Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC 07 KH NO 198 KUDI BHAGTASANI JODHPUR 342001 RAJ | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC LOWEST ACCEPTED | |
| 2 | L2₹13.4 L+₹68,490 (5.39%)Rejected-AOC | L2 | Rejected-AOC L2 REJECTED | |
| 3 | L3₹13.4 L+₹73,179 (5.76%)Rejected-AOC | L3 | Rejected-AOC L3 REJECTED | |
| 4 | L4₹14.5 L+₹1.8 L (13.8%)Rejected-AOC | L4 | Rejected-AOC L4 REJECTED | |
| 5 | L5₹14.5 L+₹1.8 L (14.3%)Rejected-AOC | L5 | Rejected-AOC L5 REJECTED |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
29 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
SPL REP OF OP SHELTERS - 9020/05-06/216, 9015/05-06/158, 9015/05-06/213 NEAR COMD OFFRS MESS UNDER GE(S) AT JAIPUR MIL STN
2024_MES_657416_1
CWE/JPR(S)/82373/E8
Open Tender
Civil Works
Item Rate
180 days
JAIPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE(S) JAIPUR
₹29,000
Yes
31 Aug 2024
3 Jun 2024
1 Jul 2024
3 Jun 2024
29 Jun 2024
17 Jun 2024
3 Jun 2024 - 16 Jun 2024
Amount
Taking down cement plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish outside MoD land complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for two coat of cement base paint including preparation of newly plaster surface complete all as specified and directed.
M&L for one coat of cement base paint including preparation of old painted surface complete all as specified and directed.
M & L for two coat of oil bond distemper including complete removal of existing treatment surface complete all as specified and directed.
Dismantling of cement concrete tiles,glazed tiles, terrazo tiles,kota stones in floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish outside MoD land complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 15mm thick (1:6) cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Dismantling wall & ceiling board (fibre, pulp, insulation etc) or insulation boards/slab/ blankets any thickness including cover fillets complete all as specified and directed.
Supply & fixing 6 mm dia galvanized steel wire hangers (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified .
Providing and fixing 6mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as per manufacturers instructions and all as directed by Engr in charge
Supply & fixing anodized aluminium snap grid framework for false ceiling, size of snap grid frame work 605 mm x 605 mm complete all as specified and as directed.
Dismantling plain or corrugated steel / FRP sheeting any gauge, thickness including nainital or similar pattern roof /wall covering complete all as specified and directed.
S & F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S &F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; framed works in sheds, ladders; framed balusters; walk ways; railings;sheds, door frame ,framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed
M&L preparation old untreated steel surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint over complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S & F Sheet glass ordinary quality and glazingwith oil puttyin square n.exc 0.50 sqm in each pane in 4 mm thickness complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down shutter of any description exc. 1 sqm but n.exc 2 sqm each and removing from site complete all as specified and directed. .
S & F 35mm thick flush shutters solid core construction with block board and plywood face panels, fixed with approved adhessive incl lipping all round the edges of door as per manufacturers instructions
M&L for decorative laminate type 1, 0.9 mm thick colour and pattern as approved fixed as in door shutters with adhesive all as specified and directed
S & F 35mm thick second class hardwood factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc divided into square , with plain, chamfered or rounded, mitred and rebated sash bars any numbers , fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. Note :- S & F Glass/gauge shall be measured and paid for separately
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed to wodden door shutters complete all as specified and directed.
S&F aluminium mesh of weight exc.0.55 Kg/Sqm as support to SS wire cloth complete all as specified and directed.
M&L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed
M&L for preparation of old painted wooden or wood based surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint over complete all as specified and directed.
S&F aluminium anodized barrel tower bolts 200mm long of extruded section complete all as specified and directed.
S&F aluminium anodized handle 150mm long, cast type complete all as specified and directed.
S&F aluminium anodised sliding door bolt 250mm long with hasp and staple (bolt type an fixing clips of sheet or extruded section an fixing bolts and sliing bolt of extruded section complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD Land complete all as specified and directed.
M & L brick work using Subclass B bricks in exc. 6 m mean radius on plan built in cement mortar 1:6 complete all as specified and directed.
Demolition of cement concrete (un-reinforced) at any floor and pavings not exceeding 15 cm thickness below or above ground level complete all as specified and directed incl removing the rubbish outside MoD land complete all as specified and directed.
Demolition of reinforced cement concrete any description as in roofs, floors (Other than ground floors), beams, staircases, landing, chajjas, slab, RCC water storage tanks & similar suspended work complete all as specified and directed incl removal all rubbish material where directed.
M & L for grinding and polishing of existing kota stone flooring and skirting all as specified
S & F SS butt hinges 100mm size medium weight and fixed as directed and specified.
M & L for anti termite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in kerb stone/coping complete all as specified and directed.
Taking down carefully surface aluminium or copper point wiring with PVC casing or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good disturbed surfaces of walls, floors, etc all as directed.
Taking down celing fan of any size, sealing cable end , dismantling blade and removing fan regulator any type & size and keepinig in safe custudy for reuse/deposite to MES store all as specified and directed by Engr-in-Charge .
Refixing of ceiling fans after required minor repairs such as replacement of capacitor,connector block, split pin nuts bolts etc and connecting up including provisioning of cable from ceiling rose or connector to fan and painting of ceiling fan complete in situ with synthetic enamel paint by spraying including filling cavity with filler , one coat after cleaning or dust etc complete.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and suitable size PVC gang boxes of thickness not less than 1.0 mm one light point controlled by one switch. Note:- Rate of gang box is included in quoted rate for the fitment of switch and socket.
All as per item No. 45 above but one light point controlled by two, two way switch.
All as per item No. 45 above but one fan Exhaust fan point controlled by one switch.
All as per item No. 45 above but one socket outlet 6 Amps controled by one switch on the same board with other switches.
All as per item No. 45 above but one socket outlet 6 Amps controlled by one switch on independent board.
All as per item No. 45 above but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 4.0 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 4.0 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16mm ISI marked ivory colour with all fittings/fixing accessories and suitable size gangboxes of thickness not less than 1.0mm for mounting switches, sockets for one 16 Amps socket outlet point controlled by one switch on independent board.Note:- Rate of gang box is included in quoted rate for the fitment of switch and socket.Note:- Rate of gang box is included in quoted rate for the fitment of switch and socket. Note for Item No 4 to 10 :- (a) The cost of Modular gang box & modular cover plate colour and size as required at site to be included in quoted rate. (b) Modular switch/socket accessories shall be measured & paid separately in respective item
S&F switch modular 1 way 6/10 Amps, 230 volts, 1 module. Make : Anchor (Roma), Legrand CRABTREE)
S&F modular socket 6/10 Amps, 2/3pin combined 2 module AC 230 volts. Make : Anchor (Roma), Legrand CRABTREE)
S&F modular switch 1 way 16/20 Amps, 230 volts, 1 module. Make :Anchor (Roma),Legrand CRABTREE)
S&F modular socket 16/20 Amps, 2/3pin combined 2 module AC 230 volts. Make : Anchor (Roma),Legrand CRABTREE)
S&F modular fan regulator 120 watts, 2-module AC 230 Volts. Make : Anchor (Roma), Legrand CRABTREE)
S&F switch modular 2 way 6/10 Amps, 230 volts, 1 module. Make : Anchor (Roma), Legrand CRABTREE)
S&F Modular bell push 6A 1 module Make: Anchor (Roma), Legrand CRABTREE)
S&F musical bell, AC, 230 volts, single pole. Make : Anchor , Legrand, Honeywell Elect.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper cable of size 2 x 6 sqmm drawing into and including PVC casing-capping fixed on surface of wall not less than 32x16mm ISI marked ivory colour with all fittings/fixing accessories and 6 sqmm FRLS multistranded copper conductor cable as continuous earth wire complete all as specified and directed Note :- 2 runs of 6 sqmm copper wire and 1 run of 6 sqmm copper earth wire alongwith PVC casing capping shall be measured as 1 unit.
S&F 20 amp, single pole and neutral socket outlet with 2 pole and earthy, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for socket outlet with and including one number single pole 'C' series MCB 20 amp as required. Make- Legrand/Hager/ABB as approved.
S&F MCB distribution board TPN, 415 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS:8623, degree of protection IP 43-IK09 with metal door, recess mounted , having insulated 100 amp tinned copper bus bar, earth bar, din bar, detachable gland plate, interconnection , earthing connection, blanking plates in unused spaces as required.
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCBs of Single pole 6 to 32 amp. Make - Legrand cat ref no 408587 to 408595 or eqvt in HAGER and ABB
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Double pole 10 to 32 amp. Make - Legrand cat ref no 4086 14 to 4086 17 ,ABB,HAGER
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 40 to 63 amp. Make - Legrand cat ref no 4086 59 to 4086 61
Excavation in trenches n.exc 1.5metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil
M & L Sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in depth.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50 metre above the starting point
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade of following sizes: a) 25 Sqmm 4 Core
M&L for boring of existing road/path upto 100 mm bore for laying of GI pipe protection for UG cable including making good distrurbed area/surface all as specified and directed.
Galvanised steel tubing light grade size upto 80 mm bore for protection of under ground cable on poles / walls under road crossing etc conforming to IS-1239 including taking out/down of existing GI pipe.
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete as directed by Engr-in Charge.
S&F in repairs Bulk Head light environfriendly ultra modern energy saving surface mounted decorativeoval bulk head edge lit LED luminaire comprising of High brightness LED Lamp. Make:- Havells Cat Part No. RUGBYGENXFTS10WLED865SSYMBOPC or equivalent cat part in Bajaj, POLYCAB, Philips etc.
S&F ceiling fan type 1200 mm sweep 50 Hz AC 230 volts, BEE 5 star rated in white colour with fan motor, blade set , 0.45 mtr down rod, canopy. Make:- cat part Havells ES-50, CG, Orient
Less Schedule of Credit
MSR INFRATECH
S.R.Enterprises
UNIVERSAL INFRAPROJECT PVT LTD
M/S ROHIT CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .