60601-1:2005(or latest) standard requirements. Baby contact material should be biocompatible. Manufacturer should be ISO 13485 certified Availability of Type Test report from any Govt/NABL accredited iLAC approved laboratory (To be produced by Seller on Buyer's demand if indicated available) false - TRAINING AND INSTALLATION Pre-installation requirements for the equipment Availability of 5 amp/15 Amp. Electrical socket (2 nos) for each warmer at Buyer's facility. - Documentation required to be provided by Seller: User & Operating manual
Certificate of Calibration
Factory inspection report
user training manual - WARRANTY Warranty Scope Shall be onsite and comprehensive i.e. with free service and spares - Warranty period for equipment(Other than nickel chrome wire filament and tube of quartz
that shall have lifetime warranty) 3 3.0 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 LK Thakur 122016
Sector-20
Udyog Vihar
Opp. Ambience Mall 1 15
388483
GEM/2018/B/54995
GeM Contract
Clinical incubators or infant warmers
GeM Contract
15 days
Haryana; Gurugram
PRODUCT
Awarded to MACRO SCIENTIFIC WORKS PRIVATE LIMITED
₹74,880
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Bacterological incubator-LED-DIGITAL | MAC-IUD-HR-10-BODI-280L | - | 1 NOS | ₹74,880 | 74,880 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Clinical incubators or infant warmers Average Turn Over of Last 3 Years 3 Lakh (s) Experience with Gov. Required 3 Year (s) Clinical Incubators Or Infant Warmers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Definition and Clinical Purpose Definition Mains electricity (AC- powered) mobile device that contains an infrared (IR) heating element(s) designed to emit controlled | - | - | - |
| evenly distributed overhead heat to the body of a newborn/infant patient requiring supplemental heat. This device is equipped with wheels so that it can easily be moved to different areas of a room | - | - | - |
| ward | - | - | - |
| or department. - Clinical purpose &Overview of functional requirements It is an electrically powered device with a radiant heating source intended to maintain the thermal balance of an infant by direct radiation of energy in the infrared region of the electromagnetic - 1/8 spectrum. It is a microprocessor controlled unit with heater placed on the over head panel. This work on both servo and manual mode options to maintain the baby temperature at the set value. There are two modes of operation manual and baby (servo) mode. It has Digital displays reading the set and baby observed temperatures seperately. Technical Characteristics (specific to this type of device) facility to display skin set | - | - | - |
| skin observed temperature in degree C and heat power separately false - have user friendly touch panel control Yes - Type of heater: ceramic ceramic Audiovisual alarm facility for: Overheating beyond set temperature range Overheating beyond set temperature range Warmer head should be rotatable in different direction | - | - | - |
| so as to allow taking X-ray false Observation light Luminance and Colour temperature > = 1000 Lux | - | - | - |
| Colour temperature range from 3700K to 5100K - Battery back up facility for Power failure indication during power fail Yes - desired temperature range 25 to 40 degree C - setable temperature 32 to 38 deg C 32 to 38 deg C - temperature resolution should be: <= 0.1 degree C - Temperature accuracy should be <= 0.2 degree C - facility to lock the keyboard to avoid unwanted user modification of the set Yes - 2/8 parameters should have separate Bassinet trolley | - | - | - |
| bed should be tilt-able and have suitable provision for x-ray cassette holder | - | - | - |
| Mattress foam density should be minimum 25 kg/cm3 | - | - | - |
| transparent collapsible side walls easily detachable for cleaning Yes - Should have a Feather Touch operation with large digital display and comprehensive alarms | - | - | - |
| Control Panel should be liquid proof and allow easy and hygienic disinfection Yes - Manual Mode can adjust Heater Output 10 -100 % | - | - | - |
| with 10% increment | - | - | - |
| an auditory and visual alarm shall be given at least every 15 min Yes - Under manual mode | - | - | - |
| heater cut off/switch off | - | - | - |
| if the maximum irradiance at any point of the mattress area exceeds a total irradiance level of 10 mW/cm2 (between 10 to 30 minutes) Yes - Bed height from Floor - - Bed Distance from the heat source - - should have lockable castor wheels Yes - Green indicator light shall be indicate that warmer is ready for normal use Yes - Markings on the bassinet and X-Ray cassette holder to enable proper positioning of the baby while doing the X-Ray Yes - Number of tubing ports 2 - 3/8 (edges covered by silicon rings) on the side walls (For cable management) Height of the side walls over the mattress 800 - Provision of X-Ray cassette tray of at least 750 mm X 350 mm size | - | - | - |
| suitable to adopt <= 20mm thick X-Ray cassette Yes - bay bed should be crevice free for ease of cleaning | - | - | - |
| infection control Yes - mattress used should be of biocompatible material Yes - Skin temperature probe should be small in size [Diameter <= 10 mm & Height <= 4 mm] with biocompatible Baby contact material Yes - Mobility | - | - | - |
| portability On castors (2 of the castors should have brakes) & Castor size >= 4 inch. - Settings Settings with facility to clearly display the selected mode | - | - | - |
| Option of Selecting either Manual mode and Baby (Servo) mode settings | - | - | - |
| Provision for Set temperature range (in servo mode) from 32 to 38 deg C Yes - User's interface Manual and Servo controlled temperature regulation - Software and/or standard of communication(where ever required) LED Display and inbuilt software; Interruption and restoration of the power supply does not change the preset values - Others: 1. Device shall not overbalance when placed in any transport position of normal use - 4/8 on a 10° inclined plane from the horizontal plane. 2. Transformers of devcie shall be protected against overheating in the event of short circuit or overload of any output winding. 3. Patient leakage current should be less than 100 μA in normal condition 4. Temperature on the baby mattress should not exceed 43 deg C when the warmer is operating under steady temperature condition 5. Temperature of HEATER GUARDS should not exceed 85 °C in normal use. 6. The Temperature differences on the mattress shall not exceed 2 °C. PHYSICAL CHARACTERISTICS Overall Height of equipment 875 - Overall Width of equipment - - Overall Length of equipment - - Overall weight of equipment - - Heat source Configuration >= 60 degree angle adjustment must be possible in the heat source | - | - | - |
| it should provide shielding to the infant in case of breakage of tubes/bulbs and all surfaces to be made of corrosion resistant material - Noise Auditory alarm shall have a sound level of at least 65 dBA at a distance of 3 m from the front of the infant radiant warmer | - | - | - |
| and the sound level of the alarm shall not exceed 80 dBA on the mattress - 5/8 Heat dissipation Should maintain desired set temperature and uniform heat distribution in baby cradle - ENERGY SOURCE Power Requirements 220 to 240V | - | - | - |
| 50 Hz AC | - | - | - |
| ± 10% of input - Battery operated Power failure indication during power fail - Protection OVP | - | - | - |
| earth leakage protection - Power consumption 250 - Compatible to alternate energy supply source; Solar Heating in addition to AC power source): false Thermal reflector to fix the skin probe >= 50 units to be supplied with each equipment unit - ENVIRONMENTAL AND DEPARTMENTAL CONSIDERATIONS Atmosphere Ambiance Operating condition: -Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances. - an ambient air velocity is less than 0.3 m/s. - User's care | - | - | - |
| Cleaning | - | - | - |
| Disinfection & Sterility issues Complete unit to be easily washable and sterilizable using both alcohol and chlorine agents. - STANDARDS AND SAFETY Certificates | - | - | - |
| US FDA - Performance and safety standards (specific to the device type); Local and/or international IEC-60601-1-2:2007 Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility -Requirements and tests (Or Equivalent BIS). Shall neet IEC 60601 -2- 21: 2009 Medical Electrical Equipment - Part 2¬21: - 6/8 Particular Requirement for the basic safety and essential performance of infant radiant warmers . should meet IEC 60601-1:2005(or latest) standard requirements. Baby contact material should be biocompatible. Manufacturer should be ISO 13485 certified Availability of Type Test report from any Govt/NABL accredited iLAC approved laboratory (To be produced by Seller on Buyer's demand if indicated available) false - TRAINING AND INSTALLATION Pre-installation requirements for the equipment Availability of 5 amp/15 Amp. Electrical socket (2 nos) for each warmer at Buyer's facility. - Documentation required to be provided by Seller: User & Operating manual | - | - | - |
| Certificate of Calibration | - | - | - |
| Factory inspection report | - | - | - |
| user training manual - WARRANTY Warranty Scope Shall be onsite and comprehensive i.e. with free service and spares - Warranty period for equipment(Other than nickel chrome wire filament and tube of quartz | - | - | - |
| that shall have lifetime warranty) 3 3.0 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 LK Thakur 122016 | - | - | - |
| Sector-20 | - | - | - |
| Udyog Vihar | - | - | - |
| Opp. Ambience Mall 1 15 | - | - | - |
Exempted
24 Aug 2018
26 Jul 2018
contract_GEMC-511687781719788.pdf
GEM_CONTRACT • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_388483.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .