Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.8 LAccepted-Finance | L-1 | Accepted-Finance L1 Bidder | |
| 2 | L-2₹1.8 L+₹2,642 (1.50%)Accepted-Finance | L-2 | Accepted-Finance L2 Bidder |
| Sl No | Description | Qty | Unit | K SRINIVASA RAO L1 | P Purushshotham L2 |
|---|---|---|---|---|---|
| 1.00 | Attending breakdown call and restoring the power supply from RNGD TE Building to STR TE building including checking the old existing cable and reconnecting the new temperory cable etc., as required. | 1 | Job | 2,625 ₹2,625 Lowest | 3,000 ₹3,000 |
| 2.00 | Decommissioning of the existing LT panel in STR building (App size 2mtr x 1.5mtr x 30 cm deep) by removing all the incoming and outgoing cables (Approx 2 incomings and 8 out going cables) along with end terminations etc., as required. | 1 | Job | 6,300 ₹6,300 Lowest | 6,300 ₹6,300 Lowest |
| 3.00 | Dismantling, shifting of existing 4 Way TPN MCB DB from STR building to BTS room, Re-installation of the same in BTS room & extending all the required cables from BTS room to pump set and DE room lighting etc., as required. | 1 | Job | 2,625 ₹2,625 Lowest | 3,000 ₹3,000 |
| 4.00 | Supply and Laying of following size PVC insulated PVC sheathed Aluminum Armoured UG cable on wall /surface with suitable clamping from Panel to power plant or panel to DBs etc as required. a) 3.5 Core x 25 sqmm | 150 | Mtrs | 400 ₹60,000 Lowest | 400 ₹60,000 Lowest |
| 5.00 | Supplying and fixing following way, vertical type Three pole and neutral, sheet steel, MCB distribution board with MCCB as incomer, 415 volts, on surface/ recess, complete with 250Amps tinned copper bus bar, neutral bus bars, earth bars, din bar, interconnections, powder painted including Earthing etc., complete as required. (But without MCB/RCCB/Isolator) a) 6 Way (DPX³ 160+18 Way) TPN vertical typeMCB DB, double door (Legrand Cat No. 5077 46) | 1 | Nos | 20,800 ₹20,800 Lowest | 21,000 ₹21,000 |
| 6.00 | b) 160 A, 3 Pole MCCB with 36 kA Breaking Capacity (Legrand Cat No. 4200 85) | 1 | Nos | 10,800 ₹10,800 Lowest | 11,000 ₹11,000 |
| 7.00 | c) 63A TP MCB (Legrand Cat No. 4086 61) | 4 | Nos | 3,050 ₹12,200 | 3,000 ₹12,000 Lowest |
| 8.00 | d) 6/16/20A SP MCBs (Legrand Cat No. 4085 67/92/93) | 6 | Nos | 400 ₹2,400 Lowest | 400 ₹2,400 Lowest |
| 9.00 | Supplying and laying of 2 runs of 2 core 16sq mm. PVC insulated weather proof multi strand aluminium conductor outer sheath of 1.1KV grade on surface / existing cable tray with 2runs of 14 SWG GI wire, locking tags in the existing pipe/on surface of wall/ floor with clamps including liasoning with Electricity board authorities, etc. as required. (ISI make) | 100 | Mtrs | 335 ₹33,500 Lowest | 350 ₹35,000 |
Tender Value
₹1.7 L
EMD Value
₹3,365
Closing Date
22 Sept 2025, 3:00 pmClosed
EE(EP-MM) BEZH
O/o Sr. Chief Engineer (Electrical) BSNL Electrical Zone, Room no- 601, 6th Floor, BSNL Bhavan, Adarsh Nagar, Hyderabad
Dismantling of LT panel at STR Building, Supplying of Laying of new cable, Vertical TPN MCB DBs in STR TE building at RNGD TE bldg in Nalgonda OA
2025_BSNL_248417_1
47/EE(EP-MM)/CEE/BEZH/ 2025-26 dated 11.09.2025
Open Tender
Electrical Works
Item Rate
30 days
Nalgonda
Please refer Tender documents.
14 documents required · 14 mandatory
₹590
AO (Cash), BSNL, office of CGMT, Telangana Circle
₹3,365
12 Nov 2025
11 Sept 2025
23 Sept 2025
11 Sept 2025
22 Sept 2025
11 Sept 2025
11 Sept 2025 - 20 Sept 2025
Amount
Attending breakdown call and restoring the power supply from RNGD TE Building to STR TE building including checking the old existing cable and reconnecting the new temperory cable etc., as required.
Decommissioning of the existing LT panel in STR building (App size 2mtr x 1.5mtr x 30 cm deep) by removing all the incoming and outgoing cables (Approx 2 incomings and 8 out going cables) along with end terminations etc., as required.
Dismantling, shifting of existing 4 Way TPN MCB DB from STR building to BTS room, Re-installation of the same in BTS room & extending all the required cables from BTS room to pump set and DE room lighting etc., as required.
Supply and Laying of following size PVC insulated PVC sheathed Aluminum Armoured UG cable on wall /surface with suitable clamping from Panel to power plant or panel to DBs etc as required. a) 3.5 Core x 25 sqmm
Supplying and fixing following way, vertical type Three pole and neutral, sheet steel, MCB distribution board with MCCB as incomer, 415 volts, on surface/ recess, complete with 250Amps tinned copper bus bar, neutral bus bars, earth bars, din bar, interconnections, powder painted including Earthing etc., complete as required. (But without MCB/RCCB/Isolator) a) 6 Way (DPX³ 160+18 Way) TPN vertical typeMCB DB, double door (Legrand Cat No. 5077 46)
b) 160 A, 3 Pole MCCB with 36 kA Breaking Capacity (Legrand Cat No. 4200 85)
c) 63A TP MCB (Legrand Cat No. 4086 61)
d) 6/16/20A SP MCBs (Legrand Cat No. 4085 67/92/93)
Supplying and laying of 2 runs of 2 core 16sq mm. PVC insulated weather proof multi strand aluminium conductor outer sheath of 1.1KV grade on surface / existing cable tray with 2runs of 14 SWG GI wire, locking tags in the existing pipe/on surface of wall/ floor with clamps including liasoning with Electricity board authorities, etc. as required. (ISI make)
P Purushshotham (BID ID -904268)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .