Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹18.6 L+₹1,025 (0.06%)Rejected-Finance | L2 | Rejected-Finance Other than L1 after deducting sch of credit Rs 78570 | |
| 3 | L3₹20.2 L+₹1.6 L (8.76%)Rejected-Finance | L3 | Rejected-Finance Other than L1 after deducting sch of credit Rs 78570 |
Tender Value
₹22.5 L
EMD Value
₹45,000
Closing Date
28 Sept 2022, 6:00 pmClosed
GE NORTH AKHNOOR
GE NORTH AKHNOOR PIN 181201 CO 56 APO
COMPREHENSIVE REPAIR MAINT OF LIGHTENING CONDUCTORS EARTHINGS INCLUDING OVERHEAD UG SUMP CLEANING OF TANKS WATER LEVEL INDICATORS CONNECTED CABLES GLOW SIGN BOARDS AND CONNECTED ITEMS AT AKHNOOR UNDER GE N AKHNOOR
2022_MES_548973_1
GE(N)/AKH-53/2022-23
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
Class E Cat b i
8 documents required · 8 mandatory
₹500
Yes
GE NORTH AKHNOOR
₹45,000
Yes
6 Dec 2022
31 Aug 2022
30 Sept 2022
31 Aug 2022
28 Sept 2022
14 Sept 2022
Amount
Cleaning of internal wall/floors of RCC over head reservoirs of Capacity 25000 Gallon including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste by opening wash out valves and applying caustic soda solution and one coat of lime wash internally including cement base white wash of complete OH tank external wall, bottom surface, pillar and painting of raising main pipe line and delievery line by black paint and writing work with one coat of synthetic enameled paint as per colour code for (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank etc, complete all as specified and as directed. NOTE : for srl item No 1 to6 ,All precautionery measure such as safety belt, climbing rope etc to be taken by the contractor for safeguard of human life while working on overhead reservoir.
Cleaning of internal wall/floors of RCC over head reservoirs of Capacity 50000 Gallon including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste by opening wash out valves and applying caustic soda solution and one coat of lime wash internally including cement base white wash of complete OH tank external wall, bottom surface, pillar and painting of raising main pipe line and delievery line by black paint and writing work with one coat of synthetic enameled paint as per colour code for (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank etc, complete all as specified and as directed.
Cleaning of internal wall/floors of RCC over head reservoirs of Capacity 100000 Gallon including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste by opening wash out valves and applying caustic soda solution and one coat of lime wash internally including cement base white wash of complete OH tank external wall, bottom surface, pillar and painting of raising main pipe line and delievery line by black paint and writing work with one coat of synthetic enameled paint as per colour code for (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank etc, complete all as specified and as directed.
Cleaning of internal walls for underground or semi underground sump located at Stage III and Stage IV, Pump House of Capacity 50000 Gallons. The work also includes washing with clean water and bleaching powder including scraping with wire brush on walls and floors & removing mud and grits & deposits etc throw out propeprly to a distance not exceeding 50 Mtr. including cement base white washing of external wall and painting of raising main pipe line and delievery line by black paint and Writing the date of cleaning and due date of cleaning on a rectangular box of size 75cm x 50cm, wriing in white in colour on black back all as specified and as directed.
Cleaning of internal walls for underground or semi underground sump located at Stage I and Stage II, Pump House of Capacity 100000 Gallons. The work also includes washing with clean water and bleaching powder including scraping with wire brush on walls and floors & removing mud and grits & deposits etc throw out propeprly to a distance not exceeding 50 Mtr. including cement base white washing of external wall and painting of raising main pipe line and delievery line by black paint and Writing the date of cleaning and due date of cleaning on a rectangular box of size 75cm x 50cm, wriing in white in colour on black back all as specified and as directed.
Cleaning of internal walls for underground or semi underground sump located at Stage II, Pump House of Capacity 200000 Gallons. The work also includes washing with clean water and bleaching powder including scraping with wire brush on walls and floors & removing mud and grits & deposits etc throw out propeprly to a distance not exceeding 50 Mtr. including cement base white washing of external wall and painting of raising main pipe line and delievery line by black paint and Writing the date of cleaning and due date of cleaning on a rectangular box of size 75cm x 50cm, wriing in white in colour on black back all as specified and as directed.
M&L for Chlorine testing kit compete with test tubes, solution complete all as specified and directed by Eng-in-Charge.
Testing of water by the approved govt lab authority’ and test the following perameter of water :- PH range, Total solids, total hardness, Floride, Nitrites, Nitrates, Lead Arsenic, Ammonia, Chlorides, Cadmium, Cyanide, Mercury Iron, Management, Surphate, Phernolic and submission the report to Deptt or as directed by Engr-in-charge Note :- Water collected on presence of medical staff / MES staff and empty collection sample bottle will be provided by the contractor
Supply & fixing Aviation obstruction light for overhead water storage tank or reservoir with LED lamp 1 watt of 100 Nos complete all as specified and directed by Engr-in-charge. Make: C&S Model No. LTAL100 of C&S or equivalent in Philips/Bajaj
M & L for Fabrication of distribution header of size 250 mm dia MS pipe, min length -5 mtr , dead end from both side with blind plates duly bolted including welding work to cut pieces/ pipes made to shape for taking out number of incoming / Outgoing branches flanged type as given below with suitable sluice valves incl nuts bolts, washer, welding, bending, drilling holes for bolts in any shape or size as directed inclusive of one primer coat, one under coat and finish coat of paint as per existing complete including brick work with plastering 15mm thick in 1:6 cement mortar to support the header above ground level and necessary PCC work in 1:2:4 type B1 / hard standing all around complete all as specified and directed. (Contractor must visit the site before quoting). Note : Sluice valve shall be paid under seperate relevant items.Rate for made to flanges, Tee, Elbow fitting etc are included in the quoted rates. (a) Nos of Incoming- 01Nos, size- 150mm outlet (b) Nos of Outcoming- 04 Nos, size- 150mm outlet (c) Nos of Outcoming- 01 Nos, size- 100mm outlet
Supply and fixing in replacement sluice valve size 80mm cast iron ISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it, class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation , packing rings, joiniting materials nuts,bolts, washers , gaskets and packings material all as specified and directed . Make BVI,BIR,Kirloskar
Supply and fixing in replacement sluice valve size 100mm cast iron ISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it, class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation , packing rings, joiniting materials nuts,bolts, washers , gaskets and packings material all as specified and directed . Make BVI,BIR,Kirloskar
Supply and fixing in replacement sluice valve size 150mm cast iron ISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it, class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation , packing rings, joiniting materials nuts,bolts, washers , gaskets and packings material all as specified and directed . Make :BVI,BIR,Kirloskar
Supply and fixing in replacement sluice valve size 200mm cast iron ISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it, class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation , packing rings, joiniting materials nuts,bolts, washers , gaskets and packings material all as specified and directed . Make: BVI,BIR,Kirloskar
Supply and fixing in replacement non return valve 150 mm dia heavy duty both ends flanged ISI marked,class PN 1.6 complete with nuts, bolts washers etc complete all as specified and directed by Engr-in-charge . Make : BVI,BIR,Kirloskar
Supply and fixing in replacement non return valve 100 mm dia heavy duty both ends flanged ISI marked,class PN 1.6 complete with nuts, bolts washers etc complete all as specified and directed by Engr-in-charge . Make : BVI,BIR,Kirloskar
Supply only chlorination chemical highly efficient (high strength) calcium based granular(65 to 70% chlorine content) disinfectant more stable than chlorine gas/bleaching powder high stable in sealed container for water treatment stability projected shelf life of chlorination of chemical must be one year with min loss of chlorine MakeDeclibag Tech pvt ltd/ Aquafir or equivalent approved by Einc Branch. Note:- The contractor has to produce manufacture/all india MES distributor test certificate and purchase voucher from authrozied dealer/company while supply of calcium based granual for the verification of genuanity of material.No material is accepted without test certificate.
Supply and fixing in replacement “Lithium based Energy Efficient Integrated Solar Street Light of 20Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 44/46Wp , Lithium Battery 11.1/12.8V, 24.2AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower lightl evel with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 10-12kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required.Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of Make:- Axxon (AXN-20W) or equivalent in Bajaj /phillips/Halonix
Material and labour for painting and writing letters "SAVE WATER" in Black letter size 36"X18" on dome of over head water RCC tank and UG Sump , writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 80 mm size on external surface of wall with white enamel paint over black background of any capacity over head tank and UG Sump all as directed Engr-in-charge
M&L for smart water level controller with sensor integrated via screw terminals with th on field configuration for providing the option for underground sump and overhead tank each. Indication for 5 sensor reading per tank each.( 0%, 25%,50%,75%,100%) display interface with 4.3'' TFT LCD Screen with 32 bit micro controller unit , fixed resolution 480x 720 pixels operating temp for device 20 to 70 deg celsius. The controller must support I/O based controls over 8 bit8051 base microcontroller unit with support for buzzer/Alarm at 25% and 100% capacity to operate ON/OFF operations manual overide option to overide the controls from auto mode. The enclousre is made of ABS material for IP protection Make : Satya sai or equivalent
M&L for SS304 Horizontal magnetic float switch with SS pipe for sensor mounting (5 Nos sensor) all as specified and directed.
M&L for 7 core copper alloy signal cable with weather proof rubber coating all as specified and directed.
Supply and fixing Glow sign board made of acrylic sheet reactangular shape having lighting arrangement of superior quality of size 5'x2'x8" showing installation Nomenclature as approved marked all as specified and directed. Note: Installation line diagram to be enfaced will be approved by AGE E/M and no extra will be paid of any addition and alteration of words or marking of colours.
Fabrication of angle stand made of angle size 50x50x6mm for Glow sign board, incl jointing of Tees,incl PCC all as specified and directed.
Disconnecting , dismantling and taking down carefully single pointed air termination aluminium rod incl GI pipe of any size incl nuts bolts and segregation unsv or ser parts incl removing from site or setting aside for reuse.
Disconnecting , dismantling and taking down carefully single GI Strip of any size upto 32x6mm complete with saddles , GI tubing, insulators and segregation unsv or ser parts incl removing from site or setting aside for reuse.
Disconnecting , dismantling and taking down carefully single Aluminium Strip of any size upto 25x3.15mm complete with saddles , GI tubing, insulators and segregation unsv or ser parts incl removing from site or setting aside for reuse.
Supply and fixing single pointed air termination rod 12mm dia 300 mm long incl insulators , nuts bolts for fixing air termination with pipe all as specified at site.
Supply and fixing single pointed air termination rod 12mm dia 300 mm long incl insulators , nuts bolts for fixing air termination with pipe all as specified at site.
Supply and fixing GI Strip 32x6mm buried in ground upto 50 cm depth or fixed to walls with saddles/ insulators etc for loop earthing incl welding/nuts bolts for joints all as required at site or directed by Engr in charge.Note earth work shall not be measured separately.
Supply and fixing Aluminium Strip 25 x3.15mm buried in ground upto 50 cm depth or fixed to walls with saddles/ insulators etc for loop earthing incl welding/nuts bolts for joints all as required at site or directed by Engr in charge. Note earth work shall not be measured separately.
Supply and fixing in repair GI Strip 32x6mm buried in ground upto 50 cm depth or fixed to walls with saddles/ insulators etc for loop earthing incl welding/nuts bolts for joints all as required at site or directed by Engr in charge.Note earth work shall not be measured separately.
Supply and fixing in repair Aluminium Strip 25 x3.15mm buried in ground upto 50 cm depth or fixed to walls with saddles/ insulators etc for loop earthing incl welding/nuts bolts for joints all as required at site or directed by Engr in charge. Note earth work shall not be measured separately.
Supply and fixing in replacement porcelain viterous white/brown/green spacers insulators of size 75mmx35mmx40mm height complete with one no galvanized iron stud bolts size 6mm dia x 40mm long incl nuts and washers and two nos galvanized iron fixing bolts of size 6mm dia and 50mm long incl washers and drilling holes for holding or fixing aluminium strip or Roof conductor as required all as specified and directed.
Supply and fixing in replacement test point terminal block made up of gun metal or phosphorous bronze of size 75mmx75mmx25mm drilled and screwed incl 3 Nos 8mm dia 25mm long hexagonal head screw incl provn of 30x25x8cm sheet metal box made up of CRCA sheet 3.15mm thick with front hinged door shutter and locking arrangement and duly painted with two coats of synthetic enamel paint over a coat of Red oxide primer complete all as specified and directed.
Dismantling and taking down unsv Earthing of any type and Material and labour Earthing complete with galvanised steel earth plate elcrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground) with top edge of plate not less than 1.5m belwo bnormal ground level connecting to the GI erthing strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron and GI Strip 32x6mm protected by provision of GI Light grade pipe of 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 40mm grade crushed stone aggregrate iwh 40mm thick cover of RCC (1:2:4) raniforced with PM (weight not less than 4Kg/sqmm) and frame of angle iron 25x25x6mm with lugs 02 nos and 6mm dia MS bars handle made to shape, GI Light ggrade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge for earth platem common salt and charcoal filling, test point made out of 75x50x6mm phodphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hand/ dense soil rning filling in andremoval of surplus soil to a distance not exceeding 50m all as per electrical plate no 3 of SSR 1991 Pt-I and connecting to earh test point incl testing on completion.
Supply and fixing in replacement GI pipe medium grade 40mm dia required for fixing ATR complete incl fixing clamps all as specified and directed
Taking down old/unsv flood lights from high mast light of any type and M&L for LED flood light of capacity 250 watt IP 66 Lumainire with aluminium die cast housing toughened glass and unique lens system for enhancement illumination complete with all accessories Make Wipro cat part No LF3 -342-060-57XX or equivalent in specification of Make phillips, Oshram,wipro, GE
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15685-2006 of 60mm thickness with grey cement and pigment M35 Grade including 25mm thick sand filling with watering & consolidating all as specified and directed.
Surface excavation n. exc 30cm deep and averaging 15cm any type of soil all as specified and directed.
M&L for Soling of bricks and light wearing surfaces with low grade aggregates of sand, moorum or red bajri, any thickness all as specified and directed.
M&L for broken stone boulder hardcore of gauge exc 63mm but n exc 100mm deposited, spread and levelled in layers n. exc 15cm thick watered and rolled/ rammed to true surface.
M&L for cement concrete in foundation, filling and mass concrete type D2 1:4:8 40mm graded (100mm) all as specified and directed.
M&L for cement concrete Type B2 1:2:4 40mm graded aggregate 50mm thick all as specified and directed.
VISHAL CONSTRUCTION
NISHANT SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .