Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20 LAccepted-AOC | ₹20 L | L1 | Accepted-AOC L1 |
| 2 | L2₹21.2 L+₹1.2 L (6.00%)Rejected-Finance | ₹21.2 L+₹1.2 L (6.00%) | L2 | Rejected-Finance L2 |
| 3 | L3₹21.4 L+₹1.4 L (7.00%)Rejected-Finance | ₹21.4 L+₹1.4 L (7.00%) | L3 | Rejected-Finance L3 |
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
2 Jun 2026, 5:00 pmClosed
Sarpanch
AT-UJLAIWADI TAL-KARVEER DIST-KOLHAPUR
EXTENSION AND CONSTRUCTION OF GRAM PANCHYAT BUILDING AND PROVIDING FURNITURE WORK AT-UJLAIWADI TAL-KARVEER DIST-KOLHAPUR (15 TH F.C. YEAR 2025-26)
2026_KOLHA_1304232_1
01/2026-27
Open Tender
Civil Works - Buildings
Percentage
270 days
AT-UJLAIWADI TAL-KARVEER DIST-KOLHAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹20,000
18 Jun 2026
19 May 2026
3 Jun 2026
19 May 2026
2 Jun 2026
19 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)
Item / Page No : 33 / 134
Specification No : Bd.F.5, B-7
Spec. Page No : 300, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | 1 | ₹1 |
| 2 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete.
Item / Page No : 5 / 144
Specification No : Bd.G.5
Spec. Page No : 315
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | 1 | ₹1 |
| 3 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete.
Item / Page No : 12 / 130
Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge. | - | Metric Ton | 0.29 | - |
| 4 | Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre).
Item / Page No : 34 / 173
Additional Specifications : The work shall be done as per instructions of Engineer in charge. | - | Square Metre | - | - |
| 5 | Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates, excetra as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete.
Item / Page No : 11 / 130
Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge. | 1 | Metric Ton | 1 | ₹1 |
| 6 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete.
Item / Page No : 1 / 192
Specification No : Bd.U.1
Spec. Page No : 537 | - | Square Metre | 1 | - |
| 7 | Providing and laying cast in situ / Ready Mix Cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)
Item / Page No : 19 / 137
Specification No : Bd.F.11, B-7
Spec. Page No : 304, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | 1 | ₹1 |
| 8 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete.
Item / Page No : 33 / 139
Specification No : Bd.F.17
Spec. Page No : 306 | 1 | Metric Ton | 1 | ₹1 |
| 9 | Providing and laying damp proof course 50 milimetre thick in M-20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork, excetra complete.
Item / Page No : 1 / 150
Specification No : Bd.J.2
Spec. Page No : 355
Additional Specifications : 1. With addtional specifiactions for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Square Metre | - | - |
| 10 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete.
Item / Page No : 5 / 144
Specification No : Bd.G.5
Spec. Page No : 315
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | 1 | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_2239052.xls
BOQ • 0.30 MB
SBD2026.pdf
Tender Documents • 1.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .